共查询到20条相似文献,搜索用时 0 毫秒
1.
Development of a liquid chromatography/tandem mass spectrometry assay for the quantification of lisinopril in human plasma 总被引:2,自引:0,他引:2
A simple and sensitive liquid chromatography/tandem mass spectrometry method employing electrospray ionization, to quantify lisinopril in human plasma using pseudoephedrine hydrochloride as the internal standard (IS), has been developed and validated. A mixture of methanol and 0.1% formic acid in water (50:50, v/v) was used as the isocratic mobile phase. A simple liquid-liquid extraction procedure was used as sample preparation method. The method validation demonstrated the specificity, lower limit of quantification, accuracy, and precision of measurements. Selected reaction monitoring was specific for lisinopril and pseudoephedrine hydrochloride; no endogenous materials from blank plasma interfered with the analysis of lisinopril or the IS. The assay was linear over the concentration range 0.78-100 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9984-0.9998. The intra- and inter-day precision, determined for quality control samples, were less than 4.18%. The method was employed in a pharmacokinetic study after oral administration of 10 mg lisinopril to 20 healthy volunteers. 相似文献
2.
Sensitive and rapid liquid chromatography/tandem mass spectrometry assay for the quantification of amlodipine in human plasma 总被引:1,自引:0,他引:1
Nirogi RV Kandikere VN Mudigonda K Shukla M Maurya S 《Biomedical chromatography : BMC》2006,20(9):833-842
A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of amlodipine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase C(18) column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 409/238 for amlodipine and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 50-10,000 pg/mL for amlodipine in human plasma. The lower limit of quantification was 50 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of amlodipine and the IS from spiked plasma samples were 74.7 +/- 4.6 and 72.1 +/- 2.0%, respectively. A run time of 1.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. The observed maximum plasma concentration (Cmax) of amlodipine (2.5 mg oral dose) was 1425 pg/mL, time to observed maximum plasma concentration (Tmax) was 8.1 h and elimination half-life (T(1/2)) was 50.1 h. 相似文献
3.
Liu F Xu Y Rui L Gao S Dong H Guo Q 《Rapid communications in mass spectrometry : RCM》2006,20(23):3522-3526
A simple, rapid, sensitive and specific liquid chromatography/tandem mass spectrometry method was developed and validated to quantify troxerutin in human plasma. The analyte and rutin, used as the internal standard, were analyzed on a Phenomenex Synergi Fusion RP column interfaced with a triple-quadrupole tandem mass spectrometer using positive electrospray ionization. Acetonitrile/water (20:80 v/v) was used as the isocratic mobile phase, with 0.1% formic acid in water. A simple sample preparation method of protein precipitation with perchloric acid was employed. The assay was linear over the concentration range 31.25-4000 pg/mL. Correlation coefficients generated by linear regression with a 1/x(2) weighting factor ranged from 0.9991 to 0.9996. The intra- and inter-day precision over the entire concentration range were less than 12.28%. The method was successfully applied to a pharmacokinetic study after oral administration of a 300 mg troxerutin drop pill to 18 healthy volunteers. 相似文献
4.
A simple, rapid, sensitive and specific liquid chromatography/electrospray ionization mass spectrometry method was developed and validated to quantify azithromycin in human plasma, using erythromycin as the internal standard (IS). A simple sample preparation method of protein precipitation with methanol was employed. Methanol, acetonitrile and water (12:30:58, v/v/v) were used as the isocratic mobile phase, with 0.1% formic acid and 0.1% ammonium acetate in water. Selected ion monitoring was specific for azithromycin and erythromycin. The assay was linear over the concentration range 4.69-600 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9994 to 0.9998. The intra- and inter-day precisions, calculated from quality control samples, were less than 8.24%. The method was employed in a pharmacokinetic study after oral administration of 500 mg azithromycin dispersible tablet to 20 healthy volunteers. 相似文献
5.
Rapid quantification of lisinopril in human plasma by liquid chromatography/tandem mass spectrometry
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers. 相似文献
6.
To investigate the pharmacokinetics of adefovir as an anti-hepatitis B virus drug, a sensitive and specific liquid chromatography/tandem mass spectrometry method was developed and validated. After a simple protein precipitation using methanol, the post-treatment samples were analyzed on a C(18) column interfaced with a triple-quadrupole tandem mass spectrometer using positive electrospray ionization. A structural analogue, PMPA, was used as the internal standard. The method was linear in the concentration range 0.25-100 ng/mL. The lower limit of quantification was 0.25 ng/mL. The intra- and inter-day relative standard deviation over the entire concentration range was 5.7% or less. The accuracy determined at three concentrations (0.75, 10 and 80 ng/mL for adefovir) was within +/-2.5% relative error. The method described here was successfully applied for the evaluation of pharmacokinetic profiles of adefovir after single oral administration doses of 5, 10 and 20 mg adefovir dipivoxil to ten healthy volunteers. 相似文献
7.
Yin J Aviles P Lee W Ly C Floriano P Ignacio M Faircloth G 《Rapid communications in mass spectrometry : RCM》2003,17(16):1909-1914
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel marine-derived depsipeptide, Aplidin, in human plasma. The method was validated to demonstrate the specificity, recovery, limit of quantitation (LOQ), accuracy, and precision of measurements. The calibration range for Aplidin was established using Aplidin standards from 0.05-50 ng/mL in blank human plasma. The multiple reaction monitoring, based on the transition m/z 1110.7 --> 295.3, was specific for Aplidin, and that based on the transition m/z 1112.6 --> 297.3 was specific for didemnin B (the internal standard); no endogenous materials interfered with the analysis of Aplidin and didemnin B from blank human plasma. The assay was linear over the concentration range 0.05-50.0 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9979 to 0.9999. The mean intra- and interday accuracies for all calibration standards (n = 12) ranged from 97 to 106% (=6% bias), and the mean interday precision for all calibration standards was less than 8.3%. The mean intra- and interday assay accuracy for all quality control replicates (n = 12), determined at each QC level throughout the validated runs, remained below 12 and 7%, respectively. The mean intra- and interday assay precision was less than 13.1 and 10.7% for all QC levels, respectively. The assay is currently used to measure Aplidin plasma concentrations to support clinical trials. 相似文献
8.
A sensitive and convenient high-performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS) assay is described for the (5-HT(lB/lD)) receptor agonist sumatriptan in human plasma. Sumatriptan was recovered from plasma (81.8 +/- 6.8%) by liquid-liquid extraction. The mobile phase flow rate was 0.3 mL/min and consisted of methanol:water:formic acid (90:10:0.1, v/v/v). The analytical column (4.6 x 100 mm) was packed with Partisil C(8) (5 micro m). The standard curve was linear from 0.7 to 70.4 ng/mL (r(2) > 0.99). The lower limit of quantitation was 0.7 ng/mL. The assay was specific, accurate (percentage deviation from nominal concentrations were <15%), precise and reproducible (within- and between-day coefficients of variation <10.3%). Sumatriptan in plasma was stable over three freeze/thaw cycles and at room temperature for one day. The utility of the assay was demonstrated by following sumatriptan plasma concentrations in two healthy subjects for 8-12 h following a single 20 mg intranasal dose. 相似文献
9.
Yin J Aviles P Lee W Ly C Guillen MJ Munt S Cuevas C Faircloth G 《Rapid communications in mass spectrometry : RCM》2006,20(18):2735-2740
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel antineoplastic agent, PM02734, in dog plasma. The method was validated to demonstrate the specificity, limit of quantification (LOQ), accuracy, and precision of measurements. The calibration range for PM02734 was established using PM02734 standards from 0.05 to 100 ng/mL in blank plasma. The dominating ions were doubly charged molecular ions [M+2H]2+ at m/z 740.0 instead of singly charged ones at m/z 1478.4. The selected reaction monitoring (SRM), based on the m/z 740.0 --> 212.2 transition, was specific for PM02734, and that based on the m/z 743.8 --> 212.2 transition was specific for deuterated PM02734 (the internal standard, IS); no endogenous materials interfered with the analysis of PM02734 and IS from blank plasma. The assay was linear over the concentration range 0.05-100 ng/mL. In terms of sensitivity of assay 0.05 ng/mL is a very low LLOQ, especially considering PM02734 is a peptide. The correlation coefficients for the calibration curves ranged from 0.9990 to 0.9999. The mean intraday and interday accuracies for all calibration standards (n = 9) ranged from 93 to 111% (< or =11% bias) in dog plasma, and the mean interday precision for all calibration standards was less than 6.4%. The mean intra- and interday assay accuracy for all quality control replicates in dog plasma (n = 9), determined at each QC level throughout the validated runs, ranged from 85-111% (< or =15% bias) and from 99-109% (< or =9% bias), respectively. The mean intra- and interday assay precision was less than 12.1 and 13.3% for all QC levels, respectively. The assay has been used to support preclinical pharmacokinetic (PK) and toxicokinetic studies. The results showed that preclinical samples could be monitored for PM02734 up to 168 h after dosing, which allowed us to identify multiple elimination phases and accurately estimate PK information. 相似文献
10.
Nirogi R Bhyrapuneni G Kandikere V Mudigonda K Ajjala D Mukkanti K 《Biomedical chromatography : BMC》2008,22(10):1043-1055
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid-liquid extraction, the analyte was separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 384 to m/z 221 for quetiapine and m/z 327 to m/z 270 for the internal standard. The assay exhibited a linear dynamic range of 0.25-500 ng/mL for quetiapine in rat plasma. The lower limit of quantification was 0.25 ng/mL with a relative standard deviation of less than 7%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated method was successfully used to analyze rat plasma samples for application in pre-clinical pharmacokinetic studies. This method in rodent plasma could be adapted for quetiapine assay in human plasma. 相似文献
11.
Chen X Song B Jiang H Yu K Zhong D 《Rapid communications in mass spectrometry : RCM》2005,19(18):2591-2596
Isoniazid and ethambutol are commonly used in various combination treatments for tuberculosis, and for this reason a rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of these two drugs in human plasma. After a simple protein precipitation using methanol, the analytes and the internal standard metformin were chromatographed on a C18 column and detected by MS/MS. An atmospheric pressure chemical ionization interface was chosen to reduce ion suppression from sample matrix components and provide high sensitivity. The LC retention times for isoniazid and ethambutol were 2.46 and 2.27 min, respectively. The method was linear in the concentration range of 10.0-5000 ng/mL for each analyte using 100 microL plasma. The intra- and inter-day precisions, expressed as the relative standard deviation (RSD), were less than 5.7 and 6.4%, determined from QC samples for isoniazid and ethambutol, and the accuracies were within +/-2.1% and +/-4.5% in terms of relative error, respectively. The method was successfully employed in a pharmacokinetic study after oral administration of a multicomponent formulation containing 150 mg isoniazid, 500 mg ethambutol, 150 mg rifampicin and 250 mg pyrazinamide. 相似文献
12.
A sensitive, specific and rapid high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was described and validated for the quantification of ambroxol in human plasma using enalaprilat as the internal standard (IS). Chromatographic separation was performed on a Lichrospher CN column with a mobile phase of methanol and water (containing 0.1% formic acid) (70:30, v/v). The total run time was 5.0 min for each sample. The analytes was detected by mass spectrometry with electrospray ionization source in positive selected reaction monitoring mode. The precursor-fragment ion reaction for ambroxol was m/z 378.9 --> 263.8, and for IS was m/z 349.0 --> 205.9. The linearity was established over the concentration range of 1.56-400.00 ng/mL. The inter-day and the intra-day precisions were all within 10%. A simple protein precipitation with methanol was adopted for sample preparation. The extraction recoveries of ambroxol and IS were higher than 90.80%. The validated method was successfully applied in pharmacokinetic study after oral administration of 90 mg ambroxol to 24 healthy volunteers. 相似文献
13.
Cédric Mesmin Mathieu Dubois François Becher François Fenaille Eric Ezan 《Rapid communications in mass spectrometry : RCM》2010,24(19):2875-2884
Apelin peptides are of great interest owing to their involvement in physiological and pathological processes and they have been proposed as novel biomarkers for heart failure. The plasma concentrations of bioactive peptides of 12 (apelin‐12), 13 (apelin‐13) and pyroglutamyl apelin‐13 (apelin‐p13), 17 (apelin‐17) and 36 (apelin‐36) amino acids are reported to range from 20 to 4000 pg/mL in healthy subjects. As standard immunoassays cannot specifically quantify each apelin peptide, we have developed a sensitive and targeted multiplexed liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for each plasma apelin fragment. The approach was based on a cation‐exchange extraction step of apelin forms present in human plasma. Apelin‐12, ‐13, ‐p13, ‐17 and ‐36 were quantified using a triple quadrupole mass spectrometer operating in the multiple reaction monitoring mode. Stable isotope‐labeled internal standards were used for quantification. Following assay validation, apelin peptide stability in plasma was investigated. Ten plasma samples from healthy donors were analyzed both with a standard immunoassay and with our LC/MS/MS method. The immunoassay results for the ten healthy donors showed immunoreactive plasma apelin concentrations ranging from 208 to 466 pg/mL. The lower limits of detection of our LC/MS/MS assay ranged from 10 to 50 pg/mL for apelin‐12, ‐13, ‐p13, ‐17, and ‐36. Surprisingly, none of the five expected circulating forms of apelin was detected. These results question the nature and/or the concentration of circulating apelin peptides as well as the specificity of the immunoassays that have hitherto been used for clinical applications. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
14.
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. 相似文献
15.
16.
A high performance liquid chromatography/tandem mass spectrometry assay was first developed and validated for the quantification of methyl protodioscin (MPD), a natural furostanol saponin with distinct antitumor activity, in rat plasma with 17alpha-ethinylestradiol as internal standard (IS). Methanol-mediated protein precipitation was employed for plasma sample pretreatment. The separation was achieved on a C(18) column (150 x 4.6 mm, i.d., 5 microm) by isocratic elution with methanol-water (72:28, v/v) as mobile phase at a flow rate of 1.0 mL/min. Ion acquisition was performed in selective reaction monitoring positive mode by monitoring the transition of m/z 1085.7 --> 1053.7 for MPD, and in selective ion monitoring negative mode by monitoring the deprotonated ion m/z 295.5 for IS. The assay was linear over the concentration range of 2.024-270.0 microg/mL with 2.024 microg/mL as the lower limit of quantification. It was specific, accurate, precise and reproducible with intra- and inter-run RSD <8.3% and RE between -11.5 and 12.8%. The assay was successfully applied to a preclinical pharmacokinetic study after an intravenous dose of 40 mg/kg MPD to rats. 相似文献
17.
Li X Wang Y Wang J Fawcett JP Zhao L Gu J 《Rapid communications in mass spectrometry : RCM》2007,21(2):247-251
A rapid and sensitive method for the determination of miglitol in human plasma using voglibose as internal standard has been developed and validated. Samples of plasma were deproteinated with acetonitrile and washed with dichloromethane before being analyzed by reversed-phase high-performance liquid chromatography (HPLC). Separation was carried out on a short Nucleosil C(18) column (5 microm, 50 x 4.6 mm i.d.) using 10 mmol/L ammonium acetate at 1.0 mL/min as mobile phase. The detector was an Applied Biosystems Sciex API 4000 mass spectrometer using atmospheric pressure chemical ionization (APCI) for ion production. The instrument was operated at unit resolution in the multiple reaction monitoring mode. The assay was linear over the range 5.00-2000 ng/mL with a limit of detection of 1.00 ng/mL. Intra- and inter-day precision were <2.82% and <2.92%, respectively, with accuracy of 93.3-106%. The assay was successfully applied to a clinical pharmacokinetic study of miglitol given as a single oral dose (50 mg) to healthy volunteers. 相似文献
18.
Nirogi RV Kandikere VN Shukla M Mudigonda K Maurya S Komarneni P 《Rapid communications in mass spectrometry : RCM》2006,20(12):1864-1870
A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of perindopril in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 369/172 for perindopril and m/z 417/234 for the internal standard. The method exhibited a linear dynamic range of 0.1-100 ng/mL for perindopril in human plasma. The lower limit of quantification was 0.1 ng/mL with a relative standard deviation of less than 6.1%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 450 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies. 相似文献
19.
An HPLC/MS/MS method for the determination of arbidol in human plasma was developed. Arbidol and internal standard (loratadine) were extracted from alkaline plasma with tert-butyl methyl ether and analyzed on a Zorbax SB C18 column (30 x 2.1 mm id, 3.5 microm particle size). The detection was by monitoring arbidol at m/z 479.1 --> 434.1 and the internal standard at m/z 383.2 --> 337.2. The method was validated according to U.S. Food and Drug Administration guidelines. The calibration curve was linear over the range of 0.5-500 ng/mL using a 100 microL sample volume. The intraday and interday precisions were less than 6.5%, and acceptable values were obtained for accuracy, recovery, and sensitivity. The developed method was selective, simple, sensitive, and easily applicable. 相似文献
20.
dos Reis EO Vianna-Jorge R Suarez-Kurtz G Lima EL Azevedo Dde A 《Rapid communications in mass spectrometry : RCM》2005,19(12):1666-1674
A sensitive and specific assay for detection of busulfan in human plasma was developed. The assay is based on rapid isolation of busulfan by liquid-liquid extraction with ethyl acetate, and detection by high-performance liquid chromatography with electrospray ionization and tandem mass spectrometry. 1,6-Bis(methanesulfonyloxy)hexane, a synthesized analogue of busulfan, was used as the internal standard (IS). The acquisition was performed in the multiple reaction monitoring mode; busulfan and the IS were detected with no interferences from plasma matrix. The method was linear over the range 5-2500 ng mL(-1), with r2 > 0.99 and a run time of only 3.5 min. The intra- and inter-assay precisions were in the ranges 2.1-11.9% and 3.2-10.1%, respectively, and the intra- and inter-assay accuracies were 92.2-107.6% and 94.7-104.1%, respectively. The absolute recoveries were 82.0% (20 ng mL(-1)), 90.6% (1000 ng mL(-1)) and 80.0% (2000 ng mL(-1)) for busulfan, and 89.1% for the IS (1000 ng mL(-1)). The limits of detection and quantification were 2 and 5 ng mL(-1), respectively. The validated method was successfully applied to analyze plasma samples obtained from six adults receiving doses of 1 mg kg(-1) in a conditioning regimen prior to bone marrow transplantation. A marked intra-patient variation in busulfan concentrations during the steady state was observed, which limits the application of pharmacokinetic modeling and suggests that continuous therapeutic monitoring is necessary for adequate individualized dosing. In this regard, the present assay brings important advantages relative to other methods described in the literature, i.e., it is highly specific and simple to perform, with a rapid chromatographic run time (3.5 min), and the whole procedure can be completed in 4-5 h, which would permit dose corrections after the third dose allowing earlier and better dosing adjustments towards the target level of busulfan. 相似文献