首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A redox reaction of cysteine with iron(III) proceeds slowly in the presence of 1,10-phenanthroline (phen). However, this reaction is accelerated in the presence of copper(II) as a catalyst, producing an iron(II)-phen complex (lambda(max)=510 nm). A sensitive spectrophotometric flow-injection method is proposed for the determination of copper(II) based on its catalytic action on this redox reaction. The dynamic range was 0.1-10 ng ml(-1) of copper(II) with a relative standard deviation of 1.0% (n=10) for 1.0 ng ml(-1) of copper(II) at a sampling rate of 30 h(-1). The detection limit (S/N=3) is 0.04 ng ml(-1). The proposed method was successfully applied to the determination of copper in river water as a certified reference material.  相似文献   

2.
Lin J  Hobo T 《Talanta》1995,42(11):1619-1623
A novel chemiluminescent system, fluorescein-NH(2)OHOH(-), was developed for the determination of copper(II) in serum. A weak light emission arises from hydroxylamine in the presence of the organic reagent fluorescein in basic aqueous solution. Under the conditions of 1.2 x 10(-3) mol l(-1) NH(2)OH and 5 x 10(-3) mol l(-3) fluorescein, the light intensity is linearly dependent upon the concentration of copper(II) within the range 1-20 ppb. The relative standard deviation of the determination of copper(II) is 4.2% (n = 13) and the detection limit is 0.5 ppb. The system is highly selective for copper except in the presence of iron(II,III) and cobalt(II). In conjunction with potassium fluoride as masking agent, the method was successfully applied to the determination of microamounts of copper(II) in serum. A mechanistic study of the chemiluminescence reaction is also discussed.  相似文献   

3.
A flow injection-catalytic spectrophotometric method using a serial flow cell was proposed for the successive determination of trace amounts of copper and iron. This method is based on the oxidation coupling of p-anisidine with N,N-dimethylaniline in the presence of hydrogen peroxide to form a dye, which has an absorption maximum at 740 nm. In this indicator reaction, ligands such as 1,10-phenanthroline (phen) and diphosphate were achieved to improve the sensitivity and selectivity. Under the optimal experimental conditions, the determinable ranges were 0.05-5 ppb for copper and 0.5 - 100 ppb for iron, respectively. The RSDs (n = 10) were 0.78% for 0.5 ppb copper(II) and 0.5% for 200 ppb iron(III). The sample throughput was 30 h(-1). The present flow-injection method was applied to the determination of copper and iron in standard river water, tap water, and other natural water samples, and also to the analysis of labile and inert complexes in synthesized samples containing humic acid with copper(II) or iron(III).  相似文献   

4.
A novel chemiluminescence (CL) reaction, thiosemicarbazide (TSC)–H2O2, for the determination of copper at nanogram per milliliter level in batch type is described. The method is based on the catalytic effect of copper(II) on the oxidation of TSC with hydrogen peroxide to produce light emission. The emitted light was observed by using a conventional fluorescence detector. In the optimum conditions, calibration graph was linear in the range of 0.1–1.3 ppm. The limit of detection was 10 ppb. The relative standard deviation for five determinations of 0.5 ppm copper(II) was 1.93%. The proposed method permitted the selective and sensitive determination of Cu(II) in human hair and wheat flour with sufficient precision. The possible mechanism for the new chemiluminescence reaction was also discussed.  相似文献   

5.
The possibility of application was examined of a reaction between 2,2′-diquinoxalyl and tin(II) or titanium(III) to catalytic determination of copper and iron. The reaction parameters, the influence of the hydrogen peroxide concentration, the hydrochloric acid concentration, and the presence of strange ions on oxidation of the reduced form of 2,2′-diquinoxalyl were tested.The usefulness of the established method was proven for the determination of copper(II) and iron(III) ions in the spectrally pure salts, having the concentration range of those ions 10?4-10?5%. The sensitivity of the discussed method is of 0.04 μg/ml.  相似文献   

6.
Ohno S  Teshima N  Zhang H  Sakai T 《Talanta》2003,60(6):1177-1185
A kinetic–catalytic spectrophotometric method is proposed for the successive determination of nanogram levels of copper and iron, which is based on their catalytic effects on the oxidative coupling of p-anisidine with N,N-dimethylaniline (DMA) to form a colored compound (λmax=740 nm) in the presence of hydrogen peroxide at pH 3.2. 2,9-Dimethyl-1,10-phenanthroline (neocuproine) acted as an activator for the copper catalysis, and 1,10-phenanthroline (phen) acted as an activator for the iron catalysis. The selectivity was improved in the presence of diphosphate as a masking agent. The determinable ranges were 0.16–10 ppb for copper and 1–100 ppb for iron, respectively. The relative standard deviations of copper and iron were 1.1 and 0.97% for five determinations of 10 ppb copper and 40 ppb iron. The method was successfully applied to the analyses of copper and iron in tap, well, river and pond waters.  相似文献   

7.
A new catalytic method for the determination of silver(I) was developed based on a metal exchange reaction between ethylenediaminetetraacetatomercury(II) (Hg(II)-EDTA) in the aqueous phase and bis(diethyldithiocarbamato)copper(II) (Cu(II)-DDTC) in the organic phase. This exchange reaction (Cu(II)-DDTC(org)+Hg(II)-EDTA-->Hg(II)-DDTC(org)+Cu(II)-EDTA, where org denotes the organic phase) was observed to proceed slowly and the Cu(II)-DDTC complex transferred quantitatively to Hg(II)-complex in the organic phase in the equilibrium state. In this system, silver(I) acts as the catalyst and can be determined by measuring the decrease in the absorbance of the Cu(II)-DDTC complex (lambda(max)=435 nm). The reaction was applied to the extractive flow injection analysis of silver(I). The present method allows the determination of silver(I) at 10(-7) mol dm(-3) level with the sampling frequency of 30 h(-1). The relative standard deviation of 0.28% (n=10) was obtained at 4.0x10(-7) mol dm(-3) of silver(I).  相似文献   

8.
A catalytic spectrophotometric method for the determination of traces of copper(II) is proposed. 3-Methyl-2-benzothiazolinone hydrazone (MBTH) is oxidized by hydrogen peroxide to form a yellowish-brown compound. The reaction is accelerated by trace amounts of copper(II), and can be followed by measuring the increase in the absorbance at 390 nm. Since the absorbance at 40 min from the reaction start increases with an increase in the copper(II) concentration, the absorbance value is used as a parameter for copper(II) determination. Under the optimum experimental conditions (8.4 x 10(-3) mol dm(-3) MBTH, 0.7 mol dm(-3) hydrogen peroxide, pH 5.2, 35 degrees C), copper(II) can be determined in the range 0-50 microg dm(-3). The relative standard deviations are 6.9, 3.5, 2.7% for 2, 20 and 40 microg dm(-3), respectively. The detection limit of this method (3sigma) is 0.27 microg dm(-3). It was successfully applied to a determination of copper(II) in river water, tap water and ground-water samples. According to the results of a kinetic study, a mechanism is proposed which leads to the following rate equation: R0(cat) = kK1K2[MBTH][H2O2][Cu(II)]0/{(1 + K2[H2O2])[H+]}.  相似文献   

9.
A flow injection procedure for the sequential spectrophotometric determination of iron(II) and iron(III) in pharmaceutical products is described. The method is based on the catalytic effect of iron(II) on the oxidation of iodide by bromate at pH = 4.0. The reaction was monitored spectrophotometrically by measuring the absorbance of produced triiodide ion at 352 nm. The activating effect for the catalysis of iron(II) was extremely exhibited in the presence of oxalate ions, while oxalate acted as a masking agent for iron(III). The iron(III) in a sample solution could be determined by passing through a Cd-Hg reductor column introduced in the FIA system to reduce iron(III) to iron(II), which allows total iron determination. Under the optimum conditions, iron(II) and iron(III) could be determined over the range of 0.05 - 5.0 and 0.10 - 5.0 microg ml(-1), respectively with a sampling rate of 17 +/- 5 h(-1). The experimental limits of detection were 0.03 and 0.04 microg ml(-1) for iron(II) and iron(III), respectively. The proposed method was successfully applied to the speciation of iron in pharmaceutical products.  相似文献   

10.
Tarek M  Zaki M  Mahmoud WH  El-Sayed AY 《Talanta》1988,35(4):253-257
A method for iron(II) determination based on reaction with Pyrocatechol Violet to form a 1:2 binary complex at pH 5-7 is described and has been extended to an extraction-spectrophotometric procedure for the determination of iron(II) by formation of the 1:2:2 iron(II)-Pyrocatechol Violet-cetyltrimethylammonium bromide ternary complex. The molar absorptivities of the binary and ternary complexes at 595 and 605 nm are 6.55 x 10(4) and 1.35 x 10(5)1.mole(-1).cm(-1), respectively. The method has been successfully applied to the determination of iron in felspar, Portland cement and sodium hydroxide.  相似文献   

11.
Mudasir  Yoshioka N  Inoue H 《Talanta》1997,44(7):1195-1202
A reversed phase ion-paired chromatographic method that can be used to determine trace amounts of iron (II,III), nickel (II) and copper (II) was developed and applied to the determination of iron (II) and iron (III) levels in natural water. The separation of these metal ions as their 4,7-diphenyl-1,10-phenanthroline (bathophenanthroline) chelates on an Inertsil ODS column was investigated by using acetonitrile-water (80/20, v/v) containing 0.06 M perchloric acid as mobile phase and diode array spectrophotometric detection at 250-650 nm. Chromatographic parameters such as composition of mobile phase and concentration of perchloric acid in mobile phase were optimized. The calibration graphs of iron (II), nickel (II) and copper (II) ions were linear (r > 0.991) in the concentration range 0-0.5, 0-2.0 and 0-4.0 mug ml(-1), respectively. The detection limit of iron (II), nickel (II) and copper (II) were 2.67, 5.42 and 18.2 ng ml(-1) with relative standard deviation (n = 5) of 3.11, 5.81 and 7.16% at a concentration level of 10 ng ml(-1) for iron (II) and nickel (II) and 25 ng ml(-1) for copper (II), respectively. The proposed method was applied to the determination of iron(II) and iron(III) in tap water and sea water samples without any interference from other common metal ions.  相似文献   

12.
A spectrophotometric method is developed for the determination of traces of copper(II), based on the catalytic oxidative coupling reaction of 3-hydroxyacetanilide with 3-methyl-2-benzothiazolinone hydrazone in the presence of ammonia and hydrochloric acid. Beer's law is obeyed in the copper(II) concentration range of 0.008-0.16 microg mL(-1), and the molar absorptivity at 530 nm is 2.5x10(5) L mol(-1) cm(-1). The Sandell's sensitivity of the product is 0.000254 microg cm(-2). The optimum reaction conditions and other important analytical parameters have been investigated. The proposed method is applied to the analysis of water and soil samples and the results are compared with the literature method.  相似文献   

13.
Rao BV  Gopinath R 《Talanta》1989,36(8):867-868
A simple potentiometric method is presented for successive determination of iron(III) and cobalt(II) by complexometric titration of the iron(III) with EDTA at pH 2 and 40 degrees , followed by redox titration of the cobalt(II) complex with 1,10-phenanthroline or 2,2'-bipyridyl at pH 4-5 and 40 degrees , with gold(III). There is no interference in either determination from common metal ions other than copper(II), which severely affects the cobalt determination but can be removed by electrolysis. The method has been successfully applied to determination of iron and cobalt in Kovar and Alnico magnet alloys.  相似文献   

14.
Khuhawar MY  Lanjwani SN 《Talanta》1998,46(4):485-490
The complexing reagent 2-thiophenaldehyde-4-phenyl-3-thiosemicarbazone (TAPT) was examined for high performance liquid chromatographic (HPLC) separations of cobalt(II), copper(II) and iron(II) or cobalt(II), nickel(II), iron(II), copper(II) and mercury(II) as metal chelates on a Microsorb C-18, 5-mum column (150x4.6 mm i.d.) (Rainin Instruments Woburn, MA, USA). The complexes were eluted isocratically with methanol:acetonitrile:water containing sodium acetate and tetrabutyl ammonium bromide (TBA). UV detection was at 254 nm. The solvent extraction procedure was developed for simultaneous determination of the metals, with detection limits within 0.5-2.5 mug ml(-1) in the final solution. The method was applied for the determination of copper, cobalt and iron in pharmaceutical preparation.  相似文献   

15.
Copper(II) ions catalyze the iron(III)—thiosulfate indicator reaction. This chemical system has been successfully used in a closed-loop apparatus with unsegmented continuous flow for the determination of copper in human blood serum. The sought-for species (the catalyst) is removed from the recirculating reagent by controlled-potential electrolysis after detection has taken place. Such electrolysis is also employed for in situ regeneration of the main reagent, iron(III). The reported method (a fixed-time, variable-signal kinetic determination) has a limit of detection for copper(II) of 0.25 μg ml-1 and permits 325 determinations per hour with a relative standard deviation of 2%.  相似文献   

16.
Thakur M  Deb MK 《Talanta》1999,49(3):561-569
A simple and sensitive field detection and spectrophotometric method for determination of copper described herewith is based on the formation of a red coloured species of copper(II) with 1-[pyridyl-(2)-azo]-naphthol-(2) (PAN), TX-100 and N,N'-diphenylbenzamidine (DPBA) at pH range 7.8-9.4. The red coloured Cu(II)-PAN-(TX-100)-DPBA complex in chloroform shows maximum absorbance at 520 nm with molar absorptivity value of 1.14x10(5) l mol(-1) cm(-1). The detection limit of the method is 2 ng ml(-1) organic phase. The system obeys Beer's law up to 0.6 mug Cu(II) ml(-1) in organic solution. Most of the common metal ions generally found associated with copper do not interfere. The repeatability of the method was checked by finding relative standard deviation (RSD) (n=10) value for solutions each containing 0.2 mug ml(-1) of Cu(II) and the RSD value of the method was found to be 1.5%. The validity of the method has been satisfactorily examined for the determination of copper in soil and airborne dust particulate samples.  相似文献   

17.
《Analytical letters》2012,45(7):1219-1230
Abstract

An indirect photometric method with a continuous-flow analysis is presented for the determination of trace amounts of vanadium(IV). It is based on the redox reaction of copper(II) with vanadium(1V) in the presence of neocuproine. In the presence of neocuproine, copper(I1) is reduced easily by vanadium(I V) to a copper(1)-neocuproine complex, which shows a n absorption maximum at 454 nm. By measuring t h e absorbance of the complex at this wavelength, vanadium(1V) in t h e range 2×10?6 - 8 × mol dm?5 mol dm?3 can be determined at a rate of 120 samples h?1. The fractional determination of vanadium(1V) and iron(I1) is also studied.  相似文献   

18.
童沈阳  孙国斌 《化学学报》1988,46(8):812-815
研究了以meso-四(N-甲基-3-吡啶基)卟啉测定锌痕量锌的荧光光度法, 其灵敏度较其它水溶性卟啉衍生物测定锌的分光光度法要高, 检出量为1ppb, 线性范围为0-1.0μg/25mL. 方法已用于测定自来水和头发中的微量锌, 结果满意.  相似文献   

19.
Gao HW 《Talanta》2000,52(5):817-823
The report was the first to establish the new method for the selective determination of trace amounts of metal using the substitution reaction in metallic complex. The reactions between copper(II) and 1-(5-bromo-2-pyridylazo)-2-naphthol-6-sulphonic acid (BPANS) and between ferrous(II) and BPANS at pH 3.5 were studied. In absence of any masking reagent, the recommended method was selective in the determination of trace amounts of copper with Fe-BPANS complex as chromogenic reagent because copper(II) can substitute Fe from Fe-BPANS complex to form Cu-BPANS complex. The ordinary spectrophotometric method was unsuitable to the substitution reaction because the excess of Fe-BPANS complex had the high absorption and affected seriously the absorption of Cu-BPTANS complex. The spectral correction principle may eliminate the above influence to give the simple determination of the composition ratio, stepwise absorptivity (epsilon) and stability constant (K) of metal complex. For analysis of samples, the recovery of copper was between 96.5 and 106% with R.S.D. less than 5%.  相似文献   

20.
An optimized flow-injection manifold for the chemiluminescence determination of cobalt(II), copper(II), iron(II) and chromium(III) by their catalytic effect on the luminol reaction is described. Detection limits are 0.0006, 0.08, 0.3 and 0.1 ng ml?1, respectively. The suppression effect of several carboxylic acids on the emission intensity is discussed. A procedure for the separation of cobalt(II), copper(II) and iron(II) on a low-capacity, silica-based cation-exchange column, using 5 mM oxalic acid at pH 4.2 as the mobile phase and post-column detection via the luminol reaction, is also described. Detection limits for cobalt(II) and copper(II) are 0.01 and 5 ng ml?1, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏