首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
Wu CY  Liao WH  Tung YC 《Lab on a chip》2011,11(10):1740-1746
This paper reports a novel pressure sensor with an electrical readout based on electrofluidic circuits constructed by ionic liquid (IL)-filled microfluidic channels. The developed pressure sensor can be seamlessly fabricated into polydimethylsiloxane (PDMS) microfluidic systems using the well-developed multilayer soft lithography (MSL) technique without additional assembly or sophisticated cleanroom microfabrication processes. Therefore, the device can be easily scaled up and is fully disposable. The pressure sensing is achieved by measuring the pressure-induced electrical resistance variation of the constructed electrofluidic resistor. In addition, an electrofluidic Wheatstone bridge circuit is designed for accurate and stable resistance measurements. The pressure sensor is characterized using pressurized nitrogen gas and various liquids which flow into the microfluidic channels. The experimental results demonstrate the great long-term stability (more than a week), temperature stability (up to 100 °C), and linear characteristics of the developed pressure sensing scheme. Consequently, the integrated microfluidic pressure sensor developed in this paper is promising for better monitoring and for characterizing the flow conditions and liquid properties inside the PDMS microfluidic systems in an easier manner for various lab on a chip applications.  相似文献   

2.
3.
Sutarlie L  Yang KL 《Lab on a chip》2011,11(23):4093-4098
Monitoring spatial distribution of chemicals in microfluidic devices by using traditional sensors is a challenging task. In this paper, we report utilization of a thin layer of cholesteric liquid crystal for monitoring ethanol inside microfluidic channels. This thin layer can be either a polymer dispersed cholesteric liquid crystal (PDCLC) layer or a free cholesteric liquid crystal (CLC) layer separated from the microfluidic device by using a thin film of PDMS. They both show visible colorimetric responses to 4% of ethanol solution inside the microfluidic channels. Moreover, the spatial distribution of ethanol inside the microfluidic channel can be reflected as a color map on the CLC sensing layers. By using this device, we successfully detected ethanol produced from fermentation taking place inside the microfluidic channel. These microfluidic channels with embedded PDCLC or embedded CLC offer a new sensing solution for monitoring volatile organic compounds in microfluidic devices.  相似文献   

4.
We propose herein an improved microfluidic system for continuous and precise particle separation. We have previously proposed a method for particle separation called "pinched flow fractionation." Using the previously reported method, particles can be continuously separated according to differences in their diameters, simply by introducing liquid flows with and without particles into a specific microchannel structure. In this study, we incorporated PDMS membrane microvalves for flow rate control into the microfluidic device to improve the separation accuracy. By adjusting the flow rates distributed to each outlet, target particles could be precisely collected from the desired outlet. We succeeded in separating micron and submicron-size polymer particles. This method can be used widely for continuous and precise separation of various kinds of particles, and can function as an important part of microfluidic systems.  相似文献   

5.
Yang M  Yang J  Li CW  Zhao J 《Lab on a chip》2002,2(3):158-163
We have developed a simple method to generate a concentration gradient in a microfluidic device. This method is based on the combination of controlled fluid distribution at each intersection of a microfluidic network by liquid pressure and subsequent diffusion between laminas in the downstream microchannel. A fluid dynamic model taking into account the diffusion coefficient was established to simulate the on-chip flow distribution and diffusion. Concentration gradients along a distance of a few hundred micrometers were generated in a series of microchannels. The gradients could be varied by carefully regulating the liquid pressure applied to the sample injection vials. The observed concentration gradients of fluorescent dyes generated on the microfluidic channel are consistent with the theoretically predicted results. The microfluidic design described in this study may provide a new tool for applications based on concentration gradients, including many biological and chemical analyses such as cellular reaction monitoring and drug screening.  相似文献   

6.
SC Lin  PW Yen  CC Peng  YC Tung 《Lab on a chip》2012,12(17):3135-3141
Flow cytometry is a technique capable of optically characterizing biological particles in a high-throughput manner. In flow cytometry, three dimensional (3D) hydrodynamic focusing is critical for accurate and consistent measurements. Due to the advantages of microfluidic techniques, a number of microfluidic flow cytometers with 3D hydrodynamic focusing have been developed in recent decades. However, the existing devices consist of multiple layers of microfluidic channels and tedious fluidic interconnections. As a result, these devices often require complicated fabrication and professional operation. Consequently, the development of a robust and reliable microfluidic flow cytometer for practical biological applications is desired. This paper develops a microfluidic device with a single channel layer and single sheath-flow inlet capable of achieving 3D hydrodynamic focusing for flow cytometry. The sheath-flow stream is introduced perpendicular to the microfluidic channel to encircle the sample flow. In this paper, the flow fields are simulated using a computational fluidic dynamic (CFD) software, and the results show that the 3D hydrodynamic focusing can be successfully formed in the designed microfluidic device under proper flow conditions. The developed device is further characterized experimentally. First, confocal microscopy is exploited to investigate the flow fields. The resultant Z-stack confocal images show the cross-sectional view of 3D hydrodynamic with flow conditions that agree with the simulated ones. Furthermore, the flow cytometric detections of fluorescence beads are performed using the developed device with various flow rate combinations. The measurement results demonstrate that the device can achieve great detection performances, which are comparable to the conventional flow cytometer. In addition, the enumeration of fluorescence-labelled cells is also performed to show its practicality for biological applications. Consequently, the microfluidic flow cytometer developed in this paper provides a practical platform that can be used for routine analysis in biological laboratories. Additionally, the 3D hydrodynamic focusing channel design can also be applied to various applications that can advance the lab on a chip research.  相似文献   

7.
This paper describes the behavior of bubbles suspended in a carrier liquid and moving within microfluidic networks of different connectivities. A single-phase continuum fluid, when flowing in a network of channels, partitions itself among all possible paths connecting the inlet and outlet. The flow rates along different paths are determined by the interaction between the fluid and the global structure of the network. That is, the distribution of flows depends on the fluidic resistances of all channels of the network. The movement of bubbles of gas, or droplets of liquid, suspended in a liquid can be quite different from the movement of a single-phase liquid, especially when they have sizes slightly larger than the channels, so that the bubbles (or droplets) contribute to the fluidic resistance of a channel when they are transiting it. This paper examines bubbles in this size range; in the size range examined, the bubbles are discrete and do not divide at junctions. As a consequence, a single bubble traverses only one of the possible paths through the network, and makes a sequence of binary choices ("left" or "right") at each branching intersection it encounters. We designed networks so that, at each junction, a bubble enters the channel into which the volumetric flow rate of the carrier liquid is highest. When there is only a single bubble inside a network at a time, the path taken by the bubble is, counter-intuitively, not necessarily the shortest or the fastest connecting the inlet and outlet. When a small number of bubbles move simultaneously through a network, they interact with one another by modifying fluidic resistances and flows in a time dependent manner; such groups of bubbles show very complex behaviors. When a large number of bubbles (sufficiently large that the volume of the bubbles occupies a significant fraction of the volume of the network) flow simultaneously through a network, however, the collective behavior of bubbles-the fluxes of bubbles through different paths of the network-can resemble the distribution of flows of a single-phase fluid.  相似文献   

8.
Zhu X  Yi Chu L  Chueh BH  Shen M  Hazarika B  Phadke N  Takayama S 《The Analyst》2004,129(11):1026-1031
This paper describes the use of arrays of horizontally-oriented reservoirs to deliver liquids through microchannels at a constant flow rate over extended periods of time (hours to days). The horizontal orientation maintains a constant hydraulic pressure drop across microfluidic channels even as the volumes of liquids within the reservoirs change over time. For a given channel-reservoir system, the magnitude of the flow velocity depends linearly on the height difference between reservoirs. The simple structure and operation mechanism make this pumping system versatile. A one-inlet-one-outlet system was used to continuously deliver media for perfusion cell culture, and an array of inlet reservoirs coupled to an outlet reservoir via microchannels was used to drive flows of multiple laminar streams. The parallel pumping scheme conveniently generated various smooth and step concentration gradients, and allowed evaluation of the effect of colchicine on myoblasts. Since the reservoir arrays are configured to be compatible with commercialized multichannel pipettors designed for 96 well plate handling, this simple pumping scheme is envisioned to be broadly useful for medium to high throughput microfluidic perfusion cell culture assays, cell migration assays, multiple laminar flow drug tests, and any other applications needing multiple microfluidic streams.  相似文献   

9.
Chen CY  Wo AM  Jong DS 《Lab on a chip》2012,12(4):794-801
We present a microfluidic device to generate either statically spatial or dynamically temporal logarithmic concentrations. The temporal logarithmic concentration generator was also integrated with planar patch-clamp chips for dose-response assays on ion channels. Proposed serial dilution principle controls the flow pattern at each branching point via designing the flow resistance of microchannels. Simple and linear ratios of the flow resistance results in desired logarithmic concentration at outlets, where the concentrations can be dynamically altered by different combination of valve actuations, were demonstrated. Single-cell pharmacology on ion channels was implemented by sequentially applying logarithmic drug concentrations to patched cells. Inhibitory activity of potassium channels of human embryonic kidney cells was examined by tetraethylammonium solutions. Resulted IC(50) and Hill slope reveal excellent agreement with assays from manually prepared drug concentrations showing the practicability and preciseness of the present approach. Applications include cellular analysis under various drugs and/or logarithmic concentrations at the single-cell level.  相似文献   

10.
In this paper we describe a novel method of manufacturing shape-controlled calcium alginate gel microparticles in a microfluidic device. Both manufacturing shape-controlled microparticles and synthesizing hydrogel microparticles could be performed simultaneously in the microfluidic device. The novel microfluidic device comprised of two individual flow-focusing channels and a synthesizing channel was successfully applied as a continuous microfluidic reactor to synthesize gel microparticles with size and shape control. By passive control based on the microchannel geometric confinement and liquid-phase flow rates, we succeeded in producing monodisperse sodium alginate microparticles with diverse shapes (such as plugs, disks, microspheres, rods, and threads) in the flow-focusing channels of the microfluidic device. The shape and size of the sodium alginate microparticles could be tuned by adjusting the flow rates of the various streams. Further stages of the chemical reaction could be initiated by mixing sodium alginate microparticles and calcium chloride (CaCl2) solution in the synthesizing channel. The shapes of the sodium alginate microparticles could be permanently preserved by the synthesis of calcium alginate gel microparticles. The preparation conditions of size- and shape-controlled calcium alginate microparticles and influence factors were studied.  相似文献   

11.
Profile switching of two-phase flows is often required in microfluidic systems. Manipulation of flow profiles can be realized by control of local surface energy of micro channel through wettability-patterning of channel surface. This article presents a facile approach for wettability-patterning of the micro channels of glass chips. Commercially available octadecyltrichlorosilane (OTS) was used to hydrophobilize the channels via the formation of OTS self-assembly monolayer (SAM), and a UV-source that mainly emits deep UV-light of 254 and 185 nm was employed to degrade the in-channel formed OTS-SAM. The architecture of soda-lime glass/quartz glass hybrid chip was designed to facilitate the deep UV-light effective degrading the OTS-SAM. The established approach, together with the side-by-side laminar-flow patterning technique, was applied to prepare various finely patterned channel networks for different tasks of flow profile switching. The micro device capable of conducting the profile switch from W/O droplets to two separated continuous phases was demonstrated to perform on-chip quick liquid–liquid extraction for the determination of partition coefficients of pharmaceuticals.  相似文献   

12.
A method to fabricate integrated single-walled carbon nanotube/microfluidic devices was developed. This simple process could be used to directly prepare nanotube thin film transistors within the microfluidic channel and to register SWNT devices with the microfludic channel without the need of an additional alignment step. The microfluidic device was designed to have several inlets that deliver multiple liquid flows to a single main channel. The location and width of each flow in the main channel could be controlled by the relative flow rates. This capability enabled us to study the effect of the location and the coverage area of the liquid flow that contained charged molecules on the conduction of the nanotube devices, providing important information on the sensing mechanism of carbon nanotube sensors. The results showed that in a sensor based on a nanotube thin film field effect transistor, the sensing signal came from target molecules absorbed on or around the nanotubes. The effect from adsorption on metal electrodes was weak.  相似文献   

13.
We present a 3-D microfluidic device designed for localized drug delivery to cellular networks. The device features a flow cell comprising a main channel for nutrient delivery as well as multiple channels for drug delivery. This device is one key component of a larger, fully integrated system now under development, based upon a microelectrode array (MEA) with on-chip CMOS circuitry for recording and stimulation of electrogenic cells (e.g. neurons, cardiomyocytes). As a critical system unit, the microfluidics must be carefully designed and characterized to ensure that candidate drugs are delivered to specific regions of the culture at known concentrations. Furthermore, microfluidic design and functionality is dictated by the size, geometry, and material/electrical characteristics of the CMOS MEA. Therefore, this paper reports on the design considerations and fabrication of the flow cell, including theoretical and experimental analysis of the mass transfer properties of the nutrient and drug flows, which are in good agreement with one another. To demonstrate proof of concept, the flow cell was mounted on a dummy CMOS chip, which had been plated with HL-1 cardiomyocytes. A test chemical compound was delivered to the cell culture in a spatially resolved manner. Envisioned applications of this stand-alone system include simultaneous toxicological testing of multiple compounds and chemical stimulation of natural neural networks for neuroscience investigations.  相似文献   

14.
This study discusses the design aspects for the construction of a microfluidic device for comprehensive spatial two‐dimensional liquid chromatography. In spatial two‐dimensional liquid chromatography each peak is characterized by its coordinates in the plane. After completing the first‐dimension separation all fractions are analyzed in parallel second‐dimension separations. Hence, spatial two‐dimensional liquid chromatography potentially provides much higher peak‐production rates than a coupled column multi‐dimensional liquid chromatography approach in which the second‐dimension analyses are performed sequentially. A chip for spatial two‐dimensional liquid chromatography has been manufactured from cyclic olefin copolymer and features a first‐dimension separation channel and 21 parallel second‐dimension separation channels oriented perpendicularly to the former. Compartmentalization of first‐ and second‐dimension developments by physical barriers allowed for a preferential flow path with a minimal dispersion into the second‐dimension separation channels. To generate a homogenous flow across all the parallel second‐dimension channels, a radially interconnected flow distributor containing two zones of diamond‐shaped pillars was integrated on‐chip. A methacrylate ester based monolithic stationary phase with optimized macroporous structure was created in situ in the confines of the microfluidic chip. In addition, the use of a photomask was explored to localize monolith formation in the parallel second‐dimension channels. Finally, to connect the spatial chip to the liquid chromatography instrument, connector ports were integrated allowing the use of Viper fittings. As an alternative, a chip holder with adjustable clasp locks was designed that allows the clamping force to be adjusted.  相似文献   

15.
We describe the development, validation, and application of a novel PDMS-based microfluidic device for imaging leukocyte interaction with a biological substrate at defined shear force employing a parallel plate geometry that optimizes experimental throughput while decreasing reagent consumption. The device is vacuum bonded above a standard 6-well tissue culture plate that accommodates a monolayer of endothelial cells, thereby providing a channel to directly observe the kinetics of leukocyte adhesion under defined shear flow. Computational fluid dynamics (CFD) was applied to model the shear stress and the trajectory of leukocytes within the flow channels at a micron length scale. In order to test this model, neutrophil capture, rolling, and deceleration to arrest as a function of time and position was imaged in the transparent channels. Neutrophil recruitment to the substrate proved to be highly sensitive to disturbances in flow streamlines, which enhanced the rate of neutrophil-surface collisions at the entrance to the channels. Downstream from these disturbances, the relationship between receptor mediated deceleration of rolling neutrophils and dose response of stimulation by the chemokine IL-8 was found to provide a functional readout of integrin activation. This microfluidic technique allows detailed kinetic studies of cell adhesion and reveals neutrophil activation within seconds to chemotactic molecules at concentrations in the picoMolar range.  相似文献   

16.
Herein, quantitative online monitoring of concentration fluctuations of different interesting drugs, namely, the phenothiazine promethazine as well as the anti‐cancer agent mitoxantrone via surface enhanced Raman scattering assay based on a microfluidic device is demonstrated. With the applied liquid/liquid two‐phase‐segmented flow system we succeed in preventing the adhesion of nanoparticle aggregates to the channel walls which is necessary for a quantitative analysis. Even after repeated cycles no carry‐over due to sedimentation of colloid particles is observed. To the best of our knowledge these are the first measurements applying a combination of a microfluidic device with SERS detection for quantitative online monitoring of fluctuations in drug concentrations over hours without use of aggressive chemicals for rinsing the chip surfaces prior to each measurement.  相似文献   

17.
A microfluidic device is presented that performs electrophoretic separation coupled with fraction collection. Effluent from the 3.5 cm separation channel was focused via two sheath flow channels into one of seven collection channels. By holding the collection channels at ground potential and varying the voltage ratio at the two sheath flow channels, the separation effluent was directed to either specific collection channels, or could be swept past all channels in a defined time period. As the sum of the voltages applied to the two sheath flow channels was constant, the electric field remained at 275 V/cm during the separation regardless of the collection channel used. The constant potential in the separation channel allowed uninterrupted separation for late-migrating peaks while early-migrating peaks were being collected. To minimize the potential for carryover between fractions, the device geometry was optimized using a three-level factorial model. The optimum conditions were a 22.5° angle between the sheath flow channels and the separation channel, and a 350 μm length of channel between the separation outlet and the fraction channels. Using these optimized dimensions, the device performance was evaluated by separation and fraction collection of a fluorescently labeled amino acid mixture. The ability to fraction collect on a microfluidic platform will be especially useful during automated or continuous operation of these devices or to collect precious samples.  相似文献   

18.
Choi CH  Yi H  Hwang S  Weitz DA  Lee CS 《Lab on a chip》2011,11(8):1477-1483
This study presents a simple microfluidic approach to the rapid fabrication of complex-shaped microfibers (e.g., single hollow, double hollow, and microbelt), with highly uniform structures, based on a combination of the spontaneous formation of polymeric jet streams and in situ photopolymerization. Two laminar flows of a photocurable fluid and a liquid template (nonpolymerizing fluid) spontaneously form jet streams in equilibrium states in microfluidic channels because of the minimization of the interfacial energy between the two fluids. The formation of the jet streams strongly depends on the spreading coefficients and the evolution time along the downstream of the microfluidic system. Thus, the simple control of the spreading coefficients can guide microfibers into various shapes. The sizes of the core and shell of the hollow fibers can also be readily manipulated by the flow rates of the polymerizing fluid and the liquid template phase. Asymmetric hollow fibers can also be produced in different evolutionary states in the microfluidic system. The microfluidic approach shown here represents a significant step toward the easy fabrication of microfibers with readily controllable structures and geometries. We anticipate that this novel fabrication approach and the prediction method based on spreading coefficients presented in this work can be applied to produce a wide variety of functional microfibrous materials.  相似文献   

19.
Christ KV  Turner KT 《Lab on a chip》2011,11(8):1491-1501
Closed-channel microfluidic devices are widely used in a number of chemical and biological applications; however, it is often difficult to interact with samples, such as cells, that are enclosed inside them. Hydrodynamically confined microflows (HCMs) allow microfluidic-type flows to be generated in open liquid environments, such as Petri dishes, thus greatly increasing the flexibility of microfluidic approaches. HCMs have previously been used for protein patterning and selective cell treatment applications, but the underlying fluid mechanics is not fully understood. Here, we examine the effect of device geometry and flow parameters on the properties of the flow envelope and pressure drop of several two-port HCM devices using a combination of experiments and modeling. A three-port device, which allows for different flow envelope shapes to be generated, is also analyzed. The experimental results agree well with the 3-D computational fluid dynamics simulations, with the majority of the measurements within 10% of the simulations. The results presented provide a framework for understanding the fluid mechanics of HCMs and will aid in the design of HCM devices for a broad range of applications.  相似文献   

20.
Microfluidic device for capillary electrochromatography-mass spectrometry   总被引:2,自引:0,他引:2  
Lazar IM  Li L  Yang Y  Karger BL 《Electrophoresis》2003,24(21):3655-3662
A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号