首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, a combined methodology using off-line solid-phase extraction (SPE), on-line field-enhanced sample injection (FESI) and coelectroosmotic capillary electrophoresis with UV detection (CE-UV) is developed for the trace analysis of five triazolopyrimidine sulfonanilide pesticides (i.e., flumetsulam, florasulam, cloransulam-methyl, diclosulam and metosulam). An adequate background electrolyte (BGE) was obtained for the separation of these pesticides using hexadimethrine bromide (HDB) as electroosmotic flow (EOF) modifier. This BGE consisted of 0.00042% HDB, 11 mM formic acid, 16 mM ammonium carbonate and 2.5 mM alpha-CD solution at pH 7.6. The use of this running buffer together with the FESI preconcentration method provided limits of detection (LODs) in the low microg/L range (i.e., between 13.0 and 31.5 microg/L). The optimized FESI-CE-UV method was combined with off-line SPE using C(18) cartridges and applied to the determination of the selected group of pesticides in soil samples. Recovery percentages ranged between 50 and 84% in these samples with LODs between 18 and 34 microg/kg. This work shows the great possibilities of the combined use of SPE-FESI-CE-UV to improve CE sensitivity allowing the achievement of LODs similar to other analytical techniques as GC or HPLC.  相似文献   

2.
In this work, the determination of a group of triazolopyrimidine sulfoanilide herbicides (cloransulam-methyl, metosulam, flumetsulam, florasulam, and diclosulam) in soy milk by capillary electrophoresis-mass spectrometry (CE-MS) is presented. The main electrospray interface (ESI) parameters (nebulizer pressure, dry gas flow rate, dry gas temperature, and composition of the sheath liquid) are optimized using a central composite design. To increase the sensitivity of the CE-MS method, an off-line sample preconcentration procedure based on solid-phase extraction (SPE) is combined with an on-line stacking procedure (i.e. normal stacking mode, NSM). Samples could be injected for up to 100 s, providing limits of detection (LODs) down to 74 microg/L, i.e., at the low ppb level, with relative standard deviation values (RSD,%) between 3.8% and 6.4% for peak areas on the same day, and between 6.5% and 8.1% on three different days. The usefulness of the optimized SPE-NSM-CE-MS procedure is demonstrated through the sensitive quantification of the selected pesticides in soy milk samples.  相似文献   

3.
谷从影  蔺丽  方能虎  贾金平 《色谱》2007,25(2):174-178
以甲基丙烯酸丁酯为单体,乙二醇二甲基丙烯酸酯为交联剂,在致孔剂存在的条件下原位聚合制备了甲基丙烯酸丁酯毛细管整体柱(150 μm i.d.)。实验中优化了用此整体柱分离3种微囊藻毒素(MC-LR,-YR和-RR)的色谱条件(流动相种类、缓冲溶液浓度、pH、流动相流速),建立了微囊藻毒素的整体柱毛细管液相色谱分离方法,该法可以在9 min之内实现3种微囊藻毒素的基线分离。将该方法应用于实际水样中微囊藻毒素的分析,成功实现了培养水样和巢湖水样中微囊藻毒素的快速分离,两种样品中均检测到MC-LR。结果表明,所制备的甲基丙烯酸酯毛细管整体柱具有良好的重现性、渗透性,在微囊藻毒素的常规检测中具有很好的应用前景。  相似文献   

4.
Gu C  Lin L  Chen X  Jia J  Wu D  Fang N 《Journal of separation science》2007,30(17):2866-2873
A polymethacrylate-based monolithic column was prepared and its application to the separation of three kinds of similar microcystins (MCs) in capillary high performance liquid chromatography (capillary-HPLC) with ultraviolet detection was studied. The monolithic matrix contains both hydrophobic and cation-exchange interaction sites. Factors influencing the separation performance have been investigated. A baseline separation could be achieved by means of Tris(hydroxymethyl)aminomethane buffer of mildly alkaline pH and acetonitrile as the mobile phases in less than 5 min. The calibration curves were linear with a correlation coefficient r>0.9990 over a range of 0.25-18.00 mg/L. This method was successfully applied to the separation of microcystins from other compounds in spiked uncontaminated lake water after performing solid-phase extraction. The whole procedure provided low LODs, e. g. the LODs for MC-LR, MC-YR, and MC-RR were found to be 0.49, 0.67, 0.30 microg/L, respectively. The LODs, precision, efficiency, and the results obtained for the real samples demonstrate the potential of polymethacrylate-based monolithic columns as fast separation tools for routine use in the monitoring of microcystins in real water samples.  相似文献   

5.
In this work, four ionic liquids differing in the length of the alkyl chain on the imidazolium cation and one ionic liquid containing tetraethylammonium, all with the same counterion, (i.e. 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIm-BF(4)), 1-butyl-3-methylimidazolium tetrafluoroborate (BMIm-BF(4)), 1-hexyl-3-methylimidazolium tetrafluoroborate (HMIm-BF(4)), 1-methyl-3-octylimidazolium tetrafluoroborate (MOIm-BF(4)), and tetraethylammonium tetrafluroborate (Et(4)N-BF(4))) were tested as mobile phase additives for HPLC separation of a group of seven basic fluoroquinolone (FQ) antibiotics for human and veterinary use (i.e. fleroxacin, ciprofloxacin, lomefloxacin, danofloxacin, enrofloxacin, sarafloxacin, and difloxacin) using a conventional reversed-phase Nova-Pak C(18) column. Fluorescence detection was used. Among the ionic liquids selected, use of BMIm-BF(4) enabled effective separation of these compounds with relatively low analysis time (14 min). The best separation was achieved by isocratic elution at 1 mL min(-1) with 5 mmol L(-1) BMIm-BF(4) and 10 mmol L(-1) ammonium acetate at pH 3.0 with 13% (v/v) acetonitrile. Limits of detection (LODs) for fluorescence detection were in the range 0.5-11 microg L(-1). The method was tested by analyzing several water samples after the optimization of a suitable solid-phase extraction (SPE) procedure using Oasis HLB cartridges. Mean recovery values were above 84% for all analytes with LODs in the range 1-29 ng L(-1).  相似文献   

6.
In this work, the combined use of solid-phase extraction (SPE) and on-line preconcentration strategies as normal stacking mode (NSM) and stacking with matrix removal (SWMR) for the ultrasensitive and simultaneous capillary electrophoresis-ultraviolet analysis (CE-UV) of five triazolopyrimidine sulfonanilide pesticides (i.e., diclosulam, cloransulam-methyl, flumetsulam, metosulam and florasulam) in different types of water is investigated. An adequate separation electrolyte for the separation and stacking of these pesticides was obtained, considering also its compatibility with MS detection, which consisted of 24 mM formic acid and 16 mM ammonium carbonate at pH 6.4. It was observed that the use of this running buffer together with the SWMR preconcentration method provided the best results in terms of sensitivity (between 6.54 and 11.9 microg/L) and peak efficiency (up to 550000 theoretical plates per meter, NTP/m). When this on-line preconcentration procedure was combined with an off-line sample preconcentration step as SPE using C18 cartridges, the selected herbicides could be detected in the ng/L range. The optimized SPE-SWMR-CE-UV method was applied to the determination of the selected group of pesticides in spiked and non-spiked mineral and stagnant waters. Recoveries ranged between 55 and 110% and limits of detection between 131 and 342 ng/L. This work shows the great possibilities of the combined use of SPE-SWMR-CE-UV to overcome the sensitivity problems usually linked to CE analysis.  相似文献   

7.
建立了基于聚合物整体柱的固相萃取-高效液相色谱测定尿液中4种羟基多环芳烃(OH-PAHs)的分析方法。在注射器管中合成聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)整体柱(poly (BMA-co-EDMA)),并将其用于尿液中4种羟基多环芳烃的前处理,同时考察了上样浓度、淋洗液、洗脱液和洗脱体积对萃取效率的影响。结合高效液相色谱-荧光分析,4种羟基多环芳烃在各自的范围内线性关系良好(r≥0.9991);方法的检出限和定量限分别为0.06~0.09 ng/mL和0.20~0.30 ng/mL;日内(n=5)和日间(n=3)精密度分别为1.4%~5.3%和2.6%~7.3%。对焦炉工人尿液样品进行加标(3 ng/mL)回收试验,回收率为78.2%~117.0%。该固相萃取柱能够有效萃取和净化尿液中4种羟基多环芳烃,并且可以重复使用。该法简单、准确,可应用于尿液中羟基多环芳烃的分析。  相似文献   

8.
Gu C  Lin L  Li B  Chen X  Ren J  Jia J  Wu D  Fang N 《Electrophoresis》2008,29(18):3887-3895
As a new wave of technology, polymethacrylate-based monolithic column was prepared and its application in the separation of three kinds of microcystins (MCs) in pressurized capillary electrochromatography with ultraviolet detection was studied. The key factors affecting the separation performance, such as monolithic column, pressure of the pump, component and concentration of mobile phase and the voltage, were investigated and optimized in detail. A baseline separation could be achieved in less than 6 min using a 5 mM borate buffer with a pH of 9.6 and 10% acetonitrile as the mobile phases in isocratic elution, under a voltage of +13 kV and a supplementary pressure of 7.5 MPa. The calibration curves were linear with correlation coefficient r>0.998 over a range of 0.10-25.00 mg/L. The LODs for the three MCs were in the range of 0.03-0.09 mg/L. This method was successfully applied to separate MCs from other compounds in spiked tap water after solid-phase extraction. The lower LODs for MC-LR, MC-YR and MC-RR were obtained to be 0.10, 0.13, 0.16 microg/L, respectively. These results make it clear that this proposed system is accurate and robust enough to be used as a fast separation tool for routine monitoring of MCs in real water samples.  相似文献   

9.
The current study was undertaken to validate the performance for the determination of both TBA and beta-trenbolone (beta-TB) residues in porcine muscle at concentrations required to monitor compliance with the maximum residue limit (MRL). The method involves a one phase liquid-liquid extraction, cleanup with low-temperature fat precipitation, separation of the respective compounds by HPLC on a Capcell pak C(18) column, use of a methanol-water isocratic system as an eluent, and measurement by UV absorbance detection at 340 nm. Both compounds were confirmed using LC-MS/MS with electrospray interface (ESI) and a triple quadrupole (QqQ) analyzer. The method was found to be precise and accurate, with a linearity range of 1-10 microg/kg (r(2) >0.973). The intra- and interday precision showed good reproducibility with RSDs < or =13.25%. The LODs were 0.12 and 0.22 microg/kg, and the LOQs were 0.37 and 0.66 microg/kg, for TBA and beta-TB, respectively. The applicability of the method was demonstrated by analyzing real samples collected from major cities in the Republic of Korea. No residues of the selected compounds were detected in any of the samples. The advantages of our method are that it is: selective, sensitive, requires a short time for analysis (13 min), and performs simple sample extraction and clean-up procedure with low-temperature fat precipitation as compared to the previously published methods.  相似文献   

10.
A fully automated method for determining nine Environmental Protection Agency N-nitrosamines in several types of environmental waters at ng/L levels is presented. The method is based on a headspace solid-phase microextraction followed by GC-MS-MS using chemical ionization. Three different fibers (carboxen/PDMS, divinylbenzene/carboxen/PDMS, and PEG) were tested. Solid-phase microextraction conditions were best when a divinylbenzene/carboxen/PDMS fiber was exposed for 60?min in the headspace of 10?mL water samples at pH 7 containing 360?g/L of NaCl, at 45°C. All compounds were analyzed by GC-MS-MS within 18?min. The method was validated using effluent from an urban wastewater treatment plant and the LODs ranged from 1 to 5?ng/L. The method was then applied to determine the N-nitrosamines in samples of different complexities, such as tap water and several influent and effluent wastewater samples from urban and industrial wastewater treatment plants and a potable water treatment plant. Although the analysis of influent industrial wastewater revealed high concentrations of some compounds (N-nitrosomorpholine and N-nitrosodimethylamine at μg/L levels), in industrial effluents and other samples, the concentrations were substantially lower (ng/L levels). The new method is suitable for the simple and reliable determination of N-nitrosamines in highly complex water samples in a completely automated procedure.  相似文献   

11.
A fully automated system for on-line solid phase extraction (SPE) followed by high-performance liquid chromatography (HPLC) with tandem detection with a photodiode array detector and a fluorescence detector (after postcolumn derivatization) was developed for analysis of many chemical classes of pesticides and their major conversion products in aquatic systems. An automated on-line-SPE system (Prospekt) operated with reversed-phase cartridges (PRP-1) extracts analytes from 100 mL acidified (pH = 3) filtered water sample. On-line HPLC analysis is performed with a 15 cm C18 analytical column eluted with a mobile phase of phosphate (pH = 3)-acetonitrile in 25 min linear gradient mode. Solutes are detected by tandem diode array/derivatization/fluorescence detection. The system is controlled and monitored by a single computer operated with Millenium software. Recoveries of most analytes in samples fortified at 1 microgram/L are > 90%, with relative standard deviation values of < 5%. For a few very polar analytes, mostly N-methylcarbamoyloximes (i.e., aldicarb sulfone, methomyl, and oxamyl), recoveries are < 20%. However, for these compounds, as well as for the rest of the N-methylcarbamates except for aldicarb sulfoxide and butoxycarboxim, the limits of detection (LODs) are 0.005-0.05 microgram/L. LODs for aldicarb sulfoxide and butoxycarboxim are 0.2 and 0.1 microgram, respectively. LODs for the rest of the analytes except 4-nitrophenol, bentazone, captan, decamethrin, and MCPA are 0.05-0.1 microgram/L. LODs for the latter compounds are 0.2-1.0 microgram/L. The system can be operated unattended.  相似文献   

12.
This paper compares the advantages and disadvantages of two different configurations for the extraction of triazines from water samples: (1) on-fibre solid-phase microextraction (SPME) coupled to conventional liquid chromatography (LC); and (2) in-tube SPME coupled to capillary LC. In-tube SPME has been effected either with a packed column or with an open capillary column. A critical evaluation of the main parameters affecting the performance of each method has been carried out in order to select the most suitable approach according to the requirements of the analysis. In the on-fibre SPME configuration the fibre coating was polydimethylsiloxane (PDMS)-divinylbenzene (DVB). The limits of detection (LODs) obtained with this approach under the optimized extraction and desorption conditions were between 25 and 125 microg/L. The in-tube SPME approach with a C18 packed column (35 mm x 0.5 mm I.D., 5 microm particle size) connected to a switching micro-valve provided the best sensitivity; under such configuration the LODs were between 0.025 and 0.5 microg/L. The in-tube SPME approach with an open capillary column coated with PDMS (30 cm x 0.25 mm I.D., 0.25 microm of thickness coating) connected to the injection valve provided LODs between 0.1 and 0.5 microg/L. In all configurations UV detection at 230 nm was used. Atrazine, simazine, propazine, ametryn, prometryn and terbutryn were selected as model compounds.  相似文献   

13.
A novel LC-fluorescence detection method based on the use of a monolithic column for the determination of norfloxacin, ciprofloxacin, and enrofloxacin antibiotic residues in environmental waters was developed. Fluoroquinolones (FQs) were isocratically eluted using a mobile phase consisting of 0.025 M phosphoric acid solution at pH 3.0 with tetrabutylammonium and methanol (960:40, v/v) through a Chromolith Performance RP-18e column (100x4.6 mm) at a flow rate of 2.5 mL/min and detected at excitation and emission wavelengths of 278 and 450 nm, respectively. After acidification and addition of EDTA, water samples were extracted using an Oasis HLB cartridge. Linearity was evaluated in the range of 0.05 to 1 microg/mL and correlation coefficients of 0.9945 for norfloxacin, 0.9974 for ciprofloxacin, and 0.9982 for enrofloxacin were found. The limit of quantification was 25 ng/L for the three FQs. The recovery of FQs spiked into river water samples at 25, 50, and 100 ng/L fortification levels ranged from 76.5 to 91.0% for norfloxacin, 78.5 to 97.2% for ciprofloxacin, and 79.4 to 93.6% for enrofloxacin. This method was successfully applied to the analysis of water samples from the Mondego River, and ciprofloxacin and enrofloxacin residues were detected in eight water samples.  相似文献   

14.
In this work, a new multiresidue analytical method based on MEKC with UV detection combined with SPE as off-line preconcentration strategy, and reversed-electrode polarity stacking mode (REPSM) as on-line stacking procedure, has been developed for the monitoring of 12 pesticides (carbendazim, pirimicarb, metalaxyl, pyrimethanil, procymidone, nuarimol, azoxystrobin, tebufenozide, fenarimol, benalaxyl, penconazole, and tetradifon) that are currently being used in the Canary Islands (Spain). The optimized MEKC buffer, consisting of 100 mM sodium tetraborate and 30 mM SDS at pH 8.5 with 6% v/v 1-propanol, provided baseline resolution of the 12 pesticides in less than 20 min. The developed method was applied to the analysis of mineral, stagnant, and tap water samples. The proposed SPE-REPSM-MEKC-UV method showed high extraction efficiencies with detection limits (LODs) at the low ng/L level providing LOD values down to 64 ng/L for these real samples.  相似文献   

15.
In-tube solid-phase microextraction (SPME) based on a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was investigated for the extraction of amphetamine, methamphetamine and their methylenedioxy derivatives. The monolithic capillary column showed high extraction efficiency towards target analytes, which could be attributed to its larger loading amount of extraction phase than conventional open-tubular extraction capillaries and the convective mass transfer procedure provided by its monolithic structure. The extraction mechanism was studied, and the results indicated that the extraction process of the target analytes was involved with hydrophobic interaction and ion-exchange interaction. The polymer monolith in-tube SPME-HPLC system with UV detection was successfully applied to the determination of amphetamine, methamphetamine and their methylenedioxy derivatives in urine samples, yielding the detection limits of 1.4 - 4.0 ng/mL. Excellent method reproducibility (RSD < 2.9%) was found over a linear range of 0.05-5 microg/mL, and the time for the whole analysis was only approximately 25 min. The monolithic capillary column was reusable in coping with the complicated urine samples.  相似文献   

16.
Fan Y  Feng YQ  Da SL  Gao XP 《The Analyst》2004,129(11):1065-1069
Ketamine was used for anaesthesia originally but has emerged as an abused drug in recent years. The prevalence of ketamine abuse demands a direct and rapid determination method. It is known that in-tube solid phase microextraction (in-tube SPME) can perform extraction with a capillary linked directly to a HPLC system, providing an automated and accurate extraction procedure. In this paper, an in-tube SPME coupled to HPLC method was developed for the determination of ketamine in urine samples with a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column as the extraction phase, which is expected to provide higher extraction efficiency than open tubular capillaries. After optimizing the extraction conditions, ketamine was extracted directly from urine samples in a wide dynamic linear range of 50-10,000 ng mL(-1), with the detection limit obtained as 6.4 ng mL(-1). The intra-day and inter-day precision for the method was 1.6% and 1.7%, respectively. The urine samples from suspect addicts have been successfully analyzed within 20 min. The re-usability of the monolithic column was also confirmed as no decrease of the extraction efficiency was shown after urine extraction.  相似文献   

17.
杨欣茹  杨更亮  朱涛  封晓娟  杨冠群 《色谱》2009,27(2):197-200
以甲基丙烯酸(MAA)为功能单体,乙二醇二甲基丙烯酸酯(EDMA)为交联剂,以色谱柱管为模具,通过原位聚合法制备了弱阳离子交换整体柱。该柱能去除血浆中的内源性物质,对生物样品中的药物有富集作用。将其作为固相萃取柱与C18色谱柱联用,在线分析了人血浆中的硝苯地平。流动相为甲醇-水(体积比为70∶30),流速1.0 mL/min,检测波长235 nm。结果表明,硝苯地平在5.0~75.0 μg/L范围内线性关系良好(r=0.9993),方法的回收率为90.0%~99.0%,日内、日间相对标准偏差均小于5.0%。该方法精密度高,重现性良好,避免了繁琐的样品预处理过程,且弱离子整体柱可多次重复使用,为检测血浆中的痕量药物提供了一种快速、经济、有效的新方法。  相似文献   

18.
In the present work we report a novel procedure for in‐capillary microextraction using a monolithic polymeric sorbent. In the proposed methodology, sample treatment takes place in the CE instrument but in a different capillary from that used for the electrophoretic separation. Polymers based on butyl methacrylate and divinylbenzene formed in situ inside a capillary column were assayed. The best results were found with the divinylbenzene‐based polymers. The usefulness of the proposed procedure was checked for the determination of carbamate pesticides (Methomyl, Asulam, Carbendazim, Aldicarb, Carbetamide, Propoxur, Pirimicarb, Carbaryl, Carbofuran and Methiocarb) and three of their degradation compounds (Aldicarb sulphoxide, 2‐isopropoxyphenol and α‐naphthol) using MEKC. The optimization of the MEKC is reported, a good separation of the 13 analytes being obtained in less than 6 min. The analytical method using in‐capillary microextraction was validated in terms of linearity, repeatability, precision (RSD≤18% for 50 μg/L), and LODs (1–16 μg/L), and it revealed the usefulness of this in‐capillary preconcentration procedure for the determination of analytes of intermediate polarity.  相似文献   

19.
A new multiresidue method has been developed and validated for the simultaneous analysis of 57 compounds, including organochlorine and organophosphorus pesticide residues (OCPs and OPPs) and polychlorinated biphenyls (PCBs), in eggs at trace levels by gas chromatography coupled to triple quadrupole mass spectrometry (GC-QqQ-MS/MS). Egg samples were extracted by a simple and fast matrix solid phase dispersion (MSPD) procedure using C18 as sorbent, and ethyl acetate and acetonitrile saturated in n-hexane (85:15, v/v) as elution solvent with a simultaneous clean up with Florisil in-line. The QqQ analyzer acquired data in selected reaction monitoring (SRM) mode, permitting both quantification and confirmation in a single injection with a running time reduced up to 17.70 min. Recovery was in the range of 70-110% and 70-106% at 15 and 50 microg/kg, respectively. Precision values expressed as relative standard deviation (RSD) were lower than 20%. Linearity in the range of 10-150 microg/kg provided determination coefficients (R(2)) higher than 0.98 for all compounds. Limits of detection (LODs) for pesticides were < or =2.25 microg/kg and limits of quantification (LOQs) ranged from 0.02 to 7.78 microg/kg. LODs for PCBs were < or =0.41 microg/kg and LOQ were < or =0.71 microg/kg. The method was applied to real samples. Endosulfan sulphate and p,p'-DDE were found in two samples at concentrations below the first calibration level.  相似文献   

20.
The performance of a monolithic C(18) column (150 mm×0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C(18) column (150 mm×0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorpyrifos (organophosphorous), diuron and isoproturon (phenylureas), trifluralin (dinitroaniline) and di(2-ethylhexyl)phthalate. The results obtained revealed that the monolithic column was clearly advantageous in the context of multiresidue organic pollutants analysis for a number of reasons: (i) the selectivity was considerably improved, which is of particular interest for the most polar compounds triazines and phenyl ureas that could not be resolved in the particulate column, (ii) the sensitivity was enhanced, and (iii) the time required for the chromatographic separation was substantially shortened. In this study it is also proved that the mobile-phase flow rates used for separation in the capillary monolithic column are compatible with the in-valve IT-SPME methodology using extractive capillaries of dimensions similar to those used in conventional scale liquid chromatography (LC). On the basis of these results a new method is presented for the assessment of pollutants in waters, which permits the characterization of whole samples (4 mL) in less than 30 min, with limits of detection in the range of 5-50 ng/L.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号