首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An ultra‐performance liquid chromatography–tandem mass spectrometric (UPLC‐MS/MS) method was developed and validated to determine AV‐45 in rat plasma. After the addition of the internal standard benzophenone, plasma samples were pretreated by protein precipitation. Chromatographic separation was achieved on an Acquity UPLC BEH C18 column (50 × 2.1 mm, 1.7 µm) by gradient elution at a flow rate of 0.4 mL/min. Detection of analytes and internal standard (IS) was done by tandem mass spectrometry, operating in positive‐ion and multiple reaction monitoring mode. The method was fully validated for its sensitivity, selectivity, accuracy and precision, matrix effect and stability study. The calibration curve showed good linearity over the concentration range 2.00–1000 ng/mL for AV‐45. Intra‐ and inter‐day precisions were less than 7.6%, and accuracy ranged from 100.6 to 107.8%. There was no matrix effect. The validated method was successfully applied to a pharmacokinetic study of AV‐45 in rats. Additionally, the metabolism of AV‐45 in rat liver microsomes was also studied by ultra‐performance liquid chromatography combined with time‐of‐flight mass spectrometry (UPLC/TOF‐MS). With the help of chromatographic behavior and accurate mass measurements, the metabolites were characterized. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
An ultra‐high‐performance liquid chromatography–mass spectrometry (UPLC/MS/MS) method was developed and validated for the quantification of trimethylamine‐N‐oxide (TMAO) simultaneously with TMAO‐related molecules l ‐carnitine and γ‐butyrobetaine (GBB) in human blood plasma. The separation of analytes was achieved using a Hydrophilic interaction liquid chromatography (HILIC)‐type column with ammonium acetate–acetonitrile as the mobile phase. TMAO determination was validated according to valid US Food and Drug Administration guidelines. The developed method was successfully applied to plasma samples from healthy volunteers. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
To implement and validate an analytical method by ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC MS/MS) to quantify mycophenolic acid (MPA) in kidney transplant patients. Quantification of MPA was performed in an ACQUITY UPLC H Class system coupled to a Xevo TQD detector and it was extracted from plasma samples by protein precipitation. The chromatographic separation was achieved through an ACQUITY HSS C18 SB column with 0.1% formic acid and acetonitrile (60:40 vol/vol) as mobile phase. The pharmacokinetic parameters were calculated by non‐compartmental analysis of MPA plasma concentrations from 10 kidney transplant patients. The linear range for MPA quantification was 0.2–30 mg/L with a limit of detection of 0.07 mg/L; the mean extraction recovery was 99.99%. The mean intra‐ and inter‐day variability were 2.98% and 3.4% with a percentage of deviation of 8.4% and 6.6%, respectively. Mean maximal concentration of 10 mg/L at 1.5 h, area under the concentration–time curve of 36.8 mg·h/L, elimination half‐life of 3.9 h, clearance of 0.32 L/h/kg and volume of distribution of 1.65 L/kg were obtained from MPA pharmacokinetics profiles. A simple, fast and reliable UPLC–MS/MS method to quantify MPA in plasma was validated and has been applied for pharmacokinetic analysis in kidney transplant patients.  相似文献   

4.
5.
A rapid, sensitive and specific ultra‐high‐performance liquid chromatography coupled with tandem mass spectrometry (UPLC‐MS/MS) method was developed to investigate the pharmacokinetics and tissue distribution of Eclipta prostrata extract. Rats were orally administrated the 70% ethanol extract of E. prostrata, and their plasma as well as various organs were collected. The concentrations of seven main compounds, ecliptasaponin IV, ecliptasaponin A, apigenin, 3′‐hydroxybiochanin A, luteolin, luteolin‐7‐O‐glucoside and wedelolactone, were quantified by UPLC‐MS/MS through multiple reactions monitoring method. The precisions (RSD) of the analytes were all <15.00%. The extraction recoveries ranged from 74.65 to 107.45% with RSD ≤ 15.36%. The matrix effects ranged from 78.00 to 118.06% with RSD ≤ 15.04%. To conclude, the present pharmacokinetic and tissue distribution studies provided useful information for the clinical usage of Eclipta prostrata L.  相似文献   

6.
Stellera chamaejasme L. has been used as a traditional Chinese medicine for the treatment of scabies, tinea, stubborn skin ulcers, chronic tracheitis, cancer and tuberculosis. A sensitive and selective ultra‐high liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method was developed and validated for the simultaneous determination of five flavonoids (stelleranol, chamaechromone, neochamaejasmin A, chamaejasmine and isochamaejasmin) of S. chamaejasme L. in rat plasma. Chromatographic separation was accomplished on an Agilent Poroshell 120 EC‐C18 column (2.1 × 100 mm, 2.7 μm) with gradient elution at a flow rate of 0.4 mL/min and the total analysis time was 7 min. The analytes were detected using multiple reaction monitoring in positive ionization mode. The samples were prepared by liquid–liquid extraction with ethyl acetate. The UPLC‐MS/MS method was validated for specificity, linearity, sensitivity, accuracy and precision, recovery, matrix effect and stability. The validated method exhibited good linearity (r ≥ 0.9956), and the lower limits of quantification ranged from 0.51 to 0.64 ng/mL for five flavonoids. The intra‐ and inter‐day precision were both <10.2%, and the accuracy ranged from −11.79 to 9.21%. This method was successfully applied to a pharmacokinetic study of five flavonoids in rats after oral administration of ethyl acetate extract of S. chamaejasme L.  相似文献   

7.
Methamphetamine abuse continues as a major problem in the USA owing to its powerful psychological addictive properties. AZ66, 3‐[4‐(4‐cyclohexylpiperazine‐1‐yl)pentyl]‐6‐fluorobenzo[d]thiazole‐2(3H)‐one, an optimized sigma receptor ligand, is a promising therapeutic agent against methamphetamine. To study the in vivo pharmacokinetics of this novel sigma receptor ligand in rats, a sensitive ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed in rat plasma and validated. The developed method requires a small volume of plasma (100 μL) and a simple liquid–liquid extraction. The chromatographic separations were achieved in 3.3 min using an Acquity UPLC BEH Shield RP18 column. The mass spectrophotometric detection was carried out using a Waters Micromass Quattro MicroTM triple‐quadrupole system. Multiple reaction monitoring was used for the quantitation with transitions m/z 406 → m/z 181 for AZ66 and m/z 448 → m/z 285 for aripiprazole. The method was validated over a concentration range of 1–3500 ng/mL and the lower limit of quantitation was determined to be 1 ng/mL. Validation of the assay demonstrated that the developed UPLC/MS/MS method was sensitive, accurate and selective for the determination of AZ66 in rat plasma. The present method has been successfully applied to an i.v. pharmacokinetic study in Sprague–Dawley rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
The purpose of this study was to develop an ultra‐performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method of 22 antiepileptics for routine therapeutic monitoring. The antiepileptics used in the analyses were carbamazepine, carbamazepine‐10,11‐epoxide, clobazam, N‐desmethylclobazam, clonazepam, diazepam, N‐desmethyldiazepam, ethosuximide, felbamate, gabapentin, lamotrigine, levetiracetam, N‐desmethylmesuximide, nitrazepam, phenobarbital, phenytoin, primidone, tiagabine, topiramate, valproic acid, vigabatrin and zonisamide. After protein precipitation of 50 μL plasma with methanol, the supernatant was diluted with water or was evaporated to dryness and reconstituted with mobile phase in the case of benzodiazepines. Separation was achieved on an Acquity UPLC BEH C18 column with a gradient mobile phase of 10 mm ammonium acetate containing 0.1% formic acid and methanol at a flow rate of 0.4 mL/min. An Acquity TQD instrument in multiple reaction monitoring mode with ion mode switching was used for detection. All antiepileptics were detected and quantified within 10 min, with no endogenous interference. All the calibration curves showed good linearity in the therapeutic range (r2 < 0.99). The precision and accuracy values for intra‐ and inter‐assays were within ±15% except for phenobarbital and tiagabine. A good correlation was observed between the concentration of clinical samples measured by the new method described here and the conventional methods. The values of carbamazepine and phenytoin by UPLC‐MS/MS were lower than those detected by the immunoassays, which might be caused by the cross‐reaction of antibodies with their metabolites. In conclusion, we developed a simple and selective UPLC‐MS/MS method suitable for routine therapeutic monitoring of antiepileptics. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
A reliable high‐throughput ultra‐high performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method was developed and validated for oleanolic acid (OA) determination in rat plasma and liver tissue using glycyrrhetic acid as the internal standard (IS). Plasma and liver homogenate samples were prepared using solid‐phase extraction. Chromatographic separation was achieved on a C18 column using an isocratic mobile phase system. The detection was performed by multiple reaction monitoring mode via positive electrospray ionization interface. The calibration curves showed good linearity (R2 > 0.9997) within the tested concentration ranges. The lower limit of quantification for plasma and liver tissue was ≤0.75 ng/mL. The intra‐ and inter‐day precision and accuracy deviations were within ±15% in plasma and liver tissue. The mean extraction recoveries ranged from 80.8 to 87.0%. In addition, the carryover, matrix effect, stability and robustness involved in the method were also validated. The method was successfully applied to the plasma and hepatic pharmacokinetics of OA after oral administration to rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
Fast and efficient ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) analysis of short interfering RNA oligonucleotides was used for identity confirmation of the target sequence‐related impurities. Multiple truncated oligonucleotides and metabolites were identified based on the accurate mass, and their presumed sequence was confirmed by MS/MS and MSE (alternating low and elevated collision energy scanning modes) methods. Based on the resulting fragmentation of native and chemically modified oligonucleotides, it was found that the MSE technique is as efficient as the traditional MS/MS method, yet MSE is more general, faster, and capable of producing higher signal intensities of fragment ions. Fragmentation patterns of modified oligonucleotides were investigated using RNA 2′‐ribose substitutions, phosphorothioate RNA, and LNA modifications. The developed sequence confirmation method that uses the MSE approach was applied to the analysis of in vitro hydrolyzed RNA oligonucleotide. The target RNA and metabolites, including the structural isomers, were resolved by UPLC, and their identity was confirmed by MSE. Simultaneous RNA truncations from both termini were observed. The UPLC quadrupole time‐of‐flight (QTOF) MS/MS and MSE methods were shown to be an effective tool for the analysis and sequence confirmation of complex oligonucleotide mixtures. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
The authors' laboratory at one time employed four liquid chromatography/mass spectrometric (LC/MS) methods for the detection of a large variety of drugs in equine urine. Drug classes covered by these methods included anti-diabetics, anti-ulcers, cyclooxygenase-2 (COX-2) inhibitors, sedatives, corticosteroids, anabolic steroids, sulfur diuretics, xanthines, etc. With the objective to reduce labour and instrumental workload, a new ultra performance liquid chromatography/tandem mass spectrometric (UPLC/MS/MS) method has been developed, which encompasses all target analytes detected by the original four LC/MS methods. The new method has better detection limits than the superseded methods. In addition, it covers new target analytes that could not be adequately detected by the four LC/MS methods. The new method involves solid-phase extraction (SPE) of two aliquots of equine urine using two Abs Elut Nexus cartridges. One aliquot of the urine sample is treated with β-glucuronidase before subjecting to SPE. A second aliquot of the same urine sample is processed directly using another SPE cartridge, so that drugs that are prone to decomposition during enzyme hydrolysis can be preserved. The combined eluate is analysed by UPLC/MS/MS using alternating positive and negative electrospray ionisation in the selected-reaction-monitoring mode. Exceptional chromatographic separation is achieved using an UPLC system equipped with a UPLC(?) BEH C18 column (10 cm L×2.1 mm ID with 1.7 μm particles). With this newly developed UPLC/MS/MS method, the simultaneous detection of 140 drugs at ppb to sub-ppb levels in equine urine can be achieved in less than 13 min inclusive of post-run equilibration. Matrix interference for the selected transitions at the expected retention times is minimised by the excellent UPLC chromatographic separation. The method has been validated for recovery and precision, and is being used regularly in the authors' laboratory as an important component of the array of screening methods for doping control analyses of equine urine samples.  相似文献   

12.
In this study, a specific and quick ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method was fully developed and validated for simultaneous measurement of the rat plasma levels of vortioxetine (VOR), Lu AA34443 (the major metabolite of VOR), fluoxetine and its metabolite norfluoxetine with diazepam as the internal standard (IS). After a simple protein precipitation with acetonitrile for sample preparation, the separation of the analytes were performed on an Acquity UPLC BEH C18 (2.1 × 50 mm, 1.7 μm) column, with acetonitrile and 0.1% formic acid in water as mobile phase by gradient elution. The detection was achieved on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via an electrospray ionization source. Good linearity was observed in the calibration curve for each analyte. The data of precision, accuracy, matrix effect, recovery and stability all conformed to the bioanalytical method validation of acceptance criteria of US Food and Drug Administration recommendations. The newly developed UPLC–MS/MS method allowed simultaneous quantification of VOR, fluoxetine and their metabolites for the first time and was successfully applied to a pharmacokinetic study in rats.  相似文献   

13.
On‐line ultra‐performance liquid chromatography (UPLC) coupled with diode‐array detection (UPLC/DAD) and electrospray ionization quadrupole time‐of‐flight mass spectrometry (ESI‐Q‐TOF‐MS) were used for separation, identification and structural analyses of saponins in Rhizoma Paridis saponins (RPS) and rat plasma after oral administration of RPS. Thirty steroidal saponins in RPS were identified by comparing their retention time, accurate mass measurement and positive and negative mass spectrometry data with that of reference compounds. The UPLC/Q‐TOF‐MS method was proved to be rapid and efficient in that 30 steroidal saponins, including three kinds of saponins (prototype, pennogenyl and diosgenyl saponins) were tentatively characterized within 6 min. After oral administration of RPS, 21 original saponins were absorbed in RPS‐treated rat plasma. Our results indicated that UPLC/Q‐TOF‐MS is a rapid and effective tool for identification of a series of saponins at trace level. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
建立了固相萃取-超高效液相色谱/串联质谱法检测人体血清中邻苯二甲酸二(2-乙基已基)酯(DEHP)代谢物.血清样品中加入乙酸钠溶液及内标13C4邻苯二甲酸单乙基已基酯(13C4MEHP)后,在37℃条件下用β-葡萄糖醛苷酶酶解提取12h,提取液经MAX固相萃取小柱净化并浓缩到纯水中.以甲醇5 mmol/L乙酸铵溶液为流动相,经Waters UPLC(R)HSS T3色谱柱分离后,在电喷雾离子源负离子模式下,以多反应监测(MRM)方式进行扫描,内标法定量.DEHP代谢物在1.0~100.0 μg/L范围内线性关系良好,检出限均为0.1 μg/kg,回收率89.6%~103.2%.该方法灵敏度高,准确度好,可作为监测人群内暴露的重要技术支撑.  相似文献   

15.
Nucleosides are an important class of metabolites and have been investigated as potential tumor biomarkers. A method based on ultra peerformance liquid chromatography (UPLC)-TOF MS was developed to analyze urinary nucleosides and other metabolites with cis-diol structure to distinguish between cancer patients and healthy persons and compare the results with those obtained by HPLC. The data showed that the UPLC method used about one third of the time required by HPLC and achieved a much better chromatographic resolution and increased sensitivity, the number of peaks detected by UV being 79 and 94 for HPLC and UPLC, respectively. With UPLC-TOF MS, more information was obtained about metabolites, the separation of cancer patients from healthy persons was significantly improved, and more potential biomarkers were found. The method based on UPLC-TOF MS is a powerful technique for the study of metabolite profiles.  相似文献   

16.
Gigantol is a typical bibenzyl compound isolated from Dendrobii Caulis that has been widely used as a medicinal herb in China for the treatment of diabetic cataract, cancer and arteriosclerosis obliterans and as a tonic for stomach nourishment, saliva secretion promotion and fever reduction. However, few studies have been carried out on its in vivo metabolism. In the present study, a rapid and sensitive method based on ultra‐performance liquid chromatography/electrospray ionization quadrupole time‐of‐flight tandem mass spectrometry (UPLC‐Q/TOF‐MS) in positive ion mode was developed and applied to identify the metabolites of gigantol in rat urine after a single oral dose (100 mg/kg). Chromatographic separation was performed on an Acquity UPLC HSS T3 column (100 × 2.1 mm i. d., 1.8 µm) using acetonitrile and 0.1% aqueous formic acid as mobile phases. A total of 11 metabolites were detected and identified as all phase II metabolites. The structures of the metabolites were identified based on the characteristics of their MS, MS2 data and chromatographic retention times. The results showed that glucuronidation is the principal metabolic pathway of gigantol in rats. The newly identified metabolites are useful to understand the mechanism of elimination of gigantol and, in turn, its effectiveness and toxicity. As far as we know, this is the first attempt to investigate the metabolic fate of gigantol in vivo. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
Currently, pharmacokinetic–pharmacodynamic studies of sedatives and analgesics are performed in neonates and children to find suitable dose regimens. As a result, sensitive assays using only small volumes of blood are necessary to determine drug and metabolite concentrations. We developed an ultra‐performance liquid chromatographic method with tandem mass spectrometry detection for quantification of midazolam, 1‐hydroxymidazolam, hydroxymidazolamglucuronide, morphine, morphine‐3‐glucuronide and morphine‐6‐glucuronide in 100 μL of plasma. Cleanup consisted of 96 wells micro‐solid phase extraction, before reversed‐phase chromatographic separation (ultra‐performance liquid chromatography) and selective detection using electrospray ionization tandem mass spectrometry. Separate solid‐phase extraction methods were necessary to quantify morphine, midazolam and their metabolites because of each group's physicochemical properties. Standard curves were linear over a large dynamic range with adequate limits of quantitation. Intra‐ and interrun accuracy and precision were within 85–115% (of nominal concentration using a fresh calibration curve) and 15% (coefficient of variation, CV) respectively. Recoveries were >80% for all analytes, with interbatch CVs (as a measure of matrix effects) of less than 15% over six batches of plasma. Stability in plasma and extracts was sufficient, allowing large autosampler loads. Runtime was 3.00 min per sample for each method. The combination of 96‐well micro‐SPE and UPLC‐MS/MS allows reliable quantification of morphine, midazolam and their major metabolites in 100 μL of plasma. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
The capability of ultra performance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC/TOFMS) in the high-throughput quantitative analysis of a drug candidate in plasma has been investigated. Data obtained were compared with results from conventional analysis by high-performance liquid chromatography with tandem mass spectrometric detection on a triple quadrupole instrument (HPLC/MS/MS). The accuracies and precisions of the two approaches were comparable. The UPLC/TOFMS system displayed excellent robustness over the course of 276 injections of protein-precipitated plasma samples. With the instrumentation used, the limits of detection and quantification were approximately five-fold higher with UPLC/TOFMS than for HPLC/MS/MS. Nevertheless, the UPLC/TOFMS system proved adequate to quantify plasma concentrations of a drug molecule administered orally to rats at a pharmacologically relevant dose of 4 mg/kg. As well as providing quantitative data on the test compound, it was also possible to extract data for eight different metabolites, including several isomeric species (three +O and three +2O) from the UPLC/TOFMS data sets, using an analytical method with a 2.5-minute run time. Selectivity for the test compound and its metabolites was derived from the accurate mass capabilities of the TOF instrument, and no MS method development was required.  相似文献   

19.
A simple, sensitive and specific ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC‐MS/MS) method was developed to determine the newly synthesized compound lipoic acid–niacin dimer (N2L) in plasma. Plasma samples were precipitated by methanol using tetrahydropalmatine as internal standard. Chromatographic separation was achieved on an Acquity BEH C18 (2.1 × 50 mm i.d., 1.7 µm) column; the mobile phase contains methanol and buffer solution (water with 0.5% formic acid and 10 mmol/L ammonium acetate). Multiple reaction monitoring (m/z 353.9 → 148.6 for N2L and m/z 356.0 → 192.0 for internal standard) was performed for detection and quantification. The method was validated to be rapid, specific, accurate and precise over the concentration range of 1–750 ng/mL; N2L was not stable on the bench‐top or during freeze–freeze‐thaw cycles in plasma, but was stable in the stock solution and after preparation in the autosampler for 24 h. The utility of the assay was confirmed by pharmacokinetic study of N2L in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
Schisandra chinensis Baill grows wild in Russia, China, Korea and Japan, and its fruit has been found to be effective in amnesia and insomnia. It is enriched in schisandra lignans (SL) that are major components responsible for therapeutic action. However, there are no reports on the biotransformation analysis of SL. An ultra‐performance liquid chromatography/electrospray‐ionization high‐definition mass spectrometry (UPLC‐Q‐TOF‐HDMS) method was developed to investigate the metabolism of SL in vivo. MS was performed on a Waters Micromass high‐definition system with an electrospray ionization source in positive ion mode and automated MetaboLynx software analysis with excellent MS accuracy and enhanced MS data acquisition. An improved mass defect filter (MDF) method employing both drug and core structure filter templates was applied to the processing of UPLC‐Q‐TOF‐HDMS data for the detection and structural characterization of metabolites. In this study, 30 metabolites were detected and identified in vivo, and demethylation and hydroxylation were confirmed as the primacy metabolic pathway for SL in rat plasma. In conclusion, the presently developed methodology was suitable for biotransformation research of SL and will find wide use in metabolic studies for other herbal medicines. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号