首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Summary The quantitative determination of trace elements in human blood serum by Total Reflection X-Ray Fluorescence Analysis (TXRF) is influenced by absorption- and reflection-effects caused by the organic (proteins) and inorganic (P, S, Na, K, Ca, Cl) matrices. To minimize these effects we have developed a sample preparation technique based on the decomposition of the organic matrix and followed by the separation of the trace elements from the organic matrix by ion-exchange. The described method enables the simultaneous determination of K (1584 g), Ca (666 g), Fe (22 g), Cu (9.6 g), Zn (8.8 g), Se (0.97 g), Sn (1.3 g), Pb (0.12 g) and Rb (1.6 g) (obtained values in parentheses).

Herrn Prof. Dr. G. Tölg zum 60. Geburtstag gewidmet  相似文献   

2.
Zusammenfassung Ein schnelles und einfaches Mikroverfahren zum Nachweis einiger Heteroatome organischer Verbindungen wurde entwickelt. Nach Aufschluß mit metallischem Kalium werden die entstehenden Ionen mit der Ringofenmethode getrennt und mit empfindlichen Reaktionen nachgewiesen. Nachweisgrenze: 0,5 bis 1g Stickstoff, 1 bis 2g Schwefel, 2 bis 3g Jod, 4 bis 5g Brom, 5 bis 10g Chlor in 0,5 bis 1 mg Einwaage.
Summary A rapid and simple micromethod was developed for the detection of several hetero-elements in organic compounds. After breaking down the sample with metallic potassium, the resulting ions are separated by the ring oven method and detected by means of sensitive reagents. Detection limits: 0.5 to 1g nitrogen, 1 to 2g sulfur, 2 to 3g iodine, 4 to 5g bromine, 5 to 10g chlorine in samples weighing 0.5 to 1 mg.

Résumé On a découvert un procédé à l'échelle micro, simple et rapide, pour rechercher certains hétéroéléments dans les composés organiques. Après mise en solution par le potassium métallique, on sépare les ions formés suivant la méthode du four annulaire et l'on effectue la recherche au moyen de réactions sensibles. Limite de dilution: 0,5 à 1g d'azote, 1 àg de soufre, 2 àg d'iode, 5 à 10g de chlore sur 0,5 à 1 mg de prise d'essai.
  相似文献   

3.
Summary Spots of citrinin, ochratoxin A, aflatoxin M1 and penicillic acid on thin-layer chromatograms can be semi-quantitatively estimated by using a grey scale, commonly used in photo laboratories. The detection limits are 0.01 g for citrinin, 0.006 g for ochratoxin A, 0.002 g for aflatoxin M1 and 0.01 g for penicillic acid. Standard curves for these mycotoxins are given.
Halbquantitative Bestimmung der Mycotoxine Citrinin, Ochratoxin A, Aflatoxin M1 und Penicillinsäure auf Dünnschicht-Chromatogrammen mit Hilfe eines Graukeils
Zusammenfassung Mit Hilfe eines in Photolabors gebräuchlichen Graukeils können dünnschicht-chromatographische Flecke der obengenannten Mycotoxine halbquantitativ bestimmt werden. Die Nachweisgrenzen betragen 0,01 g für Citrinin, 0,006 g für Ochratoxin A, 0,002 g für Aflatoxin M1 und 0,01 g für Penicillinsäure. Eichkurven werden angegeben.
  相似文献   

4.
The dependence of the state of boron atoms on the preparation conditions of borosilicates and the effect of this state on their catalytic properties in methanol conversion have been studied.
, .
  相似文献   

5.
Fluoride and sulphate complexing of Np(VI) has been studied by controlled-potential coulometry at a constant ionic strength. The values of 1 * and 2 * for fluoride complexes were found to be 9.4 and 8.9, respectively, at an ionic strength =0.5. At an ionic strength =1.0, 1 * and 2 * obtained were 6.6 and 10.5, respectively. Sulphate complexing of Np(VI) was studied only at an ionic strength =0.5. The value of 1 * obtained was 5.6.  相似文献   

6.
Summary A simple and fast determination of trace amounts of commercially used cationic surfactants is described. After extraction from water cationic surfactants are separated by HPLC and detected by conductometry. The detection limit is 3 g/l for distearyldimethylammonium chloride, 16 g/l for ditallowimidazolinium methosulphate, and 6 g/l for dodecylpyridinium chloride.  相似文献   

7.
A procedure was developed for the gas-chromatographic determination of promedol (trimeperidine) and ketamine in whole blood with mass-selective detection. The detection limit for trimeperidine and ketamine in blood is 0.05 g/mL. The analytical range is 0.1–5.0 g/mL. The maximum within-series errors in the determination of the studied compounds are no higher than 14.1% for concentrations of 0.10 g/mL and 7.47% for concentrations of 1.0 g/mL. The maximum between-series relative errors are 5.75% for concentrations of 0.10 g/mL and 2.7% for concentrations of 1.0 g/mL. The procedure can be used in toxicological and clinical analyses.  相似文献   

8.
The kinetics of the gas phase pyrolysis of ethyl fluoroacetate have been measured over the temperature range of 340–365 °C and pressure range of 66–187 Torr. The reaction, in a static system seasoned with allyl bromide, and in the presence or absence of propene inhibitor, is homogeneous, unimolecular, and obeys a first-order rate law. The temperature dependence of the rate coefficients is given by the following Arrhenius equation: log k1 (sec–1)=(12.57±0.26)–(194.0±3.1 kJ/mol)/2.303 RT. The result of this work confirms that the sequence of the -halo substituent effects follows the order of their electronegativity differences.
340–365 °C 66–187 . , , , , . ; log k1 (cek–1)=(12,57±0,26) –(194,0±3,1) //2,303RT. - .
  相似文献   

9.
A method for the determination of aldrin, dieldrin, DDT, DDE, and DDD contamination in animal fats (beef tallow, lard, and chicken fat) without using toxic reagents is developed, that uses high-performance liquid chromatography after the sample has been prepared by matrix solid-phase dispersion (MSPD) with acidic alumina oxide. A reversed-phase C1-silica column with a mobile phase of 50% (v/v) ethanol solution (in water) and a photo-diode array detector were used for the determination. Average recoveries of the target compounds (0.2–5.0 g g–1) ranged from 84–98%, with coefficients of variation of <5%. The limits of quantitation were 0.16 g g–1 for AD, 0.10 g g–1 for DD, 0.06 g g–1 for DDT, 0.07 g g–1 for DDE, and 0.05 g g–1 for DDD. No toxic reagents were used at all.  相似文献   

10.
Zusammenfassung Staub- und Aerosolproben werden im Stickstoffstrom im Temperaturbereich 25–420° C einer temperaturprogrammierten thermischen Desorption unterworfen. Die flüchtigen organischen Komponenten werden mittels FID summarisch als volatile organic carbon (VOC) bestimmt. Die Eichung des Analysators erfolgt durch ein Aliphaten-Standardgemisch. Bei Probemengen von 50–100g Aerosol ist eine Bestimmung des VOC-Gehaltes mit einer Reproduzierbarkeit vons=3,5–7 rel.% möglich. Die Nachweisgrenze der Methode liegt für Aerosolproben bei 0,3g VOC.
Determination of volatile organic components in atmospheric aerosol samples by thermal desorption and FID-detection
Summary Atmospheric dust and aerosol samples are treated in a nitrogen carrier gas stream at the temperature range 25–420° C by temperature programmed desorption. The volatile organic components are detected by FID. Calibration of the analyzer is carried out with a standard mixture of aliphatic hydrocarbons. The result is expressed as volatile organic carbon (VOC). The reproducibility of the method for aerosol samples (sample weight 50–100g) is in the range of 3,5–7% r. s. d. The detection limit of the method is 0,3g VOC.
  相似文献   

11.
The instrumental neutron activation analysis (INAA) Advance Prediction Computer Program (APCP) is described, as well as its areas of usefulness. Particular attention is devoted to its ability to predict g and ppm INAA lower limits of detection (LOD's) of any particular elements of interest in any sample matrix type of even very approximately known average or typical elemental composition. In general, INAA g LOD's are found to be 10 to 100 times higher than the corresponding interference-free values, and INAA ppm LOD's are found to be 100 to even 100 000 times higher than the corresponding interference-free values calculated for a one-gram sample.  相似文献   

12.
A gas-chromatographic separation procedure with mass-spectrometric detection was developed for the detection of opiates in whole blood and the quantitative determination of morphine and codeine as their propionic esters. The detection limit for morphine and codeine in blood was 0.02 g/mL. The analytical range was 0.05–2.0 g/mL. The maximum intraseries relative errors were 15.6 and 11.2% for concentrations of 0.05 and 1.0 g/mL, respectively. The interseries relative errors were no higher than 8 and 3% for concentrations of 0.05 and 1.0 g/mL, respectively. The procedure is intended for forensic chemical analysis in cases of opiate poisoning.  相似文献   

13.
A simple, precise, sensitive and accurate method was developed for rapid determination of trace quantities of periodate. The method is based on the accelerating effect of periodate on the reaction of bromate and hydrochloric acid in the presence of hydrazine. The decolorization of methyl orange with the reaction products was used to monitor the reaction spectrophotometrically at 525 nm. Periodate could be determined in the concentration ranges of 0.02–1.5 g/mL. The relative standard deviation for ten replicate determinations of 0.3 g/mL of periodate was 1.12%. The method was applied to the determination of periodate in water samples and indirect determination of ethylene glycol in gasoline and glycerol in vegetable oil via Malaprade reaction with satisfactory results.  相似文献   

14.
The absorption spectra of 4f electron transitions of the complexes of neodymium and erbium with 5,7-dibromo-8-hydroxyquinoline in the presence of octylphenol poly(ethyleneglycol)ether have been studied by normal and third-derivative spectrophotometry. The proposed method is free of interference of other rare earths. The calibration graphs were linear up to 18 g/ml of neodymium and 21 g/ml of erbium (in the final solution). The derivative molar absorptivities are 395 l.mol–1.cm–1 for neodymium and 3421.mol–1.cm–1 for erbium. The corresponding values of Sandell's sensitivity were 0.36 and 0.49 g.cm–1, respectively. The relative standard deviations evaluated from ten independent determinations of 2.5 g/ml of neodymium and erbium are 1.5 and 3.8% for neodymium and 1.8 and 4.1% for erbium in absence and presence of 70 g of lanthanum, respectively. The detection limits (signal to noise ratio=2) are 0.23 g/ml for neodymium and 0.30 g/ml for erbium. The method has been used for the determination of neodymium and erbium in mixed rare earths with satisfactory results.  相似文献   

15.
In a long-term field study at two locations with different air pollution levels several soot-selective measurement techniques were compared with a thermochemical method which measures non-extractable carbon (NEC) detecting the evolved CO2 by means of coulometric titration. The attenuation measurement technique (aethalometer) and the aerosol photoemission method showed good correlations to NEC for concentrations ranging from 1.6g/m3 to 40.8g/m3. The specific mass absorption coefficient of black carbon with respect to NEC varied between 8.4m2/g and 13.7m2/g with respect to the measurement sites, but the value was found to remain constant at each site independent of seasonal or meteorological variations. The ratio of photoelectric signal to NEC varied between 16 fA·(g/m3)–1 and 33 fA·(g/m3)–1 depending on the age of the aerosol. The diurnal variations of that ratio showed strong similarities to the traffic patterns. Additionally a slight temperature dependence of this ratio was found for the aged aerosol with a proportionality factor of – 0.35 fA·(K·g/m3)–1. With the reflectance measurement technique (smoke shade method) reliable NEC determination was not possible for NEC concentrations 5 g/m3.  相似文献   

16.
Summary Five isomers present in technical benzene hexachloride were successfully separated by TLC on silica-gel G impregnated with silver nitrate solution. The -isomer was identified by running a control sample of -BHC. Measurement of the spot area was found suitable for the estimation of 5–20g of-BHC, and was applied to analysis of autopsy tissues. The limit of identification is 0.1g.
Zusammenfassung Auf mit Silbernitratlösung imprägniertem Kieselgel G konnten dünn-schichtchromatographisch fünf Isomere aus technischem Hexachlorbenzol erfolgreich getrennt werden. Das-Isomere wurde mit Hilfe einer Vergleichsprobe identifiziert. Die Planimetrie der Flecken eignet sich zur Schätzung von 5–20 g-Hexachlorbenzol. Die Methode wurde zur Untersuchung von Autopsieproben angewendet. Die Nachweisgrenze beträgt 0,1g.
  相似文献   

17.
Working conditions were found for determining the novocaine salt of benzylpenicillin antibiotic as its 4,6-dinitrobenzofuroxan derivative by flow-injection analysis with spectrophotometric detection ( = 510 nm). The best results were obtained for flows of methanol (ethanol) and water with a volume ratio of 30 : 70. The calibration range of the pharmaceutical is 0.28–10 g/mL with a throughput capacity of 30 samples/h. The limit of detection (3, n= 4) is 0.14 g/mL. Amino acids and components of penicillin-containing pharmaceuticals did not interfere with the determination. Procedures for determining benzylpenicillin novocaine salt in medicinal formulations containing benzylpenicillin N,N"-dibenzylethylenediamine, potassium, and sodium salts and some other  相似文献   

18.
The interference contributions of uranium and thorium to the determination of cerium based on radionuclides141Ce and143Ce produced by irradiation in a reactor core was determined. The values of the interference contributions for141Ce were 0.28±0.01 g Ce/g U and /2.01±0.05/x10–3 g Ce/g Th, and for143Ce 1.33±0.03 g Ce/g U and /9.0±0.2/x10–3 g Ce/g Th.  相似文献   

19.
Xu  Feng  Sun  Wen-Hua  Yang  Shi-Yan  Yin  Yan-Qi  Wu  Qin-Jin  Yu  Kai-Bei 《Transition Metal Chemistry》1997,22(2):176-179
HFe2Co(CO)9(3-S) reacts with (5-Cp)Mo(CO)3Cl in refluxing THF to give heterometallic trinuclear clusters (5-Cp)MoFeCo(CO)8(3-S) and [(5-Cp)Mo]2Fe(CO)7-(3-S), which have been characterized by elemental analyses, i.r., 1H- and 13C-n.m.r. and X-ray crystal structure determination. An electrophilic addition–elimination sequence is proposed for their formation.  相似文献   

20.
The absorption spectra of 4f electron transitions of the systems of neodymium and erbium with 2-isobutylformyl-1,3-dione-indane and TX-100 have been studied by normal and derivative spectrophotometry. Their molar absorptivities at the maximum absorption bands are about 7.2 (at 571 nm) times greater for neodymium and 13.1 (at 519 nm) times greater for erbium than those in the absence of the complexing agents. Use of second derivative spectra both eliminates the interference from other rare earths and increases the sensitivity from neodymium and erbium. Beers law is obeyed from 020 g/ml for neodymium and 025 g/ml for erbium. The relative standard deviations are 1.2% and 1.6% for 5.0 g/ml of neodymium and 8.0 g/ml of erbium, respectively. The detection limits (signal-to-noise ratio=2) are 0.14 g/ml and 0.20 g/ml. A method for the direct determination of neodymium and erbium in rare earth mixtures with good accuracy and selectivity is proposed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号