首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
ICP-MS法测定菊花茶中砷镉铜铅锌   总被引:20,自引:0,他引:20  
采用电感耦合等离子体质谱(ICP-MS)法,对菊花茶中微量元素砷、铅、镉、铜、锌进行了分析。用HNO3-H2O2消解样品,通过在线加入内标校正基体效应和接口效应,通过修正方程校正质量数干扰。测定元素校正曲线的相关系数都在0.999 5以上,各元素的检出限在0.020~0.14μg.L-1,样品分析结果的相对标准偏差为1.5%~4.3%(n=10),加标回收率在93.9%~101.6%之间。用此方法测定茶叶标准物质GBW 07605,结果与标准值基本一致。  相似文献   

2.
建立大葱中Fe、Mn、Zn、Cu等4种元素的电感耦合等离子体质谱(ICP-MS)测定方法。样品采用微波消解,以Ge为内标,ICP-MS测定各元素含量。结果表明,该法精密度RSD值1.01%~1.33%,回收率98.8%~101.5%,检出限0.013~0.035?g/m L。该法灵敏、准确、快捷,符合大葱中微量元素测定要求。  相似文献   

3.
根据欧盟玩具安全新指令( 2009/48/EC)的要求,应用电感耦合等离子体质谱(ICP-MS)法测定玩具材料中硼、铝、铬、锰、钴、镍、铜、锌、砷、硒、锶、镉、锡、锑、钡、汞、铅17种可迁移元素含量,使用碰撞反应池技术消除某些多原子离子干扰.方法检出限为0.5~75μg/kg,加标回收率在85.4%~109%之间,相对...  相似文献   

4.
建立了微波消解-电感耦合等离子体质谱(ICP-MS)法测定4种纳米银抗菌产品中多种微量元素的分析方法。比较了湿法消解和微波消解这两种样品前处理方法对样品测定的影响,探讨了消除汞记忆效应的方法,并研究了待测元素的质谱干扰的消除。实验结果表明,采用Au(100μg/L)+HCl(2%)能较好地消除Hg的记忆效应。与湿法消解相比,微波消解可短时间消解样品并获得好的Hg回收率。在优化ICP-MS条件后,各元素线性相关系数均大于0.999。采用微波消解-ICP-MS法对样品进行加标回收,样品加标回收率在84.0%~109%,相对标准偏差在0.97%~13.2%。方法快速、简便,能够满足纳米银抗菌产品中微量元素的定量测定。  相似文献   

5.
应用ICP-MS法同时测定海产品中汞含量的分析方法。样品前处理采用微波消解法, 并对微波消解条件作了优化;采用以铋作内标的外部校准法。对照分析了参考标准物质。结果表明,在0.10-50.00μg·L-1范围内呈线性关系(r=0.9997),回收率为95%-104%,相对标准偏差为1.4%-3.5%。  相似文献   

6.
ICP-MS法测定土壤中十五种稀土元素   总被引:3,自引:0,他引:3  
采用微波消化土壤样品,通过优化等离子体功率、雾化器流量等仪器参数,找出最佳的测定条件,直接测定了土壤中Y、La、Ce、Pr、Nd、Sm、Eu、Gd、Tb、Dy、Ho、Er、Tm、Yb、Lu15种稀土元素含量。结果表明,各个元素的方法检出限为0.004—0.024ng/mL,样品的检出下限为0.09—0.30ng/mL,结果较为满意。  相似文献   

7.
采用Na2O2熔融分解样品,运用电感耦合等离子体发射光谱法(ICP-AES)和电感耦合等离子体质谱法(ICP-MS)测定光学玻璃中的稀土元素。采用该方法对国家一级标准物质GBW07158、GBW07159、GBW07160和GBW07161进行测定,其结果表明与标准值相符。方法选择性好、灵敏度好、定量准确,适用于光学玻璃中稀土元素的测定,结果令人满意。  相似文献   

8.
参芪降糖颗粒中微量元素与其疗效关系的研究   总被引:2,自引:0,他引:2  
采用电感耦合等离子体质谱(ICP-MS)法,对参芪降糖颗粒中的二十种元素进行了分析,同时用塞曼测汞仪测定了样品中汞元素的含量。结果表明,参芪降糖颗粒对糖尿病的疗效与其中的微量元素有关。  相似文献   

9.
以8-羟基喹啉三氯甲烷萃取分离铝合金样品溶液中的铝,结合高分辨电感耦合等离子体质谱仪,建立一种测定铝合金中微量锡的新方法.结果表明,该方法检出限为0.0007 ng/mL,相对标准偏差小于4%,加标回收率在96.0%~103.0%之间.与其它传统方法相比,该方法的测试结果更接近样品的真实值.  相似文献   

10.
样品用盐酸-硝酸-氢氟酸-高氯酸密闭分解,加入硫酸至冒烟,冷却后制备成硝酸介质溶液,使用电感耦合等离子体质谱(ICP-MS)法测定La,Ce,Pr,Nd,Sm;用过氧化钠熔融分解,水提取沉淀分离,沉淀用硝酸溶解,使用ICP-MS法测定Y,Eu,Gd,Tb,Dy,Ho,Er,Tm,Yb,Lu。根据岩石标准物质的分析结果评价方法的准确度和精密度。方法检出限(6σ)为0.002~0.021μg/g,相对标准偏差(n=12)为1.2%~9.6%,方法可用于批量岩石中稀土元素的测定。  相似文献   

11.
ICP-MS法测定栽培甘草中的十种微量元素   总被引:1,自引:0,他引:1  
采用电感耦合等离子体质谱仪(ICP-MS)测定了栽培甘草中的十种微量元素。结果表明,方法中各元素标准曲线的r2值均在0.99以上,回收率为91.21%~108.65%,RSD值为3.6%~8.9%。该法精密度高、准确性好、干扰较少、快速简单,可用于甘草中微量元素的含量测定。  相似文献   

12.
建立了电感耦合等离子体质谱(ICP-MS)法测定果蔬类、大米等农产品样品中痕量元素的方法.样品通过HNO3-H2 O2混酸体系微波消解,以Rh作为内标溶液消除基体干扰,在仪器最佳条件下测定植物样中镉、铅、铬、铜、镍、锌6种痕量元素.方法的检出限为0.002~0.5μg/g;相对标准偏差(RSD)为0.84% ~7.4%...  相似文献   

13.
Determination of Trace Elements in Super Alloy by ICP-MS   总被引:1,自引:0,他引:1  
 A method is described for determination of 14 trace elements in super alloy certified reference material. Inconel 718 by ICP-MS. The interferences were investigated in detail. By using appropriate settings of the operational parameters and correcting interferences the elements without interference free isotopes were also analyzed. Non-spectral interference to the analytes was studied. No matrix separation or any other sample pretreatment but acid dissolution was made. 14 trace elements (B, Sc, Ga, Ge, In, Sn, Sb, Te, Hf, Ag, Ce, Tl, Pb and Bi) were analyzed by matrix matched standard solution calibration and using Rh as internal standard. Good agreement was achieved between the found levels and the certified values for most of the elements. The RSD (n = 4) of the determination values of Ce was lower than 20%, and RSD of the other 13 elements was lower than 10%. Received July 21, 2000. Revision May 29, 2001.  相似文献   

14.
ICP-MS法测定彭泽贝母中微量元素的含量及形态分析   总被引:2,自引:0,他引:2  
目的:测定彭泽贝母中微量元素含量,研究彭泽贝母中微量元素的存在形态,探讨微量元素的含量和形态.方法:采用HNO3-H2O2微波消解体系,电感耦合等离子质谱法(ICP-MS)测定彭泽贝母中铅、钙、铁、锰、锌、镉、钡、铬等10种微量元素的含量,初步探究微量元素的存在形态.结果:Ca元素在彭泽贝母中含量最高,而Mo元素含量最低;彭泽贝母中微量元素是以无机态为主、多种形态共存的复杂体系.结论:彭泽贝母中含有丰富的人体必需微量元素,可能促进其有效成分作用的发挥.  相似文献   

15.
以3 mL HNO3和2 mL H2O2的混合消解液对烟草样品进行微波消解,采用电感耦合等离子体质谱测定了烤烟中的Mn、Zn、Cu、Se、N i、Co、Cr、As、Cd、Pb 10种微量元素的含量.结果表明:方法的检出限均低于0.02μg/g,各元素测定的RSD(n=5)均小于3%,样品加标回收率为97.35%-101.30%.方法消耗试剂少,快速准确,适合烟草中多种微量元素的同时测定.  相似文献   

16.
古汉养生精中微量元素的ICP-MS分析   总被引:3,自引:0,他引:3  
本文报道用ICP—MS法同时测定样品中Pb、As、Cu、Zn、Cd、Cr、Ni、Mn等8种微量元素。样品用微波消解。对影响测定的各种因素进行了研究,实验确定了最佳测定条件。本法的检出限为0.01~0.08μg/L,回收率为92.11%~112.82%,RSD小于4.30%。方法准确、快速、简便,应用于古汉养生精中微量元素的测定,结果满意。  相似文献   

17.
电感耦合等离子体质谱法测定原油中微量元素   总被引:1,自引:0,他引:1  
原油样品用硝酸和过氧化氢经高压密闭消解罐消解处理,采用电感耦合等离子体质谱法测定其中镁、铝、钒、铬、镍、铜、锌、钼、镉和铅等10种微量元素的含量。10种元素的检出限(3s)在0.012~0.300μg·g~(-1)之间。方法用于S-21油标准样品分析,测定值与认定值相吻合,相对标准偏差(n=5)在0.5%~5.0%之间。10种元素的回收率在93.3%~116.0%之间。  相似文献   

18.
采用微波消解技术,建立了一种电感耦合等离子体质谱法测定明胶空心胶囊中Cr,Co,Ni,Cu,Zn,As,Cd,Hg和Pb 9种微量重金属元素的方法。确定了微波消解仪和等离子体质谱仪的最佳操作参数,研究共存离子的干扰和消除方法,选择了各元素的测定同位素,以Ge,Rh和Tl为内标补偿基体效应,建立了样品测定方法。应用拟定的方法测定了不同生产厂家、不同批次的空心胶囊中微量重金属的含量。方法对试样中各元素测定的相对标准偏差为1.5%~14.1%,加标回收率在90.0%~102.0%。结果表明,方法简便、快速、灵敏,满足于空心胶囊中9种重金属元素的测定要求。  相似文献   

19.
研究了利用电感耦合等离子体质谱仪测定无尘产品中的痕量杂质元素氯含量的方法,检测下限0.06 ng/mL,精密度RSD<5%(n=7),回收率93.7%~110.0%。  相似文献   

20.
ICP-MS分析人血清中微量元素   总被引:2,自引:0,他引:2  
用ICP-MS分析人血清中22种元素。为克服基体抑制效应。采用内标元素Sc和In分别校正质量数80以下和80以上元素的测定,获得满意的结果。通过对牛血清标准物质的测定,检验分析结果的准确性和方法的可靠性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号