首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Kuo CY  Chiou SS  Wu SM 《Electrophoresis》2006,27(14):2905-2909
This paper describes approaches for large-volume sample stacking (LVSS) with an EOF pumpin CE for the determination of methotrexate (MTX) and its metabolites in human plasma. After pretreatment of plasma through a SPE cartridge, a large sample volume was loaded by hydrodynamic injection (3 psi, 70 s) into the capillary filled with phosphate buffer (70 mM, pH 6.0) containing 0.01% polyethylene oxide. Following removal of a large plug of sample matrix from the capillary using polarity switching (-25 kV), the separation of anionic analytes was subsequently performed without changing polarity again, achieving an improvement of sensitivity of around a 100-fold. The method was applied to therapeutic drug monitoring of MTX in one acute lymphoblastic leukemia patient. This study is one of very few applications showing the feasibility of LVSS in analysis of biological samples by CE.  相似文献   

2.
A simple, efficient, and highly sensitive in-line CE method was developed for the characterization and for inhibition studies of the nucleoside-metabolizing enzymes purine nucleoside phosphorylase (PNP) and adenosine deaminase (ADA) present in membrane preparations of human 1539 melanoma cells. After filling the running buffer (50 mM borate buffer, 100 mM SDS, pH 9.10) into a fused-silica capillary (50 cm effective length × 75 μm), a large sample volume was loaded by hydrodynamic injection (5 psi, 36 s), followed by the removal of the large plug of sample matrix from the capillary using polarity switching (-20 kV). The current was monitored and the polarity was reversed when 95% of the current had been recovered. The separation of the neutral analytes (nucleosides and nucleobases) was performed by applying a voltage of 15 kV. An about 10-fold improvement of sensitivity for the five investigated analytes (adenosine, inosine, adenine, hypoxanthine, xanthine) was achieved by large-volume stacking with polarity switching when compared with CE without stacking. For inosine and adenine detection limits as low as 60 nM were achieved. To the best of our knowledge, this represents the highest sensitivity for nucleoside and nucleobase analysis using CE with UV detection reported so far. The Michaelis-Menten constants (K(m)) for PNP and ADA and the inhibition constants (K(i)) for standard inhibitors determined with the new method were consistent with literature data.  相似文献   

3.
This paper describes approaches for stacking large volumes of sample solutions containing a mixture of chlorophenols and chlorophenoxyacetic acids as their anions in capillary zone electrophoresis, and compares results to standard capillary electrophoresis (CE) and normal stacking modes. In order to increase the amount of sample injected beyond the optimal conditions and maintain high resolution, the sample introduction buffer must be removed after the stacking process is completed. This is achieved by pumping the sample buffer out of the column using polarity switching. Large sample volumes are loaded by hydrodynamic injection, then stacked at the injection buffer/run electrolyte interface, followed by the removal of the large plug of low-conductivity sample matrix from the capillary column using polarity switching and finally the separation of the stacked anions in a basic buffer (pH 8.65). Around 10- and 40-fold improvement of sensitivity was achieved by normal stacking and large-volume stacking with polarity switching, respectively, when compared to the standard CE analysis. Sweeping-micellar electrokinetic capillary chromatography (MEKC) was also investigated for the purpose of comparison to the stacking technique. The method should be suitable for the analysis of these chemical compound classes in industrial chlorophenoxyacetic acid manufacture.  相似文献   

4.
Almeda S  Arce L  Valcárcel M 《Electrophoresis》2008,29(14):3074-3080
A reliable MEKC method for the identification and quantitation of traces of the nonsteroidal anti-inflammatory drugs (NSAIDs) ketoprofen, fenbufen and indomethacin in saliva is proposed. Using CE to analyze biological samples often requires suppressing the interferences and peak broadening typically resulting from high-conductivity sample matrices. We addressed this problem by using Microcon, a centrifugal filter device, to reduce the viscosity of saliva and exclude most higher-molecular-mass substances. This initial pretreatment was followed by the combined used of off-line SPE to isolate and concentrate the analytes, and large-volume stacking with polarity switching (LVSS) in the capillary. These two preconcentration steps allow the determination of NSAIDs at concentrations above 0.1 microg/L; therefore, the proposed SPE/LVSS/MEKC method affords a 500-fold sensitivity enhancement relative to conventional CE injection. The LODs obtained afford the determination of NSAIDs in saliva, where analytes can be present at the microgram-per-liter level.  相似文献   

5.
《Analytical letters》2012,45(18):2853-2867
Abstract

A capillary electrophoresis method with large volume sample stacking (CE-LVSS) has been developed and validated for the simultaneous determination of seven phenolic compounds: naringin, rutin, carnosic acid, apigenin, quercetin, morin, and chichoric acid. Optimization was carried out by response surface methodology and a set of 20 experiments helped to optimize the parameters such as the concentration of buffer, buffer pH, and applied voltage. Analytes were separated using a 50?µm diameter capillary with 56?cm effective length and an extended light path using 20?mM borate buffer at pH 9.2. The LVSS method was optimized and a three- to fivefold improvement in detectability was achieved with injection at 100 mbar for 20?s followed by polarity switching at –20?kV for 6?s. The linearity values of all seven analytes were observed in the concentration ranges from 0.5 to 50?µg/mL for CE and 0.1 to 25?µg/mL for LVSS. The limits of detection were from 0.012 to 0.241 and 0.003 to 0.086?µg/mL for CE and LVSS. The obtained limits of quantitation were within 0.041 to 0.802 for CE and 0.012 to 0.286?µg/mL for LVSS. The recoveries were between 91.1 and 109.8% and 96.3 and 108.4% for CE and LVSS, respectively. The developed method has been successfully applied for the quantitative determination of analyzed components from food samples that are important sources of these compounds.  相似文献   

6.
In capillary electrophoresis, the short optical path length associated with on-column UV detection imposes an inherent detection problem. Detection limits can be improved using sample stacking. Recently, large-volume sample stacking (LVSS) without polarity switching was demonstrated to improve detection limits of charged analytes by more than 100-fold. However, this technique requires suppression of the electroosmotic flow (EOF) during the run. This necessitates working at a low pH, which limits using pH to optimize selectivity. We demonstrate that LVSS can be performed at any buffer pH (4.0-10.0) if the zwitterionic surfactant Rewoteric AM CAS U is used to suppress the EOF. Sensitivity enhancements of up to 85-fold are achieved with migration time, corrected area, and peak height reproducibility of 0.8-1.6%, 1.3-3.7%, and 0.8-4.9%, respectively. Further, it is possible to stack either positively or negatively charged analytes using zwitterionic surfactants to suppress the EOF.  相似文献   

7.
On-line preconcentration methods for capillary electrophoresis   总被引:3,自引:0,他引:3  
Osbourn DM  Weiss DJ  Lunte CE 《Electrophoresis》2000,21(14):2768-2779
The limits of detection (LOD) for capillary electrophoresis (CE) are constrained by the dimensions of the capillary. For example, the small volume of the capillary limits the total volume of sample that can be injected into the capillary. In addition, the reduced pathlength hinders common optical detection methods such as UV detection. Many different techniques have been developed to improve the LOD for CE. In general these techniques are designed to compress analyte bands within the capillary, thereby increasing the volume of sample that can be injected without loss of CE efficiency. This on-line sample preconcentration, generally referred to as stacking, is based on either the manipulation of differences in the electrophoretic mobility of analytes at the boundary of two buffers with differing resistivities or the partitioning of analytes into a stationary or pseudostationary phase. This article will discuss a number of different techniques, including field-amplified sample stacking, large-volume sample stacking, pH-mediated sample stacking, on-column isotachophoresis, chromatographic preconcentration, sample stacking for micellar electrokinetic chromatography, and sweeping.  相似文献   

8.
Zhang H  Zhou L  Chen X 《Electrophoresis》2008,29(7):1556-1564
An easy, simple, and highly efficient on-line preconcentration method for polyphenolic compounds in CE was developed. It combined two on-line concentration techniques, large-volume sample stacking (LVSS) and sweeping. The analytes preconcentration technique was carried out by pressure injection of large-volume sample followed by the EOF as a pump pushing the bulk of low-conductivity sample matrix out of the outlet of the capillary without the electrode polarity switching technique using five polyphenols as the model analytes. Identification and quantification of the analytes were performed by photodiode array UV (PDA) detection. The optimal BGE used for separation and preconcentration was a solution composed of 10 mM borate-90 mM sodium cholate (SC)-40% v/v ethylene glycol, without pH adjustment, the applied voltage was 27.5 kV. Under optimal preconcentration conditions (sample injection 99 s at 0.5 psi), the enhancement in the detection sensitivities of the peak height and peak area of the analytes using the on-line concentration technique was in the range of 18-26- and 23-44-fold comparing with the conventional injection mode (3 s). The detection limits for (-)-epigallocatechin (EGC), (-)-epicatechin (EC), (+)-catechin (C), (-)-epigallocatechin gallate (EGCG), and (-)-epicatechin gallate (ECG) were 4.3, 2.4, 2.2, 2.0, and 1.6 ng/mL, respectively. The five analytes were baseline-separated under the optimum conditions and the experimental results showed that preconcentration was well achieved.  相似文献   

9.
Nucleotide pyrophosphatase/phosphodiesterase 1 (NPP1) is a membrane glycoprotein involved in the hydrolysis of extracellular nucleotides. Its main substrate is ATP yielding AMP and pyrophosphate. NPP1 has been proposed as a novel drug target, for diabetes type 2 and the treatment of calcium pyrophosphate dihydrate deposition disease leading to inflammatory arthritis. The monitoring of NPP1 reactions is difficult because its velocity is very slow requiring highly sensitive analytical procedures. In this study, a method of large‐volume sample stacking with polarity switching was developed, and separations were optimized. Large sample volumes were loaded by hydrodynamic injection (5 psi, 13 s) followed by removal of a large plug of sample matrix from the capillary using polarity switching (?10 kV). The stacked analytes were subsequently separated in phosphate buffer (100 mM, pH 9.2) at 20 kV. The validated method was found to be linear (R2 = 0.9927) in the concentration range of 0.05–50 μM of AMP, with high accuracy and precision. The determined LOD and LOQ of AMP were 18 nM and 60 nM, respectively. Compared to a previously reported CE procedure using sweeping technique, a fivefold improvement of sensitivity was achieved. Moreover, the new technique was faster, and reproducibility of migration times was improved (RSD value = 1.2%). Importantly, adenine nucleotide analogs and derivatives tested as NPP1 inhibitors could be completely separated from the substrate ATP and the enzymatic product AMP. The method was applied to NPP1 inhibition assays investigating nucleotide‐derived inhibitors in the presence of ATP.  相似文献   

10.
This study systematically investigates the optimal conditions for analyzing the positional isomers of multi-charged naphthalenesulfonate compounds by cyclodextrin-mediated capillary electrophoresis (CE). Specifically, this work employs large-volume sample injection with the electrode polarity switching technique. The most effective separation and sample stacking conditions were 15 mM borate buffer with a mixture of beta- and gamma-cyclodextrin (concentration ratio 3:7 mM) at pH 9.2, and the sample hydrodynamic injection of up to 60 s at 3 p.s.i. (around 1.8 microl, and 1 p.s.i. = 6.9 kPa). Significantly selective and sensitive improvements were observed and a more than 100-fold enrichment was achieved (based on peak area). The reproducibility of migration time and quantitative results of stacking CE can be improved by using an internal standard. The quantitation limits of these naphthalenesulfonate isomers, based on a signal-to-noise ratio above 10, can be about 4 microg/l with UV detection. This method was successfully applied to determine the trace amount of naphthalenesulfonate isomers in a spiked drinking water sample.  相似文献   

11.
Sun B  Macka M  Haddad PR 《Electrophoresis》2003,24(12-13):2045-2053
Stacking techniques used independently and also with a high-sensitivity cell (HSC) were employed to optimise sensitivity and detection limits in the direct photometric detection of the following eight arsenic species by capillary zone electrophoresis (CZE): arsenite, arsenate, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), 4-hydroxy-3-nitrophenylarsonic acid (Roxarsone), p-aminophenylarsonic acid (p-ASA), 4-nitrophenylarsonic acid (4-NPAA), and phenylarsonic acid (PAA) (target analytes). The stacking mechanisms, optimised stacking and separation conditions, and concentration sensitivity enhancement factors were discussed and compared for (i) normal stacking mode (NSM, sometimes also referred to as field-amplified stacking) in an uncoated fused-silica capillary in the counter-electroosmotic flow (EOF) mode, (ii) large-volume sample stacking (LVSS) with polarity switching, and (iii) the less often applied stacking method of co-EOF NSM stacking with EOF reversal using a poly(diallydimethylammonium chloride) (PDDAC)-coated capillary. The optimal injection volumes were 7.4, 60 and 17.2% of the total capillary volume, for the above three methods, respectively. LVSS with polarity switching gave the lowest limit of detection (LOD). The use of the HSC further reduced the LOD of each target analytes by a factor of 5-8 times. By combining LVSS and HSC, LODs of the target analytes could be reduced by a factor of 218-311, to 5.61, 9.15, 11.1, and 17.1 microg/L for As(III), DMA, MMA, and As(V), respectively. The method was demonstrated to be applicable to the determination of the target analytes in tap water and lake water, with recoveries in the range of 89.4-103.3%.  相似文献   

12.
Kim B  Chung DS 《Electrophoresis》2002,23(1):49-55
Highly sensitive nonaqueous capillary electrophoresis of weakly acidic organic compounds has been performed using methanol as the run buffer solvent. Methanol provided appropriate suppression of the electroosmotic flow and an increase in the electrophoretic mobilities of anionic solutes compared to water. These two effects allowed large-volume stacking using the electroosmotic flow pump (LVSEP) to be achieved for larger anions using a bare fused-silica capillary under an electric field of reverse polarity, whereas only fast-moving small anions were previously known to be suitable for LVSEP in aqueous media. A field-enhanced sample injection of an additional amount of analytes during the solvent plug removal further enhanced the limits of detection to below the nanomolar range with conventional UV absorption detection. Under optimum conditions, excellent linear responses and reproducibility in the migration times together with the corrected peak areas for ten analytes were obtained in the concentration range of 10-100 nM.  相似文献   

13.
Liu FK 《Analytica chimica acta》2011,694(1-2):167-173
In this study, gold nanoparticles (Au NPs) were separated using the reversed electrode polarity stacking mode (REPSM) of a capillary electrophoresis (CE) system for on-line enhancement prior to performing surfactant-modified CE separation. Under optimized conditions [running electrolyte buffer, sodium dodecyl sulfate (70 mM) and 3-cyclohexylamino-1-propanesulfonic acid (10 mM) at pH 10.0; applied voltage, 20 kV; operating temperature, 25°C; REPSM strategy for sample on-line concentration; REPSM applied prior to initializing separation], two parameters were varied to further enhance the concentration and separation of the Au NPs: (i) the rate of polarity switching (from -20 to +20 kV) between the REPSM and surfactant-modified CE separation modes and (ii) the length of the capillary column. At a polarity switching rate of 1333 kV min(-1) and a column length of ca. 83.5 cm, the resolution of the separation of a mixture of 5.3- and 40.1-nm Au NPs was greater than 19; in addition, the numbers of theoretical plates for the 5.3- and 40.1-nm-diameter Au NPs were greater than 15,000 and up to 1.15×10(7), respectively-the latter being extremely high. Thus, this CE-based method for separating Au NPs provided high performance in terms of separation resolution and the number of theoretical plates, both of which were improved by greater than fivefold relative to those published previously. Notably, the sensitivity enhancement factors for the 5.3- and 40.1-nm-diameter Au NPs were improved (by ca. 20- and 500-fold, respectively) relative to those obtained using conventional surfactant-modified CE separation.  相似文献   

14.
Simultaneous enantioseparation with sensitive detection of four basic drugs, namely methoxamine, metaproterenol, terbutaline and carvedilol, using a 20-mum ID capillary with native beta-CD as the chiral selector was demonstrated by the large-volume sample stacking method. The procedure included conventional sample loading either hydrodynamically or electrokinetically at longer injection times without polarity switching and EOF manipulation. In comparison to conventional injections, depending on the analyte, about several hundred- and a thousand-fold sensitivity enhancement was achieved with the hydrodynamic and the electrokinetic injections, respectively. The simple method developed was applied to the analysis of racemic analytes in serum samples and better recovery was achieved using hydrodynamic injection than electrokinetic injection.  相似文献   

15.
In order to improve the concentration sensitivity of capillary electrophoresis (CE), two sample preconcentration techniques, single drop microextraction (SDME) and large volume stacking using an electroosmotic flow pump (LVSEP), were coupled in-line in a commercial CE instrument. By simple programming of liquid handling sequences, a pentanol drop was prepared at the tip of a fused silica capillary over which a Teflon tube had been sleeved to serve as a hydrophobic support. After extraction of the analytes from an aqueous donor solution into the drop, the entire capillary column was filled with enriched pentanol extract. LVSEP, in which the sample matrix is automatically removed by the EOF, was then carried out using a methanolic run buffer. The overall enrichment factors for the analytes pentachlorophenol (PCP), 3-bromobenzoic acid (3-BBA), and 4-iodobenzoic acid (4-IBA), from a combination of 30 min SDME and LVSEP on a 27 cm capillary, were about 7000, even without agitation of the donor solution. The resulting limits of detection for PCP, 3-BBA, and 4-IBA were 0.7, 0.3 and 0.7 nM, respectively. Since no modification of the existing CE instrument is necessary and a bare capillary is used for LVSEP, this scheme can be adapted quite easily for many CE applications that require high concentration sensitivity.  相似文献   

16.
We present a new system for the sensitive analysis of cephalosporins by CE using both on-line SPE and large-volume sample stacking (LVSS). Sample volumes of 250 muL were loaded onto the SPE microcolumn which was then desorbed with 426 nL of ACN. The SPE elution plug was injected into the CE system via an in-line valve interface filling approximately 60% of the volume of the separation capillary. Subsequently, LVSS was performed by applying a voltage of -5 kV, which resulted in the simultaneous removal of the elution solvent and the preconcentration of the analytes in a narrow zone. This way the amount of analyte loaded into the capillary could be considerably increased without serious loss of CE separation efficiency. LODs for cefoperazone and ceftiofur were in the ng/L range which represents an improvement of a factor of 8450 and 11 450 when compared with direct CE injection. The cephalosporin test compounds presented a good linear response (corrected peak area) between 0.5 and 10 mug/L with correlation coefficients higher than 0.995. The final method is compared with previously reported LVSS-CE and SPE-CE systems for the analysis of cephalosporins.  相似文献   

17.
Non-aqueous capillary electrophoresis (NACE) with large-volume sample stacking injection using the electroosmotic flow pump (LVSEP) has been developed for the determination of tetrabromobisphenol A (TBBPA) and other phenolic compounds in environmental matrices. Methanol has been used as run buffer solvent to reduce the electroosmotic flow (EOF). Identification and quantification of the analytes was performed by photodiode array ultraviolet detection. LVSEP-NACE improved sensitivity of the peak height by 90-300-fold. The method developed was applied to the analysis of TBBPA in river water and wastewater samples, using solid-phase extraction (SPE) as sample pretreatment process. The average recoveries of the analytes were in the range of 96-106% and 73-103% for 1 L of river water and 0.5 L of wastewater samples, respectively. When the method was based on off line SPE-LVSEP-NACE, sensitivity was improved by 3300-4500-fold and 1600-2200-fold for river water and wastewater samples, respectively.  相似文献   

18.
Experimental studies document that increased asymmetric dimethylarginine (ADMA) blood levels inhibit NOS significantly, reducing NO generation. ADMA measurement often needs sample cleanup by SPE prior to chromatography and precolumn derivatization that cannot be easily employed in a routine clinical setting. We set up a new reliable CE method to measure ADMA, symmetric dimethylarginine (SDMA), and arginine without sample extraction or precolumn derivatization in order to examine their concentrations in human plasma. Sample was concentrated prior to CE injection and analytes were monitored by UV detection. CE analysis was performed in an uncoated fused-silica capillary, 75 microm id and 60.2 cm length (50 cm to the detection window), injecting 1 s water plug (0.5 psi) followed by 10 s of the sample (0.5 psi). Separation was carried out in a 50 mmol/L Tris-phosphate run buffer at pH 2.30, 15 degrees C and 15 kV (75 microA) at normal polarity. Recovery of plasma ADMA was 101-104% and inter-day CV was less than 3%. Assay performance was evaluated measuring the levels of arginine and its dimethyl derivatives in 77 subjects. Passing-Bablok regression and Bland-Altman test for methods comparison suggest that the data obtained by our method and by a reference CE-LIF assay are similar.  相似文献   

19.
In this work, we overcame the deficiencies of large volume sample stacking (LVSS) in separating low‐mobility and neutral analytes through combining LVSS with sweeping in CE, and employed this new approach to enrich and separate neutral and anionic analytes simultaneously. This technique was carried out with pressure injection of large‐volume sample followed by EOF as a pump pushing the bulk of low‐conductivity sample matrix out of the outlet of the capillary while analytes were swept by micelles and separated via MEKC without the electrode polarity switching. Careful optimization of the enrichment and separation conditions allowed the enrichment factors (EFs) of peak height and peak area of the analytes to be in the range of 9–33 and 21–35 comparing with the conventional injection mode, respectively. The five analytes were baseline separated in 15 min and the detection limits ranged from 26.5 to 55.8 ng/mL (S/N = 3). The developed method was successfully applied to determine adenine, caffeine, theophylline, reduced L‐glutathione (GSH) and oxidized L‐glutathione (GSSG) in two different teas with recoveries that ranged from 84.4 to 105.2%.  相似文献   

20.
A fast and simple method for the direct, simultaneous detection of nitrite (NO(2) (-)) and nitrate (NO(3) (-)) in rat striatum has been developed using a capillary electrophoresis separation of low-flow push-pull perfusion samples. The method was optimized primarily for nitrite because nitrite is more important physiologically and is found at lower levels than nitrate. We obtained a complete separation of NO(2) (-) and NO(3) (-) in rat striatum within 1.5 min. Optimal CE separations were achieved with 20 mM phosphate, 2 mM cetyltrimethylammonium chloride (CTAC) buffer at pH 3.5. The samples were injected electrokinetically for 2 s into a 40 cm x 75 microm ID fused-silica capillary. The separation voltage was 10 kV (negative polarity), and the injection voltage was 16 kV (negative polarity). UV detection was performed at 214 nm. The limits of detection obtained at a signal-to-noise ratio (S/N) of 3 for nitrite and nitrate were 0.96 and 2.86 microM. This is one of the fastest separations of nitrite and nitrate of a biological sample ever reported. Interference produced by the high physiological level of chloride is successfully minimized by use of CTAC in the run buffer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号