首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A miniaturized on-column digestion system constructed for the sequential analysis of semi-purified protein analytes is presented. By utilizing fused silica capillary (diameter 150microm) packed with a zone of trypsin-modified Eupergit C beads and a second zone of reversed-phase C18 material, a linear column set-up was constructed. The protein analytes (pmol amounts) were first digested in the 600nl trypsin reactor portion of the system. Next, the generated peptides were trapped in the C18 column shaped as an electrospray emitter. Finally, after washing the matrix free from salts and other hydrophilic impurities present in the sample, peptides were eluted. A stepwise increased concentration profile of organic solvent, created by a dual syringe pump system, promoted the release of bound peptides, which were identified by electrospray ionization MS/MS. This approach proved to be very efficient, achieving almost complete digestion of the proteins studied, with suitable operational stability maintained for more than 1 week. Further, a small nebulizer was designed and fitted to the electrospray emitter. A significant improvement of the spray stability was observed and droplet build-up on the capillary was avoided, even at flow rates well above 1500nl/min. The proteins chloroperoxidase, staphylococcal enterotoxin B and protein A (injection volume 0.3microl, salt concentration 0.2-1M) were sequentially digested, desalted, eluted, detected and conclusively identified by bioinformatics web tools with an analytical cycle time of 10min.  相似文献   

2.
Al-Lawati H  Watts P  Welham KJ 《The Analyst》2006,131(5):656-663
A highly efficient protein digestion device has been fabricated using commercially available immobilized trypsin on agarose beads, packed into a silica capillary and connected either directly to an electrospray mass spectrometer via a 'microtight T' connector, from which aqueous acetic acid (0.2%) was pumped, or via a monolithic column connected to the mass spectrometer ion source. Six proteins with molecular mass ranging from 2848 to 77703 Da were digested completely using this system. In the second set of experiments a short monolithic separation column was placed after the immobilized trypsin capillary and partial separation of the generated peptides was obtained. The detection limits were increased from the micromol to pmol range by utilization of this separation column. Gradient elution, using a binary HPLC pump and a flow splitter, was used to optimize the peptide separation. This provided significantly enhanced resolution of the tryptic peptides but increased the analysis time to 30 minutes.  相似文献   

3.
In this study, methodology was developed for on-line and miniaturized enzymatic digestion with liquid chromatographic (LC) separation and mass spectrometric (MS) detection. A packed capillary LC-MS system was combined with on-line trypsin cleavage of a model protein, lactate dehydrogenase, to provide an efficient system for peptide mapping. The protein was injected onto an enzymatic capillary reactor and the resulting peptides were efficiently trapped on a capillary trapping column. Different trapping columns were evaluated to achieve a high binding capacity for the peptides generated in the enzyme reactor. The peptides were further eluted from the pre-column and separated on an analytical capillary column by a buffer more suitable for the following an electrospray ionisation (ESI) MS process. An important aspect of the on-line approach was the desalting of peptides performed in the trapping column to avoid detrimental signal suppression in the ESI process. The developed on-line system was finally compared to a classical digestion in solution, with reference to peptide sequence coverage and sensitivity. It was shown that the on-line system gave more than 100% higher peptide sequence coverage than traditional digestion methods.  相似文献   

4.
Zhang P  Gao M  Zhu S  Lei J  Zhang X 《Journal of chromatography. A》2011,1218(47):8567-8571
In this report, laser radiation (808nm) for the first time was employed to enhance the efficiency of proteolysis through immobilized enzyme reactor (IMER). IMER based monolithic support was prepared in the fused-silica capillary via a simple two-step procedure including acryloylation on trypsin surface and in situ aqueous polymerization/immobilization. The feasibility and high efficiency of the laser-assisted IMER were demonstrated by the digestion of bovine serum albumin (BSA), cytochrome c (Cyt-c) and β-casein. The digestion process was achieved in 60s. The peptides were identified by MALDI-TOF-MS, yielding the sequence coverage of 33% for BSA, 73% for Cyt-c and 22% for β-casein. The comparisons between the in-solution digestion and on IMER reaction with/without laser assistance were made. To further confirm its efficiency in proteome analysis, the laser-assisted IMER was also applied to the analysis of one fraction of human serum sample through two-dimensional (2-D) separation of strong anion exchange/reversed-phase liquid chromatography (SAX/RPLC). After a database search, 49 unique peptides corresponding to 5 proteins were identified. The results showed that the laser-assisted IMER provides a promising platform for the high-throughput protein identification.  相似文献   

5.
Microchip-based proteomic analysis requires proteolytic digestion of proteins in microdevices. Enzyme reactors in microdevices, fabricated in glass, silicon, and PDMS substrates, have recently been demonstrated for model protein digestions. The common approach used for these enzyme reactors is employment of a syringe pump(s) to generate hydrodynamic flow, driving the proteins through the reactors. Here we present a novel approach, using electroosmotic flow (EOF) to electrokinetically pump proteins through a proteolytic system. The existence of EOF in the proteolytic system packed with immobilized trypsin gel beads was proven by imaging the movement of a neutral fluorescent marker. Digestions of proteins were subsequently carried out for 12 min, and the tryptic peptides were analyzed independently using capillary electrophoresis (CE) and MALDI-TOF mass spectrometry (MS). The results from CE analysis of the tryptic peptides from the EOF-driven proteolytic system and a conventional water bath digestion were comparable. MALDI-TOF MS was used to identify the parent protein and the tryptic peptides using MS-Fit database searching. The potential utility of the EOF-driven proteolytic system was demonstrated by direct electro-elution of proteins from an acrylamide gel into the proteolytic system, with elution and tryptic digestion achieved in a single step. The EOF-driven proteolytic system, thus, provides a simple way to integrate protein digestion into an electrophoretic micro total analysis system for protein analysis and characterization.  相似文献   

6.
Simpson DC  Smith RD 《Electrophoresis》2005,26(7-8):1291-1305
Mass spectrometry (MS)-based proteomics is currently dominated by the analysis of peptides originating either from digestion of proteins separated by two-dimensional gel electrophoresis (2-DE) or from global digestion; the simple peptide mixtures obtained from digestion of gel-separated proteins do not usually require further separation, while the complex peptide mixtures obtained by global digestion are most frequently separated by chromatographic techniques. Capillary electrophoresis (CE) provides alternatives to 2-DE for protein separation and alternatives to chromatography for peptide separation. This review attempts to elucidate how the most promising CE modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), might best be applied to MS-based proteomics. CE-MS interfacing, mass analyzer performance, column coating to minimize analyte adsorption, and sample stacking for CZE are considered prior to examining numerous applications. Finally, multidimensional systems that incorporate CE techniques are examined; CZE often finds use as a fast, final dimension before ionization for MS, while CIEF, being an equilibrium technique, is well-suited to being the first dimension in automated fractionation systems.  相似文献   

7.
2-DE combined with LC-MS/MS has become a routine, reliable protein separation and identification technology for proteome analysis. The demand for large-scale protein identifications after 2-DE separation requires a sensitive and high-throughput LC-MS/MS method. In this report, a simple, splitless, fully automated capillary LC-MS/MS system was described for the large-scale identification of proteins from gels stained with either silver or CBB. The gel samples were digested and peptides were extracted using an in-gel digestion workstation. The peptides were automatically introduced into a capillary column by an autosampler connected to an HPLC pump. A nanoLC pump was then used to deliver the gradient and elute the peptides from the capillary column directly into an LCQ IT mass spectrometer. Neither a peptide trapping setting nor a flow split is needed in this simple setup. The collected MS/MS spectra were then automatically searched by SEQUEST, and filtered and organized by DTASelect. Hundreds of silver-stained or CBB-stained Shewanella oneidensis, Geobacter sulfurreducens, and Geobacter metallireducens proteins separated by denaturing or nondenaturing 2-DE were digested and routinely analyzed using this fully automated muLC-MS/MS system. High peptide hits and sequence coverage were achieved for most CBB-stained gel spots. About 75% of the spots were found to contain multiple proteins. Although silver staining is not commonly thought to be optimal for MS analysis, protein identifications were successfully obtained from silver-stained 2-DE spots detected using methods with and without formaldehyde for protein fixation.  相似文献   

8.
Chen J  Lee CS  Shen Y  Smith RD  Baehrecke EH 《Electrophoresis》2002,23(18):3143-3148
On-line combination of capillary isoelectric focusing (CIEF) with capillary reversed-phase liquid chromatography (CRPLC) is developed using a microinjector as the interface for performing two-dimensional (2-D) protein/peptide separations of complex protein mixtures. The focusing effect of CIEF not only contributes to a high-resolution protein/peptide separation, but also may permit the analysis of low-abundance proteins with a typical concentration factor of 50-100 times. The preparative capabilities of CIEF are much larger than most of capillary-based electrokinetic separation techniques since the entire capillary is initially filled with a solution containing proteins/peptides and carrier ampholytes for the creation of a pH gradient inside the capillary. The focused peptides which have a similar pI are coinjected into the second separation dimension and further resolved by their differences in hydrophobicity. The resolving power of combined CIEF-CRPLC system is demonstrated using the soluble fraction of Drosophila salivary glands taken from a period beginning before steroid-triggered programmed cell death and extending to its completion. The separation mechanisms of CIEF and CRPLC are completely orthogonal and the overall peak capacity is estimated to be around approximately 1800 over a run time of less than 8 h. Significant enhancement in the separation peak capacity can be realized by further increasing the number of CIEF fractions and/or slowing the solvent gradient in CRPLC, however, at the expense of overall analysis time. The results of our preliminary studies display significant differences in the separation profiles of peptide samples obtained from salivary glands of animals staged at the 6 and 12 h following puparium formation.  相似文献   

9.
The use of two different monoliths located in capillaries for on-line protein digestion, preconcentration of peptides and their separation has been demonstrated. The first monolith was used as support for covalent immobilization of pepsin. This monolith with well-defined porous properties was prepared by in situ copolymerization of 2-vinyl-4,4-dimethylazlactone and ethylene dimethacrylate. The second, poly(lauryl methacrylate-co-ethylene dimethacrylate) monolith with a different porous structure served for the preconcentration of peptides from the digest and their separation in reversed-phase liquid chromatography mode. The top of the separation capillary was used as a preconcentrator, thus enabling the digestion of very dilute solutions of proteins in the bioreactor and increasing the sensitivity of the mass spectrometric detection of the peptides using a time-of-flight mass spectrometer with electrospray ionization. Myoglobin, albumin, and hemoglobin were digested to demonstrate feasibility of the concept of using the two monoliths in-line. Successive protein injections confirmed both the repeatability of the results and the ability to reuse the bioreactor for at least 20 digestions.  相似文献   

10.
Off-line digestion of proteins using immobilized trypsin beads is studied with respect to the format of the digestion reactor, the digestion conditions, the comparison with in-solution digestion and its use in complex biological samples. The use of the filter vial as the most appropriate digestion reactor enables simple, efficient and easy-to-handle off-line digestion of the proteins on trypsin beads. It was shown that complex proteins like bovine serum albumin (BSA) need much longer time (89 min) and elevated temperature (37 degrees C) to be digested to an acceptable level compared to smaller proteins like cytochrome c (5 min, room temperature). Comparing the BSA digestion using immobilized trypsin beads with conventional in-solution digestion (overnight at 37 degrees C), it was shown that comparable results were obtained with respect to sequence coverage (>90%) and amount of missed cleavages (in both cases around 20 peptides with 1 or 2 missed cleavages were detected). However, the digestion using immobilized trypsin beads was considerable less time consuming. Good reproducibility and signal intensities were obtained for the digestion products of BSA in a complex urine sample. In addition to this, peptide products of proteins typically present in urine were identified.  相似文献   

11.
An integrated platform consisting of protein separation by CIEF with monolithic immobilized pH gradient (M‐IPG), on‐line digestion by trypsin‐based immobilized enzyme microreactor (trypsin‐IMER), and peptide separation by CZE was established. In such a platform, a tee unit was used not only to connect M‐IPG CIEF column and trypsin‐IMER, but also to supply adjustment buffer to improve the compatibility of protein separation and digestion. Another interface was made by a Teflon tube with a nick to couple IMER and CZE via a short capillary, which was immerged in a centrifuge tube filled with 20 mmol/L glutamic acid, to exchange protein digests buffer and keep electric contact for peptide separation. By such a platform, under the optimal conditions, a mixture of ribonuclease A, myoglobin and BSA was separated into 12 fractions by M‐IPG CIEF, followed by on‐line digestion by trypsin‐IMER and peptide separation by CZE. Many peaks of tryptic peptides, corresponding to different proteins, were observed with high UV signals, indicating the excellent performance of such an integrated system. We hope that the CE‐based on‐line platform developed herein would provide another powerful alternative for an integrated analysis of proteins.  相似文献   

12.
利用毛细管作为酶固定化的载体,将酶直接键合到毛细管内壁,制成毛细管纳升反应器,结合质谱分析水解产物,获得了蛋白质的肽谱.实验发现,以毛细管为反应器后,蛋白质肽谱分析所需量大大减少,只需10-13mol,甚至几个10-15mol的量就可满足分析要求.  相似文献   

13.
A novel kind of hydrophilic monolith based immobilized enzyme reactors (IMERs) was prepared both in UV-transparent capillaries and on glass microchips by the photopolymerization of N-acryloxysuccinimide and poly(ethylene glycol)diacrylate, followed by trypsin immobilization. The performance of capillary IMERs for protein digestion was evaluated by the digestion of myoglobin with the residential time from 12s to 71 s. With μRPLC-ESI-MS/MS analysis, the obtained sequence coverages were all over 80%, comparable to that obtained by in-solution digestion for 12 h. The nonspecific absorption of BSA on monolithic support was evaluated, and no obvious protein residue was observed by a fluorescence assay. Moreover, no carry-over of the digests on the capillary IMER was found after the digestion of myoglobin (24 μg) and BSA (9 μg), which further demonstrated the good hydrophilicity of such matrix. In addition, an integrated microchip-based system involving on-line protein digestion by microchip-based IMER, peptides separation by nanoRPLC and identification by ESI-MS/MS was established, by which a mixture of standard proteins and one RPLC fraction of Escherichia coli extract were successfully identified, indicating that the hydrophilic monolith based IMER might provide a promising tool for high-throughput proteomic analysis.  相似文献   

14.
An on-Line multidimensional system has been developed, consisting of pH gradient strong anion exchange chromatography of native proteins in the first dimension with subsequent trapping and on-column reduction/alkylation on C4 trap columns and RP separation of the alkylated proteins in the second dimension followed by on-column tryptic digestion and electrospray MS detection. The system was evaluated using model proteins and a human urine sample. Compared to the commonly used in-solution alkylation method, the developed on-column method provides an equivalent efficiency. The recovery from the C4 trap columns of the alkylated proteins relative to the native state was from 94 to 102%. On-column tryptic digestion was satisfactory for many, but not for all proteins. The whole analytical procedure was performed on-Line with packed capillary columns for a total time of 320 min for the first ion exchange fraction, with additional 60 min for each subsequent fraction.  相似文献   

15.
A microfluidic device is described in which an electrospray interface to a mass spectrometer is integrated with a capillary electrophoresis channel, an injector and a protein digestion bed on a monolithic substrate. A large channel, 800 microm wide, 150 microm deep and 15 mm long, was created to act as a reactor bed for trypsin immobilized on 40-60 microm diameter beads. Separation was performed in channels etched 10 microm deep, 30 microm wide and about 45 mm long, feeding into a capillary, attached to the chip with a low dead volume coupling, that was 30 mm in length, with a 50 microm i.d. and 180 microm o.d. Sample was pumped through the reactor bed at flow rates between 0.5 and 60 microL/min. The application of this device for rapid digestion, separation and identification of proteins is demonstrated for melittin, cytochrome c and bovine serum albumin (BSA). The rate and efficiency of digestion was related to the flow rate of the substrate solution through the reactor bed. A flow rate of 1 or 0.5 microL/min was found adequate for complete consumption of cytochrome c or BSA, corresponding to a digestion time of 3-6 min at room temperature. Coverage of the amino acid sequence ranged from 92% for cytochrome c to 71% for BSA, with some missed cleavages observed. Melittin was consumed within 5 s. In contrast, a similar extent of digestion of melittin in a cuvet took 10-15 min. The kinetic limitations associated with the rapid digestion of low picomole levels of substrate were minimized using an integrated digestion bed with hydrodynamic flow to provide an increased ratio of trypsin to sample. This chip design thus provides a convenient platform for automated sample processing in proteomics applications.  相似文献   

16.
Mohan D  Lee CS 《Electrophoresis》2002,23(18):3160-3167
A microdialysis junction is employed as the interface for on-line coupling of capillary isoelectric focusing with transient isotachophoresis-zone electrophoresis in a two-dimensional separation system. Capillary isoelectric focusing not only provides high-resolution separation of tryptic peptides based on their differences in isoelectric point, but also potentially allows the analysis of low-abundance proteins with a typical concentration factor of 50-100 times. Carrier ampholytes, employed for the creation of a pH gradient during focusing, are further utilized as the leading electrolyte in the second separation dimension, transient isotachophoresis-zone electrophoresis. Many peptides which have the same isoelectric point would most likely have different charge-to-mass ratios, and thus different electrophoretic mobilities in zone electrophoresis. Two-dimensional separation of proteolytic peptides is demonstrated using standard proteins, including cytochrome c, ribonuclease A, and carbonic anhydrase II. The maximum peak capacity is estimated to be around approximately 1600 and can be significantly increased by simply increasing the capillary column length and manipulating the range of pH gradient in isoelectric focusing. In addition to enhanced separation efficiency and resolution, this two-dimensional electrokinetic separation system permits sensitive and comprehensive analysis of peptide fragments, especially when integrated with electrospray ionization mass spectrometry for peptide/protein identification.  相似文献   

17.
Two major milk whey proteins, β-lactoglobulin and α-lactalbumin, are among the main cow milk allergens and can cause allergy even at a very low concentrations. Therefore, these proteins are interesting targets in food analysis, not only for food quality control but also for highlighting the presence of allergens. Herein, a sensitive analysis for β-lactoglobulin and α-lactalbumin was developed using immunoaffinity capillary electrophoresis hyphenated with MALDI-MS. Magnetic beads functionalized with appropriate antibodies were used for β-lactoglobulin and α-lactalbumin immunocapture inside the capillary. After elution from the beads, analyte focusing and separation were performed by transient isotachophoresis followed by MALDI-MS analysis performed through an automated iontophoretic fraction collection interface. A LOD in the low nanomolar range was attained for both whey proteins. The method developed was further applied to the analysis of different milk samples including fortified soy milk.  相似文献   

18.
CE offers the advantage of flexibility and method development options. It excels in the area of separation of ions, chiral, polar and biological compounds (especially proteins and peptides). Masking the active sites on the inner surface of a bare fused silica capillary wall is often necessary for CE separations of basic compounds, proteins and peptides. The use of capillary surface coating is one of the approaches to prevent the adsorption phenomena and improve the repeatability of migration times and peak areas of these analytes. In this study, new capillary coatings consisting of (i) derivatized polystyrene nanoparticles and (ii) derivatized fullerenes were investigated for the analysis of peptides and protein digest by CE. The coated capillaries showed excellent run‐to‐run and batch‐to‐batch reproducibility (RSD of migration time ≤0.5% for run‐to‐run and ≤9.5% for batch‐to‐batch experiments). Furthermore, the capillaries offer high stability from pH 2.0 to 10.0. The actual potential of the coated capillaries was tested by combining CE with MALDI‐MS for analysing complex samples, such as peptides, whereas the overall performance of the CE‐MALDI‐MS system was investigated by analysing a five‐protein digest mixture. Subsequently, the peak list (peptide mass fingerprint) generated from the mass spectra of each fraction was entered into the Swiss‐Prot database in order to search for matching tryptic fragments using the MASCOT software. The sequence coverage of analysed proteins was between 36 and 68%. The established technology benefits from the synergism of high separation efficiency and the structure selective identification via MS.  相似文献   

19.
The research topics and the analytical strategies dealing with food proteins and peptides are summarized. Methods for the separation and purification of macromolecules of food concern by both high-performance liquid chromatography (HPLC) on conventional packings and perfusion HPLC are examined. Special attention is paid to novel methodologies such those based on multi-dimensional systems that comprise liquid-phase based protein separation, protein digestion and mass spectrometry (MS) analysis of food peptide and proteins. Recent applications of chromatography and MS-based techniques for the analysis of proteins and peptides in food are discussed.  相似文献   

20.
Weinberger SR  Viner RI  Ho P 《Electrophoresis》2002,23(18):3182-3192
A new global protein digestion and selective peptide extraction strategy for the purpose of monitoring differential protein expression, coined as tagless extraction-retentate chromatography, is introduced. Target protein populations are firstly digested under reduced and alkylated conditions, and resultant peptides selectively extracted via covalent attachment to methionine residues by bromoacetyl reactive groups tethered to the surface of glass beads packed in small reaction vessels. After conjugation, reactive beads are stringently washed to remove nonspecifically bound peptides and then later treated with beta-mercaptoethanol to release captured methionine peptides in their nascent state, without complicating affinity tags. Recovered methionine containing peptides are profiled using the surface-enhanced laser desorption/ionization (SELDI) retentate chromatography mass spectrometry (RCMS) method. Selected peptides are further studied employing ProteinChip tandem mass spectrometry (MS/MS) analysis to identify their parent proteins. This approach has been applied to an Escherichia coli lysate model system and has demonstrated facility in reducing global digest complexity, sensitivity to low protein expression levels, and significant quantitative capability. It is envisioned that tagless extraction-RCMS will evolve to be a valuable approach for both basic research and clinical proteomics endeavors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号