1.

The Carotenoid S is a new C30 bonded silica stationary phase, intended for reversed-phase chromatographic applications, which is more hydrophobic and consequently shows stronger retention in comparison to conventionally used C18 stationary phases. We compared the non-polar selectivities of the columns for homologous alkylbenzenes in acetonitrile—water and methanol–water mobile phases and polar reversed-phase selectivities employing the interaction indices and the Linear Free Energy Relationship models. Further, we investigated possibilities of separations of structurally closely related compounds in the groups of phenolic acids, flavones, phthalic acids and related compounds and of acylglycerols on the new C30 column and with different types of columns for reversed-phase chromatography, including shorter alkyl C4, C8, C18 and phenyl bonded stationary phases. The C30 column has in some aspects properties similar to the non-endcapped Nova-Pak column for separation of some acylglycerols with equal equivalent carbon numbers, but enables separations of longer chain triacylglycerols in a single gradient run.

  相似文献   

2.
Most commercially available instruments for capillary electrochromatography (CEC) have a fixed configuration and lack the flexibility to use shorter columns. Applying a blended stationary phase (a phase consisting of a given ratio of bare silica and reversed phase material) can simulate columns of different length in CEC. The goal of this work was to examine the effect of the degree of blending of reversed-phase columns (with bare silica) on the speed of the separation of neutral compounds in CEC. Optimum column packing mixture was determined from the variation of the solute retention factors as a function of the ratios of blending of reversed-phase and bare silica. By adjusting the column composition, solute retention factors and the analysis run time were halved when compared to a pure reversed-phase column of the same length. Stationary phase blending can be considered as an additional parameter to mobile phase variation, column temperature and applied electric field for the optimization of selectivity and analysis time. By adjusting the stationary phase composition, mobile phase composition, column temperature and applied electric field, the analysis run time of neutral components was decreased more than 75% when compared to a separation obtained on neat reversed-phase column of the same dimensions. The linear dependence of the retention factors as a function of the blend ratio (reversed phase/bare silica) offers a framework for designing a “blended” packed capillary column for CEC separations.  相似文献   

3.
Correlations between the separation selectivity in aqueous and non-aqueous reversed-phase systems and in normal-phase LC systems were investigated for samples containing different numbers of two repeat structural elements. Such samples are best separated in "orthogonal" two-dimensional chromatographic systems, showing selectivity for one type of the repeat structural element only in the first dimension and for the other structural element only in the second dimension. The number of resolved compounds improves as the degree of orthogonality of the separation systems increases with decreasing correlation between the selectivities for the sample structural distribution in the two dimensions. Orthogonal systems with non-correlated selectivities for each repeat structural element provide the highest number of separated peaks and regular arrangement of the peaks over the two-dimensional retention space according to the individual structural element distribution and the best use of the available peak capacity. Fully orthogonal systems are difficult to find in practice. Partially orthogonal system with correlated selectivities for one structural type distribution, but with one system non-distinguishing the distribution for the other structural element are still useful for the two-dimensional separations. The correlations between the selectivities for repeat regular structural increments were employed to evaluate the suitability of phase systems for two-dimensional HPLC separations. The selectivity correlation in various reversed-phase and normal-phase systems was evaluated for two sample types: (1) Various RP columns show significantly inversely correlated selectivities for acyl lengths and numbers of double bonds distribution, but the differences in the double bond selectivity can be used for practical separations of triacylglycerols with the same equivalent carbon numbers. (2) Synthetic EO-PO block (co)oligomers with two-dimensional distribution of oxyethylene and oxypropylene monomer units were separated according to the two distribution types using on-line two-dimensional reversed-phase-normal-phase LC with a C18 column in the first dimension and an aminopropyl silica column in the second dimension.  相似文献   

4.
A method utilizing capillary-channeled polymer (C-CP) fibers as stationary phases in high-performance liquid chromatographic separations has been investigated. Polymeric fibers of differing backbones (polypropylene and polyester) having nominal diameters of approximately 50 and approximately 35 microm and a channeled structure on their periphery were packed into stainless steel tubing (305 x 4.6 mm I.D.) for use in reversed-phase separations of various mixtures. The fibers have eight channels running continuously along the axis which exhibit very high surface activity. As such, solvent transport is affected through the channels through wicking action. Bundles of 1000-3000 fibers are loaded co-linearly into the tubing, providing flow channels extending the entire length of the columns. As a result, backing pressures are significantly lowered (approximately 50% reduction) in comparison to packed-sphere columns. In addition, the capital costs of the fiber material (< US$0.25 per column) are very attractive. Flow-rates of up to 5 ml/min can be used to achieve near baseline separation of related compounds in reasonable run times, indicating very fast mobile phase mass transfer (C-terms). The polymer stationary phases demonstrate high selectivity for a wide variety of analytes with gradient elution employed successfully in many instances. Specifically, separations of three polyaromatic hydrocarbons (benzo[a]pyrene, chrysene, pyrene), mixtures of both organic and inorganic lead compounds [chlorotriethyllead, chlorotriphenyllead, lead nitrate, lead(II) phthalocyanine], and a lipid standard of triglycerides were accomplished on the polymeric stationary phases. Other species of biological interest, including groups of aliphatic and aromatic amino acids have also been effectively separated. The reversed-phase nature of the fiber surfaces is supported through atomic force microscopy measurements using hydrophilic and hydrophobic functionalized polystyrene beads as the probe tips. Separations of the various analytes demonstrate the feasibility of utilizing C-CP fibers as stationary phases in reversed-phase LC. It is envisioned that columns of this nature would be particularly useful in prep-scale separations as well as for immobilization matrices for organic constituents in aqueous environments.  相似文献   

5.
The optimum conditions for the purification of proteins by gradient elution in reversed-phase liquid chromatography were studied, with emphasis on the column length. Because of the strong dependence of the retention of proteins on the mobile phase composition, very short columns can be used successfully to perform analytical separations. A similar conclusion is extended to preparative separations. Columns with different lengths and diameters were used. The dependence of the loading capacity for touching band separation on the column length, diameter and volume was studied, in addition to the regeneration time between successive runs, the starting mobile phase composition and the necessary column efficiency.  相似文献   

6.
Chromatographic properties of silica-, zirconia- and alumina-based columns with octadecyl-, polyethylene glycol- and pentafluorophenylpropyl-bonded stationary phases were tested. Selectivities of nine columns for LC were characterized using chromatographic methods including Walters, Engelhardt, Tanaka and Galushko hydrophobicity and silanol activity tests, measurements of methylene selectivity in various aqueous-methanol and aqueous-acetonitrile mobile phases and of gradient lipophilic capacity as a measure of the effect of the sample hydrophobicity on gradient-elution separations. A semi-empirical interaction indices model, assuming a predominant role of the solvophobic interactions of test compounds with different polarities, was compared with the linear free energy relationships approach taking into account selective polar interactions. The interaction indices model was applied to both non-polar stationary phases bonded on silica, alumina and zirconia supports, and to the non-modified adsorbents in the normal-phase LC. The retention data of isomeric naphthalene disulfonic acids were used to compare the attractive and repulsive ionic interactions of the columns in purely aqueous mobile phases. The results of the hydrophobicity and polarity tests were consistent, and allowed column characterization and classification. Silanol activity was important with octadecyl silica columns, but was relatively insignificant with bonded polyethylene glycol and pentafluorophenylpropyl phases on silica gel support. Polar interactions with the alumina and zirconia support materials significantly affect the retention.  相似文献   

7.
Monolithic silica capillary columns for hydrophilic interaction liquid chromatography (HILIC) were prepared by on-column polymerization of acrylic acid on monolithic silica in a fused silica capillary modified with anchor groups. The products maintained the high permeability (K=5 x 10(-14)m(2)) and provided a plate height (H) of less than 10 microm at optimum linear velocity (u) and H below 20 microm at u=6mm/s for polar solutes including nucleosides and carbohydrates. The HILIC mode monolithic silica capillary column was able to produce 10000 theoretical plates (N) with column dead time (t(0)) of 20s at a pressure drop of 20 MPa or lower. The total performance was much higher than conventional particle-packed HILIC columns currently available. The gradient separations of peptides by a capillary LC-electrospray mass spectrometry system resulted in very different retention selectivity between reversed-phase mode separations and the HILIC mode separations with a peak capacity of ca. 100 in a 10 min gradient time in either mode. The high performance observed with the monolithic silica capillary column modified with poly(acrylic acid) suggests that the HILIC mode can be an alternative to the reversed-phase mode for a wide range of compounds, especially for those of high polarity in isocratic as well as gradient elution.  相似文献   

8.
A commercial Chromolith C18 column and two new stationary phases with mixed ligands bonded on the Kromasil silica gel support, SG-MIX and SG-Chol, were characterized using simple tests based on the retention of non-polar, basic and acidic compounds. Polar and methylene selectivity tests in acetonitrile-water and methanol-water mobile phases revealed lower hydrophobicities of the SG-MIX and SG-Chol columns in comparison to the Chromolith column. The columns were further characterized using new test criteria - gradient oligomer capacity and isomeric selectivity and peak symmetry of naphthalene di-sulphonic acids in aqueous mobile phases. The cholesterolic column shows greater gradient oligomer selectivity for the separation of oligoethylene glycol samples than the SG-MIX and the Chromolith columns. Increased retention and peak tailing, but decreased isomeric selectivity for naphthalene-di-sulphonic acids was observed with the SG-MIX column, because of interactions with various polar bonded groups.  相似文献   

9.
利用溶胶-凝胶(Sol-Gel)技术制备了混合烷基开管毛细管电色谱柱(C8-C13OT-CEC),并考察了其电渗流行为和电色谱性能。研究了流动相中甲醇含量对芳香族中性化合物保留的影响。发现C8-C18OT-CEC柱体现反相分配机理。5种芳香族化合物和4种苯同系物在C8-C13OT-CEC柱上分离良好,同时还考察了分离电压和柱内径对柱效的影响,结果表明高的电压和较小的柱内径能提高柱效。  相似文献   

10.
Surfactants added to the mobile phases in reversed-phase liquid chromatography (RPLC) give rise to a modified stationary phase, due to the adsorption of surfactant monomers. Depending on the surfactant nature (ionic or non-ionic), the coated stationary phase can exhibit a positive net charge, or just change its polarity remaining neutral. Also, micelles in the mobile phase introduce new sites for solute interaction. This affects the chromatographic behavior, especially in the case of basic compounds. Two surfactants of different nature, the non-ionic Brij-35 and the anionic sodium dodecyl sulfate (SDS) added to water or aqueous-organic mixtures, are here compared in the separation of basic compounds (β-blockers and tricyclic antidepressants). The reversible/irreversible adsorption of the monomers of both surfactants on the stationary phase was examined. The changes in the nature of the chromatographic system using different columns and chromatographic conditions were followed based on the changes in retention and peak shape. The study revealed that Brij-35 is suitable for analyzing basic compounds of intermediate polarity, using "green chemistry", since the addition of an organic solvent is not needed and Brij-35 is a biodegradable surfactant. In contrast, RPLC with hydro-organic mixtures or mobile phases containing SDS required high concentrations of organic solvents.  相似文献   

11.
Summary We have determined the interaction behaviour of peptides with hydrophobic stationary phases on analytical columns using isnocratic or shallow gradient elution for the purpose of developing procedures for rapid optimization of conditions for preparative reversed-phase chromatography of peptides. From our investigation of the separation of two closely related decapeptides (differing by one methyl group), in a 1:1 molar ratio on an analytical C8 column, we have found that shallow gradients of 0.1% acetonitrile/min appeared to be the best compromise between resolution and a practical run time for preparative peptide separations. Up to 20mg of the two-peptide mixture was efficiently resolved on the analytical column, with >97% recovery of homogeneous peptides.  相似文献   

12.
The unique ability of macrocyclic ligands, such as the crown ethers and cryptands, to selectively complex alkali metal cations can be used as the basis for chromatographic separations of anions. Specifically, macrocycles which are adsorbed onto a reversed-phase column, form positively charged anion-exchange sites when they combine with eluent cations. Previously we have demonstrated gradient anion separations based on changing the column capacity during the course of the separation by altering the eluent cation, temperature, or organic modifier content using cryptand-based columns. Herein we report that excellent separations can also be achieved using 18-crown-6 based columns. In this column, anion retention increases with increasing eluent strength and organic modifier content. This observation is in keeping with the relatively moderate affinity of crown ethers for alkali metals when compared to cryptands. The separation of anions achieved by optimizing mobile phase variables shows that isocratic separations of anions on the crown-based column are almost as good as separations achieved only under gradient conditions on cryptand-based columns. Cation gradients provide additional improvements on the separations using the crown-based column.  相似文献   

13.
The rapid separation of inorganic anions on short monolithic columns permanently coated with a long chained zwitterionic carboxybetaine-type surfactant is shown. The surfactant, N-dodecyl-N,N-(dimethylammonio)undecanoate (DDMAU), was used to coat 2.5, 5.0 and 10 cm long reversed-phase silica monoliths, resulting in a permanent zwitterionic exchange surface when used with aqueous based eluents. The unique structure of the surfactant results in a charge double layer structure on the surface of the stationary phase, with strong internal anionic and weak external cationic exchange groups. The dissociation of the weak external carboxylic acid group acts to shield the inner anionic exchange site, resulting in substantial effective capacity changes with eluent pH. Utilising this effect with the application of an eluent pH gradient, simultaneously combined with eluent flow-rate gradients, very rapid simultaneous separations of both weakly retained anions and strongly retained polarisable anions was possible, with up to 10-fold decreases in overall run times. Coating stability and retention times under isocratic and isofluentic eluent conditions were shown to be reproducible over >450 repeat injections, with peak efficiency values averaging 29,000 N/m for the 2.5 cm column and 42,000 N/m for the 10 cm monolithic column, again under isocratic elution conditions.  相似文献   

14.
The type of the stationary phase for reversed-phase liquid chromatography significantly affects the sample elution. Hydrodynamic properties, efficiency and gradient elution of proteins were investigated on five commercial C18 columns with wide-pore totally porous particles, with superficially porous layer particles, non-porous particles and a silica-based monolithic bed. The efficiency in the terms of reduced plate height is higher for low-molecular ethylbenzene than for proteins, but depends on the character of the pores in the individual columns tested. The superficially porous Poroshell and the non-porous Micra columns provide the best efficiency for proteins at high mobile phase flow rates, probably because of similar pore architecture in the stationary phase. The Zorbax column with similar pore architecture as the Poroshell active layer, i.e. narrow pore distribution of wider pores shows better efficiency than the packed column with narrow pores and broad pore distribution. The monolithic column shows lower efficiency for proteins at high flow rates, but it performs better than the broad-pore distribution totally porous particulate columns. Different pore architecture affects also the retention and selectivity for proteins on the individual columns. The retention times on all columns can be predicted using the model for reversed-phase gradient elution developed originally for low-molecular compounds. Consideration of the limited pore volume accessible to the biopolymers has negligible effect on the prediction of retention on the columns packed with non-porous or superficially porous particles, but improves the accuracy of the predicted data for the totally porous columns with broad pore distribution.  相似文献   

15.
Many samples contain compounds with various numbers of two or more regular structural groups. Such "multidimensional" samples (according to the Giddings' notation) are best separated in orthogonal chromatographic systems with different selectivities for the individual repeat structural groups, described by separation factors. Correlations between the repeat group selectivities characterize the degree of orthogonality and suitability of chromatographic systems for two-dimensional (2D) separations of two-dimensional samples. The range of the structural units in that can be resolved in a given time can be predicted on the basis of a model describing the repeat group selectivity in the first- and second-dimension systems. Two-dimensional liquid chromatographic system combining reversed-phase (RP) mode in the first dimension and normal-phase (NP) mode in the second dimension were studied with respect to the possibilities of in-line fraction transfer between the two modes. Hydrophilic interaction liquid chromatography (HILIC) with an aminopropyl silica column (APS) is more resistant than classical non-aqueous NP systems against adsorbent desactivation with aqueous solvents transferred in the fractions from the first, RP dimension to the second dimension. Hence, HILIC is useful as a second-dimension separation system for comprehensive RP-NP LCxLC. A comprehensive 2D RP-NP HPLC method was developed for comprehensive 2D separation of ethylene oxide-propylene oxide (EO-PO) (co)oligomers. The first-dimension RP system employed a 120 min gradient of acetonitrile in water on a C18 microbore column at the flow-rate of 10 microL/min. In the second dimension, isocratic HILIC NP with ethanol-dichloromethane-water mobile phase on an aminopropyl silica column at 0.5 mL/min was used. Ten microliter fractions were transferred from the RP to the HILIC NP system at 1 min switching valve cycle frequency.  相似文献   

16.
17.
Macroporous, monolithic capillary electrochromatography (CEC) columns, featuring a hydrophobic stationary phase, have been applied to the separations of steroids with good column efficiency. Using isocratic and gradient elution runs, mixtures of neutral or conjugated steroids could be resolved. While dansylated ketosteroids were detectable through laser-induced fluorescence at attomole levels, the CEC columns coupled to electrospray-ion-trap mass spectrometry featured femtomole detection limits.  相似文献   

18.
A convenient method for the simultaneous determination of various DHPG species present in biological samples is presented. This method utilizes a cation exchange column (25 cm X 4.6 mm i.d.) coupled in series to a short reversed-phase column (5 cm X 4.6 mm i.d.). The mobile phase consists of methanol:0.005M ammonium phosphate buffer, pH 2.5. There is a large polarity difference between DHPG and its esters due to the non-polar side chain of the ester moiety. The simultaneous determination of the diesters, monoesters, and DHPG in these samples using only the cation exchange or the reversed-phase column is not possible without time-consuming gradient elution. In the reversed-phase mode alone, the esters are highly retained relative to DHPG, whereas the esters are only slightly retained on a cation exchange column and are insensitive to changes in pH and ionic strength of the mobile phase. However, a combination of these two columns provides interesting selectivity for these compounds and offers a unique way of controlling the retention times of these species relative to each other. The retention time of esters can be selectively altered (with respect to DHPG) by changing the composition of methanol in the mobile phase. In contrast, the retention time of DHPG is controlled by changing the buffer strength and pH of the mobile phase.  相似文献   

19.
Several procedures are available for simulating and optimising separations in ion chromatography (IC), based on the application of retention models to an extensive database of analyte retention times on a wide range of columns. These procedures are subject to errors arising from batch-to-batch variability in the synthesis of stationary phases, or when using a column having a different diameter to that used when the database was acquired originally. Approaches are described in which the retention database can be recalibrated to accommodate changes in the stationary phase (ion-exchange selectivity coefficient and ion-exchange capacity) or in the column diameter which lead to changes in phase ratio. The entire database can be recalibrated for all analytes on a particular column by performing three isocratic separations with two analyte ions. The retention data so obtained are then used to derive a "porting" equation which is employed to generate the required simulated separation. Accurate prediction of retention times is demonstrated for both anions and cations on 2mm and 0.4mm diameter columns under elution conditions which consist of up to five sequential isocratic or linear gradient elution steps. The proposed approach gives average errors in retention time prediction of less than 3% and the correlation coefficient was 0.9849 between predicted and observed retention times for 344 data points comprising 33 anionic or cationic analytes, 5 column internal diameters and 8 complex elution profiles.  相似文献   

20.
Historically, indirect methods have been used for the HPLC analysis of β-diketone compounds because of the very poor peak shapes and resolution obtained on conventional HPLC stationary phases. In this paper we demonstrate that it is possible to obtain good peak shapes for underivatised β-diketone compounds, in a simulated reaction mixture, using only conventional mobile phases with mixed-mode stationary phase HPLC columns. Optimum conditions were obtained using the mixed-mode reversed-phase strong anion exchange column Primesep B, supplied by SIELC Technologies, with a 0.1% aq. TFA/MeOH gradient method and a column temperature of 55 °C.  相似文献   