首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
Camptothecin, a plant alkaloid with antitumor activity, is a potent and rapidly acting inhibitor of DNA synthesis. The objective of this study was to develop a sensitive high-performance liquid chromatographic (HPLC) method for the detection and estimation of the camptothecin concentration in biological fluids. Using HPLC coupled with fluorescence detection, at an excitation wavelength of 370 nm and an emission wavelength of 434 nm, we found that the lower limits of detection for camptothecin in aqueous, plasma and urine samples were 0.5, 1 and 10 ng/ml, respectively. The ideal mobile phase used was methanol-10 mM potassium phosphate (75:25, v/v, pH 4.0). To determine the utilization of the method in a biological system, we studied the pharmacokinetics of camptothecin in mice. Elimination of camptothecin from mice blood was triphasic and followed first-order kinetics. The half-life of camptothecin in mouse blood was 25.7 min. Our studies indicate that HPLC with fluorescence detection for the determination of camptothecin in different media is a simple, rapid, sensitive and reproducible method.  相似文献   

2.
A selective and highly sensitive liquid chromatographic method for the determination of ganciclovir (anti-virus drug) in human serum was described. After ganciclovir and acyclovir (internal standard; IS) were extracted with solid-phase extraction cartridge from serum, they were converted into fluorescent derivatives by reaction with phenylglyoxal in a phosphate buffer (pH 5.8) at 20 degrees C for 30 min. The derivatives were separated by reversed-phase column with a mixture of acetonitrile-1 mM phosphate buffer (pH 6.2) (18:82, v/v), and were then detected spectrofluorometrically at 512 nm with excitation at 365 nm. Extraction recoveries were 87.0-91.6% for ganciclovir and 86.8-92.3% for IS. The detection limit for ganciclovir spiked to serum was 5 ng ml-1 serum (306 fmol on column) at a signal-to-noise ratio of three. The accuracy and precision of this method were 7.6% and 5.0% even at low concentration (20 ng ml-1). The within- and between-day variations are lower than 7.6% and 8.1%, respectively.  相似文献   

3.
A novel flow injection method with resonance light scattering detection was developed for the determination of total protein concentrations. This method is based on the enhancement of RLS signals from Methyl Blue (MB) by protein. The enhanced RLS intensities at 333 nm, in a pH 4.1 acidic aqueous solution, were proportional to the protein concentration over the range 2.0-37.3 and 1.0-36.0 microg ml-1 for human serum albumin (HSA) and bovine serum albumin (BSA), respectively. The corresponding limits of detection (3sigma) of 45 ng ml-1 for HSA and 80 ng ml-1 for BSA were attained. The method was successfully applied to the quantification of total proteins in human serum samples, the maximum relative error is less than 1% and the recovery is between 98% and 102%. The sample throughput was 60 h-1.  相似文献   

4.
A sensitive high-performance liquid chromatographic method with fluorescence detection for determining methamphetamine and its major metabolite, amphetamine, in abusers' hair segments was developed. Methamphetamine and amphetamine in hair samples collected from addicts were extracted into acidified methanol, derivatized with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride, separated isocratically on an ODS column using TRIS-HCl buffer (0.1 mol dm-3, pH 7.0)-methanol (30 + 70 v/v) as the mobile phase and the derivatives were detected fluorimetrically at 440 nm (lambda ex 330 nm). Calibration curves obtained by using control human hair spiked with standard solutions were linear (r > or = 0.999) up to at least 676.1 ng mg-1 for amphetamine and 746.1 ng mg-1 for methamphetamine. The detection limits at a signal-to-noise ratio of 3 were 51.4 and 74.6 pg mg-1 hair for amphetamine and methamphetamine, respectively. Using control hair spiked with standard solutions, the intra- and inter-day relative standard deviations (n = 5) were < or = 8.6% for both the target compounds. The method was successfully applied to the segmental analyses of methamphetamine abusers' hair samples.  相似文献   

5.
Column-switching techniques for high-performance liquid chromatography of two acidic drugs, ibuprofen and mefenamic acid, in human serum with short-wavelength ultraviolet detection are described. The method involved extraction of the analyte from acidified serum followed by the chromatographic analysis using column switching. Three ODS columns were used each with different mobile phase, utilizing the difference of ion-pair formation or of ionization caused by pH change. The method offered high sensitivity and selectivity, with short-wavelength ultraviolet detection at 221 nm for ibuprofen and at 219 nm for mefenamic acid. The detection limits were 0.5 ng/ml (2.4 pmol/ml) for ibuprofen and 0.1 ng/ml (0.4 pmol/ml) for mefenamic acid using 1 ml of serum, both at a signal-to-noise ratio of 3. With some modifications, the principle of the method would be applicable to other acidic compounds in biological fluids.  相似文献   

6.
A simple and sensitive high-performance liquid chromatography method is developed for the determination of orbifloxacin (ORB) in rabbit plasma. Sample preparations are carried out by adding phosphate buffer (pH 7.4, 0.1 M) and extracting with trichloromethane. ORB and the internal standard, norfloxacin (NOR), are separated on a reversed-phase column using an aqueous phosphate buffer-acetonitrile (80:20, v/v) mobile phase. The concentrations of ORB and NOR eluting from the column with retention times of 2.16 and 3.09 min, respectively, are monitored by fluorescence detection at 338 (excitation) and 425 nm (emission). The method is shown to be linear from 4 to 1500 ng/mL (regression coefficient r2 = 0.999). The quantitation and detection limits are 4 and 9 ng/mL, respectively. Mean recovery is determined as 92% by the analysis of plasma standards containing 150, 750, and 1500 ng/mL. Inter- and intra-assay precisions were 4 and 3%, respectively.  相似文献   

7.
Nifedipine (Nif) is widely used in treating cardiovascular disorders (especially hypertension) and for inhibiting preterm labor. A fully validated selective high-performance liquid chromatographic method with diode array detection, using solid-phase extraction, was developed for the determination of Nif in human serum. To assess specificity, Nif and its degradation products were separated on a Purospher RP-18 (5 microm, 125 x 4 mm) column plus a LiChrospher 100 RP-18 (5 microm, 4 x 4 mm) precolumn with a mobile phase of methanol-10 mM aqueous trifluoroacetic acid, pH 7.3 (57 + 43, v/v); chromatographic separation was followed by UV detection at 238 nm. For toxicological analysis, Nif in the presence of other calcium-channel antagonist drugs was identified under optimum chromatographic conditions. The calibration graph was constructed over the concentration range of 12.5-400 ng/mL in serum with good correlation (r = 0.9956). This method was not subject to interference by other plasma components and was successfully applied to the assay of Nif in spiked human serum and in serum of women in preterm labor after sublingual administration of 30 mg Nif per day divided into 3 equal doses. The mean recovery based on the ratio of the slopes of serum and mobile phase standard curves was 96.5%. The detection and quantification limits of the drug in spiked human serum were found to be 6 and 17.5 ng/mL, respectively. Validation of the method demonstrated good intraday and interday precision, which ranged from 2.18 to 6.67% and from 6.52 to 11.93%, respectively.  相似文献   

8.
Ocaña JA  Barragán FJ  Callejón M 《The Analyst》2000,125(12):2322-2325
A spectrofluorimetric method to determine the antibiotic moxifloxacin is proposed and was applied to pharmaceuticals, human urine and serum. The fluorimetric method allows the determination of 30-300 ng mL-1 moxifloxacin in aqueous solution containing phosphoric acid-phosphate buffer (pH 8.3) with lambda exc = 287 nm and lambda em = 465 nm. Detection and quantification limits were 10 and 30 ng mL-1, respectively, with a relative standard deviation (n = 10) of 2%. This method was applied to the determination of moxifloxacin in three Spanish commercial pharmaceutical formulations. Another variant of the method in micellar medium allows the direct measurement of moxifloxacin in human serum and urine by standard additions. The enhanced fluorescence of moxifloxacin in 8 mM sodium dodecyl sulfate (SDS) solution at pH 4.0 (acetic acid-acetate buffer) for lambda exc = 294 nm and lambda em = 503 nm shows the same linear range as the aqueous method with a 25% lower slope (with detection and quantification limits of 15 and 60 ng mL-1, respectively, and a relative standard deviation of 1.3%), but permits the background fluorescence for urine and serum blanks to be minimized. Hence, sufficient sensitivity is reached to determine therapeutic concentrations of the drug in urine (average recovery 102 +/- 2%) and serum (average recovery 105 +/- 2%) samples.  相似文献   

9.
6-Oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl)fluorescein (SAMF), a new fluorescein-based amine-reactive fluorescent probe was well designed, synthesized and used as a pre-column derivatizing reagent for the determination of aliphatic amines in HPLC. It exhibited relatively pH-independent fluorescence (pH 4-9) and excellent photostability. The derivatization was performed at room temperature in 6min. On a C18 column, the derivatives of SAMF with eight aliphatic amines were baseline separated in 28 min with a mobile phase of methanol-water (57:43, v/v) containing 10 mmol l(-1) pH 5.0, H3Cit3-NaOH buffer. With fluorescent detection at lambda(ex)/lambda(em) = 484/516 nm, the detection limit could reach 2-320 fmol (signal-to-noise = 3), which was equivalent to or better than the detection limits obtained from other analytical methods of aliphatic amines. The proposed method has been applied to the determination of the aliphatic amines in environmental and food samples such as lake water, red wine, white wine, and cheese with satisfying recoveries varying from 95 to 106%.  相似文献   

10.
在不加任何催化剂条件下, 2-(12-苯并吖啶酮)-乙酸(BAAA)与N,N′-羰基双咪唑(CDI)缩合生成新型荧光探针5-羰基咪唑苯并吖啶酮(IEBA). IEBA在DMF溶剂中与胺类化合物形成的酰胺类衍生物不仅可发出强烈的荧光, 还具有较高的质谱离子化能力. 该衍生物在乙腈和甲醇-水溶液中的百分离子化δ值分别在0~57.32% 和0~62.14%范围内. 最大激发和发射波长λex/λem=272 nm/505 nm. 12种胺类衍生物的荧光检出限范围为0.15~0.50 ng/mL, 在线APCI-MS检出限范围为1.43~8.51 ng/mL.  相似文献   

11.
A simple, rapid and sensitive fluorescence high performance liquid chromatographic method was developed to determine propranolol concentration in the small volume of rat plasma without the solvent extraction step using pronethanol as the internal standard. The analysis was accomplished using a 5 microm CAPCELL PAK analytical cyano column at room temperature and a mobile phase consisted of 1% aqueous acetic acid containing 0.2% triethylamine and acetonitrile (65:35, v/v; pH 3.8). The flow-rate was kept at 0.5 mL/min and column effluent was monitored with a fluorescence detector at an excitation wavelength of 230 nm and an emission wavelength of 340 nm. Retention times for pronethalol and propranolol were 8.5 min and 10.5 min, respectively. Linear regressions for the standard curves were linear in the range 2-800 ng/mL, giving correlation coefficients above 0.998. The detection limit was 1.34 ng/mL. No analytical interference was observed from endogenous components in rat plasma. This simple and sensitive assay method was feasibly applied to the pharmacokinetic study of propranolol after intravenous administration of 2 mg/kg of propranolol to normal and carbon tetrachloride-induced liver cirrhotic rats.  相似文献   

12.
A simple and sensitive HPLC-UV method was developed for the determination of paclitaxel (TXL) in human and rat blood samples. 4-Hydroxybenzoic acid n-hexyl ester was used as an internal standard. TXL was extracted by a liquid-liquid extraction with tert-butylmethyl ether. The disturbing peaks in the case of serum sample were removed by pre-extraction with hexane. The separation of TXL was achieved within 25 min using an ODS column with 50% acetonitrile aqueous solution as a mobile phase at a flow rate of 1.0 mL/min. The eluent was monitored at 230 nm, and the resulted retention times of TXL and IS were 11.2 and 20.4 min. The detection limits of TXL for human plasma, serum and rat plasma samples at a signal-to-noise ratio of 3 were 10, 9.5 and 7.5 ng/mL, respectively. The proposed methods were applicable to the determination of TXL in human patients' plasma ranging from 15 to 27 ng/mL. Furthermore, monitoring of the time course of TXL after its single administration to rat could be demonstrated.  相似文献   

13.
This paper describes a novel and sensitive pre-column derivatisation method for the detection and quantitation of beta-lactams and their biosynthetic precursors at trace levels in fermentation media. Filtered broths from fermentations of strains of Penicillium chrysogenum and Cephalosporium acremonium, after deproteination and centrifugation, were incubated with 9-fluorenylmethylchloroformate for 5 min at 20 degrees C in 0.2 M borate buffer at pH 7.7. Following two-fold pentane extraction of the reagent hydrolysis product, the aqueous layer was injected directly onto a C18 reversed-phase column, and products were detected spectrofluorimetrically with excitation and emission wavelengths of 260 and 313 nm, respectively. Detection limits of 0.01 and 0.05 micrograms ml-1 were achieved for both 6-aminopenicillanic acid (6-APA) and isopenicillin N in borate buffer and filtered fermentation broths, respectively, using a 10-microliter injection volume. A linear calibration for 6-APA in fermentation broth was obtained for a very wide concentration range (0.05-100 micrograms ml-1). Detection limits for solutions of cephalosporin C, deacetylcephalosporin C and deacetoxycephalosporin C in broth were all 0.25 micrograms ml-1. The detection limit for the beta-lactam precursor delta-(L-aminoadipyl)-L-alpha-cysteinyl-D-valine (ACV) dimer in borate buffer was 0.5 microgram ml-1. The cephalosporins and ACV dimer gave linear plots in the ranges 3-25 and 1-100 micrograms ml-1, respectively. Repeated analysis of 6-APA at a concentration of 10 micrograms ml-1 in filtered broth gave a mean peak area of 2.5.10(6) with a standard deviation of 2.6.10(5) using a 10-microliter injection volume. Ampicillin spiked into deproteinated blood serum gave a linear calibration in the concentration range 2-100 micrograms ml-1.  相似文献   

14.
A high-performance liquid chromatographic assay has been developed for the determination of nizatidine, a new histamine H2-receptor antagonist, and two of its main metabolites, N-desmethylnizatidine and nizatidine sulphoxide. Drugs were extracted with chloroform-2-propanol (90:10, v/v) from alkalinized samples of serum, using ranitidine as an internal standard. After evaporation of the extraction solvent, the residue was removed and analysed on a LiChrosorb Si60 5-microns column with a mobile phase of acetonitrile-methanol-water-ammonia solution (1000:200:20:5, v/v). The compounds were detected at 320 nm. The lower detection limits were 6-18 ng/ml at a signal-to-noise ratio of 3. This method is simple and specific, and the single-step extraction makes it rapid. It is the first high-performance liquid chromatographic assay to be described for the determination of nizatidine metabolites.  相似文献   

15.
Ning  Shujing  You  Jinmao  Sun  Zhiwei  Zhang  Shijuan  Ji  Zhongyin 《Chromatographia》2012,75(19):1107-1116

A simple and sensitive method for the determination of free aliphatic amines using 10-phenyl-acridone-2-sulfonyl chloride (PASC) as a labeling reagent by high-performance liquid chromatography with fluorescence detection and online mass spectrometry identification (HPLC-FLD-MS) has been developed. Derivatization conditions including reagent concentration, buffer pH, reaction time and temperature were optimized. PASC reacted with aliphatic amines at 50 °C for 4 min in aqueous acetonitrile (ACN) in the presence of sodiumtetraborate–NaOH buffer (0.10 mol L−1, pH 9.0) to give high yields of PASC-amine derivatives. Derivatives exhibited intense fluorescence with an excitation maximum at λex 265 nm and an emission maximum at λem 418 nm. The separation of derivatives was performed by a reversed-phase Hypersil BDS C8 column in combination with a gradient elution. The identification of derivatives was carried out by online post-column mass spectrometry with atmospheric pressure chemical ionization (APCI) source in positive-ion detection mode. Excellent linear responses were observed with the correlation coefficients of larger than 0.9997, and detection limits (at a signal-to-noise of 3:1) were from 3.0 to 24.3 fmol. Comparing with 10-ethyl-acridine-2-sulfonyl chloride (EASC), PASC exhibited more intense fluorescence and ultraviolet absorbance. The proposed method is sensitive and reproducible for the determination of aliphatic amines from water and soil samples.

  相似文献   

16.
A new method for simultaneous determination of alkoxyethanols (2-methoxyethanol, 2-ethoxyethanol, 2-isopropoxyethanol, and 2-butoxyethanol) by high-performance liquid chromatography (HPLC) with fluorescence detection has been developed. The alkoxyethanols and an internal standard (2-phenoxyethanol) were derivatized by treatment with 1-anthroylnitrile to give the anthroyl esters. The esterification was completed in 30 min in the presence of quinuclidine as base catalyst at room temperature. After stopping the reaction, an aliquot of the final solution was injected into the HPLC. The resulting anthroyl esters of the alkoxyethanols and the internal standard were separated on a C18 reversed-phase column with acetonitrile-water-acetic acid (65:35:0.1, v/v) as the mobile phase and detected fluorimetrically at excitation and emission wavelengths of 360 nm and 460 nm, respectively. The detection limits of the derivatives as alkoxyethanols at a signal-to-noise ratio of 3 were in the range of 1-3 pg per injection. The minimal amounts of alkoxyethanols derivatized in the reaction mixture for derivatization to determine the limits of detection were approximately 0.5 ng. This HPLC method was applied to the determination of some of alkoxyethanols in the air of the workplace where the thinner containing alkoxyethanols was used for painting.  相似文献   

17.
H Cai  C K Lim 《The Analyst》1998,123(11):2243-2245
High-performance liquid chromatographic (HPLC), capillary electrophoretic (CE) and direct spectrofluorimetric methods for the determination of temoporfin-poly(ethylene glycol) 2000 conjugate (m-THPC-PEG 2000) in plasma are described and compared. m-THPC-PEG 2000 in plasma was quantitatively extracted (recovery 101-107%) with CH3OH-DMSO (4 + 1 v/v). The supernatant after centrifugation was used for HPLC, CE or direct spectrofluorimetric determination. The major drawback of the HPLC method was that it gave a broad and split peak even under gradient elution conditions, resulting in difficulty in detection and quantification. This is because m-THPC-PEG 2000 consists of a group of compounds with an average molecular mass of approximately 8680 Da owing to the wide molecular mass distribution of PEG 2000 used in the synthesis of the drug. m-THPC-PEG 2000 gave a single and relatively sharp peak when separated by CE with sodium tetraborate buffer (pH 9.45) in the presence of sodium dodecyl sulfate as the running buffer. However, this method lacks the necessary sensitivity for detecting the drug in plasma extract because of the limited sample volume that can be injected. Direct spectrofluorimetry is the method of choice because of its simplicity, specificity and sensitivity. Using an excitation wavelength of 423 nm and the specific emission maximum of 657 nm, the fluorescence intensity could be sensitively measured. The calibration curve constructed by plotting fluorescence intensity against concentration was linear within the range 1.32-1056 ng ml-1. The detection limit (S/N = 3) was 1.32 ng ml-1 and the limit of quantification (S/N = 10) was 2.24 ng ml-1. The precision and reproducibility were assessed by repeated analysis (n = 24) of spiked plasma samples at 350.8 and 699.3 ng ml-1. The RSD was 4.5% and 1.6%, respectively.  相似文献   

18.
Zhang W  Xu H  Wu S  Chen X  Hu Z 《The Analyst》2001,126(4):513-517
For the first time, Crystal Violet (CV) was used to determine nucleic acid concentrations using the resonance light-scattering (RLS) technique. Based on the enhancement of the RLS of CV by nucleic acids, a new quantitative determination method for nucleic acids in aqueous solutions has been developed. At pH 5.03 and ionic strength 0.005 mol kg-1, the interaction of CV with nucleic acids results in three characteristic RLS peaks at 344.0, 483.0 and 666.0 nm. With 4.0 x 10(-5) mol l-1 of CV, linear relationships were found between the enhanced intensity of RLS at 666.0 nm and the concentration of nucleic acids in the range 0-2.5 micrograms ml-1 for herring sperm DNA, 0-4.0 micrograms ml-1 for calf thymus DNA and 0-4.5 micrograms ml-1 for yeast RNA. The limits of determination were 13.8 ng ml-1 for herring sperm DNA, 36.8 ng ml-1 for calf thymus DNA and 69.0 ng ml-1 for yeast RNA. The assay is convenient, rapid, inexpensive and simple.  相似文献   

19.
A simple, rapid and highly sensitive reversed-phase liquid chromatographic method has been developed for the determination of sialic acids in human serum. The sialic acids, released by hydrolysis of serum, are converted in borate buffer with malononitrile to highly fluorescent compounds. The reaction mixture is separated isocratically within 5 min using an octadecyl-bonded silica column and a mobile phase of methanol and ammonium acetate buffer (15:85, v/v; pH 5.5). Measurement of the fluorescence intensity of the reaction mixture at 434 nm with irradiation at 357 nm allowed determination of 30-1000 ng/ml of sialic acids with high reproducibility. The limit of detection was 2 ng/ml. Intra-day and inter-day coefficients of variation for assaying 300 ng/ml N-acetylneuraminic acid (NANA) were 1.5% (n = 9) and 2.6% (n = 7), respectively. The recoveries of NANA were 98.5-101.1% for serum. The method has been used for clinical determinations.  相似文献   

20.
A new fluorescein-based fluorescent derivatizating reagent, 6-oxy-(acetyl piperazine) fluorescein (APF), has been designed, synthesized and developed for carboxylic acid labeling. It was used as a pre-column derivatizing reagent for the determination of seven free fatty acids (lauric acid, myristic acid, arachidonic acid, linoleic acid, palmitic acid, oleic acid, and stearic acid) with high-performance liquid chromatography (HPLC). The derivatization reaction of APF with seven fatty acids was completed at 60 degrees C for 1 h using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) as the condensing reagent. On a C18 column, the derivatives of APF with seven free fatty acids could be separated completely in 22 min using a mobile phase of methanol-water (88:12, v/v) containing 7 mmol L(-1) pH 6.5 Na2HPO4-H3Cit3 buffer with fluorescence detection at lambdaex/lambdaem=467/512 nm. The detection limits could reach 0.1-6.4 nmol L(-1) (signal-to-noise=3). This reagent was applied to the determination of the free fatty acids in human serum samples with satisfying recovery efficiencies varying from 93 to 105%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号