首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A collaborative study was conducted to determine multiple pesticide residues in fruits and vegetables using a quick, simple, inexpensive, and effective sample preparation method followed by concurrent analysis with gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/ tandem mass spectrometry (LC/MS/MS). For short, the method is known as QuEChERS, which stands for quick, easy, cheap, effective, rugged, and safe. Twenty representative pesticides were fortified in 3 matrixes (grapes, lettuces, and oranges) at 3 duplicate levels unknown to the collaborators ranging from 10 to 1000 ng/g. Additionally, 8 incurred pesticide residues were determined. Thirteen laboratories from 7 countries provided results in the study, and a variety of different instruments were used by collaborators. The QuEChERS procedure simply entails 3 main steps: (1) a 15 g homogenized sample is weighed into a 50 mL centrifuge tube to which 15 mL acetonitrile containing 1% HOAc is added along with 6 g MgSO4 and 1.5 g NaOAc, and the tube is shaken and centrifuged; (2) a portion of the extract is mixed with 3 + 1 (w/w) MgSO4-primary secondary amine sorbent (200 mg/mL extract) and centrifuged; and (3) the final extract is analyzed by GC/MS and LC/MS/MS. To detect residues <10 ng/g in GC/MS, large-volume injection of 8 microL is typically needed, or the extract can be concentrated to 4 g/mL in toluene, in which case 2 microL splitless injection is used. In the study, the averaged results for data from 7-13 laboratories (not using internal standardization) for the 18 blind duplicates at the 9 spiking levels in the 3 matrixes are as follows [%recovery and reproducibility relative standard deviation (RSD(R), %)]: atrazine, 92 (18); azoxystrobin, 93 (15); bifenthrin, 90 (16); carbaryl, 96 (20); chlorothalonil, 70 (34); chlorpyrifos, 89 (25); cyprodinil, 89 (19); o,p'-DDD, 89 (18); dichlorvos, 82 (21); endosulfan sulfate, 80 (27); imazalil, 77 (33); imidacloprid, 96 (16); linuron, 89 (19); methamidophos, 87 (17); methomyl, 96 (17); procymidone, 91 (20); pymetrozine, 69 (19); tebuconazole, 89 (15); tolylfluanid (in grapes and oranges), 68 (33); and trifluralin, 85 (20). For incurred pesticides, kresoxim-methyl (9.2 +/- 3.2 ng/g) and cyprodinil (112 +/- 18) were found in the grapes; permethrins (112 +/- 41), lamda-cyhalothrin (58 +/- 11), and imidacloprid (12 +/- 2) were determined in the lettuces; and ethion (198 +/- 36), thiabendazole (53 +/- 8), and imazalil (13 +/- 4) were determined in the oranges. Chlorpyrifosmethyl (200 ng/g) was used as a quality control standard added during sample homogenization and yielded 86% recovery and 19% RSD(R). Intralaboratory repeatabilities for the method averaged 9.8% RSD for all analytes. The results demonstrate that the method is fit-for-purpose to monitor many pesticide residues in fruits and vegetables, and the Study Director recommends that it be adopted Official First Action.  相似文献   

2.
A gas chromatography/mass spectrometry (GC/MS) method was developed to study the pharmacokinetics of ligustilide following oral administration to rats. The method was used for the analysis of samples taken from rats. Biological samples were prepared by liquid-liquid extraction (LLE) using an n-hexane-ether (2:1) solvent mixture for a sample clean-up step and analyzed by GC/MS with a quadrupole MS detector in selected ion monitoring mode (m/z 190). The calibration curves were linear over the concentration range 0.172-8.60 microg/mL (r > 0.99) for blood samples and a different range (r > 0.99) for different tissue samples. The limit of detection (LOD) was 1.0 ng/mL or 1.0 ng/g (three times the signal-noise ratio). Within- and between-day precision expressed as the relative standard deviation (RSD) for the method was 1.58-3.88 and 2.99-4.91%, respectively. The recovery for all samples was >80%, except for liver samples (>70%). The main pharmacokinetic parameters obtained were: T(max) = 0.65 +/- 0.07 h, C(max) = 1.5 +/- 0.2 microg/mL, AUC = 34 +/- 6 h microg/mL and K(a) = 3.5 +/- 0.6/h. The experimental results showed that ligustilide was easily absorbed, but its elimination was slow, from 3 to 12 h after oral administration. The concentrations of ligustilide in rat cerebellum, cerebrum, spleen and kidney were higher than those in other organs.  相似文献   

3.
Steroid determination by immunoassays results in significant interferences and inaccurate results. This study describes the development and validation of a new gas chromatographic-mass spectrometric method for the simultaneous quantification of 17alpha-hydroxyprogesterone (17alphaOHP), testosterone (T), dehydroepiandrosterone (DHEA), androstenedione (Delta4-A), cortisol (F) and pregnenolone (Preg) in serum of neonates. Steroids were extracted and purified from 0.5 mL serum using diethyl ether and Extrelut mini NT1 column. The extracts were derivatized with N-methyl-N-trimethylsilyl-trifluoroacetamide (MSTFA)/trimethylsilyl iodide (TMSI)/dithioerythritol (DTE) and the resulting trimethylsilyl derivatives were quantified by gas chromatography-selected ion monitoring-mass spectrometry (GC-SIM-MS). The detection limit for all steroids was lower than 0.1 ng/mL. The limit of quantification was 0.1 ng/mL for all steroids except cortisol which was at 0.25 ng/mL. d3-Testosterone and methyltestosterone served as internal standards. Precision for all compounds at the concentrations of 0.5, 1, 5 and 10 ng/mL (n = 10) in fortified steroid-free serum samples ranged from 0.8% to 16.6%. Accuracy was calculated at the concentrations of 0.5, 1, 5 and 10 ng/mL and ranged from -9.2% to 10.6% (n = 10). Linear calibration equations were obtained for all five steroids (0.125-31.25 ng/mL) and for cortisol (0.125-200 ng/mL). Relative recoveries at concentrations 1.0 and 12.5 ng/mL ranged from 70.5% to 97.5%. Absolute recoveries at the same concentrations ranged from 73.2% to 96.6%. Reference intervals were estimated for infants aged from 9 to 40 days. The proposed steroid profile is suitable for routine analysis and provides meaningful data for samples within normal range as well as those with elevated levels.  相似文献   

4.
Alkaloid extracts of four Amaryllidaceae species were studied with respect to their acetylcholinesterase and butyrylcholinesterase inhibitory activity and alkaloid patterns. Twenty-one alkaloids were determined by GC/MS, and seventeen of them identified from their mass spectra and retention times. The GC/MS analysis of the alkaloid extract of Nerine filamentosa is the first phytochemical investigation of this species. Promising erythrocytic acetylcholinesterase inhibitory activity was demonstrated by the alkaloid extracts of Narcissus poeticus var recurvus, Nerine filifolia and N. filamentosa (IC(50,HuAChE) = 6.0 +/- 0.1 microg/mL; IC(50,HuAChE) = 18.5 +/- 0.8 microg/mL, IC(50,HuAChE) = 21.6 +/- 1.1 microg/mL). The most potent inhibitory activity against serum butyrylcholinesterase was shown by extracts of Sternbergia lutea and Nerinefilamentosa (IC(50,HuBuChE) = 3.7 +/- 0.1 microg/mL; IC(50.HuBuChE) = 13.0 +/- 0.7 microg/mL).  相似文献   

5.
A sensitive and specific method for the quantitative determination of clodronate in human plasma is presented. The drug was extracted from plasma by anion-exchange chromatography and derivatised to the tetra-tert-butyldimethylsilyl derivative. 18O3-Clodronate was prepared from unlabeled clodronate and used as an internal standard. Gas chromatography/mass spectrometry (GC/MS) under electron ionisation conditions was used for quantitative measurement of the drug, using m/z 643.16 and 651.17 for target and internal standard, respectively. Calibration graphs were linear within the range of 10-1280 ng/mL plasma. Intra-day precision was 1.8% (10 ng/mL), 0.5% (40 ng/mL), 1.0% (120 ng/mL), 0.5% (200 ng/mL), 0.5% (400 ng/mL) and 2.7% (800 ng/mL) and inter-day variability was found to be 0.7% (10 ng/mL), 1.6% (40 ng/mL), 1.3% (120 ng/mL), 2.3% (200 ng/mL), 2.5% (400 ng/mL) and 1.2% (800 ng/mL). Intra-day accuracy showed deviations of 0.8% (10 ng/mL), 0.8% (40 ng/mL), 0.9% (120 ng/mL), 0.9% (200 ng/mL), 1.9% (400 ng/mL) and 0.3% (800 ng/mL) and intra-day accuracy was of -1.4% (10 ng/mL), 0.0% (40 ng/mL), -0.7% (120 ng/mL), -0.4% (200 ng/mL), -1.2% (400 ng/mL) and -3.3% (800 ng/mL). The stable isotope labeled standard was found to be stable under analysis conditions.  相似文献   

6.
A new analytical approach, based on derivatization with 2,2,2-trichloroethyl chloroformate and gas chromatography/mass spectrometry (GC/MS), was investigated for qualitative and quantitative analyses of a large range of amphetamine-related drugs and ephedrines in plasma, urine and hair samples. Sample preparation involved alkaline extraction of analytes from biological samples using Extrelut columns, after addition of the internal standard 3,4-methylenedioxypropylamphetamine (MDPA), and subsequent derivatization to produce 2,2,2-trichloroethylcarbamates. GC/MS analyses, in splitless mode using a slightly polar 30-m capillary column, were performed with quadrupole or ion trap instruments. MS acquisition modes were electron ionization (EI) in full-scan or selected ion monitoring (SIM) modes (quadrupole), and full-scan MS or MS/MS modes with chemical ionization (CI) conditions (ion trap). EI spectra of 2,2,2-trichloroethylcarbamates showed variably abundant molecular ions as well as abundant diagnostic fragment ions, both characterized by ion clusters reflecting the isotope distribution of three chlorine atoms in the derivatized molecules. CI spectra showed abundant protonated molecules. Quantitative studies using EI SIM conditions gave recoveries in the range 74-89%, linear response over ranges of 10-2000 ng/mL (plasma and urine) and 0.20-20 ng/mg (hair), with corresponding limits of detection in the ranges 2-5 ng/mL and 0.1-0.2 ng/mg. Potential applications (following full method validation) include clinical and forensic toxicology, as well as doping control.  相似文献   

7.
This paper describes a rapid gas chromatographic/mass spectrometric (GC/MS) screening method for the detection of drugs of abuse and/or their metabolites in urine. Synthetic stimulants, opiates, cocaine metabolites, cannabinoids--and specifically the acid metabolite of tetrahydrocannabinol (THC-COOH)--can be simultaneously extracted by a single liquid/liquid separation step, at alkaline pH, and assayed as trimethylsilyl derivatives by GC/MS in SIM (selected ion monitoring) mode. All the analytes show a good linearity (R2 > 0.99 for most of the considered substances) in the range 25-1000 ng/mL, with a good reproducibility of both the retention times (CV% <0.7) and the relative abundances of the characteristic diagnostic ions (CV% <13). The limit of detection (LOD) of the method is 25 ng/mL of target compound in human urine for most of the substances investigated, 3 ng/mL for THC-COOH, and 10 ng/mL for norbuprenorphine. Validation of the method allows its application to different fields of forensic analytical toxicology, including antidoping analysis.  相似文献   

8.
《Analytical letters》2012,45(15):2311-2317
The present work describes the methodology and validation of gas chromatography with flame ionization (FID) and mass spectrometric (MS) detection after derivatization with N-Methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) for determination of atenolol with an internal standard (metoprolol) in pharmaceutical preparations. The linearity was established over the concentration range of 0.5–20 μg/mL for GC/FID and 12.5–500 ng/mL for GC/MS method. The intra- and inter-day relative standard deviation was less than 4.72 and 5.80%, respectively. Limit of quantification was determined as 500 ng/mL and 12.5 ng/mL for GC/FID and GC/MS, respectively. No interference was found from tablet excipients at the selected assay conditions. Developed GC/FID and GC/MS methods in this study are accurate, sensitive, and precise and can be easily applied to Tensinor tablet as pharmaceutical preparation.  相似文献   

9.
A lifetime controlled reference experiment has been performed using 42 veal calves, 21 males and 21 females which were fed and housed according to European regulations and common veterinary practice. During the experiment feed, water, urine and hair were sampled and feed intake and growth were monitored. Thus for the first time residue analysis data were obtained from guaranteed lifetime-untreated animals. The analysis was focused on the natural hormones estradiol and testosterone and their metabolites, on 17beta- and 17alpha-nortestosterone, on 17beta- and 17alpha-boldenone and androsta-1,4-diene-3,17-dione (ADD), and carried out by gas chromatography tandem mass spectrometry (GC/MS/MS), an estrogen bioassay and liquid chromatography (LC) MS/MS. Feed, water and hair samples were negative for the residues tested. Female calf urines showed occasionally low levels of 17alpha-estradiol and 17alpha-testosterone. On one particular sampling day male veal calf urines showed very high levels of 17alpha-testosterone (up to 1000 ng mL(-1)), accompanied by lower levels of estrone and 17beta-testosterone. Despite these extreme levels of natural testosterone, 17beta-boldenone was never detected in the same urine samples; even 17alpha-boldenone and ADD were only occasionally beyond CCalpha (maximum levels 2.7 ng mL(-1)). The data from this unique experiment provide a set of reference values for steroid hormones in calf urine and demonstrate that 17beta-boldenone is not a naturally occurring compound in urine samples.  相似文献   

10.
A method using an online solid-phase extraction (SPE) and ion-pairing liquid chromatography with electrospray tandem mass spectrometry (LC/ES-MS/MS) was developed for determination of amphetamine (Amp), methamphetamine (mAmp), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxyethylamphetamine (MDEA), and 3,4-methylenedioxymethamphetamine (MDMA) in urine samples. A SPE cartridge column with both hydrophilic and lipophilic functions was utilized for online extraction. A reversed-phase C18 LC column was employed for LC separation and MS/MS was used for detection. Trifluoroacetic acid was added to the mobile phase as an ion-pairing reagent. This method was fully automated and the extraction and analysis procedures were controlled by a six-port switch valve. Recoveries ranging from 85-101% were measured. Good linear ranges (10-500 ng/mL) for Amp and mAmp were determined. For MDA, MDMA and MDEA, dual linear ranges were obtained from 5-100 and 100-500 ng/mL, respectively. The detection limit of each analytical compound, based on a signal-to-noise ratio of 3, ranged from 1-3 ng/mL. The applicability of this newly developed method was examined by analyzing several urine samples from drug users. Good agreement was obtained between the results from this method and a literature GC/MS method.  相似文献   

11.
A simple dispersive liquid-liquid microextraction (DLLME) method based on solidification of a floating organic drop (DLLME-SFO) technique combined with gas chromatography/electron-capture detection (GC/ECD) or gas chromatography/mass spectrometry (GC/MS) has been developed. The proposed method is simple, low in cost, and of high precision. It overcomes the most important problem in DLLME, the high-toxic solvent used. Halogenated organic compounds (HOCs) in water samples were determined as the model compounds. The parameters optimized for the DLLME-SFO technique were as follows: A mixture of 0.5 mL acetone, containing 10 microL 2-dodecanol (2-DD-OH), was rapidly injected by syringe into the 5 mL water sample. After centrifugation, the fine 2-DD-OH droplets (8+/-0.5 microL) were floated at the top of the screwcap test tube. The test tube was then cooled in an ice bath. After 5 min the 2-DD-OH solvent had solidified and was then transferred into a conical vial; it melted quickly at room temperature and 3 microL (for GC/ECD) or 2 microL (for GC/MS) of it was injected into a gas chromatograph for analysis. The limit of detection (LOD) for this technique was 0.005-0.05microgL(-1) for GC/ECD and was 0.005-0.047 microgL(-1) for GC/MS, respectively. The linear range of the calibration curve of DLLME-SFO was from 0.01 to 500 microgL(-1) with a coefficient of estimation (r2)>0.996 for GC/ECD and was from 0.02 to 500 microgL(-1) with a coefficient of estimation (r2)>0.996 for GC/MS.  相似文献   

12.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of donepezil in human plasma samples. Diphenhydramine was used as the internal standard. The collision-induced transition m/z 380 --> 91 was used to analyze donepezil in selected reaction monitoring mode. The signal intensity of the m/z 380 --> 91 transition was found to relate linearly with donepezil concentrations in plasma from 0.1-20.0 ng/mL. The lower limit of quantification of the LC/MS/MS method was 0.1 ng/mL. The intra- and inter-day precisions were below 10.2% and the accuracy was between -2.3% and +2.8%. The validated LC/MS/MS method was applied to a pharmacokinetic study in which healthy Chinese volunteers each received a single oral dose of 5 mg donepezil hydrochloride. The non-compartmental pharmacokinetic model was used to fit the donepezil plasma concentration-time curve. Maximum plasma concentration was 12.3 +/- 2.73 ng/mL which occurred at 3.50 +/- 1.61 h post-dosing. The apparent elimination half-life and the area under the curve were, respectively, 60.86 +/- 12.05 h and 609.3 +/- 122.2 ng . h/mL. LC/MS/MS is a rapid, sensitive and specific method for determining donepezil in human plasma samples.  相似文献   

13.
Measurement of cortisol levels in body fluids is important for monitoring pituitary gland and adrenal functions. To develop a specific and standardized enzyme-linked immunosorbent assay (ELISA), a novel monoclonal anti-cortisol antibody has been generated using a reasonably designed haptenic derivative. Spleen cells were prepared from the BALB/c or A/J mouse, which had repeatedly been immunized with a conjugate of 4-(2-carboxyethylthio)cortisol (CET) and bovine serum albumin, to be fused with P3/NS1/1-Ag4-1 myeloma cells. After four fusion experiments, one hybridoma clone secreting a practical antibody has been established. The resulting monoclonal antibody CS#38 (isotype gamma1, kappa) showed an affinity constant (K(a)) for cortisol of 1 x 10(9) M(-1) and provided a practical calibration curve (detection limit, 0.26 ng per assay) in a homologous ELISA system employing horseradish peroxidase-labeled CET as a labeled antigen. Cross-reactivities with related C-21 steroids were acceptably low: 11-deoxycortisol (4.3%), cortisone (4.0%), corticosterone (1.9%), progesterone (1.6%), 17alpha-hydroxyprogesterone (12%), 6beta-hydroxycortisol (8.4%), and tetrahydrocortisol (< 0.1%). Urinary and serum cortisol levels of healthy volunteers were determined by this method after methylene chloride extraction to be 39.0 +/- 17.0 microg/day (n = 7) and 80.8 +/- 38.9 ng/mL (n = 10), respectively, both of which are in the reference range.  相似文献   

14.
After inhalation experiments with sandalwood oil and the pure fragrance compounds coumarin and alpha-terpineol, substances were detected and measured in the blood samples of test animals (mice) using gas chromatography/mass spectrometry (GC/MS) (MID) in connection with GC/FTIR (SWC), GC/AES (carbon and oxygen trace) and flame ionization detection/gas chromatography. Using tiglinic acid benzyl ester as the internal standard the following concentrations in serum could be found: alpha-santalol 6.1 ng/mL, beta-santalol 5.3 ng/mL and alpha-santalene 0.5 ng/mL. In separate inhalation experiments with coumarin and with alpha-terpineol the corresponding concentrations were 7.7 ng/mL and 6.9 ng/mL, respectively.  相似文献   

15.
Chuang JC  Emon JM  Durnford J  Thomas K 《Talanta》2005,67(3):658-666
An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within ±20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within ±20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30 ng/mL by ELISA and 0.2 ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10 mL of urine converted into 1 mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.  相似文献   

16.
A headspace solid-phase microextraction (HS-SPME) method using polydimethylsiloxane (PDMS)-coated fiber coupling with GC/self-ion molecule reaction (SIMR)/MS/MS (GC/SIMR/MS/MS) has been developed for the differentiation of o-, m-, and p-xylene isomers. The optimization parameters of this method are: extraction time 20 min, stirring rate 1200 rpm, sampling temperature 28 degrees C, and salt concentration 5%. The LODs were found to be in the range of 3-9 ng/mL under the SIM mode of GC/MS. The RSDs were below 1% (n=5). The linear dynamic range of the calibration curve was from 0.05 to 10.0 microg/mL with correlation coefficient (r2)>0.9089. The advantages of this technique are sensitive, selective, ease of operation, simple device, solvent free, and extremely little sample consumption. This technique is the first example using SIMR combined MS/MS applied in the GC/MS and it can be applied to other volatile compounds for future application.  相似文献   

17.
Five different mass spectrometers interfaced to GC or LC were evaluated for their application to targeted and nontargeted screening of pesticides in two foods, spinach and ginseng. The five MS systems were capillary GC/MS/MS, GC-high resolution time-of-flight (GC/HR-TOF)-MS, TOF-MS interfaced with a comprehensive multidimensional GC (GCxGC/TOF-MS), an MS/MS ion trap hybrid mass (qTrap) system interfaced with an ultra-performance liquid chromatograph (UPLC-qTrap), and UPLC interfaced to an orbital trap high resolution mass spectrometer (UPLC/Orbitrap HR-MS). Each MS system was tested with spinach and ginseng extracts prepared through a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) procedure. Each matrix was fortified at 10 and 50 ng/g for spinach or 25 and 100 ng/g for ginseng with subsets of 486 pesticides, isomers, and metabolites representing most pesticide classes. HR-TOF-MS was effective in a targeted search for characteristic accurate mass ions and identified 97% of 170 pesticides in ginseng at 25 ng/g. A targeted screen of either ginseng or spinach found 94-95% of pesticides fortified for analysis at 10 ng/g with GC/MS/MS or LC/MS/MS using multiple reaction monitoring (MRM) procedures. Orbitrap-MS successfully found 89% of 177 fortified pesticides in spinach at 25 ng/g using a targeted search of accurate mass pseudomolecular ions in the positive electrospray ionization mode. A comprehensive GCxGC/TOF-MS system provided separation and identification of 342 pesticides and metabolites in a single 32 min acquisition with standards. Only 67 or 81% of the pesticides were identified in ginseng and spinach matrixes at 25 ng/g or 10 ng/g, respectively. MS/MS or qTrap-MS operated in the MRM mode produced the lowest false-negative rates, at 10 ng/g. Improvements to instrumentation, methods, and software are needed for efficient use of nontargeted screens in parallel with triple quadrupole MS.  相似文献   

18.
Analysis of 4,4'-methylenebis(2-cholroaniline) (MOCA) or its metabolites in urine has been considered as the appropriate method to assess MOCA exposures through inhalation and skin absorption. MOCA and its metabolite, N-acetyl 4,4'-methylenebis(2-chloroaniline) (acetyl-MOCA), are analyzed using methods either limited by sensitivity or sample preparation. Therefore, a solid-phase extraction (SPE) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to simultaneously analyze MOCA and acetyl-MOCA in urine to serve as biomarkers for MOCA exposure. Protein was precipitated by using acetonitrile, and SPE were applied to clean up samples to eliminate the matrix effect and to improve the recovery. The limit of quantitation of this method was at 1.0 ng/mL for MOCA and 0.03 ng/mL for acetyl-MOCA (signal-to-noise (S/N) ratio = 10). Urinary MOCA and acetyl-MOCA levels in MOCA-exposed workers were analyzed and quantitated to be 191.9 +/- 373.2 (mean +/- standard deviation (SD)) and 11.79 +/- 23.8 ng/mL (N = 54) with the median values 38.6 and 1.8 ng/mL, respectively. MOCA concentrations are significantly correlated with their corresponding acetyl-MOCA levels in urine (Spearman correlation coefficient r = 0.916, p < 0.001). These results show that this method has been successfully developed and provides high-throughput potential to analyze MOCA and acetyl-MOCA to serve as exposure biomarkers for future study of the potential health effects associated with MOCA exposures.  相似文献   

19.
A GC/FID/MS method was developed for the identification and quantification of d-allethrin (DA) and its major impurities in commercial samples. Optimisation of the experimental conditions was carried out considering such important requirements as resolution, reproducibility, detection limits of 0.1% (m/m) for the impurities, and short analysis time. Under the optimised final conditions the method was validated for specificity, precision (CV% = 0.133 at 2.10 mg/mL and CV% = 0.035 at 3.00 mg/mL), linearity (0-3.00 microg injected), limits of detection (0.09 ng injected) and quantitation (0.28 ng injected), and robustness. The DA related impurities were identified by using a GC/MS method with ion trap mass detection and also by comparison with synthesised standards. The most abundant impurities were crysolactone, allethrolone, chrysanthemic acid, and chloro-derivatives of DA.  相似文献   

20.
This paper describes a sensitive and selective liquid chromatography with tandem mass spectrometry (LC-MS/MS) method for determination of the novel survivin suppressant YM155, 1-(2-methoxyethyl)-2-methyl-4,9-dioxo-3-(pyrazin-2-ylmethyl)-4,9-dihydro-1H-naphtho[2,3-d]imidazolium, which is developed for the treatment of solid tumors. This method uses a liquid-liquid extraction from 0.25 mL of dog plasma. LC separation was carried out on a Genesis Silica column (50 mm x 3.0 mm i.d.) at a flow-rate of 0.5 mL/min. Compounds were eluted using a mobile phase of 5 mm ammonium acetate and 0.1% formic acid in water-0.1% formic acid in acetonitrile, 17:83 (v/v). MS/MS detection was carried out with an MDS-Sciex API3000 triple quadrupole mass spectrometer in positive electrospray ionization mode. The standard curve was linear from 0.05 to 50 ng/mL (r > or = 0.9968). The lower limit of quantitation was 0.05 ng/mL. Good intra- and inter-day assay precision (within 7.4% RSD) and accuracy (within +/-12.3%) were obtained. The extraction recovery was 66.2%. The method was successfully applied to preclinical pharmacokinetic studies in dogs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号