首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 18 毫秒
1.
Methodology based on the cloud-point phenomenon was applied to the comparative study of 3 different polyoxyethylene nonionic surfactants in order to extract and preconcentrate a group of phenolic derivatives in water samples; these phenolic compounds, which were determined by liquid chromatography with UV detection, included 11 pollutants given priority by the U.S. Environmental Protection Agency. The optimum conditions for the extraction and preconcentration of phenolic compounds were established for each surfactant. The surfactant that gave the best extraction and preconcentration of the analytes under study was polyoxyethylene 6 lauryl ether (C12E6) with detection limits of <3.5 microg/L for all the phenolic compounds tested. The method was applied to seawater and depurated wastewater samples.  相似文献   

2.
Fast determination of tetrafluoroborate by high-performance liquid chromatography using a silica-based monolithic column and direct conductivity detection was carried out. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e column (50 mm x 4.6 mm i.d.) with tetrabutylammonium hydroxide (TBA-OH)+ phthalic acid as eluent. The effects of eluent concentration, eluent pH, column temperature and flow rate on retention time of tetrafluoroborate were investigated. The optimized chromatographic conditions for determination of tetrafluoroborate were using 0.5mM TBA-OH + 0.31 mM phthalic acid (pH 5.5) as eluent, column temperature of 30 degrees C and flow rate of 6.0 mL/min. Retention time of tetrafluoroborate was less than 1min under the conditions. Common anions (Cl(-), Br(-), NO3(-) and SO4(2-)) did not interfere with the determination of tetrafluoroborate. Detection limit (S/N = 2) for tetrafluoroborate was 1.4 mg/L. The linear range of calibration curve between peak area and the concentration of tetrafluoroborate was from 1.4 to 100.0 mg/L. The reproducibility was 0.09% and 1.8% (n = 5) relative standard deviation (RSD) for retention time and peak area, respectively. The method has been applied to the determination of tetrafluoroborate in ionic liquids. Recoveries of tetrafluoroborate after spiking were 98.2-101.5%.  相似文献   

3.
The analysis of illicit heroin and opium samples on a coupled alumina and C18 column system is described. The compounds to be analysed can be divided into two groups: those with low pKa values, such as caffeine, papaverine and noscapine, and those with high pKa values, such as heroin, acetylcodeine, O6-monoacetylmorphine, procaine, codeine, morphine and strychnine. The first group can best be separated on a C18 column, whereas alumina is more suitable for the second group. Previously reported criteria for choosing proper buffer systems for ion-exchange separations on alumina were used together with an iterative regressive optimization procedure developed in our laboratory. The system can be used with and without valve-switching, depending on the sample type. The peak purity of the judicially important components heroin and O6-monoacetylmorphine has been checked with a photodiode array detector and by use of advanced software.  相似文献   

4.
A LC method for corticosteroids (CC) determination in poultry feed using a Chromolith column and UV detection has been developed and validated. The method development involved the optimization of different hydro-organic mobile phases using methanol or ACN as organic modifiers, flow rate, and temperature. The optimum separation was achieved at 40 degrees C using ACN/water (21:79 v/v) as mobile phase and 3 mL/min flow rate, allowing the separation to baseline of four out of seven CC in about 10 min. Prior to LC, a sample preparation procedure previously assayed for anabolics was used. It includes a leaching process, saponification of the esters from fatty acids, and SPE. Method validation was carried out according to the EU criteria established for quantitative screening methods. The extraction efficiencies, decision limits (CCalpha), and detection capabilities (CCbeta) for these compounds were in the ranges of 86-92%, 27-36 microg/kg, and 33-43 microg/kg, respectively. The repeatability and the within-laboratory reproducibility at 1, 1.5, and 2 CCbeta concentration levels were smaller than 9.0, 5.0, and 4.2% and 9.4, 6.4, and 4.9%, respectively. The CV values of the robustness test were less than 3.8% and the accuracy was in the range of 98-103%. The proposed method was applied to other feed with satisfactory results.  相似文献   

5.
Ex vivo placental perfusion experiments are important in understanding the quantity and mechanisms of xenobiotic transport to the fetus during pregnancy. Our study demonstrates that paclitaxel and antipyrine concentrations in placental perfusion medium containing physiological concentrations of human serum albumin during pregnancy (30?mg/mL) can be quantified by RP-HPLC and UV detection. A liquid-liquid extraction method was developed for the quantification of paclitaxel and celecoxib (internal standard) from perfusion medium. Antipyrine, which is a necessary marker in placental perfusions for determining the validity of experiments and calculating the clearance index of xenobiotics, was also analyzed by HPLC and UV detection. Antipyrine concentrations were determined by HPLC after precipitating the perfusion medium in acetonitrile and separating the precipitated proteins by centrifugation. Concentrations were fitted to linear regressions with R2 values approaching 1. Lower limits of detection for paclitaxel and antipyrine were 100?ng/mL and 200?ng/mL, respectively. Both methods demonstrated high intra-day and inter-day precision and trueness. Additionally, the use of these methods was demonstrated in a placental perfusion experiment using Taxol® (paclitaxel dissolved in Cremophor-EL). The fetal transfer rate of Taxol was 6.6% after 1 hour.  相似文献   

6.
A high sensitivity, multichannel fluorescence detector with small volume has been developed for capillary column liquid chromatography. Using an intensified linear photodiode array to monitor fluorescence emission, several important mixtures exhibiting native fluorescence have been examined following high efficiency separation on a capillary column. By correlating mass spectral, fluorescence spectral, and retention time data, information of potential utility in the structural elucidation of aromatic molecules contained in complex mixtures can be obtained. Examples include the separation and spectral examination of the polyaromatic compounds in samples of both biological and environmental interest.  相似文献   

7.
Usnic acid, a lichen substance, has a wide range of pharmaceutical applications, including antibiotic, antimycotic, antifeedant, antitubercular, antitumor, and analgesic activities. Some products containing usnic acid are marketed as weight control supplements; however, hepatotoxicity and acute liver failures were reported as severe side effects. The usnic acid content present in the plant materials and market products was analyzed by reversed-phase high-pressure liquid chromatography with a photodiode array detector at 233 nm. A Waters XTerra RP18 (150 x 4.6 mm; 5 microm particle size) column was the stationary phase; mobile phase was aqueous 0.1% acetic acid and acetonitrile gradient at flow rate of 1.0 mL/min. The temperature was held constant at 30 degrees C. The retention time of usnic acid was approximately 13.3 min. Acetone extraction of the samples took place with sonication. The precision of the method was confirmed by a standard deviation below 3.0% (n=3) and usnic acid recovery was 99.0%. Limit of detection was 0.4 microg/mL and the response was linear from 1.4 to 570.0 microg/mL with a correlation coefficient (R2) of 0.9991. The content of usnic acid in 4 raw materials and 22 finished products was analyzed.  相似文献   

8.
A method termed as liquid-liquid-liquid microextraction was utilized to extract chlorophenols from water. The extracted chlorophenols, present in anionic form, were then separated, identified, and quantitated by ion-pair high-performance liquid chromatography with photodiode array detection (HPLC/DAD). For trace chlorophenol determination using HPLC/DAD, the chlorophenolate anion provides a better ultraviolet spectrum for quantitative and qualitative analyses than does uncharged chlorophenol. This is due to the auxochromic effect of the phenolate anion. In the study, experimental conditions such as organic phase identity, acceptor phase volume, sample agitation, extraction time, acceptor phase NaOH concentration, donor phase HCl concentration, salt addition, and UV absorption wavelength were optimized. Relative standard deviations (RSD, 2.3-5.4%), coefficients of determination (r2 0.9994-0.9999), and detection limits (0.049-0.081 ng mL(-1)) of the proposed method were investigated under the selected conditions. The method was successfully applied to analyses of reservoir and tap water samples, and the relative recoveries of chlorophenols from the spiked reservoir and tap water samples were 94.1-100.4% and 87.8-101.2%, respectively. The proposed method is capable of identifying and quantitating each analyte to 0.5 ng mL(-1), confirming the HPLC/DAD technique to be quite robust for monitoring trace levels of chlorophenols in water samples.  相似文献   

9.
A multiresidue HPLC method for identification and quantification of the synthetic acaricides fluvalinate, coumaphos, bromopropylate and its metabolite 4,4′-dibromobenzophenone in beeswax has been developed. Different techniques were tested and modified. The method consists of a sample preparation with isooctane followed by solid phase extraction using Florisil columns. Determination of the synthetic acaricides is achieved by HPLC with a photodiode array detector. Analytical performance of the proposed method, including sensitivity, accuracy and precision was satisfactory. The LOD for the analytes varied between 0.1 and 0.2 μg g−1 wax and the recoveries between 70 and 110%. Relative standard deviation of the repeatability of the method is <15% and reproducibility is <31%.  相似文献   

10.
A new method, which involves liquid-phase microextraction (LPME) followed by high performance liquid chromatography (HPLC) with diode array detector (DAD), was developed to determine phoxim in water sample. Experimental parameters affecting the extraction efficiency, such as extraction solvent, solvent volume, agitation speed of the sample and extraction time were investigated. Under the optimal extraction conditions, phoxim was found to yield a good linear calibration curve in the concentration range from 0.01 to 5 μg mL−1. The limit of detection (LOD) is 10 ng mL−1, and relative standard deviation (RSD) at the 100 ng mL−1 levels is 8.4%. Lake water and tap water samples were successfully analyzed using the proposed method.  相似文献   

11.
A high‐performance liquid chromatography coupled with photodiode array detection and electrospray ionization tandem mass spectrometry (HPLC‐PAD‐ESI‐MSn) method was developed to evaluate the quality of Hpericum japomicum through establishing chromatographic fingerprint and simultaneous determination of seven phenolic compounds. The analysis was achieved on an Ultimate XB‐C18 analytical column (250 mm × 4.6 mm i.d., 5 µm) using an aqueous solution of acetic acid (pH 3.8) and methanol as the mobile phase. Ten samples of H. japomicum from various habitats were investigated and the correlation coefficients of similarity were determined from the HPLC fingerprints. By using an online ESI‐MSn, 20 common peaks in chromatographic fingerprints were identified as phenols, including flavones and their glycosides, flavonones and their glucosides, flavanols, xanthones, phloroglucinols, phenyl propanoids and chromones. Based on the above study, seven phenols which are considered to be major constituents in H. japomicum, including 3,4‐dihydroxybenzoic acid (1), taxfolin‐7‐O‐α‐l ‐rhamnoside (7), 7‐dihydroxy‐2‐(1‐methylpropyl)chromone‐8‐β‐d ‐glucoside (8), isoquercitrin (14), quercitrin (16), quercetin‐7‐O‐α‐l‐ rhamnoside (18) and quercetin (19) were quantified by the validated HPLC‐PAD method. This developed method by combination of chromatographic fingerprint and quantification analysis could be applied to control the quality of H. japomicum. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
An analytical method for the determination of trace levels of six different nonsteroidal antiinflammatory drugs (NSAIDs) in water samples has been developed and validated. Environmentally relevant pharmaceuticals were chosen according to human consumption in Poland. Final analysis of the target compounds was performed by RP LC-diode-array detection-MS, whereas sample preparation included an SPE step. For this SPE step, a number of packing materials, such as LiChrolut RP-18, calixarene, Strata-X, BAKERBOND Narc-2, BAKERBOND Polar Plus, BAKERBOND styrene divinylbenzene-1, and Discovery DSC-18, were used, and their respective advantages and disadvantages in this study were discussed. The RP-18 phase was found to be the most retentive for all analytes. The detection limits for compounds in surface waters were varied from 0.005 for diflunisal to 0.095 microg/L for ibuprofen. The average recoveries of NSAIDs from the surface water samples ranged from 80 up to 103%. RSD value is relatively low (from 4% for fenoprofen up to 8% for ibuprofen). The performance of the method was tested with several environmental water samples.  相似文献   

13.
Liu Y  Yu H  Li S 《色谱》2011,29(10):1036-1040
建立了整体柱离子对色谱-直接电导检测快速测定微量碘酸根的方法.采用反相硅胶整体柱,以氢氧化四丁铵(TBA)-邻苯二甲酸-水-乙腈水溶液为淋洗液,分别讨论了淋洗液、流速及柱温对碘酸根保留的影响,并确定最佳色谱条件为:以0.25 mmol/L TBA-0.18 mmol/L邻苯二甲酸-3%乙腈(pH 5.5)水溶液为淋洗液...  相似文献   

14.
A silica monolithic capillary column was linked to an open capillary of the same internal diameter via a Teflon sleeve to form a duplex column to investigate the combination of chromatography and electrophoresis in the mode of electrically assisted capillary liquid chromatography (eCLC). Using a commercial CE instrument with an 8.5 cm long, 100 μm i.d. reversed phase silica monolithic section and a window 1.5 cm beyond the end of this in a 21.5 cm open section, a minimum plate height of 9 μm was obtained in capillary liquid chromatography (CLC) mode at a low driving pressure of 50 psi. In eCLC mode, high speed and high resolution separations of acidic and basic compounds were achieved with selectivity tuning based on the flexible combination of pressure (0–100 psi) and voltage. Taking advantage of the excellent permeability of silica monolithic columns, use of a step flow gradient enabled elution of compounds with different charge state.  相似文献   

15.
Yoshioka N  Ichihashi K 《Talanta》2008,74(5):1408-1413
Forty synthetic food colors were determined in drinks and candies by reversed-phase high-performance liquid chromatography with photodiode array detection. The following food colors were analyzed within 19 min using a short analytical column (50 mm × 4.6 mm i.d., 1.8 μm) at 50 °C with gradient elution: Ponceau 6R, Tartrazine, Fast yellow AB, Amaranth, Indigotine, Naphthol yellow S, Chrysoine, Ponceau 4R, Sunset yellow FCF, Red 10B, Orange G, Acid violet 7, Brilliant black PN, Allura red AC, Yellow 2G, Red 2G, Uranine, Fast red E, Green S, Ponceau 2R, Azorubine, Orange I, Quinoline yellow, Martius yellow, Ponceau SX, Ponceau 3R, Fast green FCF, Eosine, Brilliant blue FCF, Orange II, Orange RN, Acid blue 1, Erythrosine, Amido black 10B, Acid red 52, Patent blue V, Acid green 9, Phloxine B, Benzyl violet 4B, and Rose bengal. The recoveries of these compounds added to soft drinks and candies at 5 μg/g ranged from 76.6 to 115.0%, and relative standard deviations (R.S.D.s) were within 6.0%. The limits of detection and the limits of quantitation were 0.03 and 0.1 μg/g, respectively.  相似文献   

16.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

17.
An HPLC-DAD method for determining corticoids in calf feed and in animal feeding water samples using a monolithic column has been developed and validated. The method optimization included the study of binary mobile phases of water and acetonitrile. The optimum separation was achieved at 40 °C, with acetonitrile:H2O 29:71 v/v used as mobile phase and a 3 ml/min flow-rate, which resulted in their separation in about 5 min. Two reported sample procedures were applied to feed and for animal feeding water samples prior to HPLC. Method validation was carried out according to the EU criteria established for quantitative screening methods. The results indicate that this method is highly specific, reproducible and accurate. The proposed method was found to be robust and unaffected by small variations in the extraction procedure and in HPLC conditions. The developed method for the determination of corticoids in feed and water samples was also found to be suitable for different kinds of feeds and waters.  相似文献   

18.
A polyacrylamide gel crosslinked with allyl-β-cyclodextrin can be used repeatedly for several weeks for the separation of DNA fragments, since bubbles are not generated during a run. Allyl-β-cyclodextrin can easily be synthesized in one step from allylglycidylether and β-cyclodextrin. The plate numbers for DNA fragments, up to about 1500 bp, are high: for the separation of pBR322/HaeIII fragments they were in the range 450 000–1 600 000 m−1. The resolution was almost independent of the concentration of the crosslinker (allyl-β-cyclodextrin) — in sharp contrast to gels crosslinked with N,N′-methylenebisacrylamide.  相似文献   

19.
Yazdi AS  Es'haghi Z 《Talanta》2005,66(3):664-669
Liquid-liquid-liquid phase microextraction (LLLME) coupled with high-performance liquid chromatography (HPLC) for the analysis of some aromatic amines is described. These compounds were extracted from 4.0 mL aqueous sample that adjusted to pH 13 with, NaOH-NaCl buffer solution (donor phase, P1) into an organic phase (P2) 150 μl benzyl alcohol and ethyl acetate (2:1) and then back extracted into a microdrop of aqueous acceptor phase (P3), adjusted at pH 2, with Na2HPO4-H3PO4 buffer solution. The extraction time, T1 (from P1 to P2) was 20 min and T2 (from P2 to P3) was 1 min. Different crown ethers as complexing agents for amines were added to the acceptor phase to improve the extraction time. Factors such as organic solvents, extraction times, and addition of crown ethers to acceptor phase and stirring rate were optimised. The method was applied for determination of aromatic amines in wastewater samples. Enrichment factors ranged from 184.5 to 389.7. The linearity range was from 3 to 1000 ng/ml and the detection limits varied from 0.8 to 1.80 ng/ml. Relative standard deviations (%, n = 5) were found (at S/N 3) in the range of 1.9 to 10.1. All experiments were carried out at room temperature, 22 ± 0.5 °C.  相似文献   

20.
Hyphenation of packed microcolumn SFC, a photodiode array UV detector, and an inductively coupled plasma spectrometer has been developed in order to evaluate the stability of acetylacetone complexes under supercritical conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号