首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Mass spectrometry (MS) is an effective analytical tool for high-throughput screening (HTS) in the drug discovery field. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MS is a high-throughput platform that has achieved analysis times of sub-seconds-per-sample. Due to the high-throughput analysis speed, methods are needed to increase the analyte signal while decreasing the variability in IR-MALDESI-MS analyses to improve data quality and reduce false-positive hits. The Z-factor is used as a statistic of assay quality that can be improved by reducing the variation of target ion abundances or increasing signal. Herein we report optimal solvent compositions for increasing measured analyte abundances with direct analysis by IR-MALDESI-MS. We also evaluate normalization strategies, such as adding a normalization standard that is similar or dissimilar in structure to the model target drug, to reduce the variability of measured analyte abundances with direct analyses by IR-MALDESI-MS in both positive and negative ionization modes.  相似文献   

3.
The amino acid sequences of mouse monoclonal antibodies have been characterized completely by mass spectrometry. Antibodies used in the present study were derived from mouse switch variant cell lines that produce four kinds of immunoglobulin Gs (IgGs). The amino acid sequences of these antibodies had not been estimated from the corresponding DNA sequence, so the sequences of IgGs derived from other strains were used as references in this study. Intra- and interchain disulfide bonds of the IgGs were reduced and carboxymethylated and the products were subjected to proteolytic digestion. The existence of N-linked oligosaccharides also was taken into account. The capabilities and limitations of matrix-assisted laser desorption ionization-time-of-flight mass spectrometry and capillary liquid chromatography-electrospray ionization mass spectrometry are discussed in the structural characterization of the antibodies. Based on our results, allotypes of the antibodies examined are discussed. This study shows that amino acid sequences of proteins, such as IgG, can be investigated without information about the corresponding DNA sequence if appropriate reference sequences derived from other strains can be used.  相似文献   

4.
The S-nitrosylation of proteins is involved in the trafficking of nitric oxide (NO) in intra- and extracellular milieus. To establish a mass spectrometric method for identifying this post-translational modification of proteins, a synthetic peptide and transthyretin were S-nitrosylated in vitro and analyzed by electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The intact molecular ion species of nitrosylated compounds was identified in the ESI mass spectrum without elimination of the NO group. However, the labile nature of the S-NO bond was evident when the in-source fragmentation efficiently generated [M + H - 30](+) ions. The decomposition was prominent for multiply charged transthyretin ions with high charge states under ordinary ESI conditions, indicating that the application of minimum nozzle potentials was essential for delineating the stoichiometry of nitrosylation in proteins. With MALDI, the S-NO bond cleavage occurred during the ionization process, and the subsequent reduction generated [M + H - 29](+) ions.  相似文献   

5.
Structural characterization of arabinoxylans from wheat by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and electrospray ionization (ESI) mass spectrometry using a Q-TOF mass analyser (ESI-Q-TOF) or an ion trap (IT) mass analyser is presented. An arabinoxylan sample digested with endoxylanase A was analysed using MALDI-TOF mass spectrometry (MS), resulting in the identification of molecular ions for structures with up to 22 monosaccharide residues. As the two-component monosaccharides xylose and arabinose are isobaric, structures differing in the number of arabinose branching residues were indistinguishable based on molecular mass and also fragmentation pattern upon collision-induced dissociation (CID). Permethylation followed by ESI-CID analyses using ITMS was performed to obtain structural information regarding the number of arabinose branching residues and their spatial arrangement along the xylose backbone. Analysis of the signal corresponding to an oligomer with six monosaccharide residues showed the presence of at least four isomeric structures differing in degree of branching and position of the branched residue relative to the cleavage site of the enzyme. This is the first demonstration of the use of ESI-ITMS for the structural characterization of arabinoxylan mixtures.  相似文献   

6.
7.
In our continuing studies to isolate water-soluble vacuolar pigments, we expect to elucidate more structural details using mass spectrometry (MS). Because of its sensitivity, only a small amount of pigment extracted from natural plants is required for MS measurement. Nuclear magnetic resonance is also a useful spectroscopic method for structural determination. In this study, two soft ionization techniques, electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI), on time-of-flight (TOF) mass spectrometers, were used to analyze five polyacylated anthocyanins with more than two aromatic acid molecules in the side chains. ESI is advantageous for the detection of individual molecular ions, while MALDI is essential for the detection of characteristic fragment ions originating from the anthocyanidin. Although 2,5-dihydroxybenzoic acid (DHBA) is an effective matrix in MALDI-TOFMS to obtain informative fragment ions of polyacylated anthocyanins, α-cyano-4-hydroxycinnamic acid (CHCA) is the preferred matrix for the identification of aglycones. In particular, in measurements of polyacylated anthocyanins with two acylated glycoside chains, fragment ions originating from anthocyanidin can only be observed in MALDI-TOFMS using CHCA as the matrix.  相似文献   

8.
The conformation and aggregation behavior of synthetic Alzheimer's amyloid peptides (Abeta) has been investigated using hydrogen-deuterium exchange measured by electrospray ionization mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry. Mass spectrometric fragmentation of deuterated Abeta peptides was carried out by collision-induced dissociation, inlet fragmentation, and post-source decay. In contrast to the C-terminally truncated peptides Abeta(1-40) and Abeta(1-36) showing full hydrogen-deuterium exchange, Abeta(1-42) and the pyroglutamyl peptide Pyr(3)-Abeta(3-42) produced more complex signal patterns resulting from the formation of beta-sheet-structured oligomers having 18-20 strongly protected protons. Using mass spectrometric fragmentation the results show that the reduced isotope exchange of Abeta(1-42) can be attributed to the central part of the chain comprising residues 8-23. This confirms involvement of the hydrophobic binding domain LVFFA in the course of Abeta aggregation and demonstrates that hydrogen-deuterium exchange in combination with mass spectrometry is well suited for structural analysis of monomeric and reversibly associated amyloid peptides using picomole quantities of material.  相似文献   

9.
Design of experiments (DOE) is a systematic and cost-effective approach to system optimization by which the effects of multiple parameters and parameter interactions on a given response can be measured in few experiments. Herein, we describe the use of statistical DOE to improve a few of the analytical figures of merit of the infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) source for mass spectrometry. In a typical experiment, bovine cytochrome c was ionized via electrospray, and equine cytochrome c was desorbed and ionized by IR-MALDESI such that the ratio of equine:bovine was used as a measure of the ionization efficiency of IR-MALDESI. This response was used to rank the importance of seven source parameters including flow rate, laser fluence, laser repetition rate, ESI emitter to mass spectrometer inlet distance, sample stage height, sample plate voltage, and the sample to mass spectrometer inlet distance. A screening fractional factorial DOE was conducted to designate which of the seven parameters induced the greatest amount of change in the response. These important parameters (flow rate, stage height, sample to mass spectrometer inlet distance, and laser fluence) were then studied at higher resolution using a full factorial DOE to obtain the globally optimized combination of parameter settings. The optimum combination of settings was then compared with our previously determined settings to quantify the degree of improvement in detection limit. The limit of detection for the optimized conditions was approximately 10 attomoles compared with 100 femtomoles for the previous settings, which corresponds to a four orders of magnitude improvement in the detection limit of equine cytochrome c.  相似文献   

10.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has successfully been used to differentiate pseudo-enantiomeric (isotopically labelled) amino acids by using cyclodextrin as complexing host. By using different pseudo-enantiomeric mixtures (i.e. R(Dn) + S; and R + S(Dn)), it has been demonstrated that the preference of cyclodextrin for S-enantiomers is not due to the size differences caused by the hydrogen/deuterium substitution. It is postulated that this method can be extended to differentiate enantiomers (and determine enantiomeric excess) by using a pair of enantiomeric hosts, as demonstrated previously using other ionization techniques, but with much higher sensitivity.  相似文献   

11.
The automated use of a matrix-assisted laser desorption ionization (MALDI) mass spectrometer (MS) is described for image analysis of samples through implementation of new software for instrument control, data acquisition, and data analysis. The software permits automated acquisition of MS MALDI spectra to form an ordered data array and contains display features to provide images at one or more mass-to-charge ratio values. The technique can be used to scan tissue samples, blotted samples, gels, or other sample surfaces where the image analysis of that sample is required. The program achieves a time of typically 1 s per image point, permitting an analysis made up of large numbers of points with high spatial resolution up to 850 dpi. The features of the software are demonstrated in this paper with samples of printed images, where visible images can be compared to those obtained by mass spectrometry. Quantitative aspects are introduced by analyzing a series of sample spots containing different amounts of several proteins.  相似文献   

12.
13.
We report the implementation of an infrared laser onto our previously reported matrix-assisted laser desorption electrospray ionization (MALDESI) source with ESI post-ionization yielding multiply charged peptides and proteins. Infrared (IR)-MALDESI is demonstrated for atmospheric pressure desorption and ionization of biological molecules ranging in molecular weight from 1.2 to 17 kDa. High resolving power, high mass accuracy single-acquisition Fourier transform ion cyclotron resonance (FT-ICR) mass spectra were generated from liquid- and solid-state peptide and protein samples by desorption with an infrared laser (2.94 μm) followed by ESI post-ionization. Intact and top-down analysis of equine myoglobin (17 kDa) desorbed from the solid state with ESI post-ionization demonstrates the sequencing capabilities using IR-MALDESI coupled to FT-ICR mass spectrometry. Carbohydrates and lipids were detected through direct analysis of milk and egg yolk using both UV- and IR-MALDESI with minimal sample preparation. Three of the four classes of biological macromolecules (proteins, carbohydrates, and lipids) have been ionized and detected using MALDESI with minimal sample preparation. Sequencing of O-linked glycans, cleaved from mucin using reductive β-elimination chemistry, is also demonstrated.  相似文献   

14.
Matrix-assisted laser desorption/ionization mass spectrometry is an analytical technique enabling the mass analysis of biopolymers with masses up to at least 300,000 Da. Incorporation of analyte in a matrix consisting of small highly absorbing organic molecules and excitation with short pulses of intense laser light enables the production of intact molecule ions to be analyzed in a time-of-flight mass spectrometer. Mass accuracies of up to 0.01% can be achieved from sample amounts of 1 pmol or less. Proteins, glycoproteins, oligonucleotides and oligosaccharides have been analyzed. The short analysis time of several minutes makes the method well suited for combination with other biochemical methods.  相似文献   

15.
Continuous flow infrared matrix‐assisted laser desorption electrospray ionization (CF IR MALDESI) mass spectrometry was demonstrated for the on‐line analysis of liquid samples. Samples in aqueous solution were flowed through a 50 µm i.d. fused‐silica capillary at a flow rate of 1–6 µL/min. As analyte aqueous solution flowed through the capillary, a liquid sample bead formed at the capillary tip. A pulsed infrared optical parametric oscillator (OPO) laser with wavelength of 2.94 µm and a 20 Hz repetition rate was focused onto the capillary tip for sample desorption and ablation. The plume of ejected sample was entrained in an electrospray to form ions by MALDESI. The resulting ions were sampled into an ion trap mass spectrometer for analysis. Using CF IR MALDESI, several chemical and biochemical reactions were monitored on‐line: the chelation of 1,10‐phenanthroline with iron(II), insulin denaturation with 1,4‐dithiothreitol, and tryptic digestion of cytochrome c. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
In this report, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to study the binding interactions between calmodulin and two target peptides (melittin and substance P). Various matrix conditions were tested and the less acidic matrix DHAP and THAP were found to favor the survival of the intact calcium-calmodulin as well as the calmodulin-peptide complexes. However, the application of direct MALDI-MS to detect the intact complexes turned out to be very difficult due to the dissociation of the complexes and the formation of nonspecific aggregates. In contrast, the specific binding of the target peptides to calmodulin could be easily deduced using intensity-fading (IF) MALDI-MS. Compared with the nonbinding control, clear reduction in the ion abundances of the target peptides was observed with the addition of calmodulin. Relative binding affinities of different peptides towards the protein could also be estimated using IF-MALDI-MS. This study may extend the application of IF-MALDI-MS in the analysis of noncovalent complexes and offer a perspective into the utility of MALDI-MS as an alternative approach to study the peptides binding to calmodulin.  相似文献   

17.
The identification of isoforms is one of the great challenges in proteomics due to the large number of identical amino acids preventing their separations by two-dimensional electrophoresis. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has become a rapid and sensitive tool in proteomics, notably with the new instrumental improvements. In this study, we used several acquisition modes of MALDI-TOFMS to identify isoforms of porcine glutathiones S-transferase. The use of multiple proteases coupled to the different acquisition modes of MALDI-TOFMS (linear, reflectron, post-source decay (PSD) and in-source decay, positive and negative modes) allowed the identification of two sequences. Moreover, a third sequence is pointed out from a PSD study of a tryptic ion revealing the modification of the amino acid tyrosine 146 to phenylalanine.  相似文献   

18.
Desorption electrospray ionization mass spectrometry (DESI-MS) is employed in the forensic analysis of documents. Blue ballpoint pen inks applied to ordinary writing paper are examined under ambient conditions without any prior sample preparation. When coupled to an automated moving stage, two-dimensional molecular images are generated. Proof-of-principle experiments include characterization of a simulated forged number and examination of older written records. This application of DESI has advantages over extractive techniques in terms of speed and sample preservation. The effects of the desorbing solvent composition, in this case a mixture of methanol and water, and of flow rate, are evaluated. Results suggest that the solubility of the analyte (dyes Basic Blue 7, Basic Violet 3 and Solvent Blue 26) plays an important role in desorption from the paper surface.  相似文献   

19.
We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity approximately 1 fmol) because the ion source is decoupled from the TOF mass analyzer by extensive gas collisions in the quadrupole stages of the instrument. The capacity to obtain side-by-side high quality ESI and MALDI mass spectra from a single proteolytic mixture greatly facilitates the identification of proteins and elucidation of their primary structures. Improved strategies for protein identification result from this ability to measure spectra using both ionization modes in the same instrument and to perform MS/MS on singly charged as well as multiply charged ions. Examples are provided to demonstrate the utility and performance of the modified instrument.  相似文献   

20.
The role of the laser pulse duration in matrix-assisted laser desorption/ionization mass spectrometry with infrared lasers (IR-MALDI-MS) emitting in the 3 microm wavelength range has been evaluated. Mass spectrometric performance and characteristics of the IR-MALDI process were examined by comparing a wavelength-tuneable mid-infrared optical parametric oscillator (OPO) laser of 6 ns pulse duration, tuned to wavelengths of 2.79 and 2.94 microm, with an Er:YAG laser (lambda = 2.94 microm) with two pulse durations of 100 and 185 ns, and an Er:YSGG laser (lambda = 2.79 microm) with a pulse duration of 75 ns. Threshold fluences for the desorption of cytochrome C ions were determined as a function of the laser pulse duration for various common IR-MALDI matrices. For the majority of these matrices a reduction in threshold fluence by a factor of 1.2-1.9 was found by going from the 75-100 ns long pulses of the Erbium lasers to the short 6 ns OPO pulse. Within the experimental accuracy threshold fluences were equal for the 100 and the 185 ns pulse duration of the Er:YAG laser. Some pronounced pulse duration effects related to the ion formation from a glycerol matrix were also observed. The effect of the laser pulse length on the duration of ion emission was furthermore investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号