首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
We have developed a novel phase-resolved optical coherence tomography (OCT) and optical Doppler tomography (ODT) system that uses phase information derived from a Hilbert transformation to image blood flow in human skin with fast scanning speed and high velocity sensitivity. Using the phase change between sequential scans to construct flow-velocity imaging, this technique decouples spatial resolution and velocity sensitivity in flow images and increases imaging speed by more than 2 orders of magnitude without compromising spatial resolution or velocity sensitivity. The minimum flow velocity that can be detected with an axial-line scanning speed of 400 Hz and an average phase change over eight sequential scans is as low as 10 microm/s, while a spatial resolution of 10 microm is maintained. Using this technique, we present what are to our knowledge the first phase-resolved OCT/ODT images of blood flow in human skin.  相似文献   

2.
We report the development of an optical technique for noninvasive imaging of in vivo blood flow dynamics and tissue structures with high spatial resolution (2-10 microm) in biological systems. The technique is based on optical Doppler tomography (ODT), which combines Doppler velocimetry with optical coherence tomography to measure blood flow velocity at discrete spatial locations. The exceptionally high resolution of ODT permits noninvasive in vivo imaging of both blood microcirculation and tissue structures surrounding the vessel, which has significance for biomedical research and clinical applications. Tomographic imaging of in vivo blood flow velocity in the chick chorioallantoic membrane and in rodent skin is demonstrated.  相似文献   

3.
光学相干层析多普勒成像功能拓展研究   总被引:8,自引:0,他引:8  
光学多普勒成像(Optical Doppler tomography,ODT)是一种结合了光学相干层析成像技术(Opticalcoherence tomography,OCT)和多普勒流速仪的非侵入、非接触的成像技术,能够实现对高散介质组织内部的血管分布和血液流速的探测。阐述了基于数字希尔伯特变换的相位分离多普勒光学相干层析成像技术的工作原理,并且通过对玻璃毛细管和生物芯片微通道管中聚苯乙烯溶液流速的实验测量,准确测量管内微粒缓慢移动时的多普勒频移量,获得了玻璃管内和生物芯片微通道管中流速分布曲线,证实了所提方法的可行性。获取的多普勒图像具有较高的空间分辨力和速度分辨力,在未来的临床应用中有潜在的应用价值。  相似文献   

4.
Study on cerebral microcirculation by Optical Doppler Tomography   总被引:1,自引:0,他引:1  
Optical Doppler Tomography (ODT) provides a novel method to measure the blood flow velocity in vessels with the diameter at micrometer scale. Rats with cranial window are used as a model, and the changes in the blood flow velocity of cerebral arterioles in sensory cortex are measured in real time with an established ODT system, under electrical stimulation and drug administration. The results show significant differences in the blood flow velocity between experimental groups and control groups, demonstrating the feasibility of ODT in the cerebral microcirculation study. Compared with the conventional Doppler ultrasound, ODT provides much higher spatial resolution, and thus holds a promising future in the application of the cerebral microcirculation study, especially in the observation of the blood flow velocity in micrometer scale vessels. Supported by the National Hi-Tech Research and Development Program of China (863 Program)(Grant No. 2006AA02Z4E0), the National Natural Science Foundation of China (Grant Nos. 60378041, 60478040, 60878057 and 30770685), the Program for New Century Excellent Talents in University (Grant No. NCET-04-0528), and the Opening Project of MOE Key Laboratory of Laser Life Science, South China Normal University  相似文献   

5.
An optical Doppler tomography (ODT) system that permits imaging of fluid flow velocity in highly scattering media is described. ODT combines Doppler velocimetry with the high spatial resolution of low-coherence optical interferometry to measure fluid flow velocity at discrete spatial locations. Tomographic imaging of particle flow velocity within a circular conduit submerged 1 mm below the surface in a highly scattering phantom of Intralipid is demonstrated.  相似文献   

6.
光学多普勒层析三维矢量测速方法研究   总被引:1,自引:0,他引:1  
光学多普勒层析术(ODT)是一种高分辨、非侵入的生物医学成像手段,能同时得到组织的结构信息和组织内血管的流速信息.提出了一种新型的基于相位分辨技术的ODT三维矢量测速方法.在ODT系统样品臂的准直镜和聚焦透镜之间加入窄带相位片,形成三个不同的相位延迟,通过计算多普勒频移和不同相位延迟下的多普勒展宽,可得到毛细管内的三维矢量流场分布.对已知浓度的聚苯乙烯溶液进行了一系列不同角度和不同流速的实验,结果证明这种新型的ODT矢量测速方法可以较精确的实现三维矢量流速的测量.  相似文献   

7.
Ren H  Du C  Pan Y 《Optics letters》2012,37(8):1388-1390
Speckle contrast based optical coherence angiography (OCA) and optical coherence Doppler tomography (ODT) have been applied to image cerebral blood flow previously. However, the contrast mechanisms of these two methods are not fully studied. Here, we present both flow phantom and in vivo animal experiments using ultrahigh-resolution OCA (μOCA) and ODT (μODT) to investigate the flow sensitivity differences between these two methods. Our results show that the high sensitivity of μOCA for visualizing minute vasculature (e.g., slow capillary beds) is due to the enhancement by random Brownian motion of scatterers (e.g., red and white blood cells) within the vessels; whereas, μODT permits detection of directional flow below the Brownian motion regime (e.g., laser-induced microischemia) and is, therefore, more suitable for brain functional imaging.  相似文献   

8.
The laser-welded coaxial-type laser module packages using an on-line monitoring system (OLMS) is presented. The OLMS is integrated with an ultra high precision laser displacement meter (LDM) and a laser welding system that enables to quantitatively on-line process the successive postweld shift (PWS) measurements by the LDM and corrections by the laser welding during multiple welding compensations in laser-welded laser module packages. The results show that the high-yield laser module packages with high coupling efficiency of 86-97% are obtained. The fiber shifts due to the PWS could be realigned back closer to their original position after applying multiple welding compensations, and hence the coupling powers loss due to the PWS could be recovered. This OLMS study has provided a practical package guideline for fabricating reliable laser module packages with high yield and high coupling efficiency for use in low-cost lightwave transmission systems.  相似文献   

9.
The turbulent asymptotic suction boundary layer is studied using a one-dimensional turbulence (ODT) model. ODT is a fully resolved, unsteady stochastic simulation technique. While flow properties reside on a one-dimensional domain, turbulent advection is represented using mapping events whose occurrences are governed by a random process. Due to its reduced spatial dimensionality, ODT achieves major cost reductions compared to three-dimensional (3D) simulations. A comparison to recent direct numerical simulation (DNS) data at moderate Reynolds number (Re = u / v0 = 333, where u and v0 are the free stream and suction velocity, respectively) suggests that the ODT model is capable of reproducing several velocity statistics, i.e. mean velocity and turbulent kinetic energy budgets, while peak turbulent stresses are under-estimated by ODT. Variation of the Reynolds number in the range Re ∈ [333,400,500,1000] shows that ODT can reproduce various trends observed as a result of increased suction in turbulent asymptotic suction boundary layers, i.e. the reduction of Reynolds stresses and enhanced skin friction. While up to Re = 500 our results can be directly compared to recent LES data, the simulation at Re = 1000 is currently not feasible through full 3D simulations, hence ODT may assist the design of future DNS or LES simulations at larger Reynolds numbers.  相似文献   

10.
目前,激光是治疗葡萄酒色斑(Port Wine Stain,PWS)最有效的疗法.然而,由于选择性光热效应机理研究的欠缺,PWS的临床彻底清除率依然很低(<20%).本文利用鼠脊视窗模型研究了不同激光参数照射下血管中光凝块和血栓的演变规律,以期为开发新的治疗策略提供依据.实验结果表明,Nd:YAG激光(1064 nm)...  相似文献   

11.
We developed a micro multipoint laser Doppler velocimeter (μ-MLDV) for noninvasive in-vivo measurements of blood flow and we presented the results of demonstrations performed on experimental animals. In this paper, we investigate the validity of power spectrum analysis for determining the flow velocity and the minimum power of the semiconductor laser in the μ-MLDV. Although average velocity is generally estimated from a peak position (f peak) in the power spectrum, the power spectrum of blood flow included an additional component in the high-frequency region. The conventional method for determining the average velocity of flows of transparent artificial fluids, which involves determining the average velocity from f peak, is unsuitable for in-vivo measurements of blood flow. The laser power was reduced from 140 to 30mW since 30mW was the minimum power at which images of blood flow velocity in microvessels could be obtained. About 30mW (power density of 15mW/mm2) is the maximum power which can be irradiated to humans. Further reduction in the laser power is necessary before this technique can be applied to humans.  相似文献   

12.
13.
An ultraintense laser injected a 10 J of power at 1.053 microm in 0.5 ps into a glass capillary of 1 cm long and 60 microm in diameter and accelerated plasma electrons to 100 MeV. One- and two-dimensional particle codes describe wakefields with 10 GV/m gradient excited behind the laser pulse, which are guided by a plasma density channel far beyond the Rayleigh range. The blueshift of the laser spectrum supports that a plasma of 10(16) cm(-3) is inside the capillary. A bump at the high energy tail suggests the electron trapping in the wakefield.  相似文献   

14.
Using interferometry, we investigate the dynamics of interaction of a relativistically intense 4-TW, 400-fs laser pulse with a He gas jet. We observe a stable plasma channel 1 mm long and less than 30 microm in diameter, with a radial gradient of electron density approximately 5 x 10(22) cm(-4) and with an on-axis electron density approximately ten times less than its maximum value of 8 x 10(19) cm(-3). A high radial velocity of the surrounding gas ionization of approximately 3.8 x 10(8) cm/s has been observed after the channel formation, and it is attributed to the fast ions expelled from the laser channel and propagating radially outward. We developed a kinetic model which describes the plasma channel formation and the subsequent ambient gas excitation and ionization. Comparing the model predictions with the interferometric data, we reconstructed the axial profile of laser channel and on-axis laser intensity. The estimated maximum energy of accelerated ions is about 500 keV, and the total energy of the fast ions is 5% of the laser pulse energy.  相似文献   

15.
We demonstrate extended axial flow velocity detection range in a time-domain Doppler optical coherence tomography (DOCT) system using a modified Kasai velocity estimator with computations in both the axial and transverse directions. For a DOCT system with an 8 kHz rapid-scanning optical delay line, bidirectional flow experiments showed a maximum detectable speed of >56 cm/s using the axial Kasai estimator without the occurrence of aliasing, while the transverse Kasai estimator preserved the approximately 7 microm/s minimum detectable velocity to slow flow. By using a combination of transverse Kasai and axial Kasai estimators, the velocity detection dynamic range was over 100 dB. Through a fiber-optic endoscopic catheter, in vivoM-mode transesophageal imaging of the pulsatile blood flow in rat aorta was demonstrated, for what is for the first time to our knowledge, with measured peak systolic blood flow velocity of >1 m/s, while maintaining good sensitivity to detect aortic wall motion at <2 mm/s, using this 2D Kasai technique.  相似文献   

16.
Kim J  Oh J  Milner TE  Nelson JS 《Optics letters》2006,31(6):778-780
We introduce a novel contrast mechanism for imaging blood flow by use of magnetomotive optical Doppler tomography (MM-ODT), which combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect erythrocytes moving according to the field gradient. Hemoglobin contrast was demonstrated in a capillary tube filled with moving blood by imaging the Doppler frequency shift, which was observed independently of blood flow rate and direction. Results suggest that MM-ODT may be a promising technique with which to image blood flow.  相似文献   

17.
Li P  Ni S  Zhang L  Zeng S  Luo Q 《Optics letters》2006,31(12):1824-1826
We discovered that laser speckle temporal contrast analysis (LSTCA) is able to access the two-dimensional (2D) cerebral blood flow velocity and vessel structure through the intact rat skull. It is demonstrated that LSTCA can significantly suppress the influence of the laser speckle from the stationary structure, such as the skull, and thus reveal the blood flow and morphology of blood vessels through the laser speckle images recorded from the intact rat skull.  相似文献   

18.
Quasi two-dimensional random site percolation model objects have been prepared using a synchrotron radiation lithography technique with a spatial resolution better than 50 microm and an aspect ratio of up to 17. Flow of water through the pore space was studied with the aid of an NMR velocity mapping method and compared with a computational fluid dynamics simulation. In order to be able to measure and map widely distributed flow velocities with microscopic resolution (typically 40 x 40 microm), an experimental protocol that permits one to cover an effectively very wide velocity field of view (0.6-10 mm/s) had to be developed.  相似文献   

19.
为了研究流场中碳纤维增强环氧树脂复合材料在激光辐照时产生的烧蚀羽烟对入射激光的屏蔽效应,通过对朗伯-比尔定律进行分析,得到了评价羽烟消光性能的平均质量消光系数的表达式,其与羽烟场浓度和激光透过率相关。采用激光诱导炽光法(LII)和激光消光法,搭建了羽烟消光性能联合诊断实验平台,使待测激光落于LII的激发光平面上,通过同步采集待测激光的透过率和LII信号,获得激发光平面上羽烟浓度场和激光消光比,得到羽烟在不同气流速度下的平均质量消光系数。实验得到气流速度为7,10,20m/s时羽烟对1064nm激光的归一化质量消光系数分别为2.51,1.08,1.00。实验发现,质量消光系数受到气流速度影响,当气流速度较低时质量消光系数曲线波动幅度大,且曲线均值较大;当气流速度较高时质量消光系数趋于稳定且均值较小。  相似文献   

20.
A gradient echo rapid velocity and acceleration imaging sequence (GERVAIS) has been developed and implemented to image liquid flow within a narrow packed bed. Two-dimensional velocity images have been acquired with an in-plane pixel size of 781 microm x 781 microm, with a data acquisition time of 20 ms for a single velocity component. Images of the x, y and z velocity vectors are reported. Data are reported for Reynolds numbers (based on particle diameter) of 200 and 300. In each case, GERVAIS images are compared with the results of a standard spin-echo phase-encoding velocity measurement. At Re = 200, steady-state flow is expected and the velocity images acquired using both techniques are consistent. At Re = 300, the GERVAIS sequence is able to image the unsteady-state flow field within this system. In contrast, the standard phase-encoding velocity measurement contains significant artefacts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号