首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes the development and partial validation of a fast, sensitive and specific ultra‐performance liquid chromatography/tandem mass spectrometric method for the determination of 3‐indoxyl sulfate (3‐IS), an endogenous compound in mammals, in mouse plasma and brain samples. The analytical method involves direct dilution of samples with water and protein precipitation with acetonitrile containing an internal standard, followed by separation of 3‐IS on a MonoChrom C18 column and detected by selected reaction monitoring (SRM) in negative ionization mode using turbo ion‐spray ionization. Due to high endogenous levels of 3‐IS in control mouse plasma and brain, blank guinea pig plasma and brain were used for the preparation of standard curves and quality controls (QCs). The compound of interest was well separated from interference peaks from the matrices with a total runtime of 2.7 min under a gradient condition. The method was partially validated. The linear concentration range was 0.1 to 100 µg/mL in mouse plasma and 10 to 10,000 ng/g in mouse brain. Inter‐assay mean bias and relative standard deviation (RSD) for plasma were in the range of ?4.8% to 3.1% and 2.5% to 3.2%, respectively. Intra‐assay mean bias and RSD for plasma were in the range of ?3.3% to 1.4% and 1.9% to 2.8%, respectively. Inter‐assay mean bias and RSD for brain were in the range of ?1.8% to 3.5% and 1.7% to 8.1%, respectively. Intra‐assay mean bias and RSD for brain were in the range of ?1.7% to 3.9% and 4.1% to 7.3%, respectively. The lower limit of quantitation (LLOQ) for this assay was 0.1 µg/mL for plasma and 10 ng/g for brain. The matrix effect was not observed in both guinea pig plasma and mouse plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
A sensitive, specific, accurate and reproducible high-performance liquid chromatography (HPLC) analytical method was developed and validated for the quantification of the novel oral taxane analogue BAY59-8862 in mouse plasma and tissue samples. A fully automated solid-phase extraction procedure was applied to the plasma after internal standard (IS) addition, with only 0.2 mL volume of the sample loaded on a CN-Sep-pak cartridge. In the case of the tissues a very simple acetonitrile extraction was used to recover BAY59-8862 and its internal standard from liver. The procedure for the quantification of BAY59-8862 and its IS (IDN5127) is based on high-performance liquid chromatography/ion spray-tandem mass spectrometry, operating in selected ion monitoring mode. The retention times of BAY and IS were 7.21 and 10.36 min, respectively. In both plasma and tissue specimens the assay was linear in the range 50-5000 ng/mL (ng/g). The overall precision and accuracy were assessed on three different days. The results for plasma were within 6.1% (precision) and between 99 and 112% (accuracy), and for the liver samples within 7.3% and between 104 and 118%, respectively. The LOD was 5 ng/mL and 20 ng/g in the plasma and liver, respectively. In addition, the biliary excretion of the compound in rats was studied. The study showed that an oxidative chemical reaction was the preferred metabolic pathway for biliary excretion, and two sets of mono- and dihydroxylated metabolites were detected by LC/ISP-MS/MS experiments. With this method, BAY59-8862 pharmacokinetic was determined in mice. The combined results demonstrate that the methodology can be considered a valid approach to conduct pharmacokinetic and metabolic studies during preclinical and clinical investigations.  相似文献   

3.
Determination of Se in biological materials was attempted by microwave-induced plasma mass spectrometry (MIP-MS). (1) Serum samples were available after 10 times dilution with 0.5% nitric acid solution containing 0.1% Triton X-100. When oxygen gas was inserted into the plasma gas (nitrogen) in order to improve the combustion, the sensitivity was reduced to 45%. The detection limit of this method was 0.5 ng/mL. (2) Standard reference materials on commercial base were used to evaluate the accuracy of the Se determination by MIP-MS after microwave digestion. In samples like bovine liver and human hair with Se concentrations of more than 0.7 μg/g, the standard curve method after internal standard (IS) correction was acceptable. This procedure was unsuitable for samples with low Se concentrations such as milk powder (certified value of Se 0.11 μg/g), or plant leaf samples. (3) Instead of IS correction, the peak height of the spectrum was used for calculations from the matrix matched calibration curve. The results of all materials were close to the certified values, even at 25 ng/g. The detection limit of the MIP-MS with microwave digestion and IS correction was 0.05 ng/mL in standard solutions. The detection limit of the peak height method was 0.1 ng/mL and was estimated to be < 20 ng/g in plant materials. Received: 25 September 1998 / Revised: 15 February 1999 / Accepted: 18 February 1999  相似文献   

4.
Determination of Se in biological materials was attempted by microwave-induced plasma mass spectrometry (MIP-MS). (1) Serum samples were available after 10 times dilution with 0.5% nitric acid solution containing 0.1% Triton X-100. When oxygen gas was inserted into the plasma gas (nitrogen) in order to improve the combustion, the sensitivity was reduced to 45%. The detection limit of this method was 0.5 ng/mL. (2) Standard reference materials on commercial base were used to evaluate the accuracy of the Se determination by MIP-MS after microwave digestion. In samples like bovine liver and human hair with Se concentrations of more than 0.7 μg/g, the standard curve method after internal standard (IS) correction was acceptable. This procedure was unsuitable for samples with low Se concentrations such as milk powder (certified value of Se 0.11 μg/g), or plant leaf samples. (3) Instead of IS correction, the peak height of the spectrum was used for calculations from the matrix matched calibration curve. The results of all materials were close to the certified values, even at 25 ng/g. The detection limit of the MIP-MS with microwave digestion and IS correction was 0.05 ng/mL in standard solutions. The detection limit of the peak height method was 0.1 ng/mL and was estimated to be < 20 ng/g in plant materials.  相似文献   

5.
A high-performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of muraglitazar, a novel alpha/gamma, dual PPAR activator, in monkey plasma. The method utilized trazodone as the internal standard (IS). The extraction scheme involved a simple protein precipitation procedure with the use of a mixture of acetonitrile and methylene chloride. Separation was carried out on a BDS Hypersil C(18) analytical column (2 x 50 mm, 3 microm) and an effective chromatographic separation of muraglitazar (3.31 min) and trazadone (2.27 min) was achieved at a ssow rate of 0.3 mL/min. The mobile phase, used in an isocratic mode, consisted of 90% A (acetonitrile: 0.1% formic acid, 50:50 v/v) and 10% B (acetonitrile: 0.1% formic acid, 95:5 v/v). Detection of muraglitazar and trazodone was by positive ion turbo-ion spray mass spectrometry in the SIM mode. The mass spectrometer was programmed to admit the protonated molecules at m/z 372.0 (IS) and m/z 517.1 (muraglitazar). The standard curve, which ranged from 2 to 500 ng/mL, was fitted to a 1/x weighted linear regression model. The between run precision and within-run precision values of the assay was within 6.2% RSD. The assay accuracy was within 10.0% of the nominal values of the range of QC samples (6.0-400 ng/mL). At the lower limit of quantitation (LLQ) of 2 ng/mL, the deviation of the predicted concentrations from the nominal value of LLQ samples (n = 6) were within +/-16.6%. Muraglitazar was stable in monkey K(3)EDTA plasma for at least three freeze-thaw cycles. The processed samples (spiked samples) were stable for 48 h in auto-sampler at 10 degrees C. The average extraction recoveries of muraglitazar and IS were 83.3 and 91.9%, respectively. The assay was applied to delineate the pharmacokinetic disposition of muraglitazar in monkeys following a single oral dose.  相似文献   

6.
To support the pharmacokinetic and bioavailability study of a once-daily fexofenadine/pseudoephedrine combination, a high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (HPLC/ESI-MS/MS) method for the simultaneous quantification of fexofenadine and pseudoephedrine was developed and validated with 500 microL human plasma using mosapride as an internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 502/466 for fexofenadine, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited linear dynamic ranges of 1-500 ng/mL and 2-1000 ng/mL for fexofenadine and pseudoephedrine, respectively, in human plasma. The lower limits of quantification were 1 and 2 ng/mL with a relative standard deviation of less than 10% for fexofenadine and pseudoephedrine, respectively. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time was 2 min and more than 400 human plasma samples could be analyzed in one day by running the system overnight. The method is precise and sensitive enough for its intended purpose.  相似文献   

7.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

8.
A highly sensitive, simple and selective high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed and applied to the determination of bergenin concentration in human plasma. Bergenin and the internal standard (IS) thiamphenicol in plasma were extracted with ethyl acetate, separated on a C(18 )reversed-phase column, eluted with mobile phase of acetonitrile-water, ionized by negative ion pneumatically assisted electrospray and detected in the multi-reaction monitoring mode using precursor --> product ions of m/z 327.1 --> 192 for bergenin and 354 --> 185.1 for the IS, respectively. The linear range of the calibration curve for bergenin was 0.25-60 ng mL(-1), with the lowest limit of quantification of 0.25 ng mL(-1), and the intra/inter-day relative standard deviation (RSD) was less than 10%. The method is suitable for the determination of low bergenin concentration in human plasma after therapeutic oral doses, and has been first and successfully used for its pharmacokinetic studies in healthy Chinese volunteers.  相似文献   

9.
In this study, a new LC‐ESI‐MS/MS‐based method was validated for the quantitation of hemslecin A in rhesus monkey plasma using otophylloside A as internal standard (IS). Hemslecin A and the IS were extracted from rhesus monkey plasma using liquid–liquid extraction as the sample clean‐up procedure, and were subjected to chromatography on a Phenomenex Luna CN column (150 × 2.0 mm, 3.0 µm) with the mobile phase consisting of methanol and 0.02 mol/mL ammonium acetate (55:45, v/v) at a flow rate of 0.2 mL/min. Detection was performed on an Agilent G6410B tandem mass spectrometer by positive ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 580.5 [M + NH4]+ → 503.4 and m/z 518.2 [M + NH4]+ → 345.0 for hemslecin A and IS, respectively. The assay was linear over the concentration range of 0.5–200 ng/mL and was successfully applied to a pharmacokinetic study in rhesus monkeys. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
A sensitive and specific method using high-performance liquid chromatography (LC)-tandem mass spectrometry (MS) for the analysis of total ribavirin in human red blood cells (RBC) is developed and validated. The method involves the addition of an internal standard and perchloric acid, the conversion of ribavirin phosphorylated metabolites to ribavirin, purification with a solid-phase exchange cartridge, and LC-MS-MS analysis. The MS-MS is selected to monitor m/z 245-113 for ribavirin and m/z 250-113 for [13C]ribavirin using positive electrospray ionization. The calibration curve is linear over a concentration of 100-10,000 ng/mL with a limit of quantitation of 100 ng/mL. Mean interassay accuracy for quality control (QC) at 100, 1000, and 10,000 ng/mL are 101.8%, 99.4%, and 98.8%, respectively. Mean interassay precision (%CV) for QC at 100, 1000, and 10,000 ng/mL are 5.0%, 5.0%, and 2.5%, respectively. Extractibility of total ribavirin from RBC is confirmed with RBC obtained from a [(14)C]ribavirin-dosed monkey. The method is used to determine the free and total ribavirin concentration in human RBC obtained from hepatitis C patients treated with ribavirin.  相似文献   

11.
A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of amlodipine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase C(18) column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 409/238 for amlodipine and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 50-10,000 pg/mL for amlodipine in human plasma. The lower limit of quantification was 50 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of amlodipine and the IS from spiked plasma samples were 74.7 +/- 4.6 and 72.1 +/- 2.0%, respectively. A run time of 1.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. The observed maximum plasma concentration (Cmax) of amlodipine (2.5 mg oral dose) was 1425 pg/mL, time to observed maximum plasma concentration (Tmax) was 8.1 h and elimination half-life (T(1/2)) was 50.1 h.  相似文献   

12.
A simple, rapid and sensitive LC-MS/MS bioanalytical method has been developed to simultaneously quantify Camptosar (CPT-11) and its active metabolite, SN-38, in mouse plasma and tissues. A single step protein precipitation with acetonitrile in 96-well plates was used for sample preparation. Camptothecin (CPT) was used as the internal standard. Fast separation of SN-38, CPT-11 and CPT was carried out isocratically on a C18, 2 mm x 50 mm, 5 microm HPLC column with a mobile phase containing acetonitrile and 20 mM ammonium acetate (pH 3.5) and a 2.5 min chromatographic run time. The API 4000 MS/MS system was operated in positive ionization multiple reaction monitoring mode, and the transitions for SN-38, CPT-11 and CPT were 393.4 --> 349.3, 587.6 --> 167.2 and 349.3 --> 305.3, respectively. The SN-38 and CPT-11 concentrations in samples were calculated from a standard curve of peak area ratios of the analyte to that of the internal standard using a 1/chi2 weighted linear regression. The quantitation limit of 0.5 ng/mL was achieved by using a low sample volume (100 microL) of plasma or tissue homogenates. The assay was linear over the concentration range of 0.5-500 ng/mL with acceptable precision and accuracy. The method was used for the quantification of CPT-11 and SN-38 in plasma and tissues to support a preclinical pharmacokinetics and tissue distribution study of CPT-11 in mice.  相似文献   

13.
A rapid and sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed and validated for the determination of troglitazone in mouse plasma. Troglitazone and its internal standard (IS), rosiglitazone, were separated on an ACQUITY UPLC BEH C(18) column (1.7 microm particle size, 50 x 2.1 mm i.d.) by gradient elution with water and methanol at a flow rate of 0.5 mL/min. The cycle time of each analysis was 2.5 min. Rosiglitazone and troglitazone eluted at 1.13 and 1.57 min, respectively, and were chromatographically resolved from the ion suppression and enhancement zones due to the biological matrix effect. Quantitation of the analytes was performed in electrospray negative ionization mode (ESI -ve) using multiple reaction monitoring (MRM) experiments. The weighted (1/x) calibration curve was quadratic over the plasma concentration range 1-2500 ng/mL with a correlation coefficient (r(2)) of 0.9966. The limit of quantitation (LOQ) of troglitazone in mouse plasma was lower than 1 ng/mL. The inter- and intra-day variations of the assay were lower than 12.1%; the overall accuracy ranged from 86.4-110.2% and recovery from spiked plasma was more than 60%. The developed method was successfully applied to determine troglitazone in mouse plasma after intraperitoneal administration.  相似文献   

14.
A simple, sensitive and reproducible ultra‐performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of polychlorinated biphenyl (PCB) 77 and PCB 180 in mouse plasma. The sample preparation was performed by simple liquid–liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP18 column maintained at 35°C. Quantification was performed on a photodiode array detector set at 215 nm and PCB 101 was used as internal standard (IS). PCB 77, PCB 180, and IS retention times were 2.6, 4.7 and 2.8 min, respectively, and the total run time was 6 min. The method was validated for specificity, selectivity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 10–3000 ng/mL for PCB 77 and PCB 180. Intra‐ and inter‐day precisions for PCBs 77 and 180 were found to be good with CV <4.64%, and the accuracy ranged from 98.90 to 102.33% in mouse plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of PCBs 77 and 180 in mouse plasma.  相似文献   

15.
Tedizolid (TDZ) is a novel oxazolidinone class antibiotic, indicated for the treatment of acute bacterial skin and skin structure infections in adults. In this study a highly sensitive UPLC‐MS/MS assay was developed and validated for the determination of TDZ in rat plasma using rivaroxaban as an internal standard (IS). Both TDZ and IS were separated on an Acquity UPLC BEH? C18 column using an isocratic mobile phase comprising of acetonitrile–20 mm ammonium acetate (85:15, v/v), eluted at 0.3 mL/min flow rate. The plasma sample was processed by liquid liquid extraction technique using ethyl acetate as an extracting agent. The analyte and IS were detected in positive mode using electrospray ionization source. The precursor to product ion transitions at m/z 371.09 > 343.10 for TDZ and m/z 435.97 > 144.94 for IS were used for the quantification in multiple reaction monitoring mode. The calibration curve was linear in the concentration range of 0.74–1500 ng/mL and the lower limit of quantification was 0.74 ng/mL only. The developed assay was validated following standard guidelines for bioanalytical method validation (US Food and Drug Administration) and all the validation results were within the acceptable limits. The developed assay was successfully applied into a pharmacokinetic study in rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
A highly sensitive, specific and rapid LC‐ESI‐MS/MS method has been developed and validated for the quantification of rocilinostat in small volume mouse plasma (20 μL) using vorinostat as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a protein precipitation procedure with acetonitrile. Chromatography was achieved on Prodigy ODS‐2 column using a binary gradient using mobile phase A (0.2% formic acid in water) and B (acetonitrile) at a flow rate of 0.38 mL/min. The total chromatographic run time was 4.1 min and the elution of rocilinostat and IS occurred at ~3.2 and 2.9 min, respectively. A linear response function was established in the concentration range of 0.28–1193 ng/mL in mouse plasma. The intra‐ and inter‐day accuracy and precisions were in the ranges of 3.12–8.93 and 6.41–11.6%, respectively. This novel method has been applied to a pharmacokinetic study in mice. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

17.
A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of pseudoephedrine in human plasma using mosapride as internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple-reaction monitoring mode using the respective [M + H](+) ions, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited a linear dynamic range of 2-1000 ng/mL pseudoephedrine in human plasma. The lower limit of quantification was 2 ng/mL with a relative standard deviation of less than 9% for pseudoephedrine. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time of 2 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

18.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of ziprasidone (ZIP) in human plasma was developed. ZIP and N-methyl ziprasidone as internal standard (IS) were extracted from alkalinized plasma using tert- butyl methyl ether. Separation was performed isocratically on a C8 column with 90% acetonitrile containing 2 mmol/L ammonium acetate as a mobile phase with a total run time of 2.5 min. MS/MS transitions of m/z 413 --> 194 and m/z 427 --> 177 of the analyte and internal standard were used for quantification. Confirmatory ions of m/z 413 --> 177 and m/z 427 --> 180 were collected as well. The calibration curve based on peak-area ratio was linear up to at least 200 ng/mL with a detection limit of 0.1 ng/mL. The method showed satisfactory reproducibility with a coefficient of variation of less than 5%. The method was successfully applied to the analysis of ZIP in spiked human plasma.  相似文献   

19.
建立了测定人体血浆中非那雄胺药物浓度的液相色谱-质谱分析方法。色谱柱为Hypersil-Keystone C_(18)柱,流动相为乙腈∶水(含0.2%三氯乙酸)=55∶45(V/V),质谱选择电喷雾正离子源(ESI+),选择离子模式(SIM)监测,非那雄胺和内标卡马西平质荷比分别为m/z373和m/z237。血浆样品经乙腈去蛋白、离心和吹干后,残渣用流动相溶解。当非那雄胺的浓度在0.5~120ng·mL~(-1)范围时线性关系良好(r=0.999),检测限(S/N=3)为0.02ng·mL~(-1);日间和日内测定的精密度(RSD)分别在6.4%~2.2%和5.5%~1.7%之间;加标0.5ng·mL~(-1)、40ng·mL~(-1)和80ng·mL~(-1)非那雄胺的平均回收率(n=6)分别为108.5%、101.2%和98.7%。方法快速、准确和灵敏,已成功用于人血浆中非那雄胺浓度的测定和人体药代动力学研究。  相似文献   

20.
A simple, sensitive and reliable LC–MS/MS method was developed and validated for the quantification of anemoside B4, a potential antiviral constituent isolated from Pulsatilla chinensis in rat plasma, tissue, bile, urine and feces. All biological samples were prepared by protein precipitation method, and ginsenoside‐Rg1 was chosen as the internal standard (IS). The analyte and IS were separated using a C18 column (2.1 × 50 mm, 1.8 μm) and a mobile phase consisting of 0.1% formic acid in water (v /v) and acetonitrile running at a flow rate of 0.2 mL/min for 5 min. The multiple reaction monitoring transitions were monitored at m /z 1219.5–749.5 for anemoside B4 and 845.4–637.4 for ginsenoside‐Rg1 in electrospray ionization negative mode. The calibration curve was linear in the range of 10–2000 ng/mL for all biological matrices with a lower limit of quantification of 10 ng/mL. The validated method was successfully applied to a pharmacokinetics, tissue distribution and excretion study. These preclinical data will be beneficial for further development of anemoside B4 in future studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号