首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Module giving IBM PC format of the EPR spectra recorded by Bruker ER 420 and ER 200D-SRC spectrometers is described. The files thus stored may be used for post-acquisition spectral processing using any program for this purpose and any IBM compatible PC.  相似文献   

2.
将ER-200D ESR波谱仪ASPECT 3000计算机采集的ESR图谱传输到IBM PC/XT计算机上,通过自行设计的ESR图谱模拟程序ESRSIMU,同屏显示比较,方便、灵活地对多自由基体系溶液ESR一级近似谱进行了模拟,获取了各个自由基的ESR波谱参数和体系中各类自由基的相对浓度等信息.对单个自由基ESR谱的模拟,ESRSIMU的运行速度比BRUKER EPR 3002快近100倍.  相似文献   

3.
We describe the design of a pulsed electron nuclear double resonance (ENDOR) spectrometer operating at Q-band frequencies (35 GHz) for studies of transition metal ion complexes in the temperature range between 4.2 and 297 K. Specific features of the spectrometer are a microwave IMPATT generator, a homebuilt cavity, and a commercial Bruker magnet. Standard Davies and Mims ENDOR sequences have been implemented. The performance of the spectrometer is demonstrated for a broad radio frequency range by1H,14N,31P,133Cs, and207Pb pulsed ENDOR experiments of Cu2+, Cr5+, and V4+ transition metal ion complexes in both single crystals and disordered materials.  相似文献   

4.
本文设计了Jarrell-Ash96—866型电感耦合氩等离子炬光电直读光谱仪与IBMPC286微型计算机的接口适配电路,用汇编语言编写了相应的支持程序,从而实现了该光谱仪由DECPDP8A向IBMPC286的计算机换型改造。  相似文献   

5.
We describe a frequency tunable Q-band cavity (34 GHz) designed for CW and pulse Electron Paramagnetic Resonance (EPR) as well as Electron Nuclear Double Resonance (ENDOR) and Electron Electron Double Resonance (ELDOR) experiments. The TE(011) cylindrical resonator is machined either from brass or from graphite (which is subsequently gold plated), to improve the penetration of the 100 kHz field modulation signal. The (self-supporting) ENDOR coil consists of four 0.8mm silver posts at 2.67 mm distance from the cavity center axis, penetrating through the plunger heads. It is very robust and immune to mechanical vibrations. The coil is electrically shielded to enable CW ENDOR experiments with high RF power (500 W). The top plunger of the cavity is movable and allows a frequency tuning of ±2 GHz. In our setup the standard operation frequency is 34.0 GHz. The microwaves are coupled into the resonator through an iris in the cylinder wall and matching is accomplished by a sliding short in the coupling waveguide. Optical excitation of the sample is enabled through slits in the cavity wall (transmission ~60%). The resonator accepts 3mm o.d. sample tubes. This leads to a favorable sensitivity especially for pulse EPR experiments of low concentration biological samples. The probehead dimensions are compatible with that of Bruker flexline Q-band resonators and it fits perfectly into an Oxford CF935 Helium flow cryostat (4-300 K). It is demonstrated that, due to the relatively large active sample volume (20-30 μl), the described resonator has superior concentration sensitivity as compared to commercial pulse Q-band resonators. The quality factor (Q(L)) of the resonator can be varied between 2600 (critical coupling) and 1300 (over-coupling). The shortest achieved π/2-pulse durations are 20 ns using a 3 W microwave amplifier. ENDOR (RF) π-pulses of 20 μs ((1)H @ 51 MHz) were obtained for a 300 W amplifier and 7 μs using a 2500 W amplifier. Selected applications of the resonator are presented.  相似文献   

6.
A microcomputer sytem based on an Apple IIe and an IBM PC/XT computers is described. The system can complete the data-acquisition, fitting and plotting Mössbauer spectra with enough accuracy speed.  相似文献   

7.
A four-phase percolation problem is used to simulate the Josephson model for high-temperature superconductivity both as a four-phase and a three-phase system. We implement the method on an IBM PC microcomputer using PASCAL language.  相似文献   

8.
An easy to assemble and inexpensive PC card that interfaces E-Line Varian spectrometers (E-6, E-9, E-12 and E-15) with IBM compatible PCs is presented. The card has a Programmable Interval Timer so it does not need an external clock making it instrument independent. The accessory contains its own RAM. This allows the device to store the spectrum while sampling is in progress, so the PC can meanwhile be used for any other task.  相似文献   

9.
10.
A new transient variation of the “Feher-style” electron-nuclear double resonance (ENDOR) method is examined. In this technique, the passage-mode electron paramagnetic resonance (EPR) signal is monitored following the application of a pulsed radio frequency (RF). Continuous-wave and transient proton ENDOR experiments have been conducted on the nonheme iron center from the protein nitrile hydratase. These experiments show that the transient ENDOR signal response exhibits a complex response with multiple phases in the time evolution of the ENDOR signal. Both increases and decreases in the passage-mode EPR signals are observed at different times following the RF pulse that induces an ENDOR transition. A simple model based on a packet-shifting ENDOR mechanism for a nonadiabatic passage EPR signal is proposed. This model describes many of the features seen in the transient ENDOR experiments and provides new insight into the traditional Feher-style ENDOR measurements. This new model shows that a packet-shifting mechanism can account for many of the “negative ENDOR” effects commonly seen in Feher-style ENDOR, which suggests that more exotic ENDOR mechanisms may not be required to explain these observations.  相似文献   

11.
The underlying causes of asymmetric intensities in Davies pulsed ENDOR spectra that are associated with the signs of the hyperfine interaction are reinvestigated. The intensity variations in these asymmetric ENDOR patterns are best described as shifts in an apparent baseline intensity that occurs dynamically following on-resonance ENDOR transitions. We have developed an extremely straightforward multi-sequence protocol that is capable of giving the sign of the hyperfine interaction by probing a single ENDOR transition, without reference to its partner transition. This technique, Pulsed ENDOR Saturation and Recovery (PESTRE) monitors dynamic shifts in the 'baseline' following measurements at a single RF frequency (single ENDOR peak), rather than observing anomalous ENDOR intensity differences between the two branches of an ENDOR response. These baseline shifts, referred to as dynamic reference levels (DRLs), can be directly tied to the electron-spin manifold from which that ENDOR transition arises. The application of this protocol is demonstrated on (57)Fe ENDOR of a 2Fe-2S ferredoxin. We use the (14)N ENDOR transitions of the S = 3/2[Fe(II)NO](2+) center of the non-heme iron enzyme, anthranilate dioxygenase (AntDO) to examine the details of the relaxation model using PESTRE.  相似文献   

12.
This paper presents a quasi-optical resonator that design methode basic on IBM PC computer (CAD). There is an exellent method to calculate global optima of the fundamental mode power, fractional power of the fundamental mode and combining efficiency etc. It also presents a process of CAD of microcomputer.  相似文献   

13.
A two-dimensional (2D) experiment that correlates electron-nuclear double resonance (ENDOR) and electron spin-echo envelope modulation (ESEEM) frequencies, useful for unraveling and assigning ENDOR and ESEEM spectra from different paramagnetic centers with overlapping EPR spectra, is presented. The pulse sequence employed is similar to the Davies ENDOR experiment with the exception that the two-pulse echo detection is replaced by a stimulated echo detection in order to enhance the resolution in the ESEEM dimension. The two-dimensional data set is acquired by measuring the ENDOR spectrum as a function of the time interval T between the last two microwave pulses of the stimulated echo detection scheme. This produces a series of ENDOR spectra with amplitudes that are modulated with T. Fourier transformation (FT) with respect to T then generates a 2D spectrum with cross peaks connecting spectral lines of the ESEEM and ENDOR spectra that belong to the same paramagnetic center. Projections along the vertical and horizontal axes give the three-pulse FT-ESEEM and ENDOR spectra, respectively. The feasibility of the experiment was tested by simulating 2D ENDOR-ESEEM correlation spectra of a system consisting of an electron spin (S = (1/2)) coupled to two nuclei (I(1) = I(2) = (1/2)), taking into account experimental conditions such as pulse durations and off-resonance irradiation frequencies. The experiment is demonstrated on a single crystal of Cu(2+) doped l-histidine (Cu-His), containing two symmetrically related Cu(2+) sites that at an arbitrary orientation exhibit overlapping ESEEM and ENDOR spectra. While the ESEEM spectrum is relatively simple and arises primarily from one weakly coupled (14)N, the ENDOR spectrum is very crowded due to contributions from two nonequivalent nitrogens, two chlorides, and a relatively large number of protons. The simple ESEEM projection of the 2D ENDOR-ESEEM correlation spectrum is then used to disentangle the ENDOR spectrum and resolve two sets of lines corresponding to the different sites. Copyright 2000 Academic Press.  相似文献   

14.
Multiple resonance methods are important tools in EPR for revealing the network of hyperfine levels of free radicals and paramagnetic centers. The variations of electron nuclear double resonance (ENDOR) or electron spin-echo envelope modulation (ESEEM) techniques help to correlate nuclear frequencies with each other. These methods have limited utility when there is extensive overlap or suspected overlap in the EPR spectrum between different species or different orientations. In the ENDOR spectrum, overlap and second-order shifts of lines also leads to ambiguity in assignment and interpretation. A new electron nuclear multiple resonance method is presented here that is based on population transfer ENDOR. It is a quadruple resonance method that correlates ENDOR lines and reveals the network of hyperfine levels in samples with unoriented paramagnetic species and in samples with overlapping EPR or ENDOR lines.  相似文献   

15.
ENDOR experiments on coals recorded using continuous wave (CW) and pulsed techniques appear to give qualitatively different spectra. A matrix proton signal dominates the ENDOR spectrum of coals recorded in the CW ENDOR experiment while both a matrix and local proton ENDOR signals with huperfine couplings of up to 20 MHz are observed in spectra recorded using pulsed excitation techniques. Analysis of these spectra lead to different implications for the structure of the molecules that host the unpaired electron. Using a combination of pulsed EPR (Electron Spin Echo, FID detected hole burning) and pulsed Electron Nuclear Multiple Resonance (Sub-level relaxation, hyperfine selective ENDOR, EPR sub-spectra) experiments, we investigate the electron and nuclear spin dynamics in order to reconcile the different signal amplitudes observed in the CW and pulsed ENDOR spectra. In the CW ENDOR experiment, the results of the FID detected hole burning experiments prove that the low ENDOR signal intensity can not be attributed to spectral diffusion mechanisms competing with ENDOR mechanisms. Instead, we find that an unfavorable ratio of the electron and nuclear spin relaxation rates results in small local ENDOR signals. The matrix line dominates the spectrum because of the large number of matrix protons. In the pulsed ENDOR experiment, the hyperfine contrast selectivity mechanism suppresses the intensity of the matrix ENDOR signal and enhances the amplitudes of the local ENDOR signals. In addition, the ENDOR signal is not a function of the ratio of the electron and nuclear relaxation rates.  相似文献   

16.
The origin of frequently observed “negative” (opposite phase) ENDOR lines in the low-frequency region of triplet state ENDOR spectra is explained in terms of microwave hole burning and RF modulation phenomena. From this, a new method of detecting burnt side holes in EPR spectra is derived which is based on cw ENDOR instrumentation. The method uses the modulation satellites that are induced by a longitudinal RF field component and appear around any EPR line, including burnt holes (“negative” lines). The longitudinal RF field was generated by a coil oriented parallel to the external field, but a longitudinal component of the RF field also exists in most conventional ENDOR spectrometers because of slight misalignments of the ENDOR coil generating the transversal RF field. The lines it induces in the low-frequency part of ENDOR spectra are generally considered as artifacts. It is shown, however, that RF induced modulation satellites provide valuable information concerning the lines distant from the spectral position in the EPR spectrum chosen for ENDOR observation. This allows one to record the pattern of side holes burnt by microwave saturation through forbidden transitions that carries information about ENDOR frequencies comparable to what can be extracted from ESEEM experiments. Such comparability is demonstrated for examples of nitrogen ENDOR of photoexcited triplet states of the primary donor in photosynthetic reaction centers and related compounds.  相似文献   

17.
An analytical expression of the transmission coefficient for the electron transport through a triangular potential barrier has been modified for solution using the method of numerical simulation. The triangular potential barrier has been modelled as a staircase function. The performance of this numerical simulation method is briefly described. The simulation has been developed for personal computer IBM PC AT.  相似文献   

18.
For the analysis of the angular dependence of electron paramagnetic resonance (EPR) spectra of low-symmetry centres with S=1/2 in three independent planes, it is well-established-but often overlooked-that an ambiguity may arise in the best-fit g<--> tensor result. We investigate here whether a corresponding ambiguity also arises when determining the hyperfine coupling (HFC) A<--> tensor for nuclei with I=1/2 from angular dependent electron nuclear double resonance (ENDOR) measurements. It is shown via a perturbation treatment that for each set of M(S) ENDOR branches two best-fit A<--> tensors can be derived, but in general only one unique solution simultaneously fits both. The ambiguity thus only arises when experimental data of only one M(S) multiplet are used in analysis or in certain limiting cases. It is important to realise that the ambiguity occurs in the ENDOR frequencies and therefore the other best-fit result for an ENDOR determined A<--> tensor depends on various details of the ENDOR experiment: the M(S) state of the fitted transitions, the microwave frequency (or static magnetic field) in the ENDOR measurements and the rotation planes in which data have been collected. The results are of particular importance in the identification of radicals based on comparison of theoretical predictions of HFCs with published literature data. A procedure for obtaining the other best-fit result for an ENDOR determined A<--> tensor is outlined.  相似文献   

19.
The automatic image analysis system for scanning solid state nuclear track detectors is designed by utilizing a microdensitometer. The control of the entire system as well as the data analysis are accomplished with the IBM PC computer equipped with a FrameGrabber. The system counts the number of tracks and measures their geometrical parameters. The usage of the system is illustrated by counting rhombic tracks in mica detectors which were used for the investigation of the fusion–fission reaction 12C+ 208Pb.  相似文献   

20.
This mini-review focuses on various aspects of the application of radio frequency (rf) irradiation in electron paramagnetic resonance (EPR). The development of the electron-nuclear double resonance (ENDOR) technique is briefly described, and we highlight the use of circularly polarized rf fields and pulse ENDOR methodology in one- and two-dimensional experiments. The capability of pulse ENDOR at Q-band is illustrated with interesting experimental examples. Electron spin echo envelope modulation effects induced by an rf field in liquid samples demonstrate another role which rf fields can play. Technical achievements in the design of ENDOR resonators are illustrated by the example of a bridged loop-gap resonator. Finally, the influence of longitudinal rf fields on the dynamics of EPR transitions is explained using a dressed spin resonance treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号