首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Summary Gas chromatographic retention indices for 23 hydrocarbons were determined on BP-1 dimethylsiloxane between 45 and 65°C. From the data measured unified retention indices were calculated. These values agree well with the corresponding experimental values. The values of unified retention indices obtained on BP-1 are compared with those determined on OV-101 and on squalane. The differences between the unified and the experimental retention indices on BP-1, OV-101 and squalane columns are shown.  相似文献   

2.
Temperature-programmed gas chromatographic retention indices, relative to n-alkane and n-alkylbis(trifluoromethyl)phosphine sulphide (M-standard) homologous series, were determined for nine chemical warfare agents using SE-54 fused-silica capillary columns. The influence of changes in the chromatographic conditions on the absolute values and on the reproducibility of the indices was evaluated. Nineteen parameters were investigated, with the purpose of discovering those most critical for the retention index monitoring of chemical warfare agents. The parameters most affecting the absolute value of the indices were the carrier gas flow-rate, the temperature programming rate and the properties of the column. Changes in conditions most strongly affected the indices of the low-volatility compounds O-ethyl S-2-(diisopropylamino)ethyl methylphosphonothioate (VX) and dibenz[b,f]-1,4-oxazepin (CR). The reproducibility of the indices was good in every case, even when the absolute values of the indices changed. Retention index monitoring is thus a reliable method for preliminary identification of compounds in mixtures, provided that the chromatographic system is regularly tested with a test mixture and corrections to the chromatographic conditions or the retention index library data are made where necessary.  相似文献   

3.
A gas chromatographic system for the evaluation of linear temperature-programmed retention indices allowing n-alkanes to be adopted as the reference retention markers for any type of analyte, irrespective of the atoms present in their molecules, is described. It is based on the simultaneous use of two different detectors (a flame ionization detector and a specific detector suitable for the sample components), both connected (in parallel) to the same column outlet. The performance of this system has been tested by measuring the retention indices of fifteen chlorinated pesticides under conditions of linear programming temperature, by adopting an electron-capture detector as the specific detector. The reliability of the retention indices thus determined has been proven by verifying that they can be reproduced under different chromatographic conditions.  相似文献   

4.
Pyrolysis-capillary gas chromatography (Py-cGC) represents important method to identify the analytes in the mixture after thermal degradation. This combines high effective analyte separation on-line coupled with thermal degradation process that depends on analyte structure. System of retention indices has been used for identification of the analytes after on-line pyrolysis and chromatographic separation. The pyrolysate composition has been studied during thermal degradation of polymethylmethacrylate (PMMA) at different pyrolysis temperatures and chromatographic column conditions. Homologues series of n-alkanes have been used for calculation of pyrolysate Kováts retention indices (I) and compared with mass spectrometric (MS) data of pyrolysate model mixture. To identify PMMA thermal degradation products the high density polyethylene (HDPE) as additive standard producing triplets of the olefin homologous series during co-pyrolysis has been used. These homologous series enable to calculate programmed temperature retention indices (ITPGC) to identify the analytes present in the pyrolysate. Calculated I values were compared with published I values databases to identify analytes yielded at different pyrolysis temperatures.  相似文献   

5.
Direct conversion of isothermal to temperature programmed indices is not possible. In this work it is shown that linear temperature programmed retention indices can only be calculated from isothermal retention data if the temperature dependence of both the distribution coefficients and the column dead time are taken into account. Procedures are described which allow calculation of retention temperatures and from these, accurate programmed retention indices. Within certain limits the initial oven temperature and programming rate can be chosen freely. The prerequisite for this calculation is the availability of reliable isothermal retention data (retention times, retention factors, relative retention times, or retention indices) at two different temperatures for one column. The use of compiled isothermal retention indices at two different temperatures for the calculation of retention temperatures and thus temperature programmed indices is demonstrated. For the column for which programmed retention indices have to be determined, the isothermal retention times of the n-alkanes and the column dead time as a function of temperature have to be known in addition to the compiled data for a given stationary phase. Once the programmed retention indices have been calculated for a given column the concept allows the calculation of temperature programmed indices for columns with different specifications. The characteristics which can be varied are: column length, column inner diameter, phase-ratio, initial oven temperature, and programming rate.  相似文献   

6.
Overlapping chromatographic peaks of components from different hydrocarbon classes can be disengaged by exploiting their shifts in relative retention behavior with changes in linear rates of programmed temperature. Many co-eluting species in complex chromatograms of shale- and petroleum-derived jet fuels can be resolved without varying stationary phase, column length, or initial column temperature. Retention indices were simultaneously determined on two bonded-phase, fused silica capillary columns of slightly different polarities at three different linear programmed temperature rates. For certain hydrocarbon types, no change in index values was observed with an alteration in programming rate. However, the indices of other hydrocarbon classes shifted uniformly with programmed temperature rates on each of the two stationary phases. When applied, this phenomenon could help resolve coeluting members of different or even the same hydrocarbon type and elucidate their probable structure. The overall precision of the retention indices, i.e., the mean standard deviation at the 95% confidence levels, was less than ±0.13 for either column at any of the three programming rates. Since the above technique is automated, it could also be a useful screening tool to search for specific hydrocarbons in a myriad of unknown components of a complex hydrocarbon mixture.  相似文献   

7.
通过对184个烯烃类化合物在不同固定相不同柱温下的617个样本的气相色谱保留指数值(RI)与其部分参数:拓扑指数(mQ)、偶极矩(DPL)、固定液极性值(CP)及柱温(T)建立定量-色谱保留相关(QSRR)模型.分别利用多元线性回归(MLR)、偏最小二乘回归(PLSR)、人工神经网络(ANN)建模,同时采用内部及外部双重验证的办法对所得模型稳定性能进行深入分析和检验,建模计算值、留一法(LOO)交互检验(CV)预测值和外部样本的复相关系数Rcum,QLOO和Rext分别为0.999 2,0.998 4和0.999 2(MLR);0.999 0,0.998 0和0.999 1(PLSR);0.999 4,0.998 7和0.999 2(ANN).结果表明:所建定量结构保留关系(QSRR)模型具有良好的稳定性和预测能力,较好地揭示了烯烃类化合物在不同固定相不同柱温上气相色谱保留指数的变化规律.  相似文献   

8.
通过对部分含氧化合物(醇、酯、醛、酮)在不同固定相不同柱温下的849个样本的气相色谱保留指数值(RI)与其部分参数:拓扑指数(mQ)、定位基参数(Sox)、固定液极性值(CP)及柱温(T)建立定量结构-色谱保留相关(QSRR)模型。分别利用多元线性回归(MLR)、偏最小二乘回归(PLSR)、人工神经网络(ANN)建模,同时采用内部及外部双重验证的办法对所得模型稳定性能进行深入分析和检验,建模计算值、留一法(LOO)交互检验(CV)预测值和外部样本预测值的复相关系数Rcum、QLOO和Rext分别为0.9832、0.9829和0.9836(MLR);0.9832、0.9830和0.9836(PLSR);0.9910、0.9909和0.9900(ANN)。结果表明:所建定量结构保留关系(QSRR)模型具有良好的稳定性和预测能力,较好地揭示了含氧化合物(醇、酯、醛、酮)在不同色谱条件下气相色谱保留指数的变化规律。  相似文献   

9.
烷烃同系物气相色谱保留指数的分子拓扑研究   总被引:13,自引:0,他引:13  
定义了分子中原子的平衡电负性,并用原子的平衡电负性对分子图进行着色,在距离矩阵的基础上结合分子中各原子的支化度构建了一种新的拓扑指数N1,N2和N3。该拓扑指数对分子结构实现惟一性表征,具有优良的结构选择性。将拓扑指数N1,N2和N3与烷烃在固定相角鲨烷(柱温50 ℃)及SE-30(柱温80 ℃)上的气相色谱保留指数进行多元线性回归,结果表明烷烃的气相色谱保留指数可分别定量描述为I(Squalane)=23.97842N1-3.86562N2+0.787379N3+42.33061,I(SE-30)=23.83937N1-3.5687N2+0.939876N3+22.11952。用上述回归方程对烷烃的气相色谱保留指数进行预测,结果表明预测值与实验值的平均相对误差均为1.31%,预测结果误差在实验误差范围内。  相似文献   

10.
Increasing the interlaboratory reproducibility of gas chromatographic retention indices requires avoiding measurements distorted by overloading effects. Several criteria of evaluating the limits of the mass overloading of gas chromatographic systems are compared and reconsidered. The criteria mostly appropriate for practical purposes are based on (i) the dependences of factors of peak broadening (ratio of peak height and its width) vs. amount of analyte injected into the chromatographic column and (ii) the dependence of parameters characterizing the peak distortion (asymmetry factor) vs. the amount of analyte. Both these criteria provide mutually comparable evaluations of the overloading limits for analytes of different polarity. At the same time, the dependence of retention indices vs. amounts of analyte injected in the chromatographic column cannot be recommended for overloading control, because the parameters of the corresponding linear regressions indicate temperature dependence. The interpretation of certain gas chromatographic anomalies requires the correct evaluation of overloading limits. For example, the unusual temperature dependence of retention indices of polar analytes on non‐polar stationary phases and the dependence of retention indices on ratio of amounts of target analytes and reference compounds.  相似文献   

11.
In reversed-phase liquid chromatography (RPLC), the comparison of experimental results obtained from different columns is a complex problem. A correspondence factor analysis (CFA) and a linear solvation energy relationship (LSER) were applied on retention data to characterize second-order intermolecular interactions responsible for retention on a set of RPLC columns. Seven octadecyl-C18 columns with different packing materials are obtained from different manufacturers and one octyl-C8 column. The retention data were determined under isocratic conditions using a methanol–water (65:35, v/v) mobile phase. The chromatographic retention indices based on alkan-2-ones and alkyl aryl ketones retention index scales are calculated using a multiparametric least-squares regressions iterative method. The CFA and LSER results permitted to highlight that the retention indices were appropriate for studying the second-order retention mechanisms on the eight chromatographic systems investigated and exhibited the best reproducibility. Although many earlier studies have reported the use of chemometric methods to characterize chemical factors affecting retention in RPLC using retention factors as retention parameters, this is the first study based on retention indices.  相似文献   

12.

Isothermal retention indices (I) at 333–413 K on 12 stationary phases (SPs) covering a wide polarity range of a variety of volatile solutes belonging to 7 one-heteroatom chemical function series and 10 non-series solutes have been determined. The I values were computed with a method (LQG method) which does not require the determination of holdup times of the chromatographic column. I values of some compounds never before studied are reported. The influence on the retention indices of the column temperature, methylene number, and polarity of both the stationary phase and the solute has been studied. The solvation parameter model (SPM) as a function of I has been used for predicting I values, and for unraveling the influence of the polarity of stationary phase and solute on the retention indices. Seeley et al.’s formulation of the SPM has been used for quantifying the influence of polar and non-polar interactions on the I, and for checking the agreement between calculated and experimental values. According to our results, the I values obtained by the modified SPM can be considered equal to the experimental I values at the 99 % confidence level.

  相似文献   

13.
G&#;rg&#;nyi  M.  Fekete  Z.  Seres  L. 《Chromatographia》1989,27(11):581-584
Chromatographia - The gas chromatographic retention indices of some typicaltrans-diazenes were determined on a methyl silicone capillary column. Thetrans-diazenes are less strongly retained than...  相似文献   

14.
Tables of relative retention times, retention indices or emergence temperatures obtained under one set of chromatographic conditions can be used for the tentative identification of unknowns determined under an entirely different set of conditions. This can be accomplished for a particular liquid phase if the emergence temperature of a reference compound is maintained while one or more chromatographic parameters are changed to compensate for the changes in other parameters. The advantage of using proximal standards for the determination of both relative retention times and emergence temperatures is demonstrated in this report.  相似文献   

15.
Retention indices were evaluated for one hundred most commonly reported essential oil compounds in gas chromatography (GC) using a large retention index database. Retention data are presented for three types of stationary phases: dimethyl silicone, dimethyl silicone with 5% phenyl groups, and polyethylene glycol stationary phases. The data evaluations are based on the treatment of multiple measurements with the number of data records ranging between 30 and 470 per compound. Data distribution analysis was limited to temperature programming conditions. Data reported include the most probable value of retention index, average and median values, standard deviation, and confidence intervals. The values of most probable retention indices correspond to frequently used GC conditions of measurements (temperature program, column parameters, gas flow conditions). The results are compared with data from several available retention index collections.  相似文献   

16.
建立了用硅胶整体柱和直接电导检测的离子对色谱快速分析碘离子的方法。采用Chromolith Speed ROD RP-18e色谱柱,以氢氧化四丁铵(离子对试剂)-邻苯二甲酸+乙腈(有机改进剂)为淋洗液,讨论了离子对试剂浓度、有机改进剂浓度、pH、流速和色谱柱温度对碘离子保留的影响。确定最佳色谱条件为:0.25 mmol/L氢氧化四丁铵-0.18 mmol/L邻苯二甲酸+体积分数7%乙腈(pH5.5)作为淋洗液,流速6.0 mL/min,色谱柱温30℃。在此条件下,碘离子的保留时间在0.5 min之内,其它常见阴离子(Cl-、NO3-、SO42-)及SCN-、ClO4-不干扰测定。方法的检出限为0.86 mg/L,标准曲线的线性范围为1.6~85.0 mg/L,峰面积的相对标准偏差为2.3%。将方法应用于测定地下水和果汁中的碘离子,加标回收率为98.5%~104.2%。  相似文献   

17.
Zusammenfassung Durch mathematische Modellierung und Parameterschätzung lassen sich aus isotherm bestimmten Retentionsindices und ihrem Temperaturgang sowie aus wenigstens drei Stützwerten einer aktuellen temperaturprogrammierten Ánalyse Bruttoretentionszeiten weiterer Komponenten vorausberechnen. Am Beispiel einer mit Methylsilikonöl OV-1 imprägnierten Glaskapillarsäule wird gezeigt, daß für 19 Parametersätze mit Variation von Trägergasvordruck, isothermer Vorlaufzeit, Temperaturanstieg und isothermer Nachlauftemperatur die Bruttoretentionszeiten von 28 Komponenten einer Benzinprobe mit mittleren relativen Gesamtfehlern zwischen 1,3% und 3,8% je Analyse erhalten werden konnten.
Prediction of retention times in temperature-programmed gas chromatography from isothermally determined retention indices and adjustment using experimental values of retention times
Summary Mathematical modelling and parameter estimation from three or more reference values in an actual temperature-programmed gas chromatographic analysis allows the prediction of retention times of the other components from a knowledge of their isothermally determined retention indices and the temperature profile. It is shown using a glass capillary column coated with OV-1 for measuring 19 sets of parameters obtained by varying the carrier gas inlet pressure, pre-program time, rate of temperature rise and past-program time, that the retention times of 28 components of a gasoline sample can be predicted with a mean error lying between 1,3% and 3.8% for each of these 19 analyses.
  相似文献   

18.
The (subcooled) liquid vapour pressure, heat of vapourization and gas-liquid heat capacity difference of monoterpenes and biogenically related compounds were determined by a gas-liquid chromatographic method based on Kovats retention indices. Compared to those used in previous studies using the same method, these compounds are structurally diverse and have relatively low boiling points. Despite of this and even though the difference in activity coefficients in the chromatographic column stationary phase between the test and reference compounds were ignored, results for vapour pressure compare favorably with experimental literature data. The results indicate that the method can be improved by introducing temperature dependent activity coefficients, preferably based on a physicochemical model for gas-liquid partitioning.  相似文献   

19.
The retention behavior of components analyzed by chromatography varies with instrumental settings. Being able to predict how changes in these settings alter the elution pattern is useful, both with regards to component identification, as well as with regards to optimization of the chromatographic system. In this work, it is shown how experimental designs can be used for this purpose. Different experimental designs for response surface modeling of the separation of fatty acid methyl esters (FAME) as function of chromatographic conditions in GC have been evaluated. Full factorial, central composite, Doehlert and Box-Behnken designs were applied. A mixture of 38 FAMEs was separated on a polar cyanopropyl substituted polysilphenylene-siloxane phase capillary column. The temperature gradient, the start temperature of the gradient, and the carrier gas velocity were varied in the experiments. The modeled responses, as functions of chromatographic conditions, were retention time, retention indices, peak widths, separation efficiency and resolution between selected peak pairs. The designs that allowed inclusion of quadratic terms among the predictors performed significantly better than factorial design. Box-Behnken design provided the best results for prediction of retention, but the differences between the central composite, Doehlert and Box-Behnken designs were small. Retention indices could be modeled with much better accuracy than retention times. However, because the errors of predicted tR of closely eluting peaks were highly correlated, models of resolution (Rs) that were based on retention time had errors in the same range as corresponding models based on ECL.  相似文献   

20.
The influence of the mobile phase composition and column temperature on the chromatographic separation of five buckminsterfullerenes (C60, C70, C76, C78, C84) on a stationary phase based on silica gel with chemically bonded humic acid (Bonded humic acid column (BHAC)) was studied. The retention behavior of the fullerenes was measured under isocratic conditions with different mobile phase compositions, ranging from 0.05-0.70 (v/v) of toluene in cyclohexane. The column temperature was analysed in the range 35-75 °C. The retention factors of the five fullerenes do not depend linearly on the toluene fraction but follow a quadratic relationship. The best chromatographic conditions for baseline separation of the five fullerenes were selected. The retention of the fullerenes on the HA stationary phase was strongly affected by temperature. Positive values of thermodynamic parameters (changes of enthalpy and entropy) were due to the abnormal solubility behaviour of fullerenes in toluene in the temperature range 35-75 °C. The information obtained in this work makes this BHAC very simple to prepare and low cost, useful for fullerene research applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号