首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.  相似文献   

2.
Abstract

A high-performance liquid chromatographic method for the analyses of ciprofloxacin (BAY o 9867) (1-cyclopropyl-6-fluoro-1,4-dihydro-4-oxo-7-(1-piperazinyl)-3-quinoline carboxylic acid hydrochloride) in human serum, plasma and urine samples is described. Diluted serum, plasma, and urine samples are injected onto a RP-18 column without prior extraction or clean-up procedure. Ciprofloxacin is separated from the ballast by an eluent consisting of an 0.025M H3PO4 solution adjusted to pH=3 with tetrabutylammonium hydroxide and acetonitrile.

Ciprofloxacin is detected fluorimetrically giving a detection limit of 8ng/ml in plasma and serum and of 50ng/ml in urine. A statistical evaluation of the assay showed acceptable accuracy and precision for 10 to 500ng of BAY o 9867 per ml in serum and plasma and for 50ng to 600ng of BAY o 9867 per ml of diluted urine specimens. This method was used to monitor the concentrations of BAY o 9867 in serum, plasma and urine of volunteers after oral administration of ciprofloxacin.  相似文献   

3.
A high-performance liquid chromatographic method for the measurement of bumetanide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol-water-glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5-2000 ng/ml.  相似文献   

4.
A sensitive method has been developed for the detection and quantitative determination of thiodiglycol in blood, plasma and urine. Samples were extracted from Clin Elut columns and cleaned up on C18 Sep-Pak cartridges (blood, plasma) or Florisil Sep-Pak cartridges (urine). Tetradeuterothiodiglycol was added to the sample prior to extraction as internal standard. Thiodiglycol was converted to its bis-(pentafluorobenzoate) derivative and analysed by capillary gas chromatography-electron-capture negative-ion chemical ionisation mass spectrometry using selected ion monitoring. Levels of thiodiglycol down to 1 ng/ml (1 ppb) could be detected in 1-ml spiked blood and urine samples; calibration curves were linear over the range 5- or 10-100 ng/ml. Blood and urine samples from a number of control subjects were analysed for background levels of thiodiglycol. Concentrations up to 16 ng/ml were found in blood, but urine levels were below 1 ng/ml.  相似文献   

5.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

6.
In oncology, particularly in pediatric malignancies, high doses (5-10 g/m2) of the oxazaphosphorine ifosfamide play an important role in the treatment of sarcomas. Pharmacokinetic data of ifosfamide and its metabolites in these cases are scanty. Considering the special demands of the determination of ifosfamide in plasma of young children, a very sensitive capillary gas chromatographic method, requiring only 50 microliters of plasma, has been developed. This bioanalysis of ifosfamide shows good linearity and accuracy in the concentration range 10 ng to 100 micrograms per ml of plasma and 25 ng to 1 mg per ml of urine. The absolute limits of detection in plasma and urine are 2 ng/ml and 5 ng/ml, respectively. The stability of various solutions of ifosfamide and trofosfamide was tested and proved to be satisfactory, except for ifosfamide in plasma and urine kept in the refrigerator. The validity of the method for pharmacokinetic purposes is shown in the case of one patient.  相似文献   

7.
A sensitive and selective high-performance liquid chromatographic method for determination of intact glipizide in human plasma or urine has been developed. The plasma and urine samples were acid-buffered, before tolbutamide was added as internal standard. The samples were extracted with benzene, and the organic layer was evaporated to dryness. The residue was dissolved in equilibrated mobile phase (acetonitrile-0.01 M phosphate buffer pH 3.5, 35:65), and an aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column. Quantitation was achieved by monitoring the ultraviolet absorbance at 275 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents were observed. The utility of the assay was demonstrated by determining glipizide in samples from a diabetic subject receiving a therapeutic dose of 5 mg of the drug.  相似文献   

8.
The metabolic oxidation of one of the chloroethyl groups of the antitumour drug ifosfamide leads to the formation of the inactive metabolites 2- and 3-dechloroethylifosfamide together with the neurotoxic metabolite chloroacetaldehyde. A very sensitive capillary gas chromatographic method, requiring only 50 microliters of plasma or urine, has been developed to measure the amounts of the drug and the two inactive metabolites in a single run. Calibration curves were linear (r > 0.999) in the concentration ranges from 50 ng/ml to 100 micrograms/ml in plasma and from 100 ng/ml to 1 mg/ml in urine.  相似文献   

9.
A relatively simple, sensitive and rapid high-performance liquid chromatographic method is described for measuring the anticancer drug 5-fluorouracil (5-FU) in human plasma and urine. The procedure includes liquid-liquid extraction using ethyl acetate-methanol (95:5) and preparative column chromatography to separate 5-FU from constituents normally occurring in these biological samples. The columns contained a specially modified form of diatomaceous earth, which requires no pre-conditioning washes. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70 mm x 4.6 mm I.D.) with a mobile phase of water-methanol (95:5) and ultraviolet detection (268 nm). The overall recovery from plasma and urine was 91 and 94%, respectively, at the concentration of 50 ng/ml. The determination limit of the assay for 5-FU was 10 ng/ml of plasma and urine. Concentrations of 5-FU between 10 and 500 ng/ml were measured in plasma and urine with a relative standard deviation of 6.8%. In order to evaluate the procedure, plasma and urine samples from three patients treated with 5-FU by continuous intravenous perfusion, were investigated.  相似文献   

10.
Sensitive and selective methods have been developed for quantitation of the novel anticonvulsant remacemide in rat and dog plasma and urine. The methods employed liquid-liquid extraction (urine) or ion-exchange solid-phase extraction (plasma), with an internal standard, followed by high-performance liquid chromatography with ultraviolet detection. The detection limit for both methods was 10 ng/ml. Overall accuracy was 0.00% for plasma and -1.4% for urine with a precision of 6.04 and 3.87% for plasma and urine, respectively. The standard curves were linear for both plasma and urine over a wide concentration range (9.96-2490 ng/ml). The plasma method was also applied to measurement of in vitro plasma protein binding of remacemide in rat, dog and human plasma.  相似文献   

11.
A simple and sensitive high-performance liquid chromatographic assay was developed for the quantitative determination of major erythromycin components and their potential metabolites or degradation products in plasma and urine. An ether extract of alkalized plasma sample was chromatographed on a reversed-phase column and the components in the column effluent were monitored by an electrochemical detector. The recovery of the drug from extraction was virtually 100%. The detection limits for erythromycin A in plasma were 5-10 ng/ml and 30 ng/ml using 1 and 0.2 ml of sample, respectively. For urine samples, a simple one-step deproteinization with two volumes of acetonitrile was satisfactory for analysis. The method has been evaluated in plasma and urine from dogs receiving oral or intravenous erythromycin A. The standard curves for potential metabolites or degradation products were not constructed due to the lack of sufficient samples.  相似文献   

12.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (CipralanTM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile-phosphate buffer (0.015 mol/l, pH 6.0) (80:20). A 10-microns ion-exchange (sulfonate) column was used with acetonitrile-phosphate buffer (0.015 mol/l, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard. The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10-1000 ng/ml and 50-5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   

13.
A single high-performance liquid chromatographic (HPLC) assay for the quantitative determination of dilevalol, the R,R isomer of labetalol, was developed for both plasma and urine. A significantly improved limit of detection for dilevalol in plasma was accomplished by extensive modification of an HPLC assay originally developed in our laboratory for labetalol. This simplified method is readily adaptable to urine and represents the first reported HPLC assay for the quantitative determination of dilevalol in this biofluid. Drug was recovered from plasma or urine by partition into diethyl ether under mildly alkaline conditions and back-extraction into dilute acid. Reversed-phase separation of dilevalol and the internal standard was accomplished on a 150 X 4.1 mm column commercially packed with a spherical (5 micron) macroporous copolymer (PRP-1). No interferences were observed in extracts obtained from drug-free plasma or urine. Selectivity for dilevalol in the presence of other beta-blockers was established. This method demonstrated a linear detector response to concentrations of unchanged drug typically observed in urine and plasma following once-a-day treatment with dilevalol hydrochloride (100-800 mg). The lowest limit of reliable quantitation was established at 1 ng/ml in plasma. The intra-assay precision (coefficient of variation) remained less than 6% at all concentrations evaluated from 1 to 800 ng/ml. In urine, the lowest limit of quantitation was validated to 20 ng/ml where the intra-assay precision (coefficient of variation) for unchanged drug was less than 4% at all concentrations evaluated up to 400 ng/ml. This method is suitable for routine quantitation of unchanged drug in human plasma and urine following the administration of therapeutically effective doses of dilevalol hydrochloride.  相似文献   

14.
A rapid, sensitive and robust assay procedure using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) for the determination of famotidine in human plasma and urine is described. Famotidine and the internal standard were isolated from plasma samples by cation-exchange solid-phase extraction with benzenesulfonic acid (SCX) cartridges. The urine assay used direct injection of a diluted urine sample. The chromatographic separation was accomplished by using a BDS Hypersil silica column with a mobile phase of acetonitrile-water containing trifluoroacetic acid. The MS/MS detection of the analytes was set in the positive ionization mode using electrospray ionization for sample introduction. The analyte and internal standard precursor-product ion combinations were monitored in the multiple-reaction monitoring mode. Assay calibration curves were linear in the concentration range 0.5--500 ng ml(-1) and 0.05--50 microg ml(-1) in plasma and urine, respectively. For the plasma assay, a 100 microl sample aliquot was subjected to extraction. To perform the urine assay, a 50 microl sample aliquot was used. The intra-day relative standard deviations at all concentration levels were <10%. The inter-day consistency was assessed by running quality control samples during each daily run. The limit of quantification was 0.5 ng ml(-1) in plasma and 0.05 microg ml(-1) in urine. The methods were utilized to support clinical pharmacokinetic studies in infants aged 0-12 months.  相似文献   

15.
A method is described for the extraction of a phosphonic acid angiotensin-converting enzyme inhibitor from either urine or plasma, and subsequent quantitation using high-performance liquid chromatographic (HPLC) analysis and post-column o-phthalaldehyde reagent derivatization. The compound cannot be quantitatively extracted from the body fluids, but use of a fluorinated internal standard allowed for the computation of accurate results. With the use of an internal standard, excellent precision, linearity, and recovery were obtained for analyte response in both urine and plasma. In urine a working range of 0.2-10 micrograms/ml was found, with a limit of detection of 0.1 micrograms/ml. For plasma the working range was found to be 2-500 ng/ml, and the limit of detection was established as 1 ng/ml. Due to the non-polar character of the analyte at low pH values, it was possible to use novel extraction (solid-phase C8 column) and HPLC [poly(styrenedivinyl benzene) HPLC column] conditions to separate and quantitate the compound from plasma and urine.  相似文献   

16.
A high-performance liquid chromatographic method for the determination of disodium dihydrogen(cycloheptylamino)methylene-bisphosphonate monohydrate (YM175) in plasma, urine and bone is described. Plasma obtained in high-dose animal studies is pretreated by Method A, a simple method using 1 ml of plasma, which is based on deproteinization of plasma followed by coprecipitation of the drug with calcium phosphate and removal of excess calcium ions by AG 50W-X8 resin. Plasma obtained in lower-dose clinical studies is treated by Method B, a more sensitive method using 10 ml of plasma, which is based on solid-phase extraction using a Sep-Pak C18 cartridge coupled with Method A. Urine and bone are treated similarly to Method B. The chromatographic system consists of a mobile phase at pH 11, an alkali-stable column and an electrochemical detector operating in the oxidation mode. The determination limit is 5 ng/ml for Method A and 0.5 ng/ml for Method B in plasma, 1 ng/ml in urine, and 25 ng/g in bone.  相似文献   

17.
A high-performance liquid chromatographic method was developed for the simultaneous determination of haloperidol and reduced haloperidol in human plasma, urine and rat tissue homogenates using bromperidol as an internal standard. The method involved extraction followed by injection of 50-80 microliters of the aqueous layer onto a C18 reversed-phase column. The mobile phase was 0.5 M phosphate buffer-acetonitrile-methanol (58:31:11, v/v/v) and the flow-rate was 0.6 ml/min. The column effluent was monitored by ultraviolet detection at 214 nm. The retention times for reduced haloperidol, haloperidol and bromperidol were 5.4, 7.2 and 8.4 min, respectively. The detection limits for haloperidol and reduced haloperidol in human plasma were both 0.5 ng/ml, and the corresponding values in human urine were both 5 ng/ml. The coefficients of variation of the assay were generally low (below 10.7%) for plasma, urine, blood and tissue homogenates. No interferences from endogenous substances or any drug tested were found.  相似文献   

18.
A high-performance liquid chromatographic (HPLC) method with electrochemical detection for the determination of oxilofrine [1-(4-hydroxyphenyl)-2-methylaminopropanol] in human plasma and urine (before and after cleavage of the metabolic conjugates) is described. Isolation from biological fluids is performed batchwise by weak acid cation exchange. Separation of plasma and urine components is achieved on a reversed-phase C18 column as an ion pair with heptanesulphonic acid. For amperometric detection the potential of the electrode was set at 0.95 V versus an Ag/AgCl reference electrode. The detection limit for oxilofrine in plasma is 1 ng/ml and in urine 12.5 ng/ml at a signal-to-noise ratio of 2.0 using 1.0 ml of plasma and 0.02 ml of urine. The method was compared with a gas chromatographic-mass spectrometric method and showed a good concordance for plasma (r = 0.996) and urine (r = 0.994). With the HPLC method it is also possible to determine related sympathomimetic drugs, e.g., etilefrine, norefenefrine or octopamine, after a slight modification of the mobile phase.  相似文献   

19.
A sensitive and selective method for the determination of the pyridinium metabolite (HPP+) derived from the antipsychotic drug haloperidol (HP) in brain tissue, plasma and urine using high-performance liquid chromatography with fluorescence detection is described. The HPP+ present in biological samples was extracted using a Sep-Pak C18 cartridge. Recoveries of HPP+ ranged from 78 to 90%. Final separation and quantitative estimations of HPP+ were achieved on a C18 reversed-phase column employing a mobile phase of acetonitrile-30 mM ammonium acetate (40:60, v/v) containing 10 mM triethylamine and adjusted to pH 3 with trifluoroacetic acid. The fluorescence detection utilized an excitation wavelength of 304 nm and an emission wavelength of 374 nm. Standard curves were linear in the range of 2.5-100 ng/ml for brain tissue homogenate and plasma samples and 10-500 ng/ml for urine samples. The detection limit of HPP+ was about 1 ng/ml in all biological samples. The concentrations of HPP+ in brain tissue, plasma and urine from HP-treated rats were determined using this method.  相似文献   

20.
A high-performance liquid chromatographic method has been developed which enables sensitive determination of captopril and its mixed disulphides in plasma and urine after oral administration of a new antihypertensive agent, 1-(D-3-acetylthio-2-methylpropanoyl)-L-prolyl-L-phenylalanine (DU-1219, I). Captopril is derivatized with a new reagent, N-(4-benzoylphenyl)maleimide and the derivative is extracted with chloroform and assayed using a liquid chromatograph equipped with an ultraviolet detector at 254 nm. Mixed disulphides of captopril with thiol compounds such as cysteine, glutathione and plasma proteins are reduced with tributylphosphine to form captopril, followed by derivatization with N-(4-benzoylphenyl)maleimide. Accurate determinations are possible over a concentration range of 10-500 ng/ml captopril in plasma, and 100-2500 ng/ml captopril in urine. The coefficients of variation of captopril in plasma (200 ng/ml) and urine (500 ng/ml) are 3.7% and 2.6%, respectively, and those of mixed disulphides of captopril are similar to those of captopril. Plasma levels and urinary excretion of captopril and its mixed disulphides in healthy volunteers following single oral administration of I (50 mg) have also been determined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号