首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The present study describes a new analytical approach for the detection and characterization of chemically reactive metabolites using glutathione ethyl ester (GSH-EE) as the trapping agent in combination with hybrid triple quadrupole linear ion trap mass spectrometry. Polarity switching was applied between a negative precursor ion (PI) survey scan and the positive enhanced product ion (EPI) scan. The negative PI scan step was carried out monitoring the anion at m/z 300, corresponding to deprotonated gamma-glutamyl-dehydroalanyl-glycine ethyl ester originating from the GSH-EE moiety. Samples resulting from incubations in the presence of GSH-EE were cleaned and concentrated by solid-phase extraction, followed by the PI-EPI analysis. Unambiguous identification of GSH-EE-trapped reactive metabolites was greatly facilitated by the unique survey scan of the anion at m/z 300, which achieved less background interference, in particular, from endogenous glutathione adducts present in human liver microsomes. Further structural characterization was achieved by analyzing positive MS(2) spectra that featured rich fragments without mass cutoff and were acquired in the same liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. The effectiveness and reliability of this approach was evaluated using a number of model compounds in human liver microsomal incubations, including acetaminophen, amodiaquine, carbamazepine, 4-ethylphenol, imipramine and ticlopidine. In addition, iminoquinone reactive metabolites of mianserin were trapped and characterized for the first time using this method. Compared to neutral loss (NL) scanning assays using GSH as the trapping agent, the results have demonstrated superior selectivity, sensitivity, and reliability of this current approach.  相似文献   

2.
Drugs can be metabolically activated to soft and hard electrophiles, which are readily trapped by glutathione (GSH) and cyanide (CN), respectively. These adducts are often detected and structurally characterized using separate tandem mass spectrometry methods. We describe a new method for simultaneous screening of GSH and CN adducts using precursor ion (PI) and neutral loss (NL) scans-dependent product ion spectral acquisition and data mining tools on an triple quadrupole linear ion trap mass spectrometry. GSH, potassium cyanide, and their stable isotope labeled analogues were incubated with liver microsomes and a test compound. Negative PI scan of m/z 272 for detection of GSH adducts and positive NL scans of 27 and 29 Da for detection of CN adducts were conducted as survey scans to trigger acquisition of enhanced resolution (ER) spectrum and subsequent enhanced product ion (EPI) spectrum. Post-acquisition data mining of EPI data set using NL filters of 129 and 27 Da was then performed to reveal the GSH adducts and CN adducts, respectively. Isotope patterns and EPI spectra of the detected adducts were utilized for identification of their molecular weights and structures. The effectiveness of this method was evaluated by analyzing reactive metabolites of nefazodone formed from rat liver microsomes. In addition to known GSH- and CN-trapped reactive metabolites, several new CN adducts of nefazodone were identified. The results suggested that current approach is highly effective in the analysis of both soft and hard reactive metabolites and can be used as a high-throughput method in drug discovery.  相似文献   

3.
A method using high performance liquid chromatography (HPLC) coupled with ion trap mass spectrometry (MS) for simultaneous quantification of multiple drugs and detection of their metabolites is described. The new approach offers a significant increase in analytical throughput and is illustrated with analysis of the in vitro metabolism of 19 alpha-1a receptor antagonists. The compounds were separated into four cassette groups by using a computer program as well as by manual examination. The samples from incubation with dog liver microsomes were pooled into the designed cassette groups and analyzed by HPLC/electrospray (ESI) ion trap MS in full-scan mode. The metabolic stability of the drugs was determined by comparing their signals after incubation for 0 and 60 min, respectively. The quantitative results from the cassette analysis procedure agreed well with those obtained from conventional discrete analysis. In addition, the technique allowed simultaneous detection of metabolites formed during the same incubation without having to reanalyze the samples. The metabolites were first characterized by nominal mass measurement of the corresponding protonated molecules. Subsequent multi-stage tandem mass spectrometry (MS(n)) on the ion trap instrument allowed confirmation of the detected metabolites.  相似文献   

4.
Reactive metabolites are believed to be one of the main reasons for unexpected drug‐induced toxicity issues, by forming covalent adducts with cell proteins or DNA. Due to their high reactivity and short lifespan they are not directly detected by traditional analytical methods, but are most traditionally analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) after chemical trapping with nucleophilic agents such as glutathione. Here, a simple but very efficient assay was built up for screening reactive drug metabolites, utilizing stable isotope labeled glutathione, potassium cyanide and semicarbazide as trapping agents and highly sensitive ultra‐performance liquid chromatography/time‐of‐flight mass spectrometry (UPLC/TOFMS) as an analytical tool. A group of twelve structurally different compounds was used as a test set, and a large number of trapped metabolites were detected for most of them, including many conjugates not reported previously. Glutathione‐trapped metabolites were detected for nine of the twelve test compounds, whereas cyanide‐trapped metabolites were found for eight and semicarbazide‐trapped for three test compounds. The high mass accuracy of TOFMS provided unambiguous identification of change in molecular formula by formation of a reactive metabolite. In addition, use of a mass defect filter was found to be a usable tool when mining the trapped conjugates from the acquired data. The approach was shown to provide superior detection sensitivity in comparison to traditional methods based on neutral loss or precursor ion scanning with a triple quadrupole mass spectrometer, and clearly more efficient detection and characterization of reactive drug metabolites with a simpler test setup. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
Stable-isotope trapping combined with mass spectrometry (MS) neutral loss scanning has recently been developed as a high-throughput method for the in vitro screening of major reactive metabolites. In fact, detection and identification of minor reactive metabolites are equally important since the minor metabolites, even though at low levels, may be highly reactive and also play an important role in drug-induced adverse reactions. In this study, 2-acetylthiophene, clozapine, troglitazone and 7-methylindole were selected as model compounds to further validate the advantages of this method for rapid detection and structural characterization of minor glutathione (GSH) adducts derived from reactive metabolites. The utility of the current method was clearly demonstrated by successful identification of novel reactive metabolites at low levels and also minor ones either masked by non-specific responses or co-eluted with other conjugates. In comparison with existing methods, this method is sensitive, efficient, and suitable for rapid screening and more complete profiling of reactive metabolites.  相似文献   

6.
Combining source collision-induced dissociation (CID) and tandem mass spectral acquisition in a pseudo-MS(3) experiment using a linear ion trap results in a highly selective and sensitive approach to identifying glycopeptide elution from a protein digest. The increased sensitivity is partially attributed to the nonselective nature of source CID, which allows simultaneous activation of all charge states and coeluting glycoforms generating greater ion abundance for the mass-to-charge (m/z) 204 and/or 366 oxonium ions. Unlike source CID alone, a pseudo-MS(3) approach adds selectivity while improving sensitivity by eliminating chemical noise during the tandem mass spectral acquisition of the oxonium ions in the linear ion trap. Performing the experiments in the hybrid linear ion trap/Fourier transform-ion cyclotron resonance (FT-ICR) enables subsequent high-resolution/high-mass accuracy full-scan mass spectra (MS) and parallel acquisition of MS/MS in the linear ion trap to be completed in 2 s directly following the pseudo-MS(3) scan to collate identification and characterization of glycopeptides in one experimental scan cycle. Analysis of bovine fetuin digest using the combined pseudo-MS(3), high-resolution MS, and data-dependent MS/MS events resulted in identification of four N-linked and two O-linked glycopeptides without enzymatic cleavage of the sugar moiety or release of the sialic acids before analysis. In addition, over 95% of the total protein sequence was identified in one analytical run.  相似文献   

7.
Metabolic activation of drug candidates to electrophilic reactive metabolites that can covalently modify cellular macromolecules may result in acute and/or idiosyncratic immune system-mediated toxicities in humans. This presents a significant potential liability for the future development of these compounds as safe therapeutic agents. We present here an example of an approach where sites of metabolic activation within a new drug candidate series were rapidly identified using online liquid chromatography/multi-stage mass spectrometry on an ion trap mass spectrometer. This was accomplished by trapping the reactive intermediates formed upon incubation of compounds with rat and human liver microsomes as their corresponding glutathione conjugates and mass spectral characterization of these thiol adducts. Based on the structures of the GSH adducts identified, potential sites and mechanisms of bioactivation within the chemical structure were proposed. These metabolism studies were interfaced with iterative structural modifications of the chemical series in order to block these bioactivation sites within the molecule. This strategy led to a significant reduction in the propensity of the compounds to undergo metabolic activation as evidenced by reductions in the irreversible binding of radioactivity to liver microsomal material upon incubation of tritium-labeled compounds with this in vitro system. With the efficiency and throughput achievable with such an approach, it appears feasible to identify and address the metabolic activation potential of new drug leads during routine metabolite identification studies in an early drug discovery setting.  相似文献   

8.
Drug bioactivation leading to the formation of reactive species capable of covalent binding to proteins represents an important cause of drug‐induced toxicity. Reactive metabolite detection using in vitro microsomal incubations is a crucial step in assessing potential toxicity of pharmaceutical compounds. The most common method for screening the formation of these unstable, electrophilic species is by trapping them with glutathione (GSH) followed by liquid chromatography/mass spectrometry (LC/MS) analysis. The present work describes the use of a brominated analog of glutathione, N‐(2‐bromocarbobenzyloxy)‐GSH (GSH‐Br), for the in vitro screening of reactive metabolites by LC/MS. This novel trapping agent was tested with four drug compounds known to form reactive metabolites, acetaminophen, fipexide, trimethoprim and clozapine. In vitro rat microsomal incubations were performed with GSH and GSH‐Br for each drug with subsequent analysis by liquid chromatography/high‐resolution mass spectrometry on an electrospray time‐of‐flight (ESI‐TOF) instrument. A generic LC/MS method was used for data acquisition, followed by drug‐specific processing of accurate mass data based on mass defect filtering and isotope pattern matching. GSH and GSH‐Br incubations were compared to control samples using differential analysis (Mass Profiler) software to identify adducts formed via the formation of reactive metabolites. In all four cases, GSH‐Br yielded improved results, with a decreased false positive rate, increased sensitivity and new adducts being identified in contrast to GSH alone. The combination of using this novel trapping agent with powerful processing routines for filtering accurate mass data and differential analysis represents a very reliable method for the identification of reactive metabolites formed in microsomal incubations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
A new strategy using a hybrid linear ion trap/Orbitrap mass spectrometer and multiple post-acquisition data mining techniques was evaluated and applied to the detection and characterization of in vitro metabolites of indinavir. Accurate-mass, full-scan MS and MS/MS data sets were acquired with a generic data-dependent method and processed with extracted-ion chromatography (EIC), mass-defect filter (MDF), product-ion filter (PIF), and neutral-loss filter (NLF) techniques. The high-resolution EIC process was shown to be highly effective in the detection of common metabolites with predicted molecular weights. The MDF process, which searched for metabolites based on the similarity of mass defects of metabolites to those of indinavir and its core substructures, was able to find uncommon metabolites not detected by the EIC processing. The high-resolution PIF and NLF processes selectively detected metabolites that underwent fragmentation pathways similar to those of indinavir or its known metabolites. As a result, a total of 15 metabolites including two new indinavir metabolites were detected and characterized in a rat liver S9 incubation sample. Overall, these data mining techniques, which employed distinct metabolite search mechanisms, were complementary and effective in detecting both common and uncommon metabolites. In summary, the results demonstrated that this analytical strategy enables the high-throughput acquisition of accurate-mass LC/MS data sets, comprehensive search of a variety of metabolites through the post-acquisition processes, and effective structural characterization based on elemental compositions of metabolite molecules and their product ions.  相似文献   

10.
In the present study, a method for the analysis of reactive metabolites via liquid chromatography (LC) with inductively coupled plasma–mass spectrometry (MS) was developed. A ferrocenyl-modified glutathione (GSH) reagent, consisting of GSH and succinimidyl-3-ferrocenylpropionate, was synthesized. Derivatization of the tripeptide was performed at the N-terminus, leaving the nucleophilic thiol group vacant for the attack of electrophilic compounds. The potential of ferrocenylpropionate (FP)-GSH as a trapping agent for reactive metabolites was investigated using an electrochemical flow-through cell for metabolism simulation coupled online to a LC system with electrospray ionization mass spectrometric detection. The pharmaceuticals amodiaquine, an antimalarial agent, and clozapine, an antipsychotic compound, served as model substances. By proving the successful adduct formation between the reactive metabolite and ferrocene-labeled GSH, it could be shown that FP-GSH is an effective trapping agent which eases routine reversed-phase LC analyses. In contrast to GSH, which is usually used for the conjugation of reactive metabolites and where the resulting adducts often show no or only very little retention, FP-GSH facilitates the detection of the corresponding metabolite adducts due to higher retention times.  相似文献   

11.
The presence of pharmaceuticals in drinking water is an emerging environmental concern. In most environmental testing laboratories, LC-MS/MS assays based on selected reaction monitoring are used as part of a battery of tests used to assure water quality. Although LC-MS/MS continues to be the best tool for detecting pharmaceuticals in water, the combined use of hybrid high-resolution mass spectrometry (HRMS) and ultrahigh pressure liquid chromatography (UHPLC) is starting to become a practical tool to study emerging environmental contaminants. The hybrid LTQ-orbitrap mass spectrometer is suitable for integrated quantitative and qualitative bioanalysis because of the following reasons: (1) the ability to collect full-scan HRMS spectra with scan speeds suitable for UHPLC separations, (2) routine measurement of mass with less than 5 ppm mass accuracy, (3) high mass resolving power, and (4) ability to perform on-the-fly polarity switching in the linear ion trap (LTQ). In the present work, we provide data demonstrating the application of UHPLC-LTQ-orbitrap for the detection, characterization and quantification of pharmaceuticals and their metabolites in drinking water.  相似文献   

12.
The application of sulphur-specific detection via ultra-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (UPLC/ICPMS) to detect and quantify the glutathione (GSH)-adducts produced via the in vitro formation of reactive metabolites is demonstrated. The adducts were formed in human liver microsomes supplemented with unlabelled GSH for clozapine. The calculation of adduct concentration was performed via comparison of the peak areas to calibration curves constructed from omeprazole, a sulphur-containing compound over the range of 0.156 to 15.62 μM of sulphur with a detection limit of 1.02 ng of sulphur on-column. Identification of the adducts was performed using conventional UPLC/time-of-flight (TOF)-MS with the calculation of clozapine intrinsic clearance carried out by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). The use of ICPMS in this way appears to offer a novel, rapid and sensitive means of determining the quantity of GSH conjugates with the combined adducts producing 0.9 μM of reactive metabolite out of a total of 3.5 μM of metabolites. The GSH adduct therefore represents 26% of this total produced as a result of the metabolism of drug to reactive species.  相似文献   

13.
A need still exists for a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method that can detect broad classes of glutathione (GSH) conjugates and provide characterization of their structures. We now describe the development of a method that multiplexes high-resolution accurate mass analysis with isotope pattern triggered data-dependent product ion scans, for simultaneous detection and structural elucidation of GSH conjugates within a single analysis using a LTQ/Orbitrap. This method was initially developed to detect GSH conjugates generated from incubating 10 microM test compound with pooled human liver microsomes fortified with NADPH-regenerating system and a 2:1 ratio of 5 mM glutathione and [(13)C(2) (15)N-Gly]glutathione. The GSH conjugates were detected by isotope search of mass defect filtered and control subtracted full scan accurate MS data using MetWorks software. This was followed by elucidation of reactive intermediate structures using chemical formulae for both protonated molecules and their product ions from accurate masses in a single analysis. The mass accuracies measured for the precursor and product ions by the Orbitrap were <2 ppm in external mass calibration mode. Successful detection and characterization of GSH conjugates of acetaminophen, tienilic acid, clozapine, ticlopidine and mifepristone validated this method. In each case, the detected GSH conjugates were within the top five hits by isotope search. This method also has a broader detection capability since it is independent of the collision-induced dissociation behavior of the GSH conjugates. Furthermore, this method is amenable to a broad class of reactive intermediate trapping agents as exemplified by the simultaneous detection and structural elucidation of the cyano-N-methylene iminium ion conjugates of verapamil and its O-desmethyl metabolites, which we report for the first time. In addition to the chemically tagged reactive intermediates, this method also provides information on stable metabolites from the full scan accurate MS data.  相似文献   

14.
Capillary liquid chromatography (LC) using a 320 microns column and a flow rate of 10 microL/min has been coupled to an ion trap mass spectrometer using electrospray ionisation (ESI) to enable the rapid and effective identification of metabolites in urine, following oral administration of a novel human neutrophil elastase inhibitor, GW311616. Metabolites were identified from their mass (MS) spectra and tandem (MS/MS) mass spectra using minimal sample (1 microL of urine) and no sample pretreatment. Sensitivity assessment has shown that both molecular weight and structural information is obtainable on as little as 5 pg of compound, making the capillary LC/ion trap system as described an ideal analytical tool for the detection and characterisation of low level metabolites in biofluids (particularly when sample volume is limited). This level of detection was unattainable using a triple quadrupole mass spectrometer operating in full-scan mode, although 200 fg on column was detected using selected reaction monitoring target analysis.  相似文献   

15.
The formation of linoleic acid radical species under the oxidative conditions of the Fenton reaction (using hydrogen peroxide and Fe (II)) was monitored by FAB-MS and ES-MS using the spin trap 5,5-dimethyl-1-pyrrolidine-N-oxide, DMPO. Both the FAB and ES mass spectra were very similar and showed the presence of ions corresponding to carbon- and oxygen centered spin adducts (DMPO/L*, DMPO/LO*, and DMPO/LOO*). Cyclic structures, formed between the DMPO oxygen and the neighboring carbon of the fatty acid, were also observed. Electrospray tandem mass spectrometry of these ions was performed to confirm the proposed structure of these adducts. All MS/MS spectra showed an ion at m/z 114, correspondent to the [DMPO + H]+, and a fragment ion due to loss of DMPO (loss of 113 Da), confirming that they are DMPO adducts. ES-MS/MS spectra of alkoxyl radical adducts (DMPO/LO*) showed an additional ion at m/z 130 [DMPO - O + H]+, while ES MS/MS of peroxyl radical adducts (DMPO/LOO*) showed a fragment ion at m/z 146 [DMPO - OO + H]+, confirming both structures. Other fragment ions were observed, such as alkyl acylium radical ions, formed by cleavage of the alkyl chain after loss of water and the DMPO molecule. The identification of fragment ions observed in the MS/MS spectra of the different DMPO adducts suggests the occurrence of structural isomers containing the DMPO moiety both at C9 and C13. The use of ES tandem mass spectrometry, associated with spin trapping experiments, has been shown to be a valuable tool for the structural characterization of carbon and oxygen-centered spin adducts of lipid radicals.  相似文献   

16.
Multiple ion monitoring (MIM)‐dependent acquisition with a triple quadrupole‐linear ion trap mass spectrometer (Q‐trap) was previously developed for drug metabolite profiling. In the analysis, multiple predicted metabolite ions are monitored in both Q1 and Q3 regardless of their fragmentations. The collision energy in Q2 is set to a low value to minimize fragmentation. Once an expected metabolite is detected by MIM, enhanced product ion (EPI) spectral acquisition of the metabolite is triggered. To analyze in vitro metabolites, MIM‐EPI retains the sensitivity and selectivity similar to that of multiple reaction monitoring (MRM)‐EPI in the analysis of in vitro metabolites. Here we present an improved approach utilizing MIM‐EPI for data acquisition and multiple data mining techniques for detection of metabolite ions and recovery of their MS/MS spectra. The postacquisition data processing tools included extracted ion chromatographic analysis, product ion filtering and neutral loss filtering. The effectiveness of this approach was evaluated by analyzing oxidative metabolites of indinavir and glutathione (GSH) conjugates of clozapine and 4‐ethylphenol in liver microsome incubations. Results showed that the MIM‐EPI‐based data mining approach allowed for comprehensive detection of metabolites based on predicted protonated molecules, product ions or neutral losses without predetermination of the parent drug MS/MS spectra. Additionally, it enabled metabolite detection and MS/MS acquisition in a single injection. This approach is potentially useful in high‐throughout screening of metabolic soft spots and reactive metabolites at the drug discovery stage. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A new strategy using hybrid ion trap/time-of-flight mass spectrometry coupled with high-performance liquid chromatography and post-acquisition data mining techniques was developed and applied to the detection and characterization of degradation products of danofloxacin. The degradation products formed under different forced conditions were separated using an ODS-C18 column with gradient elution. Accurate full-scan MS data were acquired in the first run and processed with the combination of extracted ion chromatograms and LC-UV chromatograms. These processes were able to find accurate molecular masses of possible degradation products. Then, the accurate MS/MS data acquired through data-dependent analysis mode in another run facilitated the structural elucidations of degradation products. As a result, a total of 11 degradation products of danofloxacin were detected and characterized using the developed method. Overall, this analytical strategy enables the acquisition of accurate-mass LC/MS data, search of a variety of degradation products through the post-acquisition processes, and effective structural characterization based on elemental compositions of degradation product molecules and their product ions. The ability to measure degradation products via tandem mass spectrometry coupled with accurate mass measurement, all in only two experimental runs, is one of the most attractive features of this methodology. The results demonstrate that use of the LC/MS-IT-TOF approach appears to be rapid, efficient and reliable in structural characterization of drug degradation products.  相似文献   

18.
This work illustrates the potential of liquid chromatography coupled to a hybrid linear ion trap Fourier Transform Orbitrap mass spectrometer for the simultaneous identification and quantification of 24 drugs of abuse and relevant metabolites in sewage water. The developed methodology consisted of automatic solid-phase extraction using Oasis HLB cartridges, chromatographic separation of the targeted drugs, full-scan accurate mass data acquisition under positive electrospray ionization mode over an m/z range of 50–600 Da at a resolution of 30,000 FWHM and simultaneous MSn measurements to obtain information of fragment ions generated in the linear ion trap. Accurate mass of the protonated molecule, together with at least one nominal mass product ion and retention time allowed the confident identification of the compounds detected in these complex matrices. In addition to the highly reliable qualitative analysis, Orbitrap analyzer also proved to have satisfactory potential for quantification at sub-ppb analyte levels, a possibility that has been very little explored in the literature until now. The limits of quantification ranged from 4 to 68 ng L−1 in influent sewage water, and from 2 to 35 ng L−1 in effluent, with the exception of MDA, morphine and THC that presented higher values as a consequence of the high ionization suppression in this type of samples. Satisfactory recoveries (70–120%) and precision (<30%) for the overall procedure were obtained for all compounds with the exception of meta-chlorophenylpiperazine, methylphenidate and ketamine. Isotope-labelled internal standards were added to sewage samples as surrogates in order to correct for matrix effects and also for possible losses during sample treatment. The methodology developed was applied to sewage water samples from the Netherlands (influent and effluent), and the results were compared with those obtained by LC–MS/MS with triple quadrupole. Several drugs of abuse could be identified and quantified, mainly MDMA, benzoylecgonine, codeine, oxazepam and temazepam. Orbitrap also showed potential for retrospective investigation of ketamine metabolites in the samples without the need of additional analysis.  相似文献   

19.
A novel LC/MS/MS method that uses multiple ion monitoring (MIM) as a survey scan to trigger the acquisition of enhanced product ions (EPI) on a hybrid quadrupole-linear ion trap mass spectrometer (Q TRAP) was developed for drug metabolite identification. In the MIM experiment, multiple predicted metabolite ions were monitored in both Q1 and Q3. The collision energy in Q2 was set to a low value to minimize fragmentation. Results from analyzing ritonavir metabolites in rat hepatocytes demonstrate that MIM-EPI was capable of targeting a larger number of metabolites regardless of their fragmentation and retained sensitivity and duty cycle similar to multiple reaction monitoring (MRM)-EPI. MIM-based scanning methods were shown to be particularly useful in several applications. First, MIM-EPI enabled the sensitive detection and MS/MS acquisition of up to 100 predicted metabolites. Second, MIM-MRM-EPI was better than MRM-EPI in the analysis of metabolites that undergo either predictable or unpredictable fragmentation pathways. Finally, a combination of MIM-EPI and full-scan MS (EMS), as an alternative to EMS-EPI, was well suited for routine in vitro metabolite profiling. Overall, MIM-EPI significantly enhanced the metabolite identification capability of the hybrid triple quadrupole-linear ion trap LC/MS.  相似文献   

20.
Electrospray ionization linked to quadrupole/orthogonal-acceleration time-of-flight (Q/oaTOF) and ion trap equipment was used to study the fragmentation behavior of the linear side-chain cyclized peptides of the polymyxin B and E antibiotics. This study exemplifies both the benefits and the drawbacks of mass spectrometric techniques for the determination of the sequence of such complex linear side-chain cyclized peptides. Q/oaTOF accurate mass measurements did not help sufficiently to assign the product ions observed in the product ion spectra. An ion trap mass spectrometer providing MS(n) capability was used to eliminate ambiguities encountered with a single MS/MS approach. The complex fragmentation behavior of these compounds of well-established structure is described which could be useful for structural characterization of unknown substances related to polymyxin B and E in the future.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号