首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Polychromatic synchrotron undulator X‐ray sources are useful for ultrafast single‐crystal diffraction under shock compression. Here, simulations of X‐ray diffraction of shock‐compressed single‐crystal tantalum with realistic undulator sources are reported, based on large‐scale molecular dynamics simulations. Purely elastic deformation, elastic–plastic two‐wave structure, and severe plastic deformation under different impact velocities are explored, as well as an edge release case. Transmission‐mode diffraction simulations consider crystallographic orientation, loading direction, incident beam direction, X‐ray spectrum bandwidth and realistic detector size. Diffraction patterns and reciprocal space nodes are obtained from atomic configurations for different loading (elastic and plastic) and detection conditions, and interpretation of the diffraction patterns is discussed.  相似文献   

2.
This work reports a harmonic‐rejection scheme based on the combination of Si(111) monochromator and Si(220) harmonic‐rejection crystal optics. This approach is of importance to a wide range of X‐ray applications in all three major branches of modern X‐ray science (scattering, spectroscopy, imaging) based at major facilities, and especially relevant to the capabilities offered by the new diffraction‐limited storage rings. It was demonstrated both theoretically and experimentally that, when used with a synchrotron undulator source over a broad range of X‐ray energies of interest, the harmonic‐rejection crystals transmit the incident harmonic X‐rays on the order of 10?6. Considering the flux ratio of fundamental and harmonic X‐rays in the incident beam, this scheme achieves a total flux ratio of harmonic radiation to fundamental radiation on the order of 10?10. The spatial coherence of the undulator beam is preserved in the transmitted fundamental radiation while the harmonic radiation is suppressed, making this scheme suitable not only for current third‐generation synchrotron sources but also for the new diffraction‐limited storage rings where coherence preservation is an even higher priority. Compared with conventional harmonic‐rejection mirrors, where coherence is poorly preserved and harmonic rejection is less effective, this scheme has the added advantage of lower cost and footprint. This approach has been successfully utilized at the ultra‐small‐angle X‐ray scattering instrument at the Advanced Photon Source for scattering, imaging and coherent X‐ray photon correlation spectroscopy experiments. With minor modification, the harmonic rejection can be improved by a further five orders of magnitude, enabling even more performance capabilities.  相似文献   

3.
An in‐vacuum undulator (IVU) with a tapered configuration was installed in the 8C nanoprobe/XAFS beamlime (BL8C) of the Pohang Light Source in Korea for hard X‐ray nanoprobe and X‐ray absorption fine‐structure (XAFS) experiments. It has been operated in planar mode for the nanoprobe experiments, while gap‐scan and tapered modes have been used alternatively for XAFS experiments. To examine the features of the BL8C IVU for XAFS experiments, spectral distributions were obtained theoretically and experimentally as functions of the gap and gap taper. Beam profiles at a cross section of the X‐ray beam were acquired using a slit to visualize the intensity distributions which depend on the gap, degree of tapering and harmonic energies. To demonstrate the effect of tapering around the lower limit of the third‐harmonic energy, V K‐edge XAFS spectra were obtained in each mode. Owing to the large X‐ray intensity variation around this energy, XAFS spectra of the planar and gap‐scan modes show considerable spectral distortions in comparison with the tapered mode. This indicates that the tapered mode, owing to the smooth X‐ray intensity profile at the expense of the highest and most stable intensity, can be an alternative for XAFS experiments where the gap‐scan mode gives a considerable intensity variation; it is also suitable for quick‐XAFS scanning.  相似文献   

4.
X‐ray scattering from a liquid using the spectrum from the undulator fundamental is examined as a function of the bandwidth of the spectrum. The synchrotron‐generated X‐ray spectrum from an undulator is `pink', i.e. quasi‐monochromatic but having a saw‐tooth‐shaped spectrum with a bandwidth from 1 to 15%. It is shown that features in S(q) are slightly shifted and dampened compared with strictly monochromatic data. In return, the gain in intensity is 250–500 which makes pink beams very important for time‐resolved experiments. The undulator spectrum is described by a single exponential with a low‐energy tail. The tail shifts features in the scattering function towards high angles and generates a small reduction in amplitude. The theoretical conclusions are compared with experiments. The r‐resolved Fourier transformed signals are discussed next. Passing from q‐ to r‐space requires a sin‐Fourier transform. The Warren convergence factor is introduced in this calculation to suppress oscillatory artifacts from the finite qM in the data. It is shown that the deformation of r‐resolved signals from the pink spectrum is small compared with that due to the Warren factor. The q‐resolved and the r‐resolved pink signals thus behave very differently.  相似文献   

5.
A phase‐merging enhanced harmonic generation free‐electron laser (FEL) was proposed to increase the harmonic conversion efficiency of seeded FELs and promote the radiation wavelength towards the X‐ray spectral region. However, this requires a specially designed transverse gradient undulator (TGU) as the modulator to couple the transverse and longitudinal phase space of the electron beam. In this paper, the generation of the phase‐merging effect is explored using the natural field gradient of a normal planar undulator. In this method, a vertical dispersion on the electron beam is introduced and then the dispersed beam travels through a normal modulator in a vertical off‐axis orbit where the vertical field gradient is selected properly in terms of the vertical dispersion strength and modulation amplitude. The phase‐merging effect will be generated after passing through the dispersive chicane. Theoretical analysis and numerical simulations for a seeded soft X‐ray FEL based on parameters of the Shanghai Soft X‐ray FEL project are presented. Compared with a TGU modulator, using the natural gradient of a normal planar modulator has the distinct advantage that the gradient can be conveniently tuned in quite a large range by adjusting the beam orbit offset.  相似文献   

6.
Under the experimental condition that all Bragg peaks in a powder X‐ray diffraction (PXRD) pattern have the same shape, one can readily obtain the Bragg intensities without fitting any parameters. This condition is fulfilled at the P02.1 beamline at PETRA III using the seventh harmonic from a 23 mm‐period undulator (60 keV) at a distance of 65 m. For grain sizes of the order of 1 µm, the Bragg peak shape in the PXRD is entirely determined by the diameter of the capillary containing the powder sample and the pixel size of the image plate detector, and consequently it is independent of the scattering angle. As an example, a diamond powder has been chosen and structure factors derived which are in accordance with those calculated from density functional theory methods of the WIEN2k package to within an accuracy that allows a detailed electron density analysis.  相似文献   

7.
A new method of harmonics rejection based on X‐ray refractive optics has been proposed. Taking into account the fact that the focal distance of the refractive lens is energy‐dependent, the use of an off‐axis illumination of the lens immediately leads to spatial separation of the energy spectrum by focusing the fundamental harmonic at the focal point and suppressing the unfocused high‐energy radiation with a screen absorber or slit. The experiment was performed at the ESRF ID06 beamline in the in‐line geometry using an X‐ray transfocator with compound refractive lenses. Using this technique the presence of the third harmonic has been reduced to 10?3. In total, our method enabled suppression of all higher‐order harmonics to five orders of magnitude using monochromator detuning. The method is well suited to third‐generation synchrotron radiation sources and is very promising for the future ultimate storage rings.  相似文献   

8.
X‐ray absorption and scattering spectroscopies involving the 3d transition‐metal K‐ and L‐edges have a long history in studying inorganic and bioinorganic molecules. However, there have been very few studies using the M‐edges, which are below 100 eV. Synchrotron‐based X‐ray sources can have higher energy resolution at M‐edges. M‐edge X‐ray absorption spectroscopy (XAS) and resonant inelastic X‐ray scattering (RIXS) could therefore provide complementary information to K‐ and L‐edge spectroscopies. In this study, M2,3‐edge XAS on several Co, Ni and Cu complexes are measured and their spectral information, such as chemical shifts and covalency effects, are analyzed and discussed. In addition, M2,3‐edge RIXS on NiO, NiF2 and two other covalent complexes have been performed and different dd transition patterns have been observed. Although still preliminary, this work on 3d metal complexes demonstrates the potential to use M‐edge XAS and RIXS on more complicated 3d metal complexes in the future. The potential for using high‐sensitivity and high‐resolution superconducting tunnel junction X‐ray detectors below 100 eV is also illustrated and discussed.  相似文献   

9.
Calculations are presented of the electronic structure and X‐ray spectra of materials with correlated d‐ and f‐electron states based on the Hubbard model, a real‐space multiple‐scattering formalism and a rotationally invariant local density approximation. Values of the Hubbard parameter are calculated ab initio using the constrained random‐phase approximation. The combination of the real‐space Green's function with Hubbard model corrections provides an efficient approach to describe localized correlated electron states in these systems, and their effect on core‐level X‐ray spectra. Results are presented for the projected density of states and X‐ray absorption spectra for transition metal‐ and lanthanide‐oxides. Results are found to be in good agreement with experiment.  相似文献   

10.
BioCARS, a NIH‐supported national user facility for macromolecular time‐resolved X‐ray crystallography at the Advanced Photon Source (APS), has recently completed commissioning of an upgraded undulator‐based beamline optimized for single‐shot laser‐pump X‐ray‐probe measurements with time resolution as short as 100 ps. The source consists of two in‐line undulators with periods of 23 and 27 mm that together provide high‐flux pink‐beam capability at 12 keV as well as first‐harmonic coverage from 6.8 to 19 keV. A high‐heat‐load chopper reduces the average power load on downstream components, thereby preserving the surface figure of a Kirkpatrick–Baez mirror system capable of focusing the X‐ray beam to a spot size of 90 µm horizontal by 20 µm vertical. A high‐speed chopper isolates single X‐ray pulses at 1 kHz in both hybrid and 24‐bunch modes of the APS storage ring. In hybrid mode each isolated X‐ray pulse delivers up to ~4 × 1010 photons to the sample, thereby achieving a time‐averaged flux approaching that of fourth‐generation X‐FEL sources. A new high‐power picosecond laser system delivers pulses tunable over the wavelength range 450–2000 nm. These pulses are synchronized to the storage‐ring RF clock with long‐term stability better than 10 ps RMS. Monochromatic experimental capability with Biosafety Level 3 certification has been retained.  相似文献   

11.
The layout and the characteristics of the hard X‐ray beamline BL10 at the superconducting asymmetric wiggler at the 1.5 GeV Dortmund Electron Accelerator DELTA are described. This beamline is equipped with a Si(111) channel‐cut monochromator and is dedicated to X‐ray studies in the spectral range from ~4 keV to ~16 keV photon energy. There are two different endstations available. While X‐ray absorption studies in different detection modes (transmission, fluorescence, reflectivity) can be performed on a designated table, a six‐axis kappa diffractometer is installed for X‐ray scattering and reflectivity experiments. Different detector set‐ups are integrated into the beamline control software, i.e. gas‐filled ionization chambers, different photodiodes, as well as a Pilatus 2D‐detector are permanently available. The performance of the beamline is illustrated by high‐quality X‐ray absorption spectra from several reference compounds. First applications include temperature‐dependent EXAFS experiments from liquid‐nitrogen temperature in a bath cryostat up to ~660 K by using a dedicated furnace. Besides transmission measurements, fluorescence detection for dilute sample systems as well as surface‐sensitive reflection‐mode experiments are presented.  相似文献   

12.
An end‐station for X‐ray Raman scattering spectroscopy at beamline ID20 of the European Synchrotron Radiation Facility is described. This end‐station is dedicated to the study of shallow core electronic excitations using non‐resonant inelastic X‐ray scattering. The spectrometer has 72 spherically bent analyzer crystals arranged in six modular groups of 12 analyzer crystals each for a combined maximum flexibility and large solid angle of detection. Each of the six analyzer modules houses one pixelated area detector allowing for X‐ray Raman scattering based imaging and efficient separation of the desired signal from the sample and spurious scattering from the often used complicated sample environments. This new end‐station provides an unprecedented instrument for X‐ray Raman scattering, which is a spectroscopic tool of great interest for the study of low‐energy X‐ray absorption spectra in materials under in situ conditions, such as in operando batteries and fuel cells, in situ catalytic reactions, and extreme pressure and temperature conditions.  相似文献   

13.
GAPD, a graphics‐processing‐unit (GPU)‐accelerated atom‐based polychromatic diffraction simulation code for direct, kinematics‐based, simulations of X‐ray/electron diffraction of large‐scale atomic systems with mono‐/polychromatic beams and arbitrary plane detector geometries, is presented. This code implements GPU parallel computation via both real‐ and reciprocal‐space decompositions. With GAPD, direct simulations are performed of the reciprocal lattice node of ultralarge systems (~5 billion atoms) and diffraction patterns of single‐crystal and polycrystalline configurations with mono‐ and polychromatic X‐ray beams (including synchrotron undulator sources), and validation, benchmark and application cases are presented.  相似文献   

14.
Ru/C multilayer monochromators with different periodic thicknesses were investigated using X‐ray grazing‐incidence reflectivity, diffuse scattering, Bragg imaging, morphology testing, etc. before and after cryogenic cooling. Quantitative analyses enabled the determination of the key multilayer structural parameters for samples with different periodic thicknesses, especially the influence from the ruthenium crystallization. The results also reveal that the basic structures and reflection performance keep stable after cryogenic cooling. The low‐temperature treatment smoothed the surfaces and interfaces and changed the growth characteristic to a low‐frequency surface figure. This study helps with the understanding of the structure evolution of multilayer monochromators during cryogenic cooling and presents sufficient experimental proof for using cryogenically cooled multilayer monochromators in a high‐thermal‐load undulator beamline.  相似文献   

15.
X‐ray scattering of biological macromolecules in solution is an increasingly popular tool for structural biology and benefits greatly from modern high‐brightness synchrotron sources. The upgraded MacCHESS BioSAXS station is now located at the 49‐pole wiggler beamline G1. The 20‐fold improved flux over the previous beamline F2 provides higher sample throughput and autonomous X‐ray scattering data collection using a unique SAXS/WAXS dual detectors configuration. This setup achieves a combined q‐range from 0.007 to 0.7 Å?1, enabling better characterization of smaller molecules, while opening opportunities for emerging wide‐angle scattering methods. In addition, a facility upgrade of the positron storage ring to continuous top‐up mode has improved beam stability and eliminated beam drift over the course of typical BioSAXS experiments. Single exposure times have been reduced to 2 s for 3.560 mg ml?1 lysozyme with an average quality factor I/σ of 20 in the Guinier region. A novel disposable plastic sample cell design that incorporates lower background X‐ray window material provides users with a more pristine sample environment than previously available. Systematic comparisons of common X‐ray window materials bonded to the cell have also been extended to the wide‐angle regime, offering new insight into best choices for various q‐space ranges. In addition, a quantitative assessment of signal‐to‐noise levels has been performed on the station to allow users to estimate necessary exposure times for obtaining usable signals in the Guinier regime. Users also have access to a new BioSAXS sample preparation laboratory which houses essential wet‐chemistry equipment and biophysical instrumentation. User experiments at the upgraded BioSAXS station have been on‐going since commissioning of the beamline in Summer 2013. A planned upgrade of the G1 insertion device to an undulator for the Winter 2014 cycle is expected to further improve flux by an order of magnitude.  相似文献   

16.
The performance of a cooled Be compound refractive lens (CRL) has been tested at the Advanced Photon Source (APS) to enable vertical focusing of the pink beam and permit the X‐ray beam to spatially overlap with an 80 µm‐high low‐density plasma that simulates astrophysical environments. Focusing the fundamental harmonics of an insertion device white beam increases the APS power density; here, a power density as high as 500 W mm?2 was calculated. A CRL is chromatic so it does not efficiently focus X‐rays whose energies are above the fundamental. Only the fundamental of the undulator focuses at the experiment. A two‐chopper system reduces the power density on the imaging system and lens by four orders of magnitude, enabling imaging of the focal plane without any X‐ray filter. A method to measure such high power density as well as the performance of the lens in focusing the pink beam is reported.  相似文献   

17.
The optical design of a two‐dimensional imaging soft X‐ray spectrometer is described. A monochromator will produce a dispersed spectrum in a narrow vertical illuminated stripe (~2 µm wide by ~2 mm tall) on a sample. The spectrometer will use inelastically scattered X‐rays to image the extended field on the sample in the incident photon energy direction (vertical), resolving the incident photon energy. At the same time it will image and disperse the scattered photons in the orthogonal (horizontal) direction, resolving the scattered photon energy. The principal challenge is to design a system that images from the flat‐field illumination of the sample to the flat field of the detector and to achieve sufficiently high spectral resolution. This spectrometer provides a completely parallel resonant inelastic X‐ray scattering measurement at high spectral resolution (~30000) over the energy bandwidth (~5 eV) of a soft X‐ray absorption resonance.  相似文献   

18.
The high‐brilliance X‐ray beams from undulator sources at third‐generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a `standard' beam from an undulator source, ~25–50 µm (FWHM) in the vertical and 50–100 µm in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID‐13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA‐CAT) dual canted undulator beamlines at the APS deliver high‐intensity focused beams with a minimum focal size of 20 µm × 65 µm at the sample position. To meet growing user demand for beams to study samples of 10 µm or less, a `mini‐beam' apparatus was developed that conditions the focused beam to either 5 µm or 10 µm (FWHM) diameter with high intensity. The mini‐beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward‐ and back‐scatter guards. A unique triple‐collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini‐beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid‐exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.  相似文献   

19.
A practical method for operating existing undulator synchrotron beamlines at photon energies considerably higher than their standard operating range is described and applied at beamline 19‐ID of the Structural Biology Center at the Advanced Photon Source enabling operation at 30 keV. Adjustments to the undulator spectrum were critical to enhance the 30 keV flux while reducing the lower‐ and higher‐energy harmonic contamination. A Pd‐coated mirror and Al attenuators acted as effective low‐ and high‐bandpass filters. The resulting flux at 30 keV, although significantly lower than with X‐ray optics designed and optimized for this energy, allowed for accurate data collection on crystals of the small protein crambin to 0.38 Å resolution.  相似文献   

20.
In this article the calculation of brightness and flux for two insertion devices of the 2.8 GeV X‐ray storage ring at the NSLS is discussed. The radiation properties from the X25 linearly polarized wiggler and the new X25 short‐period undulator are compared at a fixed photon energy (11.3 keV) corresponding to emission from the fifth harmonic of the short‐period undulator. For this computation, three commonly available synchrotron radiation programs are used. The capabilities of each of these codes are briefly discussed, and their range of applicability are commented on. It is concluded that special care is needed when modeling the radiation of the classes of insertion devices considered here.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号