首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

2.
Sucrose esters (SEs) were successfully extracted from Oriental tobacco leaves using a new methodology based on accelerated solvent extraction followed by hydrophilic–lipophilic balanced cartridge cleanup step. The SEs were detected by HPLC with ion‐trap MS detection using an electrospray interface operated in the positive ion mode. This methodology combines the high efficiency of extraction provided by a pressurized fluid and the highly sensitive characterization offered by ion‐trap MS. Under the optimized conditions, 14 SEs were first identified among a total of 23 SEs found in Oriental tobacco leaves. Under the same conditions, only four new SEs were extracted by using traditional ultrasound‐assisted extraction and liquid–solid extraction methods. The present method might be potentially useful in high‐efficiency extraction and sensitive characterization of SEs from complex matrices such as tobacco leaves.  相似文献   

3.
Two simple and rapid LC/MS methods with direct injection analysis were developed and validated for the quantification and identification of hydrocortisone in equine urine using the same sample preparation but different mass spectrometric systems: ion trap mass spectrometry (IT-MS) and time-of-flight mass spectrometry (TOF-MS). The main advantage of the proposed methodology is the minimal sample preparation procedure, as particle-free diluted urine samples were directly injected into both LC/MS systems. Desonide was used as internal standard (IS). The linear range was 0.25-2.5 microg ml(-1) for both methods. Matrix effects were evaluated by preparing and analyzing calibration curves in water solutions and different horse urine samples. A great variation of the signal both for hydrocortisone and the internal standard was observed in different matrices. To overcome matrix effects, the unavailability of blank matrix and the excessive cost of the isotopically labeled internal standard, standard additions calibration method was applied. This work is an exploration of the performance of the standard additions approach in a method where neither nonisotopic internal standards nor extensive sample preparation is utilized and no blank matrix is available. The relative standard deviations of intra and interday analysis of hydrocortisone in horse urine were lower than 10.2 and 5.4%, respectively, for the LC/IT-MS method and lower than 8.4 and 4.4%, respectively, for the LC/TOF-MS method. Accuracy (bias percentage) was less than 9.7% for both methods. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

4.
A rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of fexofenadine in human plasma using mosapride as internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 502/466 for fexofenadine and m/z 422/198 for the IS. The method exhibited a linear dynamic range of 1-500 ng/mL for fexofenadine in human plasma. The lower limit of quantification was 1 ng/mL with a relative standard deviation of less than 5% for fexofenadine. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time of 2 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

5.
A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of pseudoephedrine in human plasma using mosapride as internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple-reaction monitoring mode using the respective [M + H](+) ions, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited a linear dynamic range of 2-1000 ng/mL pseudoephedrine in human plasma. The lower limit of quantification was 2 ng/mL with a relative standard deviation of less than 9% for pseudoephedrine. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time of 2 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

6.
A rapid and sensitive LC‐MS/MS method for the quantification of fenofibric acid in rat plasma was developed and validated. Plasma samples were prepared by liquid–liquid extraction with a mixture of N‐hexane–dichloromethane–isopropanol (100:50:5, v/v/v). Isocratic chromatographic separation was performed on a reversed‐phase Discovery C18 column (2.1 × 50 mm, 5 µm). The mobile phase was methanol–water–formic (75:25:0.25, v/v/v). Detection of fenofibric acid and the internal standard (IS) diclofenac acid was achieved by ESI MS/MS in the negative ion mode using m/z 317 → m/z 213 and m/z 294 → m/z 250 transitions, respectively. The method was linear from 0.005 to 1.250 µg/mL when 100 μL plasma was analyzed. The lower limit of quantification was 0.005 µg/mL. The intra‐ and inter‐day precision values were below 8.2%, and accuracy ranged from ?0.9 to 2.1% in all quality control samples. The recovery was 90.3–94.7% and 83.3% for fenofibric acid and IS, respectively. Total run time for each sample analysis was 2.5 min. The validated method was successfully applied to a pharmacokinetic study in six rats after oral administration of fenofibrate, the ester prodrug of fenofibric acid (equivalent to fenofibric acid 5 mg/kg). The method permits laboratory scientists with access to the appropriate instrumentation to perform rapid fenofibric acid determination. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
A simple, sensitive, selective and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of atorvastatin and its active metabolites ortho-hydroxyatorvastatin and para-hydroxyatorvastatin in human plasma using rosuvastatin as internal standard (IS). Following simple liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 559/440 for atorvastatin, m/z 575/466 for ortho-hydroxyatorvastatin, m/z 575/440 for para-hydroxyatorvastatin and m/z 482/258 for the IS. The assay exhibited a linear dynamic range of 0.1-20 ng/mL for atorvastatin and its two metabolites in human plasma. The lower limit of quantification was 100 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of atorvastatin, ortho-hydroxyatorvastatin, para-hydroxyatorvastatin and the IS from spiked plasma samples were 54.2 +/- 3.2, 50.1 +/- 3.8, 65.2 +/- 3.6 and 71.7 +/- 2.7%, respectively. A run time of 2.5 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

8.
Cefuroxime is a second-generation cephalosporin used against different kinds of bacterial infections. To be able to optimize the dosing it is necessary to characterize the pharmacokinetics of cefuroxime which requires a selective and sensitive analytical method for cefuroxime in plasma or serum. A new rapid liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) method, using cefotaxime as internal standard, was developed for analysis of cefuroxime in human serum. The work-up procedure consisted of protein precipitation with acetonitrile/cefotaxime, and after centrifugation the supernatant was dissolved in mobile phase. The sample was injected on a SB-CN column and the detection was performed using tandem mass spectrometry (MS/MS). The limit of quantification was determined to 0.025 microg/mL. The method was linear in the range 0.025-50 microg/mL with a coefficient of correlation >0.999. The limit of quantification and intra-day variability were found to be the same for plasma samples, which indicates that the method is valid for serum as well as plasma samples.  相似文献   

9.
李明昕  王倩  朱婧  任琳  雍莉  邹晓莉 《色谱》2017,35(8):826-831
建立了测定人尿液中尼古丁和可替宁含量的亲水作用色谱-串联质谱(HILIC-MS/MS)方法。尿样加入尼古丁-d4和可替宁-d3同位素内标后,用水稀释10倍,经过滤后的滤液由超高效液相色谱-串联质谱(UPLC-MS/MS)进行分离分析。采用ACQUITY UPLC~BEH HILIC色谱柱(50 mm×3.0 mm,1.7μm),以甲醇和体积分数为0.1%的氨水为流动相,流速为0.2 mL/min,在电喷雾电离源正离子模式下测定尿液中尼古丁和可替宁的含量,用标准曲线法定量。尼古丁和可替宁在1.0~1 000μg/L范围内线性关系良好,相关系数分别为0.994 9和0.995 8;检出限分别为0.082μg/L和0.077μg/L;定量限分别为0.27μg/L和0.26μg/L;加标回收率分别为90.4%~103.5%和93.0%~104.6%;相对标准偏差分别为4.80%~6.21%和4.22%~7.15%。应用所建立的方法测定了200份尿样,结果表明,吸烟人群尿中尼古丁含量为26.68~854.30μg/L,可替宁含量为36.66~1 191.18μg/L(n=86,M_(nicotine)=76.00μg/L,M_(nicotine)=83.52μg/L,M为中位数);非吸烟人群尿中尼古丁含量为5.08~69.66μg/L,可替宁含量为3.16~28.21μg/L(n=114,Mnicotine=7.53μg/L,M_(nicotine)=3.79μg/L)。该方法快速灵敏,操作简单,适用于尿样中尼古丁和可替宁的批量测定,能满足烟草暴露评价的需要。  相似文献   

10.
Lodén H  Amini A 《Electrophoresis》2007,28(10):1548-1556
An efficient and rapid separation method based on reversed-polarity multiple-injection CZE (MICZE), has been developed for the quantification of buserelin in a pharmaceutical product. The determinations were performed by serially injecting five standard solutions of buserelin (50-300 microg/mL) and one reference analyte into a Polybrene-coated capillary. All the samples contained goserelin, an analog peptide to buserelin, as internal standard (IS). Immediately after pressure injection, the applied sample plugs were subjected to electrophoresis for 2 min at -25 kV. Consequently, each sample plug became isolated from its neighboring plugs by the BGE, composed of 100 mM phosphate-triethanolamine buffer at pH 3.0 containing 10% v/v ACN. During separation the individual sample components migrated at similar velocities and as distinct zones through the capillary giving 24 peaks, 12 from the analyte and the IS and 12 from the sample matrix. The buserelin content of the pharmaceutical product was determined to be 0.94 +/- 0.05 mg/mL, which is only a slight deviation from the declared concentration (1 mg/mL).  相似文献   

11.
超高效液相色谱-串联质谱法测定兔血浆中的丝裂霉素C   总被引:1,自引:0,他引:1  
Tang Y  Zhang S  Li X  Sun X  Wen N  Yu M  Peng L  Li J  Li Z  Li B 《色谱》2012,30(2):154-159
建立了采用超高效液相色谱-串联质谱测定兔血浆中丝裂霉素C的方法。以兔空白血浆为基质,通过添加标准溶液的方法配制含丝裂霉素C和内标物曲安奈德的样品,选用乙酸乙酯为提取溶剂,液-液萃取法处理血浆样品。采用Hypersil Gold C18分析柱(50 mm×2.1 mm, 1.9 μm),流动相为甲醇-0.1%甲酸水溶液(90:10, v/v),等度洗脱,流速0.2 mL/min,柱温35 ℃,在3 min内实现了快速分离。采用电喷雾正离子(ESI+)模式电离,选择反应监测(SRM)模式检测,以曲安奈德作为内标物进行定量。用于监测的定量离子对分别为丝裂霉素C m/z 335.2→242.2和曲安奈德m/z 435.2→397.3/415.2,用基质匹配标准溶液法进行定量。结果表明: 兔血浆中丝裂霉素C的质量浓度在1~1000 μg/L范围内线性关系良好(r=0.9978,权重系数(weighting): 1/x2);血浆中丝裂霉素C的检出限(信噪比为3)为0.2 μg/L;其平均回收率为85%~ 115%;日内及日间的相对标准偏差(RSDs)均小于15%,满足生物样品检测的要求。该方法可用于兔气管外壁给药后的血浆样品中丝裂霉素C的检测。本方法选择性强、灵敏度高、操作简便快速、重现性好,适用于丝裂霉素C药代动力学等方面的研究。  相似文献   

12.
建立了高效液相-串联质谱法(LC-MS/MS)分析蔬菜和水果中氟吗啉残留量检测的方法。通过氟吗啉光照实验,研究了氟吗啉顺反异构体转化规律。以醚菌胺为内标(I.S.),乙酸乙酯提取,经HLB(亲水-疏水净化住)固相萃取小柱净化并富集后,以液相色谱分离,采用质谱正离子多反应监测模式进行定量分析。方法定量限为0.05μg/kg;线性范围为0.05~25μg/kg;提取回收率为77.64%~92.83%;相对标准偏差均小于8.6%。本方法灵敏度高、选择性好,实际样品检测中的检出率达到70%;样品中最高残留量为1.83μg/kg,能满足蔬菜和水果中氟吗啉残留量检测要求。  相似文献   

13.
Sucrose esters (SEs) from oriental tobacco are normally characterized by gas chromatography/mass spectrometry (GC/MS) after a long saponification and derivatization procedure. To simplify the process, a rapid method has been developed by using liquid chromatography coupled with electrospray ion trap mass spectrometry (LC/ESI-MSn). Using the characteristic fragmentation behavior of abundant SEs identified by GC/MS after purification by gel permeation chromatography (GPC) from cuticular waxes of green oriental tobacco leaf, two types of SEs from green and cured oriental tobacco were identified by MSn analysis. The first is one of three types reported formerly and has 13 SE homologues. However, the presence of unsaturation in one of the acyl substituents of this first type gave rise to a new series with three homologues. The other was found to be a new type and had three homologues. The proposed method enables the rapid and sensitive characterization of SEs from oriental tobacco.  相似文献   

14.
Methyl-3-quinoxaline-2-carboxylic acid (MQCA) is the last major remaining detectable metabolite of Olaquindox in animal tissue. A rapid, sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the detection and quantification of MQCA in fish tissue using deuterated quinoxaline-2-carboxylic acid (d(4)-QCA) as internal standard. Various parameters affecting sample preparation, LC separation and MS/MS detection were investigated, and the optimal conditions concerned were determined. Fish tissue samples were subject to hydrochloric acid hydrolysis followed by Oasis MAX solid-phase extraction clean-up; analysis was performed using UPLC coupled to electrospray MS/MS. The chromatographic separation was achieved in less than 5 min. The limit of detection and the limit of quantification were 0.1 and 0.25 ng/g, respectively. The average recoveries of MQCA, spiked at levels of 0.25-50.0 ng/g, were from 92.7 to 104.3%. The relative standard deviation values were <6%. The validated method was successfully applied to analyze 60 batch samples collected from the local market.  相似文献   

15.
A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of pramipexole in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H](+) ions, m/z 212/152 for pramipexole and m/z 409/228 for the IS. The method exhibited a linear dynamic range of 200-8000 pg/mL for pramipexole in human plasma. The lower limit of quantification was 200 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 3.5 min for each sample made it possible to analyze more than 200 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

16.
Hou J  Xie W  Chen X  Xi J  Qian Y  Wang F  Liu H 《色谱》2011,29(6):535-542
建立了采用固相萃取-液相色谱-质谱/质谱(SPE-LC-MS/MS)对蜂蜜中磺胺类、硝基咪唑类、喹诺酮类、大环内酯类、林可酰胺类和吡喹酮共计6大类54种药物残留同时测定的方法。蜂蜜经磷酸盐缓冲溶液(pH 8)稀释,Oasis HLB固相萃取柱净化后,通过液相色谱-质谱联用技术进行检测(正离子方式,多反应监测模式)。采用同位素稀释内标法或外标法进行定量,线性关系良好,相关系数大于0.992。方法的定量限(LOQ,以信噪比(S/N)大于10计)分别为磺胺类和硝基咪唑类药物1.0 μg/kg,喹诺酮类和林可酰胺类药物2.0 μg/kg,大环内酯类药物3.0 μg/kg,吡喹酮0.3 μg/kg。总体回收率为32.6%~114%,相对标准偏差为1.3%~28.9%。该方法的定量限满足目前国内外药物的最大残留限量要求,可作为蜂蜜中相关药物残留量的筛选检测方法。  相似文献   

17.
p‐Cresol sulfate (pCS) and indoxyl sulfate (IS) are protein‐bound uremic toxins that accumulate in patients with chronic kidney disease (CKD). They are closely associated with the mortality rate of CKD and morbidity of cardiovascular disease. In the present study, we established a rapid method for determination of pCS and IS by HPLC‐MS/MS in serum samples from 205 CKD patients undergoing peritoneal dialysis. In brief, serum was extracted by acetonitrile and spiked with hydrochlorothiazide. The prepared sample was eluted through HPLC column (Agilent Zorbax SB‐C18, 3.5 μm, 2.1 × 100 mm) with a mobile phase of acetonitrile and 10 mm ammonium acetate solution (10:90, v/v) for subsequent detection of pCS and IS by MS/MS. The linearity ranged from 50 to 10,000 ng/mL for pCS (r > 0.99), and from 500 to 10,000 ng/mL for IS (r > 0.99). The lower limit of quantification was 50 ng/mL for pCS, and 500 ng/mL for IS. Relative standard deviation (RSD) of intra‐ and inter‐day precision was within ±15%. The results showed that pCS and IS levels were partially correlated with renal function in CKD patients, and IS was directly related to serum creatinine and estimated glomerular filtration rate.  相似文献   

18.
Erythrocyte alkylresorcinols (5‐alkyl‐1,3‐dihydroxybenzenes) are potential biomarkers of wholegrain wheat and rye intake. However, their high‐throughput quantitative analysis by gas chromatography/mass spectrometry (GC/MS) is hindered by the time‐consuming sample preparation and, more importantly, by interfering compounds that still remain after sample cleanup. In the present work we describe a gas chromatography/tandem mass spectrometry (GC/MS/MS) method for the rapid and reliable quantification of alkylresorcinols in erythrocyte samples. The performance of the GC/MS/MS method is compared with that of GC/MS. The main characteristics of the method are: lower limits of detection: 2–10 µg/L standard solution; lower limits of quantification: 6–30 µg/L standard solution; linearity coefficients: 0.9611–0.9888; linear ranges: 2–20 µg/L in erythrocytes; and intra‐day precisions (n = 6): 4–13% at endogenous analyte levels in non‐spiked erythrocytes. Tandem mass spectrometry showed greatly improved selectivity over single‐stage mass spectrometry in the case of erythrocyte samples, eliminating all interferences detectable in single‐stage MS and enabling simple peak integration for quantification. Moreover, increased selectivity resulted in GC separation speeded up by a factor of two, allowing the duplicate analysis of over 40 samples per day. This GC/MS/MS method is suggested as an improved alternative to GC/MS for the quantification of alkylresorcinols in erythrocytes for assessing wholegrain wheat and rye intake. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
A rapid, sensitive and specific high-performance liquid chromatography/electrospray ionization mass spectrometric (LC-ESI-MS) method was developed and validated for the quantification of madecassoside, a major active constituent of Centella asiatica (L.) Urb. herbs, in rat plasma. With paeoniflorin as an internal standard (IS), a simple liquid-liquid extraction process was employed for the plasma sample preparation. Chromatographic separation was achieved within 6 min on a Shim-pack CLC-ODS column using acetonitrile and water (60:40, v/v) containing 0.1% (v/v) formic acid as the mobile phase. The detection was performed by MS with electrospray ionization interface in negative selected ion monitoring (SIM) mode. The linear range was 11-5500 ng/mL with the square regression coefficient (r(2) ) of 0.9995. The lower limit of quantification was 11 ng/mL. The intra- and inter- day precision ranged from 4.99 to 9.03%, and the accuracy was between 95.82 and 111.80%. The average recoveries of madecassoside and IS from spiked plasma samples were >92%. The developed method was successfully applied to the pharmacokinetic study of madecassoside in rats after an oral administration.  相似文献   

20.
A simple and reproducible HPLC method for quantification of hydroxysafflor yellow A (HSYA) in rat plasma and tissues after oral administration of safflower extract or safflor yellow (SY) was developed. Sample preparation was achieved by protein precipitation of plasma and tissue homogenates with three volumes of methanol. p-Hydroxybenzaldehyde was used as the internal standard (IS). HSYA and IS were separated on a Hypersil BDS-C(18) column with a gradient elution system composed of acetonitrile and aqueous acetic acid. UV detection was used at 320 nm. The calibration curves were linear in all matrices (r(2) > 0.999) in the concentration ranges 0.51-101.36 microg/mL for plasma, 12.27-2454.46 microg/g for intestines and 0.96-192.20 microg/g for lung. The intra-day and inter-day precision were all less than 12.5%, and the extract recovery was in the range 64.1-103.7% with RSD less than 15.6% for HSYA in all matrices. The method was used successfully to quantify HSYA in rat plasma and tissue samples to support a pharmacokinectic study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号