首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An extraction technique is described for vitamin K1 in medical foods, using accelerated solvent extraction (ASE) in conjunction with matrix solid-phase dispersion (MSPD). The medical food sample is treated as it would be with MSPD extraction, followed by ASE for a hands-free automated extraction. The vitamin K1 in the ASE extract is then quantitated by reversed-phase liquid chromatography with fluorescence detection. The chromatography specifications are identical to those in previous work that used MSPD only, with a limit of detection of 6.6 pg and a limit of quantitation of 22 pg on column. Recoveries, which were determined for an analyte-fortified zero control reference material for medical foods, averaged 97.6% (n = 25) for vitamin K1. The method provides a rapid, automatic, specific, and easily controlled assay for vitamin K1 in fortified medical foods with minimal solvent usage.  相似文献   

2.
Determination of small amounts of vitamin K1 (0.8 microg/g) in nutritional supplements with high fat content (20 mg/g) was performed by solid-phase extraction and high-performance liquid chromatography (HPLC) with fluorescence detection after reduction on a platinum oxide catalyst. The concentration ratio of plant oils to vitamin K1 (0.8 microg/g) was about 25,000:1. A sample solution was applied to a solid-phase extraction cartridge and vitamin K1 was eluted with ethanol, followed by HPLC. The proposed method was simple, rapid (analysis time: ca. 12 min), sensitive [detection limit: ca. 0.1 pg per injection (100 microl) at a signal-to-noise ratio of 3:1], highly selective and reproducible [relative standard deviation: ca. 1.3%. (n=5)]. The calibration graph of vitamin K1 was linear in the range of 0-2 pg per injection (100 microl). Recovery of vitamin K1 was over 90% by the standard addition method.  相似文献   

3.
A highly sensitive method for measuring endogenous vitamin K1, menaquinone-4 (which is one of the K2 vitamins) and vitamin K1 2,3-epoxide in human plasma was developed, based on high-performance liquid chromatography with coulometric reduction and fluorimetric detection, following extraction from plasma and purification on a Sep-Pak silica cartridge. The detection limits of vitamin K1, menaquinone-4 and vitamin K1 2,3-epoxide were 5, 5 and 8 pg per injection for the standard substances and 30, 30 and 50 pg/ml in human plasma, respectively.  相似文献   

4.
A liquid chromatographic method for vitamin K1 in milk-based infant formula is described. The vitamins are extracted from infant formula by matrix solid-phase dispersion and quantitated by reversed-phase chromatography with fluorescence detection. Vitamin K1 is converted to the fluorescent hydroquinone with a postcolumn zinc reductive reactor. The limit of detection is 12 pg, and the limit of quantitation is 38 pg on-column. Linear responses were obtained in the range 0.55-22.1 ng/ml (r2 = 0.9998). Recoveries of vitamin K1 from an analyte-fortified blank material for milk-based infant formula averaged 91.7% (n = 25). The method provides a rapid, specific, and easily controlled assay for vitamin K1 in fortified infant formula.  相似文献   

5.
We have developed a method to analyze stable carbon isotope ((13)C/(12)C) ratios in a variety of carbohydrates using high-performance liquid chromatography/isotope ratio mass spectrometry (HPLC/IRMS). The chromatography is based on strong anion-exchange columns with low strength NaOH eluents. An eluent concentration of 1 mM resulted in low background signals and good separation of most of the typical plant neutral carbohydrates. We also show that more strongly bound carbohydrates such as acidic carbohydrates can be separated by inclusion of NO(3) (-) as an inorganic pusher ion in the eluent. Analyses of neutral carbohydrate concentrations and their stable carbon isotope ratios are shown for plant materials and marine sediment samples both at natural abundance and for (13)C-enriched samples. The main advantage of HPLC/IRMS analysis over traditional gas chromatography based methods is that no derivatization is needed resulting in simple sample treatment and improved accuracy and reproducibility.  相似文献   

6.
The purpose of this study was to validate a method for measuring vitamin K isomers in rat tissues by liquid chromatography (LC) with fluorescence detection after simple solvent extraction. This method uses separation on a C30 column, followed by zinc reduction and fluorescence measurement (243 nm, excitation; 430 nm, emission) to detect and quantitate vitamin K isomers. We were able to separate cis- and trans-vitamin K1 in methylene chloride extracts of homogenized rat livers and in hexane extracts of rat plasma. Tissue extracts were evaporated and rediluted with tetrahydrofuran-methanol (1 + 1) or methanol before being injected under isocratic conditions onto the LC column. Liver tissue of Fischer 344 rats fed a vitamin K1-containing diet ad libitum contained approximately 20 and 60 ng/g cis- and trans-vitamin K1, respectively. Mean recoveries of vitamin K1 isomers from spiked liver were 92 +/- 11% for cis-vitamin K1 and 106 +/- 5% for trans-vitamin K1. We recovered 96 +/- 8% of trans-vitamin K1 added at 1, 3, and 6 ng/mL to plasma (containing an endogenous level of 4 ng/g) from the same rats; we recovered 112 +/- 5% when trans-vitamin K1 was added to human serum (National Institute of Standards and Technology Standard Reference Material 968C). This direct method shows significant potential for the selective measurement of vitamin K1 isomers in tissues.  相似文献   

7.
A high-performance liquid chromatographic method for determining phylloquinone (vitamin K1) in soy bean oils is described. Resolution of vitamin K1 from interfering peaks of the matrix was obtained after enzymatic digestion, extraction and liquid-solid chromatography on alumina. An isocratic reversed-phase chromatography with UV detection was used in the final stage. The quantitation was carried out by the standard addition method, and the recovery of the whole procedure was 88.2%.  相似文献   

8.
胡灿  梅宏成  郭洪玲  孙振文  刘占芳  朱军 《色谱》2021,39(4):376-383
炸药的深度比对与溯源对于爆炸案事件的侦破具有重大意义,以不同地域来源的原料或不同生产工艺生产的炸药,其组成元素的稳定同位素比值具有差异,因而稳定同位素比值可作为炸药深度比对与溯源的重要指标。稳定同位素比值质谱法(IRMS)作为一种高精度的稳定同位素比值测量手段,已逐渐发展成熟,与元素分析仪、气相色谱仪、液相色谱仪等仪器联用,在食品安全、环境保护、法庭科学等领域应用广泛。IRMS在炸药比对与溯源上亦发挥了重要作用,自1975年IRMS被应用于区分不同国家生产的三硝基甲苯(TNT)以来,IRMS已成功用于多种炸药的分析。但目前尚未见有文献系统地总结常见炸药的稳定同位素比值分析研究进展。该文介绍了稳定同位素比值分析的相关原理、仪器组成及特点,分别总结了硝酸铵、黑火药、TNT、太恩、黑索金等常见炸药的稳定同位素比值分析方法,汇总了文献报道的不同国家生产的硝酸铵、黑火药、TNT等炸药的稳定同位素比值。文章就不同炸药的稳定同位素比值差异、炸药生产、存储过程中相关因素对同位素比值的影响,爆炸前后稳定同位素比值的变化情况等内容进行了分析。本文还指出了目前炸药的稳定同位素比值分析研究中存在的问题,对可能的解决办法进行了讨论,对未来的发展方向提出了建议。  相似文献   

9.
Environmental degradation of organic micropollutants is difficult to monitor due to their diffuse and ubiquitous input. Current approaches—concentration measurements over time, or daughter-to-parent compound ratios—may fall short, because they do not consider dilution, compound-specific sorption characteristics or alternative degradation pathways. Compound-specific isotope analysis (CSIA) offers an alternative approach based on evidence from isotope values. Until now, however, the relatively high limits for precise isotope analysis by gas chromatography—isotope ratio mass spectrometry (GC-IRMS) have impeded CSIA of sub-microgram-per-liter scale micropollutant concentrations in field samples. This study presents the first measurements of C and N isotope ratios of the herbicide atrazine and its metabolite desethylatrazine at concentrations of 100 to 1,000 ng/L in natural groundwater samples. Solid-phase extraction and preparative HPLC were tested and validated for preconcentration and cleanup of groundwater samples of up to 10 L without bias by isotope effects. Matrix interferences after solid-phase extraction could be greatly reduced by a preparative HPLC cleanup step prior to GC-IRMS analysis. Sensitivity was increased by a factor of 6 to 8 by changing the injection method from large-volume to cold-on-column injection on the GC-IRMS system. Carbon and nitrogen isotope values of field samples showed no obvious correlation with concentrations or desethylatrazine-to-atrazine ratios. Contrary to expectations, however, δ 13 C values of desethylatrazine were consistently less negative than those of atrazine from the same sites. Potentially, this line of evidence may contain information about further desethylatrazine degradation. In such a case, the common practice of using desethylatrazine-to-atrazine ratios would underestimate natural atrazine degradation.  相似文献   

10.
We have investigated a novel application of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) for the quantitative analysis of the isoflavones in food matrices. Previous methods have been hampered by the lack of analytical standards to introduce early enough in the extraction procedure to allow compensations for losses at all stages of the procedure. In this work we have produced standard materials that can be added at the initial extraction, by intrinsically labelling soya plants by growing them in an atmosphere enriched in the stable isotope of carbon in CO(2). On analysis these plants were shown to contain phytoestrogens at a high (up to 20%) level of enrichment. The dried plant material has been used to estimate the isoflavone concentrations of a set of spiked flours. For daidzein the methodology was shown to produce results comparable to those achieved by GC/MS techniques. The method was less successful for genistein, possibly due to the greater fragility of this compound under the conditions required for the analysis.  相似文献   

11.
The use of stable isotope labelled glucose provides insight into glucose metabolism. The 13C‐isotopic enrichment of glucose is usually measured by gas chromatography/mass spectrometry (GC/MS) or gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). However, in both techniques the samples must be derivatized prior to analysis, which makes sample preparation more labour‐intensive and increases the uncertainty of the measured isotopic composition. A novel method for the determination of isotopic enrichment of glucose in human plasma using liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) has been developed. Using this technique, for which hardly any sample preparation is needed, we showed that both the enrichment and the concentration could be measured with very high precision using only 20 µL of plasma. In addition, a comparison with GC/MS and GC/IRMS showed that the best performance was achieved with the LC/IRMS method making it the method of choice for the measurement of 13C‐isotopic enrichment in plasma samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A liquid chromatographic (LC) method is described for the determination of vitamin K1 in medical foods. The sample is enzymatically digested with lipase and alpha-amylase and extracted with 1% sodium bicarbonate solution-isopropanol (1 + 1). After C18 solid-phase extraction, vitamin K1 is separated by nonaqueous reversed-phase LC, converted to the hydroquinone by postcolumn zinc reduction, and quantitated by fluorescence detection. The limit of detection is 8 pg (3 sigma), and the limit of quantitation is 27 pg (10 sigma) on column. Linear response ranged from 0.1 to 1.0 ng vitamin K1 (r= 0.9999). The mean recovery (n = 38) for all spiking levels was 101.6 +/- 2.85%. Analysis of Standard Reference Material 1846, Infant Formula, gave a mean value of 0.95 +/- 0.088 mg vitamin K/kg (K or K1?) (n = 31) with a coefficient of variation of 9.26.  相似文献   

13.
液相色谱-同位素比质谱(LC-IRMS)是一种特征化合物同位素分析技术,该技术利用LC IsoLink接口设备实现液相色谱与同位素比质谱的联用,通过检测目标物质的稳定碳同位素比(δ13C),实现样品的产地来源与品质真实性鉴定。该文总结了IRMS与LC-IRMS技术的概况,以及过去20年LC-IRMS的发展历程;归纳整理了LC-IRMS在食品安全、生态与环境、生命科学及考古学等领域的应用情况;评述了LC-IRMS面临的技术局限、挑战及其未来的发展趋势。  相似文献   

14.
建立了化妆品中维生素K1的高效液相色谱分析方法.将样品采用饱和氯化钠溶液-正己烷溶剂体系按不同的添加顺序进行分散、提取后,用高效液相色谱/二极管阵列检测器(HPLC/DAD)进行测定.其中,对油脂含量较高样品的提取液需经硅胶固相萃取柱进一步净化后测定.对不同的提取和净化方法作了系统研究,在优化实验条件下,方法的回收率为...  相似文献   

15.
A pre-concentration system has been validated for use with a gas chromatography/mass spectrometry/isotope ratio mass spectrometer (GC/MS/IRMS) to determine ambient air (13)C/(12)C ratios for methyl halides (MeCl and MeBr) and chlorofluorocarbons (CFCs). The isotopic composition of specific compounds can provide useful information on their atmospheric budgets and biogeochemistry that cannot be ascertained from abundance measurements alone. Although pre-concentration systems have been previously used with a GC/MS/IRMS for atmospheric trace gas analysis, this is the first study also to report system validation tests. Validation results indicate that the pre-concentration system and subsequent separation technologies do not significantly alter the stable isotopic ratios of the target methyl halides, CFC-12 (CCl(2)F(2)) and CFC-113 (C(2)Cl(3)F(3)). Significant, but consistent, isotopic shifts of -27.5 per thousand to -25.6 per thousand do occur within the system for CFC-11 (CCl(3)F), although the shift is correctible. The method presented has the capacity to separate these target halocarbons from more than 50 other compounds in ambient air samples. Separation allows for the determination of stable carbon isotope ratios of five of these six target trace atmospheric constituents within ambient air for large volume samples (相似文献   

16.
A method for the analysis of thyroxine in human serum, utilising 'exact matching' isotope dilution mass spectrometry (IDMS) in combination with liquid chromatography/tandem mass spectrometry (LC/MS/MS), has been developed with a limit of quantification of 0.5 ng g(-1) of thyroxine in human serum. The extraction and clean-up of thyroxine from serum involves an efficient protein-precipitation stage followed by a solid-phase extraction procedure to produce an extract essentially free from interfering compounds. The method is reproducible, with expanded uncertainties of less than 2%, and is relatively fast to perform.  相似文献   

17.
Stable isotope analysis of sedimentary carbon in lakes can help reveal changes in terrestrial and aquatic carbon cycles. A method based on a single, photosynthetic organism, where host effects are minimised, should offer more precision than carbon isotope studies of bulk lake sediments. Here we report the development of a systematic method for use on fossil lacustrine diatom frustules, adapted from previous studies in marine environments. A step-wise cleaning experiment on diatomaceous lake sediments from Lake Challa, near Mount Kilimanjaro, was made to demonstrate the necessary treatment stages to remove external sedimentary carbon. Changes in soluble carbon compounds during these cleaning experiments were measured using gas chromatography/mass spectrometry (GC/MS). The mass spectrometry methods were refined to measure the small percentage of carbon in these samples and details of these methods are presented. Samples of cleaned diatoms containing <1% carbon yielded robust results. Carbon isotope analyses of diatom samples containing different species mixtures were performed and suggested that differences existed, although the effects lay within current experimental error and require further work. Unlike what was found in work on oxygen and silicon isotopes from diatom frustules, mineral contamination had no discernible impact on the diatom carbon isotope ratios from these sediments. The range of values found in the lakes investigated thus far can be interpreted with reference to the supply and nature of carbon from the catchment as well as to the demand generated from lake primary productivity.  相似文献   

18.
Assessing the environmental fate of chiral micropollutants such as herbicides is challenging. The complexity of aquatic systems often makes it difficult to obtain hydraulic mass balances, which is a prerequisite when assessing degradation based on concentration data. Elegant alternatives are concentration-independent approaches like compound-specific isotope analysis or enantiospecific concentration analysis. Both detect degradation-induced changes from ratios of molecular species, either isotopologues or enantiomers. A combination of both—enantioselective stable isotope analysis (ESIA)—provides information on 13C/12C ratios for each enantiomer separately. Recently, Badea et al. demonstrated for the first time ESIA for the insecticide α-hexachlorocyclohexane. The present study enlarges the applicability of ESIA to polar herbicides such as phenoxy acids: 4-CPP ((RS)-2-(4-chlorophenoxy)-propionic acid), mecoprop (2-(4-chloro-2-methylphenoxy)-propionic acid), and dichlorprop (2-(2,4-dichlorophenoxy)-propionic acid). Enantioselective gas chromatography–isotope ratio mass spectrometry was accomplished with derivatization prior to analysis. Precise carbon isotope analysis (2σ?≤?0.5‰) was obtained with ≥7 ng C on column. Microbial degradation of dichlorprop, 2-(2,4-dichlorophenoxy)-propionic acid by Delftia acidovorans MC1 showed pronounced enantiomer fractionation, but no isotope fractionation. In contrast, Badea et al. observed isotope fractionation, but no enantiomeric fractionation. Hence, the two lines of evidence appear to complement each other. They may provide enhanced insight when combined as ESIA.  相似文献   

19.
He C  Li S  Liu H  Li K  Liu F 《Journal of chromatography. A》2005,1082(2):143-149
Based on aqueous two-phase systems (ATPS) consisting of 1-butyl-3-methylimidazolium chloride, a hydrophilic ionic liquid (IL), and K2HPO4, a new and simple extraction technique, coupled with a reversed-phase high performance liquid chromatography (RP-HPLC), was developed for the simultaneous concentration and analysis of testosterone (T) and epitestosterone (ET) in human urine. Under the optimal conditions, the extraction efficiencies for both analytes were 80-90% in a one-step extraction. The method required only 3.0 mL of urine and a single hydrolysis/deproteinization/extraction step followed by direct injection of the IL-rich upper phase into HPLC system for analysis. The method has been satisfactorily applied to the analysis of T and ET in human urine with detection limits of 1 ng/mL and linear ranges of 10-500 ng/mL for both compounds. Compared with conventional liquid-liquid extraction or solid phase extraction, this new method is much "greener" due to no use of volatile organic solvent and low consumption of IL. The proposed extraction technique opens up new possibilities in the separation of other drugs.  相似文献   

20.
The key compound in the wine off-flavor phenomenon "Untypische Alterungsnote" (UTA) is 2-aminoacetophenone (AAP). A new method for its quantitative analysis in wine is described. The analysis is based on solid phase extraction with LiChrolut EN as sorbent material followed by multidimensional gas chromatography coupled to mass spectrometry (MDGC-MS). Matrix effects due to the complex wine aroma composition could be overcome by an alkaline washing step of the extract and the use of selected ion monitoring as detection mode. Quantification is based on a stable isotope dilution assay using deuterated 2-aminoacetophenone as internal standard.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号