首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
李海静  刘国柱  张香文 《色谱》2018,36(8):780-785
采用全二维气相色谱-质谱联用(GC×GC-MS)考察了色谱柱系统、程序升温条件和调制周期3个主要因素对样品组分分离结果的影响,建立了煤油基吸热型碳氢燃料烃族组成的定性分析方法,并利用GC×GC-FID通过有效碳数校正因子对烃族组成进行定量。对选取的9种燃料的分析结果表明,该方法对链烷烃和环烷烃的定量结果与标准方法ASTM D2425的结果高度一致,相对误差基本均在±10%以内。利用该方法计算的碳含量结果与元素分析法相比误差均在0.5%以下。该方法无需复杂的前处理,稀释后可直接进样分析,操作简单,而且可直观地看出不同样品之间的差异,为改进燃料的性能提供了必要的分析手段。  相似文献   

2.
Multidimensional gas-chromatographic analyses of olesochemically based nonionic, anionic and several cationic surfactants in industrial cleaners are demonstrated. Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry allows the simultaneous determination of fatty alcohols, fatty alcohol sulphates and alkyl polyglucosides. In addition, the determination of fatty alcohol ethoxylates up to C10EO8 (highest degree of ethoxylation) and C18EO5 (longest C-chain at an ethoxylation degree of five) and the analysis of fatty alcohol alkoxylates that contain ethoxy (EO) and propoxy (PO) groups could be realized. Because of decomposition in the injector and a weak EI-fragmentation, cationic surfactants such as alkyl benzyl dimethyl ammonium chloride could also be identified by their characteristic fragments. Thermogravimetric analyses confirmed that the temperature in a normal GC injector is not high enough to cause thermal decomposition of esterquats. However, we could demonstrate that a modified silylation procedure forms decomposition products of esterquats in the GC injector which are detectable by GC × GC–(TOF)MS and allows the identification of such GC-atypical analytes.  相似文献   

3.
Multidimensional gas-chromatographical analysis of various tensides of natural or synthetic origin in cosmetic products is demonstrated. Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry allows the qualitative and quantitative determination of alkyl polyglucosides (AG), fatty alcohol ethoxylates (FAEO), fatty alcohol sulfates (FAS), fatty alcohol ether sulfates (FAES) and cocamidopropyl betaines (CAPB) in shower gel and cleaning agents. The samples were aliquoted in two parts. The first part was silylated, diluted and analysed; then, in order to detect anionic tensides (FAES, FAS) too, the second aliquot was hydrolysed before being silylated for analysis. Because of their amphoteric character, the betaines can only be analysed by gas chromatography after thermal decomposition in the injector, which leads to the corresponding amidoamines among other products.  相似文献   

4.
Guo K  Zhou J  Liu Z 《色谱》2012,30(2):128-134
通过对升温速度、二维补偿温度、调制周期等关键实验参数的优化,建立了全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)分析重馏分油中芳烃组分的方法,得到了重馏分油芳烃组分按环数分布的二维点阵图。根据谱库检索、标准化合物对照及文献报道,对重馏分油芳烃组分中菲、甲基菲及芘、苯并蒽等常见多环芳烃(PAH)进行了准确定性,并将该方法应用到重馏分油加氢处理工艺研究中,对菲、芘的加氢处理产物进行了定性分析。该研究为重馏分油芳烃组分的准确定性提供了新的技术手段,为加深对油品加氢规律的认识提供了技术支持。全二维气相色谱与普通一维色谱对比,在重馏分油的芳烃组分分析上体现了极大优势。  相似文献   

5.
Most lipids are a complex mixture of classes of compounds such as fatty acids, fatty alcohols, diols, sterols and hydroxy acids. In this study, the suitability of comprehensive two-dimensional gas chromatography coupled to a time-of-light mass spectrometer is studied for lipid characterization in complex samples. With lanolin, a refined wool wax, as test sample, it is demonstrated that combined methylation plus silylation is the preferred derivatization procedure to achieve (i) high-quality GC x GC separation and (ii) easily recognizable ordered structures in lipid analysis. Optimization of the GC x GC column combination, the influence of the temperature programme on the quality of the separation, and the potential and limitations of automated TOF-MS-based identification are discussed. The combined power of a 2D separation, ordered structures and MS detection is illustrated by the identification of several minor sample constituents.  相似文献   

6.
牛鲁娜  刘泽龙  周建  蔡新恒  田松柏 《色谱》2014,32(11):1236-1241
建立了全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)分析柴油馏分中饱和烃的分子组成的方法。结合谱库检索、质谱图解析、沸点与分子结构关系和全二维谱图特征,定性(或归类)了焦化柴油饱和烃组分中1057个化合物单体,其中正构烷烃排列规律性最强,一环~三环环烷烃按照极性和沸点的差异呈瓦片状分布在其上方。另外,还准确区分了在一维气相色谱上共流出的正构烷基环己烷和正构烷基环戊烷,以及正构 α 单烯烃。根据质谱采集的总离子流色谱图,采用峰面积归一化法得到了饱和烃组分的碳数分布结果,并将该方法应用于研究不同类型柴油馏分饱和烃的分子组成特点。结果表明,催化裂化和焦化柴油馏分饱和烃组分的化合物类型和分布各不相同。分子组成分析能为油品加工工艺机理的研究提供方法支持。  相似文献   

7.
A method for the analysis of chlorinated and brominated polycyclic aromatic hydrocarbon (Cl-/Br-PAHs) congeners in environmental samples, such as a soil extract, by comprehensive two-dimensional gas chromatography coupled to a high resolution time-of-flight mass spectrometry (GC×GC-HRTOF-MS) is described. The GC×GC-HRTOF-MS method allowed highly selective group type analysis in the two-dimensional (2D) mass chromatograms with a very narrow mass window (e.g. 0.02Da), accurate mass measurements for the full mass range (m/z 35-600) in GC×GC mode, and the calculation of the elemental composition for the detected Cl-/Br-PAH congeners in the real-world sample. Thirty Cl-/Br-PAHs including higher chlorinated 10 PAHs (e.g. penta, hexa and hepta substitution) and ClBr-PAHs (without analytical standards) were identified with high probability in the soil extract. To our knowledge, highly chlorinated PAHs, such as C(14)H(3)Cl(7) and C(16)H(3)Cl(7), and ClBr-PAHs, such as C(14)H(7)Cl(2)Br and C(16)H(8)ClBr, were found in the environmental samples for the first time. Other organohalogen compounds; e.g. polychlorinated biphenyls (PCBs), polychlorinated naphthalenes (PCNs), and polychlorinated dibenzofurans (PCDFs) were also detected. This technique provides exhaustive analysis and powerful identification for the unknown and unconfirmed Cl-/Br-PAH congeners in environmental samples.  相似文献   

8.
In this paper several characteristic features of time-of-flight mass spectrometry in coupling with gas chromatography are demonstrated and the parameters are compared to quadrupole mass analyzer. In the second part, the comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry was applied in human metabolomic field, particularly in the determination of pathological markers of Inherited Metabolic Disorders (IMDs).  相似文献   

9.
A technique using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOFMS) is applied to a qualitative analysis of three sample extracts from hair suspected of containing various drug compounds. The samples were also subjected to a quantitative target analysis for codeine, morphine, 6-monoacetylmorphine (6-MAM), amphetamine, methamphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethylamphetamine (MDMA), methadone, and benzylpiperazine (BZP) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). GC × GC/TOFMS provided a non-specific procedure that identified various drugs, metabolites, and impurities not included in the target analysis. They included cocaine, diazepam, and methaqualone (quaalude). Comprehensive GC × GC separation was achieved using twin-stage cryo-modulation to focus eluant from a DB-5ms (5% phenyl) to a BPX50 (50% phenyl) GC column. The TOF mass spectrometer provided unit mass resolution in the mass range m/z 5–1000 and rapid spectral acquisition (≤500 spectra/s). Clean mass spectra of the individual components were obtained using mass spectral deconvolution software. The ‘unknown’ components were identified by comparison with mass spectra stored in a library database.  相似文献   

10.
Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC–TOFMS) is a well-established instrumental platform for complex samples. However, chemometric data analysis is often required to fully extract useful information from the data. We demonstrate that retention time shifting from one modulation to the next, Δ2tR, is not sufficient alone to quantitatively describe the trilinearity of a single GC × GC–TOFMS run for the purpose of predicting the performance of the chemometric method parallel factor analysis (PARAFAC). We hypothesize that analyte peak width on second dimension separations, 2Wb, also impacts trilinearity, along with Δ2tR. The term trilinearity deviation ratio, TDR, which is Δ2tR normalized by 2Wb, is introduced as a quantitative metric to assess accuracy for PARAFAC of a GC × GC–TOFMS data cube. We explore how modulation ratio, MR, modulation period, PM, temperature programming rate, Tramp, sampling phase (in-phase and out-of-phase), and signal-to-noise ratio, S/N, all play a role in PARAFAC performance in the context of TDR. Use of a PM in the 1–2 s range provides an optimized peak capacity for the first dimension separation (500–600) for a 30 min run, with an adequate peak capacity for the second dimension separation (12–15), concurrent with an optimized two-dimensional peak capacity (6000–7500), combined with sufficiently low TDR values (0–0.05) to facilitate low quantitative errors with PARAFAC (0–0.5%). In contrast, use of a PM in the 5 s or greater range provides a higher peak capacity on the second dimension (30–35), concurrent with a lower peak capacity on the first dimension (100–150) for a 30 min run, and a slightly reduced two-dimensional peak capacity (3000–4500), and furthermore, the data are not sufficiently trilinear for the more retained second dimension peaks in order to directly use PARAFAC with confidence.  相似文献   

11.
Organic acidurias are a large group of inherited metabolic disorders (IMDs), commonly diagnosed by GC-MS analysis of organic acids in urine after acidic extraction and trimethylsilylation. In this study, a GC×GC-ToF-MS method has been optimized for the analysis of pathological metabolites in urine. An automated data processing strategy based on the use of mass spectra and GC retention times for the target search and quantification of pathological metabolites has been developed. Using this procedure, each unknown sample is automatically examined for the presence of markers of several diseases at the same time. The method has been applied for the analysis of 6 challenging proficiency testing samples from patients with IMDs (thymidine phosphorylase deficiency, mevalonic aciduria, hawkinsinuria, aromatic l-amino acid decarboxylase deficiency, propionic acidemia and medium-chain acyl-CoA dehydrogenase deficiency). Using the GC×GC-ToF-MS method, we were able to determine complete sets of markers for all the IMDs. The quality of the mass spectral matches for the pathological markers was higher than 800 (out of 1000).  相似文献   

12.
Pyrolysis oils have attracted a lot of interest, as they are liquid energy carriers and general sources of chemicals. In this work, gas chromatography with flame ionization detector (GC-FID) and two-dimensional gas chromatography with time-of-flight mass spectrometry (GC×GC-TOFMS) techniques were used to provide both qualitative and quantitative results of the analysis of three different pyrolysis oils. The chromatographic methods and parameters were optimized and solvent choice and separation restrictions are discussed. Pyrolysis oil samples were diluted in suitable organic solvent and were analyzed by GC×GC-TOFMS. An average of 300 compounds were detected and identified in all three samples using the ChromaToF (Leco) software. The deconvoluted spectra were compared with the NIST software library for correct matching. Group type classification was performed by use of the ChromaToF software. The quantification of 11 selected compounds was performed by means of a multiple-point external calibration curve. Afterwards, the pyrolysis oils were extracted with water, and the aqueous phase was analyzed both by GC-FID and, after proper change of solvent, by GC×GC-TOFMS. As previously, the selected compounds were quantified by both techniques, by means of multiple point external calibration curves. The parameters of the calibration curves were calculated by weighted linear regression analysis. The limit of detection, limit of quantitation and linearity range for each standard compound with each method are presented. The potency of GC×GC-TOFMS for an efficient mapping of the pyrolysis oil is undisputable, and the possibility of using it for quantification as well has been demonstrated. On the other hand, the GC-FID analysis provides reliable results that allow for a rapid screening of the pyrolysis oil. To the best of our knowledge, very few papers have been reported with quantification attempts on pyrolysis oil samples using GC×GC-TOFMS most of which make use of the internal standard method. This work provides the ground for further analysis of pyrolysis oils of diverse sources for a rational design of both their production and utilization process.  相似文献   

13.
Oil-sand naphthenic acids (NAs) are organic wastes produced during the oil-sand digestion and extraction processes and are very difficult to separate and analyze as individual components due to their complex compositions. A comprehensive two-dimensional gas chromatography/time of flight mass spectrometry (GC x GC/TOF-MS) system was applied for the characterization of two commercial mixtures of naphthenic acids (Fluka and Acros) and a naphthenic acid sample extracted from the Syncrude tailings. Contour plots of chromatographic distributions of different Z homologous series of the Fluka, Acros and Syncrude NAs were constructed using fragment ions that were characteristic of the NA's molecular structures. Well-ordered patterns were observed for NAs of Z= 0 and -2 which corresponded to acyclic acids and monocyclic acids, respectively. For NAs of Z= -4, -6, and -8, specific zones were observed which would allow the pattern recognition of these NAs obtained from different origins. As expected, gas chromatographic retention times increase with the number of the carbons and the number of rings in the molecules. Little signal was obtained for NAs with Z numbers of -10, or lower. Deconvoluted mass spectra of various NA isomers were derived from the reconstructed GC x GC chromatogram, permitting detailed structural elucidations for NAs in the future. The current study demonstrated that the combination of GC x GC and the TOF-MS is a powerful to identify origins of the NAs in an effective manner. GC x GC/TOF-MS alone, however, may not be enough to characterize each individual isomer in a complex mixture such as NAs. The use of mass deconvolution software followed by library search have thus become necessary to separate and study the mass spectrum of each individual NA component, allowing a detailed identification of the toxic components within the NAs mixture.  相似文献   

14.
Comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was used for the characterization of aromatic compounds present in extra heavy gas oil (EHGO) from Brazil. Individual identification of EHGO compounds was successfully achieved in addition to group-type separation on the chromatographic plane. Many aromatic hydrocarbons, especially polycyclic aromatic hydrocarbons and sulfur compounds, were detected and identified, such as chrysenes, phenanthrenes, perylenes, benzonaphthothiophenes and alkylbenzonaphthothiophenes. In addition, triaromatic steroids, methyl-triaromatic steroids, tetrahydrochrysenes and tetraromatic pentacyclic compounds were present in the EHGO aromatic fractions. Considering the roof-tile effect observed for many of these compound classes and the high number of individual compounds identified, GC×GC-TOFMS is an excellent technique to characterize the molecular composition of the aromatic fraction from EHGO samples. Moreover, data processing allowed the quantification of aromatic compounds, in class and individually, using external standards. EHGO data were obtained in μgg(-1), e.g., benzo[a]pyrene were in the range 351 to 1164μgg(-1). Thus, GC×GC-TOFMS was successfully applied in EHGO quantitative analysis.  相似文献   

15.
Comprehensive two-dimensional gas chromatography (GC x GC) coupled to time-of-flight mass spectrometry (TOF-MS) was applied to improve the separation of 4-nonylphenol isomers and their biodegradation products. The structurally similar nonylphenol isomers were separated by combining a 30 m long semi-polar column and a short polar capillary. Both were coupled via a custom-made liquid nitrogen cryogenic modulator. The advanced GC resolution of coeluting isomers, additionally supported by fast scanning TOF-MS, provided clearer, non-interfered mass spectra of individual isomers. Thus, identification of components is facilitated as shown for isomeric 4-nonylphenols and metabolites of their biodegradation by Clavariopsis aquatica, an aquatic fungus. GC x GC-TOF-MS analysis enabled the separation of about 40 alkylphenol isomers included in technical 4-nonylphenol. During biodegradation the variety of emerging compounds increased with longer reaction time. The comprehensive analysis indicated a broad spectrum of hydroxylated, carboxylated nonylphenolisomers and additionally, chlorinated aromatic compounds produced and released from the fungal culture.  相似文献   

16.
Pierce KM  Schale SP 《Talanta》2011,83(4):1254-1259
The percent composition of blends of biodiesel and conventional diesel from a variety of retail sources were modeled and predicted using partial least squares (PLS) analysis applied to gas chromatography-total-ion-current mass spectrometry (GC-TIC), gas chromatography-mass spectrometry (GC-MS), comprehensive two-dimensional gas chromatography-total-ion-current mass spectrometry (GCxGC-TIC) and comprehensive two-dimensional gas chromatography-mass spectrometry (GCxGC-MS) separations of the blends. In all four cases, the PLS predictions for a test set of chromatograms were plotted versus the actual blend percent composition. The GC-TIC plot produced a best-fit line with slope = 0.773 and y-intercept = 2.89, and the average percent error of prediction was 12.0%. The GC-MS plot produced a best-fit line with slope = 0.864 and y-intercept = 1.72, and the average percent error of prediction was improved to 6.89%. The GCxGC-TIC plot produced a best-fit line with slope = 0.983 and y-intercept = 0.680, and the average percent error was slightly improved to 6.16%. The GCxGC-MS plot produced a best-fit line with slope = 0.980 and y-intercept = 0.620, and the average percent error was 6.12%. The GCxGC models performed best presumably due to the multidimensional advantage of higher dimensional instrumentation providing more chemical selectivity. All the PLS models used 3 latent variables. The chemical components that differentiate the blend percent compositions are reported.  相似文献   

17.
A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GC/MS) and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC × GC/TOFMS), respectively. In the GC/MS analysis, serially coupled columns were used. By comparing the GC/MS results with GC × GC/TOFMS results, many more components in the essential oil could be found within the two-dimensional separation space of GC × GC. The quantitative determination of components in the essential oil was performed by GC × GC with flame ionization detection (FID), using a method of multiple internal standards calibration.  相似文献   

18.
A simple and fast solid-phase microextraction method coupled with comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry was developed for analysis of polycyclic aromatic hydrocarbons in edible oil, performed directly in a hexane solution of the oil. Sampling conditions (solvent used, extraction time, extraction temperature and fiber rinsing time) were optimized by using a sample of oil fortified with a standard solution of polycyclic aromatic hydrocarbons. The method was validated by calculating linear range, correlation coefficient, accuracy, repeatability, detection limit and quantification limit. The method was applied to several oils collected from the market and directly from an olive pomace extraction plant.  相似文献   

19.
Zhang J  Hu H  Gao M  Yang P  Zhang X 《Electrophoresis》2004,25(14):2374-2383
A comprehensive two-dimensional capillary liquid chromatography and capillary zone electrophoresis system coupled with tandem matrix assisted laser desorption/ionization-time of flight-time of flight-mass spectrometry (MALDI-TOF-TOF-MS) proteomics analyzer is presented. Protein/peptide samples were separated by capillary high-performance liquid chromatography (cHPLC). The effluents from cHPLC (the first dimension) were continuously transferred into capillary zone electrophoresis (CZE, the second dimension) through a novel valve-free hydrodynamic sampling interface. The CZE effluents were mixed with alpha-cyano-4-hydroxycinnamic acid (CHCA) matrix sheath flow via CE-MALDI interface, and then directly deposited on the MALDI target at a 3 s time-interval for further MS analysis. The high efficiency of the overall system was demonstrated by analysis of proteins in D20 (human hepatocellular carcinoma model in nude mice with high metastatic potential) liver cancer tissue. More than 300 proteins were identified, which proved the system potential for high-throughput analysis and application in proteomics.  相似文献   

20.
Soft laser photo-ionization mass spectrometry is presented as a separation dimension hyphenated with gas chromatographic techniques. Single photon ionization (SPI) is a universal soft ionization method which ionizes organic molecules with an ionization potential below 10.5 eV if 118 nm laser radiation is used. The inherently soft ionization of photo ionization techniques can further be utilized together with gas chromatography as a comprehensive two-dimensional separation method (GC x MS), using the GC retention time as first separation dimension and the molecular mass as second separation dimension. Some GC x MS chromatograms of diesel petroleum samples using SPI are presented and discussed. Finally, it is demonstrated that the coupling of soft SPI mass spectrometry with comprehensive two-dimensional gas chromatography (GC x GC) provides a three-dimensional separation technique (GC x GC x SPI-MS).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号