首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A digestion mixture of H2SO4/HNO3/H2O2/HF/V2O5 was investigated for decomposition of plant samples and sensitive detection of selenium was achieved by hydride generation atomic fluorescence spectrometry (HG-AFS). The method was found to be accurate and reproducible, with a low detection limit (DL) (0.14 ng g−1 solution). The repeatability of the determination was mostly around 10%, the reproducibility over a period of 8 months for determination of selenium in the standard reference material Trace Elements in Spinach Leaves, NIST 1570a, was 9% and the relative measurement uncertainty was 7% using a coverage factor of 2.3 at 95% probability. The average recovery of the whole procedure was 90%. The characteristics of this method are simple and inexpensive equipment, low consumption of chemicals and the ability to analyse many samples in a short time. The whole procedure was carried out in the same PTFE tube, and in addition only a simple cleaning procedure is needed. As a consequence of all these advantages, the described method is suitable for environmental and nutritional studies. The selenium content was determined in 44 vegetable samples from different regions of Slovenia and the contents found were in the range 0.3-77 ng g−1 wet weight.  相似文献   

2.
流动注射在线共沉淀HG-AFS测定痕量铅   总被引:2,自引:0,他引:2  
建立了流动注射在线共沉淀HG-AFS测定痕量铅的分析方法。方法基于铅在碱性介质中与氢氧化镁共沉淀,沉淀收集在锥形沉淀腔中,用HCl溶洗沉淀和NaBH4反应,产生的氢化物被载气引入原子化器中进行测定。测定铅的RSD为3%(5ng/mL,n=10),检出限为0.01ng。检出限较直接进样降低了11倍。对国家标准物质中铅的测定结果与标准值相符。  相似文献   

3.
利用电磁感应加热原理,研制了在线消化还原、氢化物发生原子荧光法分析装置,实现了茶水中As量的在线测定.对各种实验参数和干扰情况进行了研究.方法的检出限为0.063 μg/L;样品分析精密度(RSD)为2.5%(n=11).  相似文献   

4.
A method was proposed for the determination of zinc by atomic fluorescence spectrometry with hydride generation from surfactant-based organized media. The ability of different nature micelles to improve hydride generation of zinc was investigated using an intermittent flow hydride generator and the possible mechanism was discussed. The advantages of hydride generation from the organized media of cetyltrimethylammonium bromide (CTAB) were contrasted with that from aqueous media in sensitivity and precision of the zinc determination. The micellar media of CTAB improved the hydride generation processes of zinc both thermodynamically and kinetically. In addition some transition metals, presumably metal borides, were found to catalyze the hydrogenation of zinc. The proposed method has been validated by the determination of zinc in the certified reference materials using the standard addition method with satisfactory result.  相似文献   

5.
运用以聚苯胺修饰的石墨电极为阴极的电化学氢化物发生装置实现了锡元素的电化学氢化物发生.在电极表面聚合一层聚苯胺,能够有效地提高锡元素的电化学氢化物发生效率,通过与原子荧光光谱仪联用,成功地测定了食品中的锡含量.本工作对各种实验参数和干扰情况进行了详细研究.方法对锡的检出限为1.2 ng/mL(3σ);样品分析精密度(R...  相似文献   

6.
A systematic study of antimony reduction prior to its determination by hydride generation atomic fluorescence spectrometry (HG-AFS) was carried out. The efficiency of l-cysteine, potassium iodide and potassium iodide/ascorbic acid was studied for this purpose. The hydride generation step was optimised in the presence of those pre-reductors. From the results, l-cysteine was found to be the most suitable pre-reducing agent. Methodology was validated, obtaining detection limits lower than 90 ng l−1 and repeatability and reproducibility better than 3% R.S.D. and 5% R.S.D., respectively, in all cases. In order to evaluate the methodology developed and the influence of the matrix, recovery from waters from different sources was tested by HG-AFS and also by inductively coupled plasma mass spectrometry (ICP-MS). Accuracy was assessed by analysing three water reference materials at different antimony concentration levels. The high sensitivity of the developed methodology enables it to be applied for monitoring drinking waters according to the maximum admissible concentration of antimony established by the EU Directives.  相似文献   

7.
Zhi Xing 《Talanta》2009,80(1):139-142
An atmospheric pressure dielectric barrier discharge (DBD) atomizer was investigated for bismuth (Bi) determination with hydride generation (HG) atomic fluorescence spectrometry (AFS). The characteristics of the atomizer and the effects of experimental parameters, including observation height, discharge power, flow rate of discharge gas and AFS carrier gas were optimized. The linear range of present method for Bi determination is 0.5-300.0 μg L−1 with a detection limit of 0.07 μg L−1 (3σ). The method was validated by the analysis of reference materials (GBW08517 and GSB-14) and the results agreed well with the reference values. The established method was applied to the determination of Bi in ore, soil and ash samples.  相似文献   

8.
In this work, the determination of total As in seawater by hydride generation atomic fluorescence spectrometry was studied. The influence of the chemical, flow and instrumental parameters were investigated and optimized. The pre-reduction of As(V) to As(III) was performed using KI plus ascorbic acid in 3.5 mol L− 1 HCl medium. No multiplicative interference was present and external aqueous calibration could be used. The limit of detection was 36 ng L− 1, while the repeatability was 2% (n = 10), at a 500 ng L− 1 concentration level. The sample throughput was 15 h− 1 if triplicate measurements were made. The accuracy was assessed by the analysis of a seawater certified reference material and excellent agreement between the obtained and certified values was verified. The procedure was used for the analysis of seawater offshore samples collected at the Brazilian coast and results ranging from 860 to 1200 ng L− 1 were found.  相似文献   

9.
建立了一种顺序注射氢化物发生-原子荧光光谱法测定试样中Se和As的方法,同时讨论了共存离子的干扰情况.在最佳实验条件下,Se和As的检出限分别为0.16和0.095 μg/L,加标回收率为92.4%~104.7%.  相似文献   

10.
Hydride generation atomic fluorescence spectrometry was for the first time utilized to determine trace toxic element arsenic in the skeleton fossils of four dinosaurs unearthed in Sichuan Province of China. The instrumental limit of detection (LOD) for arsenic was 0.03 μg/L under optimal experimental conditions, which compared favorably to that by ICP-AES and ETAAS. The samples were digested with aqua regia in boiling water bath. The recoveries of standard addition were found to be from 97 to 109%, and the analytical results were found in good agreement with those by ICP-AES. It is a simple, reliable, sensitive yet relatively inexpensive analytical method, compared to ICP-AES, ICP-MS or ETAAS. Interesting analytical results were found that the arsenic concentrations were all abnormally high in the skeleton fossils. The established analytical method and the analytical results may be helpful in revealing the mystery of the mass extinction of the dinosaur fauna. The analytical results, together with other data available to date, supported the argument that the arsenic toxicosis could be a contributing factor for the mass extinction of the dinosaur fauna in Sichuan Province of China.  相似文献   

11.
An electrochemical hydride generation system was developed for the detection of Te by coupling an electrochemical hydride generator with atomic fluorescence spectrometry. Since TeH2 is unstable and easily decomposes in solution, a reticular W filament cathode was used in the present system. The TeH2 generated on the cathode surface was effectively driven out by sweeping gas from the cathode chamber. In addition, a low temperature electrochemical cell (10 °C) was applied to reduce the decomposition of TeH2 in solution. The limit of detection (LOD) was 2.2 ng ml− 1 and the relative standard deviation (RSD) was 3.9% for nine consecutive measurements of standard solution. This method was successfully employed for determination of Te in soldering tin material.  相似文献   

12.
The dominant role played by flow injection/sequential injection (FI/SI, including lab-on-valve, LOV) in automatic on-line sample pretreatments coupling to various detection techniques is amply demonstrated by the large number of publications it has given rise to. Among these, its hyphenation with hydride/vapor generation atomic fluorescence spectrometry (HG/VG-AFS) has become one of the most attractive sub-branches during the last years, attributed not only to the high sensitivity of this technique, but also to the superb separation capability of hydride/vapor forming elements from complex sample matrices. In addition, it also provides potentials for the speciation of the elements of interest.It is worth mentioning that quite a few novel developments of sample pretreatment have emerged recently, which attracted extensive attentions from the related fields of research. The aim of this mini-review is thus to illustrate the state-of-the-art progress of implementing flow injection/sequential injection and miniaturized lab-on-valve systems for on-line hydride/vapor generation separation and preconcentration of vapor forming elements followed with detection by atomic fluorescence spectrometry, within the period from 2004 up to now. Future perspectives in this field are also discussed.  相似文献   

13.
A quartz multiatomizer with its inlet arm modified to serve as a trap (trap-and-atomizer device) was employed to trap tin hydride and subsequently to volatilize collected analyte species with atomic absorption spectrometric detection. Generation, atomization and preconcentration conditions were optimized and analytical figures of merit of both on-line atomization as well as preconcentration modes were quantified. Preconcentration efficiency of 95 ± 5% was found. The detection limits reached were 0.029 and 0.14 ng mL−1 Sn, respectively, for 120 s preconcentration period and on-line atomization mode without any preconcentration. The interference extent of other hydride forming elements (As, Se, Sb and Bi) on tin determination was found negligible in both modes of operation. The applicability of the developed preconcentration method was verified by Sn determination in a certified reference material as well as by analysis of real samples.  相似文献   

14.
A software-controlled time-based multisyringe flow-injection system for total inorganic arsenic determination by hydride generation atomic fluorescence spectrometry (HGAFS) has been developed. By using a multisyringe burette coupled with one multiport selection valve, the time-based injection provides precise known volumes of sample, a reducing sodium tetrahydroborate solution and a pre-reducing solution which are dispensed into a gas-liquid separation cell. An argon flow delivers the arsine into the flame of an atomic fluorescence spectrometer. A hydrogen flow has been used to support the flame.Linear calibration graphs for arsenic concentrations between 0.25 and 12 μg l−1 were obtained. The detection limit of the proposed technique (3σb/S) was 0.07 μg l−1. A sample throughput of 36 samples/h (108 injections) has been achieved. The proposed technique has been validated by means of reference solid and water materials with good agreement with the certified values. This method was compared with those reported in previous sequential injection analysis (SIA) and flow-injection analysis (FIA) systems. The proposed method offers a number of advantages in front the usual AFS applications, which are mainly a higher sampling frequency and a significant reduction in reagent consumption.  相似文献   

15.
Flame-in-gas shield miniature hydride atomizers (FIGS) have been investigated and evaluated in view of their alternative use to miniature diffusion flame hydride atomizer (MDF) to determination of hydride forming elements by atomic fluorescence spectrometry (AFS). Chemical vapour generation (CVG) by aqueous phase derivatization by NaBH4 in a continuous flow generator (CF) was employed for the generation of volatile hydrides of As, Sb, Bi, Se, Te and Sn. A dispersive AFS apparatus using electrodeless discharge lamps (EDL) as the excitation sources has been employed for both spectra acquisition and analytical determinations. The characteristics of FIGS in terms of background emission spectra, most intense AF spectral lines and limits of detection were compared with those of most popular MDF. FIGS presents a lower background emission with respect to MDF, allowing also the control of the molecular fluorescence of OH radicals in the determination of bismuth. Limits of detection for FIGS compare very well with to those obtained by MDF giving improvement factor of 5.5, 4.4, 3.6, 3.6, 0.7 an 0.5 for Bi, As, Se, Son, Te and Sb. Accuracy of FIGS has proven by determination of arsenic and antimony in seawater (NASS-5) and river water (SRLS-4) certified reference materials and bismuth in unalloyed copper (CuV 398, CuVI 399) standard reference materials by dispersive CVG-AFS.  相似文献   

16.
A rapid, accurate, and precise method is described for the determination of Pb in wine using continuous-flow hydride generation atomic fluorescence spectrometry (CF-HGAFS). Sample pretreatment consists of ten-fold dilution of wine followed by direct plumbane generation in the presence of 0.1 mol L−1 HCl and 1% m/v K3[Fe(CN)6] with 1% m/v NaBH4 as reducing agent. An aqueous standard calibration curve is recommended for Pb quantification in wine sample. The method provides a limit of detection and a limit of quantification of 0.3 μg L−1 and 1 μg L−1, respectively. The relative standard deviation varies between 2–6% (within-run) and 4–11% (between-run) at 3–30 μg L−1 Pb levels in wine. Good agreement has been demonstrated between results obtained by CF-HGAFS and direct electrothermal atomic absorption spectrometry in analyses of red and white wines within the concentration range of 9.2–25.8 μg L−1 Pb.  相似文献   

17.
A simple, sensitive and accurate method for selenium speciation in natural waters is proposed. The principle of this method is based on recently discovered photochemical reactions of Se(IV) and organic selenium in different aqueous solutions. The speciation of all selenium species was performed with hydride generation-atomic fluorescence spectrometry. Only one pre-reduction step is needed in this procedure, which can greatly reduce the risk of contamination, minimize the analytical work and improve the quality of selenium speciation. In this paper, a comparison is made between the proposed method and a previous method [A.G. Cutter, Anal. Chim. Acta 98 (1978) 59]. In this proposed protocol, Se(IV) was directly measured in 3.0 M HCl. Se(IV) + org-Se was measured directly after a UV irradiation (300 nm) for 2.5 h in a 1.0% (v/v) HNO3-2.0% (v/v) HCl matrix. Total selenium was obtained in another aliquot sample after a UV irradiation in the 3.0 M HCl. No pre-concentration, separation or more sophisticated instruments are required.  相似文献   

18.
A simple and fast analytical procedure has been developed for the determination of As, Sb, Se, Te and Bi in milk samples by hydride generation atomic fluorescence spectrometry (HG-AFS). Samples were treated with aqua regia for 10 min in an ultrasound water bath and pre-reduced with KBr for total Se and Te determination or with KI and ascorbic acid for total As and Sb, the determination of Bi being possible in all with or without pre-reduction. Slurries of samples, in the presence of antifoam A, were treated with NaBH4 in HCl medium to obtain the corresponding hydrides, and AFS measurements were processed in front of external calibrations prepared and measured in the same way as samples. Results obtained by the developed procedure compare well with those found after microwave-assisted complete digestion of samples. The proposed method is simple and fast, and only 1 ml of milk is needed. The values obtained for detection limit are 2.5, 1.6, 3, 6 and 7 ng l−1 for As, Sb, Se, Te and Bi respectively in the diluted samples, with average relative standard deviation values of 3.8, 3.1, 1.9, 6.4 and 1.2% for three independent analysis of a series of commercially available samples of different origin. Data found in Spanish market samples varied from 3.2±0.3 to 11.3±0.2 ng g−1 As, from 3.1±0.2 to 11.6±0.4 ng g−1 Sb, from 10.7±0.5 to 25.5±0.4 ng g−1 Se, from 0.9±0.2 to 9.4±0.6 ng g−1 Te and from 11.5±0.1 to 27.7±0.4 ng g−1 Bi.  相似文献   

19.
A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow milk samples, obtained from the Spanish market evidenced the presence of As at concentration levels from 3.4 to 11.6 ng g−1 and Sb levels from 3.5 to 11.9 ng g−1, thus in a proportion near to 1:1, which is in contrast with the 10:1 natural ratio between As and Sb and could evidence the effect of the introduction of new alloys and polymer materials in the industrial process of milk. The method was validated by the comparison of data found for commercial samples by using the proposed procedure and reference methods based on dry-ashing and AFS, and microwave-assisted digestion and inductively coupled plasma mass spectrometry determination.  相似文献   

20.
氢化物发生-原子荧光光谱法测定中草药中的微量砷   总被引:8,自引:0,他引:8  
研究了氢化物发生-原子荧光光谱法测定中草药中微量砷的方法的最佳条件,以50g/L硫脲 50g/L抗坏血酸为预还原抗干扰剂,测定了10种中草药药品中的砷,方法检出限(3σ)为0.103μg/L,相对标准偏差为1.6%-3.2%,回收率为89.2%-112%。  相似文献   