共查询到20条相似文献,搜索用时 15 毫秒
1.
Yuan J Hashii N Kawasaki N Itoh S Kawanishi T Hayakawa T 《Journal of chromatography. A》2005,1067(1-2):145-152
We have previously demonstrated that liquid chromatography/mass spectrometry equipped with a graphitized carbon column (GCC-LC/MS) is useful for the structural analysis of carbohydrates in a glycoprotein. Here, we studied the monosaccharide composition analysis and quantitative oligosaccharide profiling by GCC-LC/MS. Monosaccharides were labeled with 2-aminopyridine and then separated and monitored by GCC-LC/MS in the selective ion mode. The use of tetradeuterium-labeled pyridylamino (d4-PA) monosaccharides as internal standards, which were prepared by the tagging of standard monosaccharides with hexadeuterium-labeled 2-aminopyridine (d6-AP), afforded a good linearity and reproducibility in ESIMS analysis. This method was successfully applied to the monosaccharide composition analysis of model glycoproteins, fetuin, and erythropoietin. For quantitative oligosaccharide profiling, oligosaccharides released from an analyte and a standard glycoprotein were tagged with d0- and d6-AP, respectively, and an equal amount of d0- and d4-PA oligosaccharides were coinjected into GCC-LC/MS. In this procedure, the oligosaccharides that existed in either analyte or a standard glycoprotein appeared as single ions, and the oligosaccharides that existed in both analyte and a standard glycoprotein were detected as paired ions. The relative amount of analyte oligosaccharides could be determined on the basis of the analyte/internal standard ion-pair intensity ratio. The quantitative oligosaccharide profiling enabled us to make a quantitative and qualitative comparison of glycosylation between the analyte and standard glycoproteins. The isotope tag method can be applicable for quality control and comparability assessment of glycoprotein products as well as the analysis of glycan alteration in some diseases. 相似文献
2.
The aim of this work is to established methods for determination of quinolones (ciprofloxacin, danofloxacin, enrofloxacin, difloxacin and flumequine), regulated by European Union, and sarafloxacin in turkey muscle. An experimental design has been applied for the optimization of the factors that influence the extraction of quinolones from turkey muscle in order to determine the experimental conditions for their extraction with high recoveries. Liquid chromatography with ultraviolet detection (LC-UV), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography tandem mass spectrometry (LC-MS/MS) have been used for the simultaneous quantification of quinolones antibiotics in turkey muscle. The proposed methods have been validated according to the Food Drugs Administration guideline and presents the limit of quantification below the maximum residue limits established by the European Union for quinolones in turkey muscle. The methods developed have been applied to quantification of enrofloxacin and its main metabolite ciprofloxacin in samples of turkey muscle obtained from animals treated with enrofloxacin. 相似文献
3.
Fangfang Wu Zhien Tan Taiping Li Mengli Zhang Yanmei He Shimin Chen Pan Yu Min Ou Lingjie Liu Xijun Wang 《Journal of separation science》2023,46(16):2300148
The Yuquan capsules is a commonly used traditional Chinese Patent Medicine used for the treatment of diabetes mellitus. In this study, a high-throughput analytical method for identifying the chemical composition of Yuquan capsules was established for the first time by using ultra-performance liquid chromatography–quadrupole time of flight mass spectrometry. The data obtained were subjected to fragment analysis and this was combined with UNIFI processing of natural products. One-hundred sixteen compounds were characterized from Yuquan capsules. Twelve of the bioactive compounds were quantitatively analyzed by ultra-performance liquid chromatography-tandem triple quadrupole mass spectrometry. This study was undertaken to obtain a comprehensive chemical profile analysis as well as to evaluate the overall quality of Yuquan capsules. The results will provide a reference for the quality evaluation of different Yuquan preparations. In addition, the data will enable basic pharmacodynamic research into these extensively used capsules. 相似文献
4.
Ren W Lu Y Jing J Zhu J Wan D Zhao D Zheng J Fang F He Y Chen X 《European journal of mass spectrometry (Chichester, England)》2010,16(6):673-678
A sensitive liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method was established and validated for the determination of glycyrrhizin in dog plasma. After treatment with methanol to precipitate proteins, plasma samples were analyzed on a reversed-phase C18 (ODS) column with a mobile phase of methanol:1% formic acid solution (75:25, v/v). MS determination was performed using negative electrospray ionization (negative ESI) in the selected ion monitoring mode. Glycyrrhizin was monitored at the m/z 821 channel and internal standard (gliquidone) at the m/z 526 channel. The calibration curve was linear over the range from 0.05 μg mL(-1) to 10 μg mL(-1) with a correlation coefficient above 0.99. This method was successfully applied to the pharmacokinetic studies in beagle dogs. The absolute bioavailability of glycyrrhizin in beagle dogs was 3.24%. 相似文献
5.
Ortelli D Rudaz S Chevalley AF Mino A Deglon JJ Balant L Veuthey JL 《Journal of chromatography. A》2000,871(1-2):163-172
Saliva was tested and evaluated as a biological matrix for methadone (Mtd) monitoring. Conventional method using a narrow bore C18 column, and an enantioselective method using a narrow bore alpha1-acid glycoprotein column, were developed using liquid chromatography coupled with a mass spectromeric (MS) detector. After optimisation of MS conditions by flow injection analysis, selected ion monitoring detection was used to enhance sensitivity. The total Mtd concentration and the enantiomeric ratio in saliva were validated using an experimental design. The methods were applied to samples provided by heroin addicts undergoing a Mtd treatment. Results on total Mtd determination showed a very poor correlation between saliva and serum, whereas the enantiomeric ratios of Mtd gave a very good one. 相似文献
6.
Matrix effects in pesticide multi-residue analysis by liquid chromatography-mass spectrometry 总被引:3,自引:0,他引:3
Three sample preparation methods: Luke method (AOAC 985.22), QuEChERS (quick, easy, cheap, effective, rugged and safe) and matrix solid-phase dispersion (MSPD) were applied to different fruits and vegetables for analysis of 14 pesticide residues by high-performance liquid chromatography with electrospray ionization-mass spectrometry (HPLC/ESI/MS). Matrix effect, recovery and process efficiency of the sample preparation methods applied to different fruits and vegetables were compared. The Luke method was found to produce least matrix effect. On an average the best recoveries were obtained with the QuEChERS method. MSPD gave unsatisfactory recoveries for some basic pesticide residues. Comparison of matrix effects for different apple varieties showed high variability for some residues. It was demonstrated that the amount of co-extracting compounds that cause ionization suppression of aldicarb depends on the apple variety as well as on the sample preparation method employed. 相似文献
7.
N-Acetyl-N,O,S-permethylated derivatives of oligopeptides were analyzed by high-performance liquid chromatography-mass spectrometry (HPLC-MS) using a moving belt interface. A heated-gas nebulizer was employed for sample deposition, thus permitting the effective use of a water-methanol gradient covering the range from 5% to 95% water at mobile phase flow-rates of 0.5 ml/min. We demonstrate in this paper that it is possible to sequence the octapeptide derived from the C-chain of glucagon by HPLC-MS analysis of a permethylated enzymatic hydrolysate of this peptide using overlap information from the mass spectral patterns. Moreover, it is shown that peptides not readily amenable to analysis by gas chromatography-MS can be analyzed using this approach. Preliminary results suggest that N-acetyl-methyl ester derivatives of oligopeptides may in specific cases also be a useful alternative for HPLC-MS analysis of complex oligopeptide mixtures. 相似文献
8.
Liquid chromatography–mass spectrometry (LC–MS) is a powerful tool for analysis of drugs and their metabolites. We used a column-switching system in combination with atmospheric pressure chemical ionization LC–MS (LC–APCI–MS) for the determination of theophylline and its metabolites in biological samples. The separation was carried out on a reversed-phase column using methanol–20 mM ammonium acetate as a mobile phase at a flow-rate of 1 ml/min in 30 min. In the mass spectrum, the molecular ions of these drugs and metabolites were clearly observed as base peaks. This method is sufficiently sensitive and accurate for the pharmacokinetic studies of these drugs. 相似文献
9.
多肽作为神经递质、激素、受体等参与和调节许多重要的生命过程。随着对多肽结构与功能认识的深入,化学合成多肽在生物医药、生命分析等领域显示了重要价值。人心房钠尿肽(ANP)是一种由28个氨基酸组成的多肽类激素,其含量和代谢异常与心血管疾病、癌症等密切相关。针对ANP重要的生理功能,该文开展了ANP化学合成及其过程的监测与优化,设计了集固相合成线性直链多肽和液相氧化成环为一体的策略。基于高效液相色谱的分离性能和多级质谱的结构鉴定能力,建立了超高效液相色谱-串联质谱(UHPLC-MS/MS)分析新方法,对固相合成产物进行了分离分析,并对液相氧化方法进行了筛选和优化,最终分离纯化得到了目标多肽,为人心房钠尿肽的高效化学合成及氧化成环反应提供借鉴。 相似文献
10.
Determination of ink photoinitiators in packaged beverages by gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry 总被引:2,自引:0,他引:2
Sagratini G Caprioli G Cristalli G Giardiná D Ricciutelli M Volpini R Zuo Y Vittori S 《Journal of chromatography. A》2008,1194(2):213-220
A new analytical method, using gas chromatography-mass spectrometry (GC/MS) and liquid chromatography-mass spectrometry (LC/MS) techniques, was developed for the determination in packaged food beverages of five ink photoinitiator residues: 2-isopropylthioxanthone (ITX), benzophenone, 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB), 1-hydroxycyclohexyl-1-phenyl ketone (IRGACURE 184) and ethyl-4-dimethylaminobenzoate (EDAB). Samples were extracted from selected beverages (milk, fruit juices and wine) and relative packagings, using n-hexane and dichloromethane, respectively, purified on solid-phase extraction (SPE) silica gel cartridges, and then analyzed in GC/MS and LC/MS. The recovery percentages, obtained spiking the beverage samples at concentrations of 4 and 10 microgl(-1) with a standard mixture of photoinitiators, were in the range 42-108% (milk), 50-84% (wine), and 48-109% (fruit juices). The repeatability of the method was assessed in all cases by the % of correlation value, that was lower than 19%. The lowest limits of detection (LODs) and limits of quantification (LOQs), obtained using GC/MS, were in the range 0.2-1 and 1-5 microgl(-1), respectively. The method was applied to the analysis of forty packaged food beverages (milk, fruit juices and wine samples). The most significant contamination was that of benzophenone, found in all samples in a concentration range of 5-217mugl(-1). Its presence was confirmed by an LC/Atmospheric-Pressure PhotoIonization (APPI)/MS/MS analysis. The photoinitiator (EHDAB) was found in eleven out of forty beverages in a concentration range of 0.13-0.8 microgl(-1). Less important was the ITX contamination, found in three out of forty samples in a range 0.2-0.24 microgl(-1). The work proposes a new method to analyze ink photoinitiator residues in polycoupled carton packaging and in contained food beverages. 相似文献
11.
K Ichimura H Yamanaka K Chiba T Shinozuka Y Shiki K Saito S Kusano S Ameniya K Oyama Y Nozaki 《Journal of chromatography. A》1986,374(1):5-16
Until now, there has been little work covering all of the main native adrenal-cortical steroids in blood. We therefore established a method for the simultaneous quantitative measurement of 14 native adrenal-cortical steroids, which involves capillary column gas chromatography-mass spectrometry (GC--MS). Serum steroids were purified from serum with the Extrelut mini-column and then converted into stable derivatives for GC-MS by a combination of boronic cyclization and trimethylsilyl and methyloxime derivatization. The sensitivities (with a signal-to-noise ratio greater than or equal to 7) of our GC-MS method ranged from 0.1 to 1.0 ng/ml of serum, and the coefficients of variation of intra- and inter-assays were less than 19% for each steroid. Our newly devised method involving a capillary column GC-MS system has been proven to be a simple and suitable method for a diagnosis requiring simultaneous detection of many native adrenal steroids in clinical practice. The analysis time is only 4 h. 相似文献
12.
Future potential of targeted component analysis by multidimensional liquid chromatography-mass spectrometry 总被引:1,自引:0,他引:1
Multidimensional liquid chromatography (MDLC) may be used in either (i) the profiling mode where it is the objective to fractionate all components in a mixture or (ii) the targeted component mode in which it is the objective to determine specific analytes. This paper focuses on targeted component analysis from complex mixtures, addressing the critical operations of analyte selection and transport from the first to the second dimension. Although the physical operation of switching a component into the second dimension with computer controlled valving is simple, it is shown that changes in analyte retention time and peak width with column age and fouling are a serious problem. The analyte moves out of the preselected time window for valve switching and quantitation is compromised in the second dimension. It is proposed that a solution to the “drifting peak” phenomenon in targeted component analysis is to use binary mobility elution in the first dimension. Binary mobility refers to those systems, such as affinity chromatography, in which analyte mobility is generally either 0 or 1 relative to mobile phase velocity. Coupling these binary changes in analyte mobility in the first dimension with valve switching eliminates the “drifting peak” phenomenon. In addition, it is shown that a wide time window may be used in affinity separations without compromising the separation or accumulating contaminants. Several cases are described in which immunosorbents were used with reversed phase columns to provide quantitative targeted component analyses from complex mixtures. 相似文献
13.
A rapid and sensitive liquid chromatography-electrospray ionization-mass spectrometry method has been developed for the routine analysis of buprofezin, bupirimate, hexaflumuron, tebufenpyrad, fluvalinate and pyriproxyfen in citrus fruits. Extracts were obtained by matrix solid-phase dispersion (MSPD) using C18 as dispersant and dichloromethane-methanol (80:20, v/v) as eluent. Matrix effects were tested for all matrices by addition of standard to sample blank extracts (samples containing no detectable residues). Mean recoveries obtained at fortification levels between 0.01 and 5 mg kg(-1) were 57-97% with relative standard deviations (RSDs) from 5 to 19%. The limits of quantification (LOQ) were in the range of 0.01-0.2 mg kg(-1) and lower than maximum residue limits (MRLs) established by the Spanish legislation. The MSPD was compared with conventional ethyl acetate extraction, showing equivalent recoveries and precision. Although the sample is more concentrated (5-fold) by solid-liquid extraction (SLE) with ethyl acetate than by MSPD, LOQs obtained by both techniques, were almost equal, because MSPD reduces matrix effects, baseline noise, and interfering peaks from the matrix. The proposed method has been applied to the determination of selected pesticides in real samples. Liquid chromatography-tandem mass spectrometry (LC-MS-MS) with quadrupole ion trap (QIT) and triple quadrupole (TQ) have been used as confirmatory tool for positive samples according to a recent No. SANCO/10476/2003 European Union Guideline. 相似文献
14.
茶叶中的化学成分是构成其风味特征的物质基础。本研究建立了基于气相色谱-质谱联用和液相色谱-质谱联用的非靶向代谢组学方法。完成预处理及分析条件优化后,使用标准样品考察方法的线性、回收率及重复性,结果表明方法整体稳定且结果可靠。将该方法用于绿茶、乌龙茶和红茶中化学成分的分析。通过超声辅助溶剂提取及气相色谱-质谱联用分析共获得1812个特征峰,而使用加热溶剂提取及液相色谱-质谱联用分析可获得2608个特征峰。结合保留规律及质谱数据库,共定性173种化合物(109种随后经标准样品验证),其中只有9种化合物在上述两类分析中被同时检出,表明方法互补性良好。3类茶叶数据的偏最小二乘判别分析结果表明,三者间存在显著差异。结合模型的变量重要因子(VIP)与非参数检验共筛选出90种化合物,其中包含儿茶素、氨基酸、糖、有机酸和黄酮苷类等众多与茶叶滋味密切相关的化学成分。 相似文献
15.
Many environmental samples contain complex mixtures of organic compounds with different sources, polarities and reactivities. This study reports a method for the analysis of both polar/water-soluble and apolar organic compounds in several kinds of environmental samples. The analytical method consists of extraction with a mixture of dichloromethane:methanol (2:1, v/v), silylation using BSTFA (N,O-bis-(trimethylsilyl)trifluoroacetamide) and analysis by gas chromatography-mass spectrometry (GC-MS), a common device in chemical and environmental laboratories. Fifty individual sugar standards, including monosaccharides, sugar alcohols, anhydrosugars, disaccharides and trisaccharides, were analyzed for the determination of their fragmentation patterns and retention times. Recoveries (at three concentrations) and limits of detection (LOD) were determined for a standard mixture containing glucose (monosaccharide), sorbitol (sugar alcohol), levoglucosan (anhydrosugar) and sucrose (disaccharide), and they varied from 68 to 119% and 130 to 360 ng mL(-1), respectively. The method was used for the analysis of aerosol particle, soil and sediment samples, and demonstrated its feasibility in detecting not only several important environmental sugars (e.g., glucose, fructose, inositol, mannitol, sorbitol, levoglucosan, sucrose, mycose), but also a large range of organic compound classes from other polar components (e.g., dicarboxylic acids) to apolar compounds such as n-alkanes. Therefore, the analytical method presented here demonstrated its usefulness for a better understanding of sources and transport of various organic compounds in different environmental compartments. 相似文献
16.
The advantages and technical problems related to the on-line connection of liquid chromatography and mass spectrometry are described, with special emphasis on applications in pharmaceutical chemistry. The most important characteristics of various interfaces, such as direct liquid introduction, Magic, continuous flow fast atom bombardment and thermospray, are discussed. Special applications to the study of thermally very labile compounds are considered. 相似文献
17.
液相色谱-质谱法测定饲料中阿维菌素类药物 总被引:2,自引:0,他引:2
建立了饲料中阿维菌素类药物(阿维菌素、多拉菌素、埃普菌素和伊维菌素)液相色谱-质谱(LC-MS)检测法. 用乙腈提取样品中的药物, 加水稀释, 加三乙胺调节pH, 经C18固相萃取柱净化, LC-MS法测定. 结果表明, 方法平均回收率为91.3%~99.8%, RSD为2.9%~15% (n=4), 配合饲料、浓缩饲料和预混合饲料中的检出限均为10 μg/kg; 定量限均为20 μg/kg. 方法可用于饲料样品中阿维菌素类药物残留量的确证检测. 相似文献
18.
19.
A highly accurate method for measuring pentachlorophenol (PCP) concentrations in textile samples was developed. This highly accurate method for the analysis of textile samples is valuable, given the inherent challenges associated with the complexity of the sample matrix. This method can be applied to certify the concentration of pentachlorophenol in textile CRMs. A measurement procedure based on isotope dilution liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) was developed. Samples were pretreated with acid and then with n-hexane. Excellent precision was obtained. The validated concentration ranges for the method were 1.0-50 ng/g, the LOD was 1.0 ng/g, and the LOQ was 5.0 ng/g. The precision of this method is in the range of 0.80-1.40%. The method can trace to mass. 相似文献
20.
Norisoboldine (NIB) is one of the main bioactive isoquinoline alkaloids in Linderae Radix. A rapid, selective and sensitive method using UPLC‐ESI/MS was first developed for simultaneous determination of NIB and norisoboldine‐9‐O‐α‐glucuronide (NIB‐Glu), its major metabolite in rat plasma. A one‐step protein precipitation with methanol was employed as sample preparation technique. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column (50 × 2.1 mm, i.d. 1.7 µm) with a gradient mobile phase consisting of acetonitrile and water containing 0.1% formic acid. Detection and quantification were performed using a quadrupole mass spectrometer by selective ion reaction‐monitoring mode. Good linearity was achieved using weighted (1/x2) least squares linear regression over the concentration ranges 0.01–2 µg/mL for NIB and 0.025–25 µg/mL for NIB‐Glu. The lower limit of quantification of NIB and NIB‐Glu was 0.01 and 0.025 µg/mL, respectively. The intra‐ and inter‐day precisions (relative standard deviations) of the assay at all three quality control levels were 4.6–14.1% for NIB, and 5.0–12.2% for NIB‐Glu. The accuracies (relative error) were −13.5–8.1% for NIB and −12.8–7.6% for NIB‐Glu, respectively. This developed method was successfully applied to an in vivo pharmacokinetic study in rats after a single intravenous dose of 10 mg/kg NIB. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献