首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An on-line flow injection spectrofluorimetric method for the direct determination of aluminium in water samples is described. The method is based on the reaction of aluminium with N-o-vanillidine-2-amino-p-cresol (OVAC) in acidic medium at pH 4.0 to form a water-soluble complex. The excitation and emission wavelengths were 423.0 and 553.0 nm, respectively, at which the OVAC-Al complex gave the maximum fluorescence intensity at pH 4.0 in a 50% methanol-50% water medium at 50 °C. An interference from fluoride ions was minimised by the addition of Be2+. Other ions were found not to interfere at the concentrations likely to be found in natural waters. The proposed methods were validated in terms of linearity, repeatability, detection limit, accuracy and selectivity. Under these conditions, the calibration was linear up to 1000 μg L−1 (r = 0.999). The limit of detection (3σ) for the determination of Al(III) was 0.057 μg L−1 and the precision for multiple determinations of 3 ng mL−1 Al(III) prepared in ultra-pure water was found to be 0.62% (n = 10).The Schiff base ligand could be used to determine ultra-trace aluminium from natural waters. Analysis of environmental certified reference materials showed good agreement with the certified values. The procedure was found to be equally applicable to both freshwater and saline solutions, including seawater.  相似文献   

2.
A gas chromatography–mass spectrometric (GC–MS) method has been established for the determination of hydrazine in drinking water and surface water. This method is based on the derivatization of hydrazine with ortho-phthalaldehyde (OPA) in water. The following optimum reaction conditions were established: reagent dosage, 40 mg mL−1 of OPA; pH 2; reaction for 20 min at 70 °C. The organic derivative was extracted with methylene chloride and then measured by GC–MS. Under the established condition, the detection and the quantification limits were 0.002 μg L−1 and 0.007 μg L−1 by using 5.0-mL of surface water or drinking water, respectively. The calibration curve showed good linearity with r2 = 0.9991 (for working range of 0.05–100 μg L−1) and the accuracy was in a range of 95–106%, and the precision of the assay was less than 13% in water. Hydrazine was detected in a concentration range of 0.05–0.14 μg L−1 in 2 samples of 10 raw drinking water samples and in a concentration range of 0.09–0.55 μg L−1 in 4 samples of 10 treated drinking water samples.  相似文献   

3.
Methods for short-term BOD analysis (BODst) based on ferricyanide mediator reduction have succeeded in overcoming some problems associated with the standard BOD test analysis (BOD5) such as long-term incubations (5 days), the need to dilute samples and low reproducibility. Here we present a bioassay where a Klebsiella pneumoniae environmental strain successfully reduces ferricyanide without de-aeration of the samples with linear BOD5 ranges between 30 and 500 mg L−1 or 30 and 200 mg L−1, using glucose-glutamic acid solution (GGA) or OECD standards respectively. We further propose a new assay termination solution that allows higher reproducibility and standardization of the cell-based assay, employing formaldehyde (22.7 g L−1) or other compounds in order to stop ferricyanide reduction without affecting the amperometric detection and therefore replace the centrifugation step normally used to stop microbial-driven reactions in ferricyanide-mediated bioassays. These improvements led to an accurate determination of real municipal wastewater samples.  相似文献   

4.
In this study a new method for determination of cadmium in alcohol fuel using Moringa oleifera seeds as a biosorbent in an on-line preconcentration system coupled to flame atomic absorption spectrometry (FAAS) was developed. Flow and chemical variables of the proposed system were optimized through multivariate designs. The limit of detection for cadmium was 5.50 μg L−1 and the precision was below 2.3% (35.0 μg L−1, n = 9). The analytical curve was linear from 5 to 150 μg L−1, with a correlation coefficient of 0.9993. The developed method was successfully applied to spiked alcohol fuel, and accuracy was assessed through recovery tests, with recovery ranging from 97.50 to 100%.  相似文献   

5.
This work reports the preparation of molecularly imprinted polymer (MIP) particles for selective extraction and determination of selenium ions from aqueous media. Polymerization was achieved in a glass tube containing SeO2, o-phenylenediamine, 2-vinylpyridine (VP), ethyleneglycoldimethacrylate (EDMA), 2,2′-azobisisobutyronitrile (AIBN). The polymer block obtained was ground and sieved (55-75 μm) and the Se-o-phenylenediamine complex was removed from polymer particles by leaching with 2 M of HCl, which leaves a cavity in the polymer particles. The polymer particles both prior to and after leaching have been characterized by IR and thermogravimetric (TG) studies. The effect of different parameters, such as pH, extraction time, type and least amount of eluent for elution of complex from polymer were evaluated. Extraction efficiencies >99% were obtained by elution of the polymers with 15 mL of methanol-acetonitrile mixture (1:2, v/v). The limit of detection of the proposed method followed by hydride generation atomic absorption spectroscopy (HG-AAS) was found to be 3.3 μg L−1 and a dynamic linear range (DLR) of 10-200 μg L−1 was obtained. The relative standard deviations (R.S.D.s) at 30.0 μg L−1 of Se were below than 8.1%. The influence of various cationic interferences on percent recovery of complex was studied. The method was applied to the recovery and determination of selenium in different real samples.  相似文献   

6.
Liu Y  Chang X  Wang S  Guo Y  Din B  Meng S 《Talanta》2004,64(1):160-166
A highly sensitive and selective solid-phase spectrophotometric method for the determination of sub-μg l−1 level nickel(II) is described. Nickel(II) was sorbed on a styrene-divinylbenzene-type resin Amberlite XAD-4 as a Ni(II)-o-carboxylphenyldiazoaminoazobenzene (o-CDAA) complex. At pH 9.0, resin phase absorbances at 588 and 800 nm were measured directly with an apparent molar absorptivity of 2.95×107 g mol−1 cm−1. The linear range of the determination was 1.2-41 μg g−1 resin. The detection limit and the quantification limit were found to be 0.24 and 0.76 μg g−1 resin, respectively. The relative standard deviation of 10 replicate determinations of 1.0 μg nickel(II) in 100 ml sample was of 1.5%. The tolerance limit of coexistent ions was also investigated. Most of them are in tolerable amount. For practical analyses, 1 ml acetylacetone used can eliminate the interferences caused by Cu and Fe. The procedure was validated by analysis a certified water reference material (GBW 08618 Beijing, China) and a tomato leaf certified reference material (GBW 08402 Beijing, China) with the results in agreement with the certified values. The method was applied to the determination of nickel(II) in water and vegetable samples with satisfactory results.  相似文献   

7.
A novel dichloro zinc complex (L1)ZnCl2, where L1 is N,N′-bis-(2,6-dichloro-benzyl)-(R,R)-1,2-diaminocyclohexane, has been synthesized and characterized. The dimethyl derivatives, generated in situ from the well characterized dichloro zinc complexes (L1)ZnCl2 and (L2)ZnCl2, where L2 is N,N′-bis-(benzyl)-(R,R)-1,2-diaminocyclohexane, were employed as initiators for the ring opening polymerization (ROP) of rac-lactide (rac-LA). The complexes were found to be highly efficient initiators yielding the polylactide (PLA) with a narrow molecular weight distribution. The catalytic activity and heterotactic selectivity of the Zn(II) complexes were affected by the substituents on the phenyl groups of benzyl moieties in (R,R)-1,2-diaminocyclohexane. The dimethyl derivative of (L2)ZnCl2 produced highly stereocontrolled PLA with Pr = 0.75 at −25 °C.  相似文献   

8.
9.
The cell-sorption of paramagnetic ions of Mn2+ and Cr3+ onto a Chlorella vulgaris(C. vulgaris) cell-immobilized micro-column was significantly improved in the presence of an external magnetic field generated in a finite solenoid, by placing the micro-column in the center of the solenoid in a sequential injection system. Magnetic field creates an opposite drift velocity on the hydrated paramagnetic ions against the flow of the sample zone, retards the moving velocity of the metal ions and provides extra contacting time with the cells on the micro-column and offers more chances for the paramagnetic ions to interact with the various functional groups or binding sites on the cell surface, which significantly facilitates cell-sorption of the paramagnetic ions. The sorption efficiencies of Mn2+ and Cr3+ at the 20 μg L−1 level were improved from 45 to 80% and 60 to 90%, respectively, in a magnetic field of 240 mT.The system was applied for the separation/preconcentration of ultra-trace level of manganese. The presence of an external magnetic field significantly alleviated the interfering effects from coexisting metal ions. Within a liner range of 0.025-0.5 μg L−1 and a sampling volume of 500 μL, an enrichment factor of 21.2, a limit of detection of 0.008 μg L−1, along with a sampling frequency of 20 h−1 was attained, achieving a precision of 2.1% R.S.D. (0.2 μg L−1). Manganese contents in a certified reference material of riverine water and a snow water were analyzed.  相似文献   

10.
Baytak S  Zereen F  Arslan Z 《Talanta》2011,84(2):319-323
A trace element preconcentration procedure is described utilizing a minicolumn of yeast (Yamadazyma spartinae) immobilized TiO2 nanoparticles for determination of Cr, Cu, Fe, Mn, Ni and Zn from water samples by inductively coupled plasma atomic emission spectrometry. The elements were quantitatively retained on the column between pH 6 and 8. Elution was made with 5% (v/v) HNO3 solution. Recoveries ranged from 98 ± 2 (Cr) to 100 ± 4 (Zn) for preconcentration of 50 mL multielement solution (50 μg L−1). The column made up of 100 mg sorbent (yeast immobilized TiO2 NP) offers a capacity to preconcentrate up to 500 mL of sample solution to achieve an enrichment factor of 250 with 2 mL of 5% (v/v) HNO3 eluent. The detection limits obtained from preconcentration of 50 mL blank solutions (5%, v/v, HNO3, n = 11) were 0.17, 0.45, 0.25, 0.15, 0.33 and 0.10 μg L−1 for Cr, Cu, Fe, Mn, Ni and Zn, respectively. Relative standard deviation (RSD) for five replicate analyses was better than 5%. The retention of the elements was not affected from up to 500 μg L−1 Na+ and K+ (as chlorides), 100 μg L−1 Ca2+ (as nitrate) and 50 μg L−1 Mg2+ (as sulfate). The method was validated by analysis of freshwater standard reference material (SRM 1643e) and applied to the determination of the elements from tap water and lake water samples.  相似文献   

11.
Liang Y  Liu XJ  Liu Y  Yu XY  Fan MT 《Analytica chimica acta》2008,615(2):174-183
A general and broad class-specific enzyme-linked immunosorbent assay was developed for the O,O-dimethyl organophosphorus pesticides, including malathion, dimethoate, phenthoate, phosmet, methidathion, fenitrothion, methyl parathion and fenthion. Three haptens with different spacer-arms were synthesized. The haptens were conjugated to bovine serum albumin (BSA) for immunogens and to ovalbumin (OVA) for coating antigens. Rabbits were immunized with the immunogens and six polyclonal antisera were produced and screened against each of the coating antigens using competitive indirect enzyme-linked immunosorbent assay for selecting the proper antiserum. The effect of hapten heterology on immunoassay sensitivity was also studied. The antibody-antigen combination with the most selectivity for malathion was further optimized and tested for tolerance to co-solvent, pH and ionic strength changes. The IC50 values, under optimum conditions, were estimated to be 30.1 μg L−1for malathion, 28.9 μg L−1 for dimethoate, 88.3 μg L−1 for phenthoate, 159.7 μg L−1 for phosmet, 191.7 μg L−1 for methidathion, 324.0 μg L−1 for fenitrothion, 483.9 μg L−1 for methyl parathion, and 788.9 μg L−1 for fenthion. Recoveries of malathion, dimethoate, phenthoate, phosmet and methidathion from fortified Chinese cabbage samples ranged between 77.1% and 104.7%. This assay can be used in monitoring studies for the multi-residue determination of O,O-dimethyl organophosphorus pesticides.  相似文献   

12.
This paper presents the quantification of Penicillin V and phenoxyacetic acid, a precursor, inline during Pencillium chrysogenum fermentations by FTIR spectroscopy and partial least squares (PLS) regression and multivariate curve resolution – alternating least squares (MCR-ALS). First, the applicability of an attenuated total reflection FTIR fiber optic probe was assessed offline by measuring standards of the analytes of interest and investigating matrix effects of the fermentation broth. Then measurements were performed inline during four fed-batch fermentations with online HPLC for the determination of Penicillin V and phenoxyacetic acid as reference analysis. PLS and MCR-ALS models were built using these data and validated by comparison of single analyte spectra with the selectivity ratio of the PLS models and the extracted spectral traces of the MCR-ALS models, respectively. The achieved root mean square errors of cross-validation for the PLS regressions were 0.22 g L−1 for Penicillin V and 0.32 g L−1 for phenoxyacetic acid and the root mean square errors of prediction for MCR-ALS were 0.23 g L−1 for Penicillin V and 0.15 g L−1 for phenoxyacetic acid. A general work-flow for building and assessing chemometric regression models for the quantification of multiple analytes in bioprocesses by FTIR spectroscopy is given.  相似文献   

13.
A novel technique, high temperature headspace liquid-phase microextraction (HS-LPME) with room temperature ionic liquid (RTIL), 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) as extractant, was developed for the analysis of dichlorodiphenyltrichloroethane (p,p′-DDT and o,p′-DDT) and its metabolites including 4,4′-dichlorodiphenyldichloroethylene (p,p′-DDE) and 4,4′-dichlorodiphenyldichloroethane (p,p′-DDD) in water samples by high performance liquid chromatography with ultraviolet detection. The parameters such as salt content, sample pH and temperature, stirring rate, extraction time, microdrop volume, and sample volume, were found to have significant influence on the HS-LPME. The conditions optimized for extraction of target compounds were as follows: 35% NaCl (w/v), neutral pH condition, 70 °C, 800 rpm, 30 min, 10 μL [C4MIM][PF6], and 25 mL sample solutions. Under the optimized conditions, the linear range, detection limit (S/N = 3), and precision (R.S.D., n = 6) were 0.3-30 μg L−1, 0.07 μg L−1, and 8.0% for p,p′-DDD, 0.3-30 μg L−1, 0.08 μg L−1, and 7.1% for p,p′-DDT, 0.3-30 μg L−1, 0.08 μg L−1, and 7.2% for o,p′-DDT, and 0.2-30 μg L−1, 0.05 μg L−1, and 6.8% for p,p′-DDE, respectively. Water samples including tap water, well water, snow water, reservoir water, and wastewater were analyzed by the proposed procedure and the recoveries at 5 μg L−1 spiked level were in the range of 86.8-102.6%.  相似文献   

14.
A novel Fe3O4–poly(aniline-naphthylamine)-based nanocomposite was synthesized by chemical oxidative polymerization process as a magnetic sorbent for micro solid phase extraction. The scanning electron microscopy images of the synthesized nanocomposite revealed that the copolymer posses a porous structure with diameters less than 50 nm. The extraction efficiency of this sorbent was examined by isolation of rhodamine B, a mutagenic and carcinogenic dye, from aquatic media in dispersion mode. Among different synthesized polymers, Fe3O4/poly(aniline-naphthylamine) nanocomposite showed a prominent efficiency. Parameters including the desorption solvent, amount of sorbent, desorption time, sample pH, ionic strength, extraction time and stirring rate were optimized. Under the optimum condition, a linear spiked calibration curve in the range of 0.35–5.00 μg L−1 with R2 = 0.9991 was obtained. The limits of detection (3Sb) and limits of quantification (10Sb) of the method were 0.10 μg L−1 and 0.35 μg L−1 (n = 3), respectively. The relative standard deviation for water sample with 0.5 μg L−1 of RhB was 4.2% (n = 5) and the absolute recovery was 92%. The method was applied for the determination of rhodamine B in dishwashing foam, dishwashing liquid, shampoo, pencil, matches tips and eye shadows samples and the relative recovery percentage were in the range of 94–99%.  相似文献   

15.
A gas chromatographic–positive chemical ionisation-tandem mass spectrometric (GC–PCI-MS/MS) method for the simultaneous determination of 10 oxidative metabolites of the monoterpenoid hydrocarbons α-pinene, (R)-limonene, and Δ3-carene ((+)-3-carene) in human urine was developed and tested for the monoterpene biomonitoring of the general population (n = 36). The method involves enzymatic cleavage of the glucuronides followed by solid-supported liquid–liquid extraction and derivatisation using a two-step reaction with N,O-bis(trimethylsilyl)-trifluoroacetamide and N-(trimethylsilyl)imidazole. The method proved to be both sensitive and reliable with detection limits ranging from 0.1 to 0.3 μg L−1. In contrast to the frequent and distinct quantities of (1S,2S,4R)-limonene-1,2-diol, the (1R,2R,4R)-stereoisomer could not be detected. The expected metabolite of (+)-3-carene, 3-caren-10-ol was not detected in any of the samples. All other metabolites were detected in almost all urine samples.  相似文献   

16.
A single-drop microextraction (SDME) procedure was developed for the analysis of organophosphorus and pyrethroid pesticides in water by gas chromatography (GC) with flame ionization detection (GC-FID). The significant parameters that affect SDME performance, such as the selection of microextraction solvent, solvent volume, extraction time, and stirring rate, were studied and optimized using a tool screening factorial design. The limits of detection (LODs) in water for the four investigated compounds were between 0.3 and 3.0 μg L−1, with relative standard deviations ranging from 7.7 to 18.8%. Linear response data were obtained in the concentration range of 0.9-6.0 μg L−1 (λ-cyhalothrin), 3.0-60.0 μg L−1 (methyl parathion), 9.0-60.0 μg L−1 (ethion), and 9.0-30.0 μg L−1 (permethrin), with correlation coefficients ranging from 0.9337 to 0.9977. The relative recoveries for the spiked water ranged from 73.0 to 104%. Environmental water samples (n = 26) were successfully analyzed using the proposed method and methyl parathion presented concentration up to 2.74 μg L−1. The SDME method, coupled with GC-FID analysis, provided good precision, accuracy, and reproducibility over a wide linear range. Other highlights of the method include its ease of use and its requirement of only small volumes of both organic solvent and sample.  相似文献   

17.
A highly sensitive flow analysis system has been developed for the trace determination of reactive phosphate in natural waters, which uses a polymer inclusion membrane (PIM) with Aliquat 336 as the carrier for on-line analyte separation and preconcentration. The system operates under flow injection (FI) and continuous flow (CF) conditions. Under optimal FI conditions the system is characterised by a linear concentration range between 0.5 and 1000 μg L−1 P, a sampling rate of 10 h−1, a limit of detection of 0.5 μg L−1 P and RSDs of 3.2% (n = 10, 100 μg L−1) and 7.7% (n = 10, 10 μg L−1). Under CF conditions with 10 min stop-flow time and sample solution flow rate of 1.32 mL min−1 the flow system offers a limit of detection of 0.04 μg L−1 P, a sampling rate of 5 h−1 and an RSD of 3.4% (n = 5, 2.0 μg L−1). Interference studies revealed that anions commonly found in natural waters did not interfere when in excess of at least one order of magnitude. The flow system, operating under CF conditions, was successfully applied to the analysis of natural water samples containing concentrations of phosphate in the low μg L−1 P range, using the multipoint standard addition method.  相似文献   

18.
Two methods of the determination of cobalt and chromium in human urine of non-occupationally exposed populations—highly sensitive catalytic adsorptive stripping voltammetry (CAdSV) and electrothermal atomic absorption spectrometry (ET-AAS)—are evaluated and compared. The CAdSV methods are based on adsorptive accumulation of a cobalt-nioxime (1,2-cyclohexanedione dioxime) or a chromium-DTPA (diethylenetriammine-N,N,N′,N″,N″-pentaacetic acid) complexes on a hanging mercury drop electrode, followed by a stripping voltammetric measurement of the catalytic reduction current of the adsorbed complex in the presence of sodium nitrite in case of cobalt or in the presence of sodium nitrate in case of chromium determination. In the CAdSV procedure UV-photolysis was used for the sample pre-treatment; the ET-AAS determination did not require any separate preliminary decomposition of the analyte urine samples. The accuracy of the procedures was checked by the analysis of commercially available quality control urine samples. The detection limits (3σ) were 0.13 μg l−1 for Co and 0.18 μg l−1 for Cr in ET-AAS determination and 0.007 μg l−1 for Co and 0.002 μg l−1 for Cr in CAdSV measurements. Precision (R.S.D.) was less than 5% for both methods. The study has shown that the CAdSV is a more reliable and sensitive technique for the determination of very low cobalt and chromium contents in urine, the detection of which is not possible when using the AAS technique.  相似文献   

19.
Zhou Q  Gao Y  Xie G 《Talanta》2011,85(3):1598-1602
Present study described a simple, sensitive, and viable method for the determination of bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol in water samples using temperature-controlled ionic liquid dispersive liquid-phase microextraction coupled to high performance liquid chromatography-fluorescence detector. In this experiment, 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) was used as the extraction solvent, and bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol were selected as the model analytes. Parameters affecting the extraction efficiency such as the volume of [C8MIM][PF6], dissolving temperature, extraction time, sample pH, centrifuging time and salting-out effect have been investigated in detail. Under the optimized conditions, good linear relationship was found in the concentration range of 1.0-100 μg L−1 for BPA, 1.5-150 μg L−1 for 4-NP, and 3-300 μg L−1 for 4-OP, respectively. Limits of detection (LOD, S/N = 3) were in the range of 0.23-0.48 μg L−1. Intra day and inter day precisions (RSDs, n = 6) were in the range of 4.6-5.5% and 8.5-13.3%, respectively. This method has been also successfully applied to analyze the real water samples at two different spiked concentrations and excellent results were obtained.  相似文献   

20.
A new biochemical oxygen demand (BOD) sensing method employing a double-mediator (DM) system coupled with ferricyanide and a lipophilic mediator, menadione and the eukaryote Saccharomyces cerevisiae has been developed. In this study, a stirred micro-batch-type microbial sensor with a 560 μL volume and a two-electrode system was used. The chronamperometric response of this sensor had a linear response between 1 μM and 10 mM hexacyanoferrate(II) (r2 = 0.9995, 14 points, n = 3, average of relative standard deviation and R.S.D.av = 1.3%). Next, the optimum conditions for BOD estimation by the DM system (BODDM) were investigated and the findings revealed that the concentration of ethanol, used to dissolve menadione, influenced the sensor response and a relationship between the sensor output and glucose glutamic acid concentration was obtained over a range of 6.6-220 mg O2 L−1 (five points, n = 3, R.S.D.av 6.6%) when using a reaction mixture incubated for 15 min. Subsequently, the characterization of this sensor was studied. The sensor responses to 14 pure organic substances were compared with the conventional BOD5 method and other biosensor methods. Similar results with the BOD biosensor system using Trichosporon cutaneum were obtained. In addition, the influence of chloride ion, artificial seawater and heavy metal ions on the sensor response was investigated. A slight influence of 20.0 g L−1 chloride ion and artificial seawater (18.4 g L−1 Cl) was observed. Thus, the possibility of BOD determination for seawater was suggested in this study. In addition, no influence of the heavy metal ions (1.0 mg L−1 Fe3+, Cu2+, Mn2+, Cr3+ and Zn2+) was observed. Real sample measurements using both river water and seawater were performed and compared with those obtained from the BOD5 method. Finally, stable responses were obtained for 14 days when the yeast suspension was stored at 4 °C (response reduction, 93%; R.S.D. for 6 testing days, 9.1%).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号