共查询到20条相似文献,搜索用时 0 毫秒
1.
Zhigang Shen Zeying HePeng Wang Zhiqiang ZhouMingjing Sun Jingdong LiDonghui Liu 《Analytica chimica acta》2013
A new micro-extraction technique named low-density magnetofluid dispersive liquid–liquid microextraction (LMF-DMMLE) has been developed, which permits a wider range of solvents and can be combined with various detection methods. Comparing with the existing low density solvents micro-extraction methods, no special devices and complicated operations were required during the whole extraction process. Dispersion of the low-density magnetofluid into the aqueous sample is achieved by using vortex mixing, so disperser solvent was unnecessary. The extraction solvent was collected conveniently with an external magnetic field placed outside the extraction container after dispersing. Then, the magnetic nanoparticles were easily removed by adding precipitation reagent under the magnetic field. In order to evaluate the validity of this method, ten organochlorine pesticides (OCPs) were chosen as the analytes. Parameters influencing the extraction efficiency such as extraction solvents, volume of extraction solvents, extraction time, and ionic strength were investigated and optimized. Under the optimized conditions, this method showed high extraction efficiency with low limits of detection of 1.8–8.4 ng L−1, good linearity in the range of 0.05–10.00 μg L−1 and the precisions were in the range of 1.3–9.6% (RSD, n = 5). Finally, this method was successfully applied in the determination of OCPs in real water samples. 相似文献
2.
Lijun He Chunjian Wang Yinjuan Sun Xianli Luo Jing Zhang Kui Lu 《International journal of environmental analytical chemistry》2013,93(6):439-448
A simple, rapid and efficient method, dispersive liquid–liquid microextraction (DLLME) in conjunction with high-performance liquid chromatography (HPLC), has been developed for the determination of three carbamate pesticides (methomyl, carbofuran and carbaryl) in water samples. In this extraction process, a mixture of 35 µL chlorobenzene (extraction solvent) and 1.0 mL acetonitrile (disperser solvent) was rapidly injected into the 5.0 mL aqueous sample containing the analytes. After centrifuging (5 min at 4000 rpm), the fine droplets of chlorobenzene were sedimented in the bottom of the conical test tube. Sedimented phase (20 µL) was injected into the HPLC for analysis. Some important parameters, such as kind and volume of extraction and disperser solvent, extraction time and salt addition were investigated and optimised. Under the optimum extraction condition, the enrichment factors and extraction recoveries ranged from 148% to 189% and 74.2% to 94.4%, respectively. The methods yielded a linear range in the concentration from 1 to 1000 µg L?1 for carbofuran and carbaryl, 5 to 1000 µg L?1 for methomyl, and the limits of detection were 0.5, 0.9 and 0.1 µg L?1, respectively. The relative standard deviations (RSD) for the extraction of 500 µg L?1 carbamate pesticides were in the range of 1.8–4.6% (n = 6). This method could be successfully applied for the determination of carbamate pesticides in tap water, river water and rain water. 相似文献
3.
An ultra-preconcentration technique composed of solid-phase extraction (SPE) and dispersive liquid–liquid microextraction (DLLME) coupled with gas chromatography–flame photometric detection (GC–FPD) was used for determination of thirteen organophosphorus pesticides (OPPs) including phorate, diazinon, disolfotane, methyl parathion, sumithion, chlorpyrifos, malathion, fenthion, profenphose, ethion, phosalone, azinphose-methyl and co-ral in aqueous samples. The analytes were collected from large volumes of aqueous solutions (100 mL) into 100 mg of a SPE C18 sorbent. The effective variables of SPE including type and volume of elution solvent, volume and flow rate of sample solution, and salt concentration were investigated and optimized. Acetone was selected as eluent in SPE and disperser solvent in DLLME and chlorobenzene was used as extraction solvent. Under the optimal conditions, the enrichment factors were between 15,160 and 21,000 and extraction recoveries were 75.8–105.0%. The linear range was 1–10,000 ng L?1 and limits of detection (LODs) were between 0.2 and 1.5 ng L?1. The relative standard deviations (RSDs) for 50 ng L?1 of OPPs in water with and without an internal standard, were in the range of 1.4–7.9% (n = 5) and 4.0–11.6%, respectively. The relative recoveries of OPPs from well and farm water sat spiking levels of 25 and 250 ng L?1 were 88–109%. 相似文献
4.
Chunhong Jia Xiaodan Zhu Jihua Wang Ercheng Zhao Min He Li Chen Pingzhong Yu 《Journal of chromatography. A》2010,1217(37):5868-5871
A simple solvent microextraction method termed vortex-assisted liquid–liquid microextraction (VALLME) coupled with gas chromatography micro electron-capture detector (GC-μECD) has been developed and used for the pesticide residue analysis in water samples. In the VALLME method, aliquots of 30 μL toluene used as extraction solvent were directly injected into a 25 mL volumetric flask containing the water sample. The extraction solvent was dispersed into the water phase under vigorously shaking with the vortex. The parameters affecting the extraction efficiency of the proposed VALLME such as extraction solvent, vortex time, volumes of extraction solvent and salt addition were investigated. Under the optimum condition, enrichment factors (EFs) in a range of 835–1115 and limits of detection below 0.010 μg L−1 were obtained for the determination of target pesticides in water. The calculated calibration curves provide high levels of linearity yielding correlation coefficients (r2) greater than 0.9958 with the concentration level ranged from 0.05 to 2.5 μg L−1. Finally, the proposed method has been successfully applied to the determination of pesticides from real water samples and acceptable recoveries over the range of 72–106.3% were obtained. 相似文献
5.
Triantafyllos A. Albanis Dimitra G. Hela Dimitra A. Lambropoulou A. Sakkas Vasilios 《International journal of environmental analytical chemistry》2013,93(14-15):1079-1092
Solid-phase microextraction (SPME) coupled with gas chromatography–mass spectrometry (GC–MS) and selected ion monitoring (SIM) was used for the analytical determination of priority pesticide residues. Fibers coated with a 65-µm film thickness of polydimethylsiloxane divinylbenzene (PDMS-DVB) were used to extract 31 pesticides of different chemical groups. The quality parameters of the method demonstrated a good precision with detection limits of 1–56?ng/L. Linearity was controlled in the range of 0.1–50?µg/L. The proposed method was applied for the trace-level determination of the target pesticides in surface water samples including three rivers and one lake at the Epirus region (north-west Greece) for a period of one year. The results demonstrate the suitability of the SPME–GC–MS approach for the analysis of multi-residue pesticides in environmental water samples. 相似文献
6.
A simple, sensitive and selective method for the simultaneous determination of five ultraviolet (UV) filters: benzophenone, octyl salicylate, homosalate, 3-(4-methylbenzylidene) camphor, 2-hydroxy-4-methoxybenzophenone in aqueous samples was developed. The analytes were extracted by plunger-in-needle solid-phase microextraction with graphene as sorbent, then silylated on-fiber with N-methyl-N-(trimethylsilyl)trifluoroacetamide, and analyzed by gas chromatography–mass spectrometry. Factors affecting the performance of extraction and derivatization steps were thoroughly evaluated. For the optimization of extraction conditions, six relevant factors (parameters) were investigated, including sample pH, salt concentration, extraction time, extraction temperature, stirring speed and sampling mode. In the first stage, a two-level orthogonal array design OA8 (27) matrix was employed to study the effect of six factors. Based on the results of the first stage, three factors were selected for further optimization with a univariant approach during the second stage. Under the final optimized conditions, the method limits of detection for the five UV filters were determined to be in the range of 0.5 and 6.8 ng L−1 (at a signal/noise ratio of 3) and the precision (% relative standard deviation, n = 5) was 0.8–5.6% at a concentration level of 1 μg L−1. The linearities for different analytes were 10–10,000 or 1–5000 ng L−1. The coefficients of determination for the calibration curves were all greater than 0.994. Finally, the proposed method was successfully applied to the extraction and determination of the UV filters in river water samples. 相似文献
7.
Mohana Krishna Reddy Mudiam Rajeev Jain Virendra K. Dua Amit Kumar Singh V. P. Sharma R. C. Murthy 《Analytical and bioanalytical chemistry》2011,401(5):1699-1705
A simple and rapid analytical method based on in-matrix ethyl chloroformate (ECF) derivatization has been developed for the
quantitative determination of bisphenol-A (BPA) in milk and water samples. The samples containing BPA were derivatised with
ECF in the presence of pyridine for 20 s at room temperature, and the non-polar derivative thus formed was extracted using
polydimethylsiloxane solid-phase microextraction (SPME) fibres with thicknesses of 100 μm followed by analysis using gas chromatography–mass
spectrometry. Three alkyl chloroformates (methyl, ethyl and isobutyl chloroformate) were tested for optimum derivatisation
yields, and ECF has been found to be optimum for the derivatisation of BPA. Several parameters such as amount of ECF, pyridine
and reaction time as well as SPME parameters were studied and optimised in the present work. The limit of detection for BPA
in milk and water samples was found to be 0.1 and 0.01 μg L−1, respectively, with a signal-to-noise ratio of 3:1. The limit of quantitation for BPA in milk and water was found to be 0.38
and 0.052 μg L−1, respectively, with a signal-to-noise ratio of 10:1. In conclusion, the method developed was found to be rapid, reliable
and cost-effective in comparison to silylation and highly suitable for the routine analysis of BPA by various food and environmental
laboratories. 相似文献
8.
A new fiber for solid-phase microextraction (SPME) was prepared employing cork as a coating. The morphology and composition of the cork fiber was evaluated by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR), respectively. The proposed fiber was used for the determination of polycyclic aromatic hydrocarbons (PAHs) in river water samples by gas chromatography–selected ion monitoring–mass spectrometry (GC–SIM–MS). A central composite design was used for optimization of the variables involved in the extraction of PAHs from water samples. The optimal extraction conditions were extraction time and temperature of 60 min and 80 °C, respectively. The detection and quantification limits were 0.03 and 0.1 μg L−1, respectively. The recovery values were between 70.2 and 103.2% and the RSD was ≤15.7 (n = 3). The linear range was 0.1–10 μg L−1 with r ≥ 0.96 and the fiber-to-fiber reproducibility showed RSD ≤ 18.6% (n = 5). The efficiency of the cork fiber was compared with commercially available fibers and good results were achieved, demonstrating the applicability and great potential of cork as a coating for SPME. 相似文献
9.
10.
A procedure for the determination of three phosphoric acid diesters, eight triesters and triphenylphosphine oxide (TPPO) in water samples is presented. Analytes were simultaneously concentrated using a mixed-mode (reversed-phase and anionic-exchange) solid-phase extraction (SPE) sorbent and then sequentially eluted with methanol (triesters and TPPO) followed by a 20 mM tetrabutylammonium hydrogen sulphate (TBAHS) methanolic solution, case of diesters. After that, they were determined, in two different runs, by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS/MS), operating the ESI source in the positive (triesters and TPPO) and negative (diesters) ionization modes. The efficiency of the extraction step varied between 70 and 105%, except in the case of tris(2-ethylhexyl) phosphate (TEHP), and it was barely affected by the type of water sample. Moreover, low signal suppression effects were noticed in the ESI ionization of extracts obtained from different environmental water samples. As a result, the standard addition methodology was only required for the accurate quantification of tri-substituted organophosphorus (OPs) species in wastewater samples. Limits of quantification of the optimized method ranged from 0.2 to 10 ng L−1, depending on the sample matrix and the considered compound. The analysis of river and wastewater samples confirmed the occurrence of several tri- and di-substituted OPs in the aquatic environment, with the highest concentrations corresponding to tris(butoxyethyl) phosphate (TBEP) and tris(chloropropyl) phosphate (TCPP). 相似文献
11.
12.
Bi-Yi Yang Fei-Fei Qi Xiao-Qing Li Jing-Jing Liu Fei Rong 《International journal of environmental analytical chemistry》2015,95(12):1112-1123
A novel solid-phase extraction (SPE) system, based on a new sorbent of Nylon6/Polypyrrole (PA6/PPy) core–shell nanofibres mat and a new packing format of SPE disks, is presented in this paper. A series of related parameters that may affect the efficiency, such as the kind of eluent and its volume, the amount of nanofibres mat, ionic strength, pH of the sample, flow rate of the sample and volume of the sample, have been investigated systematically. Under the optimised conditions, the target analyte in 10 mL water samples can be completely extracted by a 3.0 mg PA6/PPy nanofibres mat and easily eluted by 400 µL acetonitrile. Around 20 µL elution was injected directly to HPLC-UV for determination, without further concentration. Besides, the nanofibres mat could be repeatedly used up to six cycles. Satisfactory linearity was achieved in the range of 0.1–40.0 ng/mL with a correlation coefficient of 0.9999. The limit of detection (LOD) (3 S/N) was 0.03 ng/mL, which could meet the determination requirements of atrazine as per the European Union legislation, US. Safe Drinking Water Act and the State Environmental Protection Administration of China. The simple, effective and economic method was proposed for the determination of atrazine in environmental water at trace level. The recoveries ranged from 94.73 to 114.92%, with relative standard deviations (RSDs) of 2.5–4.2%, and were obtained from tap water and lake water samples with atrazine at 2.0 ng/mL, suggesting the actual feasibility of the proposed method in environmental water samples. 相似文献
13.
A novel solid phase microextraction (SPME) fiber was prepared and coupled with gas chromatography corona discharge ion mobility spectrometry (GC–CD–IMS) based on polypyrrole/montmorillonite nanocomposites for the simultaneous determination of diazinon and fenthion. The nanocomposite polymer was coated using a three-electrode electrochemical system and directly deposited on a Ni–Cr wire by applying a constant potential. The scanning electron microscopy images revealed that the new fiber exhibited a rather porous and homogenous surface. The thermal stability of the fabricated fiber was investigated by thermogravimetric analysis. The effects of different parameters influencing the extraction efficiency such as extraction temperature and time, salt addition, stirring rate, the amount of nanoclay, and desorption temperature were investigated and optimized. The method was exhaustively evaluated in terms of sensitivity, recovery, and reproducibility. The linearity ranges of 0.05–10 and 0.08–10 μg L−1, and the detection limits of 0.020 and 0.035 μg L−1 were obtained for diazinon and fenthion, respectively. The relative standard deviation values were calculated to be lower than 5% and 8% for intra-day and inter-day, respectively. Finally, the developed method was applied to determine the diazinon and fenthion (as model compounds) in cucumber, lettuce, apple, tap and river water samples. The satisfactory recoveries revealed the capability of the two-dimensional separation technique (retention time in GC and drift time in IMS) for the analysis of complex matrices extracted by SPME. 相似文献
14.
Asensio-Ramos M D'Orazio G Hernandez-Borges J Rocco A Fanali S 《Analytical and bioanalytical chemistry》2011,400(4):1113-1123
In this work, the simultaneous separation of a group of 12 pesticides (carbaryl, fensulfothion, mecoprop, fenamiphos, haloxyfop,
diclofop, fipronil, profenofos, fonofos, disulfoton, nitrofen, and terbufos) by nano-liquid chromatography with UV detection
is described. For the analyses, a 100 μm internal diameter capillary column packed with silica modified with phenyl groups
was used. Experimental parameters, including the use of a trapping column for increasing the sensitivity, were optimized and
validated. A preliminary study of the applicability of a rapid and practical dispersive solid-phase extraction (DSPE) procedure
was developed for the extraction of some of these pesticides (carbaryl, fensulfothion, fenamiphos, fipronil, profenofos, fonofos,
disulfoton, nitrofen, and terbufos) from Milli-Q water samples using multi-walled carbon nanotubes (MWCNTs). The method was
validated through a recovery study at three different levels of concentration, obtaining limits of detection in the range
0.016–0.067 μg/L (below European Union maximum residue limits) for the majority of the pesticides. In this work, MWCNTs were
reused up to five times, representing an important reduction of the waste of stationary phase. Furthermore, DSPE permitted
a clear diminution of the total sample treatment time with respect to conventional SPE. 相似文献
15.
Solid-phase extraction (SPE) was combined with headspace solid-phase microextraction (HS-SPME) for the highly effective enrichment of 17 ultra trace organochlorine pesticides in water samples. The target compounds were successfully transferred from water samples to a gas chromatography capillary column by means of four consecutive steps, namely SPE, solvent conversion, HS-SPME, and thermal desorption of the SPME fiber. Parameters, including elution volume and breakthrough volume in the SPE step, temperature in the solvent conversion step, and fiber type, ionic strength, extraction temperature, extraction time, and pH in the SPME step were optimized to improve the performance of the method through either single factor comparative experiment or the orthogonal experimental design approach. After optimization, the method gave high sensitivity with a method detection limit ranging from 0.0018 to 0.027 ng L−1, good repeatability with a relative standard deviation less than 20% (n = 4) and acceptable recovery with a value mostly exceeding 60%. External standard calibration was employed for the quantification, and a wide linear range (from 0.0010 to 60 ng mL−1) with R2 values ranging from 0.9988 to 0.9999 were observed. In the end, the method was successfully applied to the Arctic samples, and the results showed that, among all the organochlorine pesticides, hexachlorocyclohexanes (HCHs) were the most predominant in the Arctic surface water body with sum of their concentrations ranging from 0.262 to 3.156 ng L−1. 相似文献
16.
Maysam Gharehbaghi Majid Baghdadi 《International journal of environmental analytical chemistry》2013,93(7):513-523
A new simple and rapid dispersive liquid–liquid microextraction has been applied to preconcentrate trace levels of cobalt as a prior step to its determination by spectrophotometric detection. In this method a small amount of chloroform as the extraction solvent was dissolved in pure ethanol as the disperser solvent, then the binary solution was rapidly injected by a syringe into the water sample containing cobalt ions complexed by 1-(2-pyridylazo)-2-naphthol (PAN). This forms a cloudy solution. The cloudy state was the result of chloroform fine droplets formation, which has been dispersed in bulk aqueous sample. Therefore, Co-PAN complex was extracted into the fine chloroform droplets. After centrifugation (2 min at 5000 rpm) these droplets were sedimented at the bottom of conical test tube (about 100 µL) and then the whole of complex enriched extracted phase was determined by a spectrophotometer at 577 nm. Complex formation and extraction are usually affected by some parameters, such as the types and volumes of extraction solvent and disperser solvent, salt effect, pH and the concentration of chelating agent, which have been optimised for the presented method. Under optimum conditions, the enhancement factor (as the ratio of slope of preconcentrated sample to that obtained without preconcentration) of 125 was obtained from 50 mL of water sample, and the limit of detection (LOD) of the method was 0.5 µg L?1and the relative standard deviation (RSD, n = 5) for 50 µg L?1 of cobalt was 2.5%. The method was applied to the determination of cobalt in tap and river water samples. 相似文献
17.
Casas V Llompart M Garcia-Jares C Cela R Dagnac T 《Analytical and bioanalytical chemistry》2007,387(5):1841-1849
The aqueous instability of pyrethroids and other compounds usually found in commercial pesticide formulations has been demonstrated
in this work. Several types of sample treatment have been studied to avoid analyte losses during sample manipulation and storage.
Analysis was performed by SPME–GC–MS. Addition of sodium thiosulfate to tap water prevented pyrethroid degradation as a result
of oxidation by free chlorine. The amount added was optimized to minimize the effect of the salt on the analytical results.
Analysis of samples that had been stored at 4 °C for several days revealed loss of some of the pyrethroids in the first period
of storage. The effect of freezing the samples was studied and it was confirmed that samples could be stabilized for at least
one week by freezing. Finally, addition of a miscible organic solvent, for example acetone, led to improvement of the analytical
precision. The quality of the SPME–GC–MS method was studied. Linearity (R > 0.993), repeatability (RSD < 15%), and sensitivity
(detection limits between 0.9 and 35 pg mL−1) were good. When the procedure was applied to real samples including run off and waste water some of the target compounds
were identified and quantified.
相似文献
18.
Mina Yarazavi Ebrahim Noroozian Mehdi Mousavi 《Journal of the Iranian Chemical Society》2018,15(11):2593-2603
Sol–gel coating technology for the preparation of solid-phase microextraction fibers involves a single-step procedure and allows for in situ creation of chemically bonded coatings which are characterized by high thermal and solvent stabilities. A novel titania sol–gel coating was prepared for the first time on a stainless steel fiber and applied for the headspace solid-phase microextraction (HS-SPME) of menthol with gas chromatography and flame ionization detection. Important parameters influencing the efficiency of SPME process, such as extraction time, extraction temperature and ionic strength, were optimized by central composite design. An extraction time of 40 min at 60 °C gave maximum extraction efficiency, when NaCl (10% w/v) was added to the aqueous sample. The analytical characteristics of the proposed method were comparable with other reported fibers. Under optimized conditions, the linearity was between 0.05 and 100 µg mL??1. The relative standard deviations (RSDs) determined at 0.5 µg mL??1 concentration level (n?=?5) were as follows: intra-day RSD 7.26%; inter-day RSD 10.87%; fiber-to-fiber RSD 9.05%. The relative recoveries determined after spiking a mint distillate sample at three concentration levels from 0.067 to 50.0 µg mL??1 varied from 86 to 102%. The proposed method was successfully applied for the analysis of menthol in peppermint samples. 相似文献
19.
Wan-Ru Sheng Yue Chen Shan-Shan Wang Xiao-Li Wang Ming-Lin Wang Ru-Song Zhao 《Analytical and bioanalytical chemistry》2016,408(29):8289-8297
20.
Ehsan Zolfonoun Maryam Salahinejad 《Journal of Radioanalytical and Nuclear Chemistry》2013,298(3):1801-1807
A new simple and rapid vortex-assisted liquid–liquid microextraction method was applied for the determination of thorium in water samples. In this method, chloroform used as extraction solvent was directly injected into the water sample solution. The extraction solvent was dispersed into the aqueous phase under vigorously shaking with the vortex. After centrifuging, the fine droplets of extractant phase were settled to the bottom of the conical-bottom centrifuge tube. The effect of different experimental parameters on the performance of the method were studied and discussed. Under the optimum conditions, the detection limit for Th(IV) was 7.5 ng mL?1. The precision of the method, evaluated as the relative standard deviation obtained by analyzing of 10 replicates, was 2.8 %. The practical applicability of the developed method was examined using natural water and monazite sand samples. 相似文献