首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
The signal-to-noise ratio (SNR) performance and practicality issues of a four-element phased-array coil and an implantable coil system were compared for rat spinal cord magnetic resonance imaging (MRI) at 7 T. MRI scans of the rat spinal cord at T10 were acquired from eight rats over a 3 week period using both coil systems, with and without laminectomy. The results demonstrate that both the phased array and the implantable coil systems are feasible options for rat spinal cord imaging at 7 T, with both systems providing adequate SNR for 100-mum spatial resolution at reasonable imaging times. The implantable coils provided significantly higher SNR, as compared to the phased array (average SNR gain of 5.3x between the laminectomy groups and 2.5x between the nonlaminectomy groups). The implantable coil system should be used if maximal SNR is critical, whereas the phased array is a good choice for its ease of use and lesser invasiveness.  相似文献   

2.
MR Imaging the spinal cord of non-human primates (NHP), such as squirrel monkey, is important since the injuries in NHP resemble those that afflict human spinal cords. Our previous studies have reported a multi-parametric MRI protocol, including functional MRI, diffusion tensor imaging, quantitative magnetization transfer and chemical exchange saturation transfer, which allows non-invasive detection and monitoring of injury-associated structural, functional and molecular changes over time. High signal-to-noise ratio (SNR) is critical for obtaining high-resolution images and robust estimates of MRI parameters. In this work, we describe our construction and use of a single channel coil designed to maximize the SNR for imaging the squirrel monkey cervical spinal cord in a 21 cm bore magnet at 9.4 T. We first numerically optimized the coil dimension of a single loop coil and then evaluated the benefits of a quadrature design. We then built an optimized coil based on the simulation results and compared its SNR performance with a non-optimized single coil in both phantoms and in vivo.  相似文献   

3.
In vivo echo-planar imaging of rat spinal cord   总被引:1,自引:0,他引:1  
An integrated approach to echo-planar imaging of rat spinal cord in vivo with a small field of view (FOV) is presented. This protocol is based on a multishot interleaved echo-planar imaging (EPI) sequence and includes: 1) use of an inductively coupled implantable coil for improved signal-to-noise ratio (SNR); 2) three-dimensional (3D) automatic shimming of the magnetic field over the spinal cord; and 3) post-acquisition data processing using a multireference scan for minimizing image artifacts. Some of the practical issues in implementing this protocol are discussed. This imaging protocol will be useful in characterizing the spinal cord pathology using techniques that are otherwise time-consuming, such as diffusion tensor imaging.  相似文献   

4.
A sensitive magnetic resonance imaging (MRI) method to measure spinal cord cross-sectional area with the potential to monitor disease progression has recently been developed. As changes in cord area due to disease are usually small, assessment of the reliability of the methodology is essential in serial studies of spinal cord atrophy. The aim of this study was to institute and evaluate a protocol of quality assurance to determine long-term reproducibility of serial studies. Serial MRI of the spinal cord was carried out in five healthy volunteer controls over 1 year. Cross-sectional spinal cord areas were measured in a total of 46 scans. The mean coefficient of variation of all subjects over one year was 1.35%. The intra-observer coefficient of variation for same scan analysis was 0.63%. This study has confirmed high reliability of our serial data over one year and the on-going quality assurance protocol enables continuing evaluation of the reproducibility of results in serial studies. Quality assurance is an essential and practical component of all serial MRI studies, without which the clinical implications of change cannot be reliably evaluated.  相似文献   

5.
Quantitative magnetic resonance imaging (MRI) studies of small samples such as a single cell or cell clusters require application of radiofrequency (RF) coils that provide homogenous B1 field distribution and high signal-to-noise ratio (SNR).We present a novel design of an MRI RF volume microcoil based on a microstrip structure. The coil consists of two parallel microstrip elements conducting RF currents in the opposite directions, thus creating homogenous RF field within the space between the microstrips. The construction of the microcoil is simple, efficient and cost-effective.Theoretical calculations and finite element method simulations were used to optimize the coil geometry to achieve optimal B1 and SNR distributions within the sample and predict parameters of the coil. The theoretical calculations were confirmed with MR images of a 1-mm-diameter capillary and a plant obtained with the double microstrip RF microcoil at 11.7 T. The in-plane resolution of MR images was 24 μm×24 μm.  相似文献   

6.
A Helmholtz-pair local transmit RF coil with an integrated four-element receive array RF coil and foot immobilization platform was designed and constructed for imaging the distal tibia in a whole-body 7T MRI scanner. Simulations and measurements of the B(1) field distribution of the transmit coil are described, along with SAR considerations for operation at 7T. Results of imaging the trabecular bone of three volunteers at 1.5T, 3T and 7T are presented, using identical 1.5T and 3T versions of the 7T four-element receive array. The spatially registered images reveal improved visibility for individual trabeculae and show average gains in SNR of 2.8× and 4.9× for imaging at 7T compared to 3T and 1.5T, respectively. The results thus display an approximately linear dependence of SNR with field strength and enable the practical utility of 7T scanners for micro-MRI of trabecular bone.  相似文献   

7.
孟斌  黄开文  王为民 《中国物理 B》2010,19(7):76103-076103
In this article,a novel designed radio frequency (RF) coil is designed and built for the imaging of puppies in a V-shape permanent magnetic resonance imaging (MRI) system.Two sets of Helmholtz coil pairs with a V-shape structure are used to improve the holding of an animal in the coil.The homogeneity and the sensitivity of the RF field in the coil are analysed by theoretical calculation.The size and the shape of the new coil are optimized and validated by simulation through using the finite element method (FEM).Good magnetic resonance (MR) images are achieved on a shepherd dog.  相似文献   

8.
Proper design of a birdcage coil plays a very important role in obtaining high-resolution small animal magnetic resonance imaging. The RF field homogeneity and the coil filling factor directly affect the signal-to-noise ratio (S/N) and therefore limit the resolution. It has been shown that a conductive end-cap placed on one side of the coil can improve the RF field inhomogeneity near this area. This also contributes to an increase in the S/N by reducing the length of the RF coil. While this is true near the end-cap, the distal half of the coil still suffers from poor homogeneity and S/N. Consequently, such a shortfall may hinder small animal whole body imaging. In order to improve the coil performance for a larger imaging volume, we designed a new small animal birdcage RF coil by adding a detachable second end-cap to the open end. The performance of single end and double end RF coils was compared experimentally. The results indicate that the double end-cap can provide superior uniformity along the long axis of the coil. Furthermore, if one wishes to obtain the same homogeneity within a given volume, a double end-cap would have less than half of the length of the single end-cap coil leading to a superior S/N performance.  相似文献   

9.
A quadrature transmit/receive birdcage coil was optimized for squirrel monkey functional imaging at the high field of 9.4 T. The coil length was chosen to gain maximum coil efficiency/signal-to-noise ratio (SNR) and meanwhile provide enough homogenous RF field in the whole brain area. Based on the numerical simulation results, a 16-rung high-pass birdcage coil with the optimal length of 9 cm was constructed and evaluated on phantom and in vivo experiments. Compared to a general-purpose non-optimized coil, it exhibits approximately 25% in vivo SNR improvement. In addition to the volume coil, details about how to design and construct the associated animal preparation system were provided.  相似文献   

10.

Background and Purpose

Susceptibility weighted imaging (SWI) is sensitive to deoxyhemoglobin and blood products such as hemosiderin in detecting microbleeds in the brain. However, there are no studies on SWI in the spine cord injury so far. The purpose of this study was to evaluate the role of SWI in detecting hemorrhage in acute cervical spinal cord injury (SCI).

Materials and Methods

Twenty-three patients with a history of acute cervical spine trauma were studied. High-resolution SWI, gradient-echo (GRE) T2* weighted-image (T2*WI) and conventional magnetic resonance imaging (MRI) were performed on all patients within 15 days of the onset of injury. On the basis of the MRI findings, the patients were classified into four patterns: normal cord, spinal cord edema, spinal cord contusion and spinal cord hemorrhage. Quantitative analysis was performed by calculating and comparing the signal ratio of the hemorrhage to normal spinal cord on the same slice of T2*WI and SWI. All patients were clinically evaluated in follow-up. Twenty volunteers were also scanned as a control group.

Results

Out of 23 patients with a history of acute cervical spine trauma, 4 patients showed normal spinal cord on both conventional MRI and SWI, 8 had only spinal cord edema and 5 had contusion on conventional MRI, but SWI showed hemorrhage in 2 of the 5 patients with spinal contusion on conventional MRI; the other 6 patients had intraspinal hemorrhage on conventional MRI, and SWI proved hemorrhage in all these 6 patients. There was a significant difference between the signal ratios of hemorrhage to normal tissue on T2*WI and SWI (Z=2.34, P=.02).

Conclusion

Susceptibility weighted imaging is more sensitive than conventional MRI in detecting hemorrhage in acute cervical SCI. This technique could prove to be a useful tool in the routine evaluation of cervical SCI patients.  相似文献   

11.
Magnetic resonance imaging (MRI) technique is widely used to capture the images of the liquid items inside the human body. The radio-frequency (RF) coil is one of the important modules present inside an MRI system, which plays a major role in image quality. In this work, a microstrip-based high-pass RF birdcage coil is proposed for 1.5 T MRI. The cylindrical-shaped birdcage coil consists of 12 microstrip radiating elements and tuning capacitors to achieve a resonance at 63.85 MHz. The coil is made up of 10 mm polytetrafluoroethylene substrate coated by a conducting transmission line of desired length and width. A finite difference time domain simulation is carried out to analyze the return loss (S11), magnetic field homogeneity and Specific Absorption Rate (SAR) parameters of the RF coil. The SAR values of the proposed microstrip-based 1.5 T birdcage coil was compared with 3 T RF birdcage coil. The simulation results indicate the proposed birdcage coil structure gives optimal values of S11, magnetic field homogeneity and SAR.  相似文献   

12.
A direct modulated optical link for MRI RF receive coil interconnection   总被引:1,自引:1,他引:0  
Optical glass fiber is a promising alternative to traditional coaxial cables for MRI RF receive coil interconnection to avoid any crosstalk and electromagnetic interference between multiple channels. A direct modulated optical link is proposed for MRI coil interconnection in this paper. The link performances of power gain, frequency response and dynamic range are measured. Phantom and in vivo human head images have been demonstrated by the connection of this direct modulated optical link to a head coil on a 0.3T MRI scanner for the first time. Comparable image qualities to coaxial cable link verify the feasibility of using the optical link for imaging with minor modification on the existing scanners. This optical link could also be easily extended for multi-channel array interconnections at high field of 1.5 T.  相似文献   

13.
Magnetic resonance imaging (MRI) has been performed to assess the efficacy of hyperbaric oxygen (HBO) treatment on experimental spinal cord injury in a rat animal model. A moderately severe injury, similar to Type III injury seen in humans (Kulkarni et al. Radiology 164:837;1987) has been chosen for these studies. An improvement in the neurologic recovery (based on Tarlov scale) has been observed following HBO treatment over a period of 72 hr. Based on MRI, HBO treatment appears to arrest the spread of hemorrhage and resolve edema.  相似文献   

14.
在临床用MRI系统上对小动物扩散加权成像一般采用回波平面成像序列,但是回波平面成像易受偏共振效应的影响,得到的图像伪影大、几何变形严重、图像分辨率低,无法探究微小的生物组织结构. 该文报道了在临床用3 T MRI系统上采用自旋回波序列实现了高分辨扩散加权成像. 为减少运动伪影,序列中整合了导航回波矫正技术. 对脑缺血模型大鼠脑部的扫描结果显示,自旋回波扩散加权序列获得的图像基本没有发生形变,并且具有较高的分辨率和较好的信噪比.  相似文献   

15.
介绍了用于23Na磁共振成像实验的收发一体表面线圈的设计、制作原理与实际制作. 用制作的23Na表面线圈在Bruker Biospec 47/30磁共振成像仪上采集了不同浓度NaCl溶液,盐腌制鹌鹑蛋和大鼠头部的23Na密度像,为深入开展23Na磁共振成像的生物医学应用研究奠定基础.  相似文献   

16.
In clinical magnetic resonance imaging(MRI),the design of the radiofrequency(RF) coil is very important.For certain applications,the appropriate coil can produce an improved image quality.However,it is difficult to achieve a uniform B1 field and a high signal-to-noise ratio(SNR) simultaneously.In this article,we design an interventional transmitter-and-receiver RF coil for cerebral surgery.This coil adopts a disassembly structure that can be assembled and disassembled repeatedly on the cerebral surgery gantry to reduce the amount of interference from the MRI during surgery.The simulation results and the imaging experiments demonstrate that this coil can produce a uniform RF field,a high SNR,and a large imaging range to meet the requirements of the cerebral surgery.  相似文献   

17.
Sixteen magnetic resonance (MR) studies were performed in eight patients with mucopolysaccharidosis (MPS). In patients with Hunter, Hurler, and Scheie syndromes, multiple areas of increased signal intensity were noted in the periventricular white matter. Computerized tomography (CT) frequently failed to demonstrate these white matter lesions. Other findings included spinal cord compression, hydrocephalus and airway obstruction due to soft tissue thickening around pharynx. In patients with Morquio syndrome, cervical spine dislocation, spinal cord compression and hydrocephalus were diagnosed by MR. MR was superior compared to CT, plain films and plain tomography, as the narrowing caused by bone and soft tissue changes were better seen with MR. Our experience suggests that MR should be the primary imaging modality for the detection of cranial abnormalities in patients with MPS. High resolution surface coil imaging may be preferable to invasive procedures such as myelography and CT with intrathecal contrast agents for the evaluation of cervical spine disease.  相似文献   

18.
在临床磁共振成像(MRI)应用中,射频线圈的设计是非常关键的,针对不同的应用目的,合适的线圈能获得质量更好的图像. 有的应用需要线圈提供均匀性较好的射频场,而有的应用则需要线圈在特定区域内提供高的信噪比(SNR). 但是线圈很难同时得到好的射频场(B1场)、空间均匀性和高的SNR,需要根据实际应用情况进行折衷设计. 针对MRI在脑外科手术中的应用特点,设计并制作了一种新颖的、适用于脑外科手术的MRI接收和发射共用射频线圈. 该线圈采用可分拆式结构,在脑外科手术支架上可以进行反复组装和拆卸,减少了MRI对医生手术的影响. 仿真结果和人体成像实验表明,该线圈能产生均匀的射频场、有较高的SNR和较大的成像范围,满足脑外科手术的需要.  相似文献   

19.
Measuring eye movements (EMs) using the search-coil eye-tracking technique is superior to video-based infrared methods [Collewijn H, van der Mark F, Jansen TC. Precise recording of human eye movements. Vision Res 1975;15(3):447-50], which suffer from the instability of pupil size, blinking behavior and lower temporal resolution. However, no conventional functional magnetic resonance imaging (fMRI)-compatible search-coil eye tracker exists. The main problems for such a technique are the interaction between the transmitter coils and the magnetic gradients used for imaging as well as the limited amount of space in a scanner. Here we present an approach to overcome these problems and we demonstrate a method to record EMs in an MRI scanner using a search coil. The system described has a spatial resolution of 0.07 degrees (visual angle) and a high temporal resolution (22 kHz). The transmitter coils are integrated into the visual presentation system and the control/analysis unit is portable, which enables us to integrate the eye tracker with an MRI scanner. Our tests demonstrate low noise in the recorded eye traces and scanning with minimal artifact. Furthermore, the induced current in the search coil caused by the RF pulses does not lead to measurable heating. Altogether, this MR-compatible search-coil eye tracker can be used to precisely monitor EMs with high spatial and temporal resolution during fMRI. It can therefore be of great importance for studies requiring accurate fixation of a target, or measurement and study of the subject's oculomotor system.  相似文献   

20.
Study of human pathologies and acquisition of anatomical images without any surgical intervention inside human body is possible because of magnetic resonance imaging (MRI), which is the keystone technique to characterize the psychology and neurochemistry of human body. However, for clinical trials, the study and cure of human diseases are followed by medical investigations of different animal anatomies. By employing different imaging techniques to animal anatomical models during their clinical trials yielded in exceptional image acquisition without any surgical invasion in the model, which resulted in noninvasive technique as compared to surgical invasion and opened the possibility to study human pathologies more precisely. This work exploits the notable properties of unique combination of multi-circular hybridized surface coils which can be used as hybridized magnetic metamaterial hat (HMMH). HMMH not only strengthens the uniformity of radio frequency (RF) rotational symmetry around its axis but also improves the signal-to-noise ratio (SNR) for rat’s brain imaging at 7-T MRI. We analyzed a periodic array of strongly coupled circular copper coils attached on circular coil shaped printed circuit board (PCB) substrate. In the design, some copper coils were inspired by the slot cavity loaded with parametric elements (capacitor and inductor). In addition, coils in the form of HMMH exploited the advantages of the hybrid modes which exhibited better and deeper RF sensitivity into the region of interest (ROI) as compared to single loop RF coil by exciting two Eigen modes simultaneously which resulted in homogenized magnetic field (B-field) and enhanced SNR at ROI. At resonance, the value of relative negative permeability, μ r  = ?7 + j11 was achieved at 300 MHz for 7-T MRI. Furthermore, image quality at ROI was optimized by varying rat’s head position under magnetic resonance (MR) coil of MRI apparatus and in the presence or absence of HMMH. Design configuration and circuit model analysis were also done.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号