首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The diffuse fronts and sharp rears of peaks of nitrobenzene (nbz) solubilized at high concentrations in 50 mM SDS and 2.5, 25, and 50 mM sodium tetraborate buffers were modeled in MEKC by measurements of, and fits to, concave upward isotherms, and by numerical solution of the continuity equation. The isotherms varied with buffer concentration, with the smallest limiting slope and largest curvature found for the 50 mM tetraborate buffer. The Brunauer, Emmett, and Teller isotherm described the peak profiles in all buffers, with symmetrical peaks observed at sub- and low-mM levels of nbz, anti-Langmuirian peaks observed at 10-20 mM levels, and aquiline peaks resembling curved noses observed at 20-30 mM levels. The variation of the partition coefficient with nbz and buffer concentrations was shown to result from nonideal thermodynamics. High-buffer concentrations salt out nbz from the mobile phase, as quantified by a mobile-phase activity coefficient related to the Setchenov constant of nbz in sodium tetraborate. The activity coefficient of nbz in SDS micelles was shown to resemble that measured by other researchers for benzene in micelles of sodium octyl sulfate, i.e. it decreases with increasing solute concentration and increases with electrolyte concentration. Many examples from the literature are discussed, in which the variation of the intramicellar activity coefficient with solute mole fraction is consistent with peaks having diffuse fronts and sharp rears.  相似文献   

2.
This paper describes the characterization of procyanidin mixtures by acid depolymerization in the presence of cysteine (thiolysis with cysteine) and micellar electrokinetic chromatography (MEKC). Reversed-phase liquid chromatography (RP-HPLC) and MEKC were investigated for the separation of the major components of the depolymerized mixtures (catechins and their cysteinyl derivatives). The solutes could only be effectively separated using MEKC. Two background electrolytes (BGEs) are recommended: (i) 50 mM phosphate at pH 7, containing 40 mM sodium cholate (SC) and 10 mM sodium dodecyl sulfate (SDS); (ii) a BGE with the same composition but containing only 50 mM SDS. The MEKC procedures here reported, are cheap, reliable and fast, and their potential in the determination of the size and composition in procyanidin mixtures has been shown. The proposed MEKC methods were validated by comparison with our intralaboratory reference RP-HPLC method using cysteamine as thiol donor.  相似文献   

3.
Gotti R  Fiori J  Mancini F  Cavrini V 《Electrophoresis》2004,25(18-19):3282-3291
Modified micellar electrokinetic chromatography (MEKC) analysis of monomeric flavanols (catechin and epicatechin) and methylxanthines (caffeine and theobromine) in chocolate and cocoa was performed by using sodium dodecyl sulfate (SDS) as a principal component of the running buffer. Because of the reported poor stability of catechins in alkaline solutions, acidic conditions (pH 2.5) were chosen and consequently the electroosmotic flow (EOF) was significantly suppressed; this resulted in a fast anodic migration of the analytes partitioned into the SDS micelles. Under these conditions, variations of either pH value in acidic range or SDS concentration, showed to be not suitable to modulate the selectivity. To overcome this limit, use of additives to the SDS-based running buffer was successfully applied and three different systems were optimized for the separation of (+)-catechin, (-)-epicatechin, caffeine, and theobromine in chocolate and cocoa powder samples. In particular, two mixed micelle systems were applied; the first consisted of a mixture of SDS and 3-[(3-cholamidopropyl)dimethylammonio]-1-propansulfonate (CHAPS) with a composition of 90 mM and 10 mM, respectively; the second was SDS and taurodeoxycholic acid sodium salt (TDC) with a composition of 70 mM and 30 mM, respectively. A further MEKC approach was developed by addition of 10 mM hydroxypropyl-beta-cyclodextrin (HP-beta-CD) to the SDS solution (90 mM); it provided a useful cyclodextrin(CD)-modified MEKC. By applying the optimized conditions, different separation profiles of the flavanols and methylxanthines were obtained showing interesting potential of these combined systems; their integrated application showed to be useful for the identification of the low level of (+)-catechin in certain real samples. The CD-MEKC approach was validated and applied to the determination of catechins and methylxanthines in aqueous extracts from four different commercial chocolate types (black and milk) and two cocoa powders.  相似文献   

4.
The operating parameters that affect the performance of the online preconcentration technique “analyte focusing by micelle collapse‐MEKC (AFMC‐MEKC)” were examined using a multivariate approach involving experimental design to determine the sunscreen agents in cosmetics. Compared to the single‐variable approach, the advantage of the multivariate approach was that many factors could be investigated simultaneously to obtain the best separation condition. A fractional factorial design was used to identify the fewest significant factors in the central composite design (cCD). The cCD was adopted for evaluating the location of the minimum or maximum response in this study. The influences of the experimental variables on the response were investigated by applying a chromatographic exponential function. The optimized condition and the relationship between the experimental variables were acquired using the JMP software. The ANOVA analysis indicated that the Tris pH value, SDS concentration, and ethanol percentage influenced the separation quality and significantly contributed to the model. The optimized condition of the running buffer was 10 mM Tris buffer (pH 9.5) containing 60 mM SDS, 7 mM γ‐CD, and 20% v/v ethanol. The sample was prepared in 100 mM Tris buffer (pH 9.0) containing 7.5 mM SDS and 20% v/v ethanol. The SDS concentration in the sample matrix was slightly greater than the CMC value that makes the micelle be easily collapsed and the analytes be accumulated in the capillary. In addition, sunscreen agents in cosmetics after 1000‐fold dilution were successfully determined by AFMC‐MEKC.  相似文献   

5.
A general micellar electrokinetic chromatographic (MEKC) strategy for the impurity profiling of drugs was developed involving a sodium dodecyl sulfate (SDS) and a cetyltrimethylammonium bromide (CTAB) MEKC system. With this combination, in principle, each sample component passes the detector in at least one of the two MEKC systems provided that separation buffers of the same pH are used in both systems. In order to select the proper MEKC systems, the electroosmotic flow (EOF) and micelle migration time (t(mc)) were determined for separation buffers of several pH values, containing various amounts of surfactant and organic modifier. The selectivity of the MEKC systems was studied using a mixture of compounds with a wide range of physico-chemical properties. The final selection of two adequate MEKC systems for this approach was based on the requirements that the t(mc) (i.e., analysis time) of both systems was below 20 min and that the t(mc)/t(eof) ratio was above 3 or 2 for the SDS and CTAB system, respectively. Furthermore, the systems should provide high efficiency, exhibit differences in selectivity and use moderate concentrations of modifier and surfactant, so that, if needed, further optimization is possible. The selected MEKC systems contained 60 mM SDS or 10 mM CTAB, respectively, in a phosphate buffer (pH 7.5) with 10% acetonitrile. Some test compounds with extreme mobilities were used to demonstrate the suitability of the MEKC approach to detect each component of a sample. The potential of the proposed MEKC combination for impurity profiling was demonstrated by the analysis of fluvoxamine with several impurities at the 0.1% level.  相似文献   

6.
Téllez A  Fuguet E  Rosés M 《Electrophoresis》2007,28(20):3712-3721
A method to optimize the separation in micellar EKC (MEKC) of mixtures of acidic compounds as a function of two parameters, pH and concentration of sodium dodecyl sulfate, has been developed. The method considers the prediction of the retention time and the shape of the peaks. The retention time is predicted from the retention factor model and the peak shape by a polynomically modified Gaussian function that considers peak width, asymmetry factor, and height. An algorithm to calculate the global resolution of the separation at any experimental pH and [SDS] has been applied. This algorithm provides a 3-D resolution map to easily detect the areas in which resolution for the separation of the compounds is maximum. Initial experiments to fit the models have been performed with a set of ten phenolic compounds with different hydrophobicities and pK(a) values, and therefore, expected to behave in a different way with changes of pH and surfactant concentration. The experiments encompassed a pH range from 6.7 to 11.1, and a sodium dodecyl sulfate concentration range from 40 to 80 mM. Through the proposed methodology, chromatograms have been simulated at different pH and [SDS] very accurately. Furthermore, the resolution at any experimental point within the studied ranges have been also calculated, giving an optimum resolution value at pH 6.7 and [SDS] = 72 mM.  相似文献   

7.
Two different buffer systems for the separation of 12 aromatic hydrophobic sulfonates by micellar electrokinetic chromatography (MEKC) were developed. The following buffer systems were used: aqueous phosphate buffers containing either cetyltrimethylammonium bromide (CTAB) or sodium dodecyl sulfate (SDS). Eleven aromatic sulfonates were simultaneously separated in less than 35 min employing 20 mM phosphate buffer, pH 7.0 containing 50 mM SDS and 10% of acetonitrile.  相似文献   

8.
A suite of 12 widely used pharmaceuticals (ibuprofen, diclofenac, naproxen, bezafibrate, gemfibrozil, ofloxacin, norfloxacin, carbamazepine, primidone, sulphamethazine, sulphadimethoxine and sulphamethoxazole) commonly found in environmental waters were separated by highly sulphated CD-modified MEKC (CD-MEKC) with UV detection. An experimental design method, face-centred composite design, was employed to minimize run time without sacrificing resolution. Using an optimized BGE composed of 10 mM ammonium hydrogen phosphate, pH 11.5, 69 mM SDS, 6 mg/mL sulphated beta-CD and 8.5% v/v isopropanol, a separation voltage of 30 kV and a 48.5 cm x 50 microm id bare silica capillary at 30 degrees C allowed baseline separation of the 12 analytes in a total analysis time of 6.7 min. Instrument LODs in the low milligram per litre range were obtained, and when combined with offline preconcentration by SPE, LODs were between 4 and 30 microg/L.  相似文献   

9.
A selective procedure for qualitative and quantitative analysis of ten polyamines by micellar electrokinetic chromatography (MEKC) was developed. Benzoylated polyamines and acetylpolyamines in micellar phase of SDS (10 mM) were separated at 25 degrees C by 20 mM borate buffer pH 8.5, containing 8% ethanol, with an applied voltage of 25 kV (5 microA) and then detected at 198 nm. The experimental factors and operational parameters were optimized by performing analysis at different surfactant concentrations, pH, voltage and temperature with and without ethanol. The repeatibility of migration times and peak heights is a peculiarity of the method here described.  相似文献   

10.
We have employed a high‐sensitivity off‐line coupled with on‐line preconcentration method, cloud‐point extraction (CPE)/cation‐selective exhaustive injection (CSEI) and sweeping‐MEKC, for the analysis of malachite green. The variables that affect CPE were investigated. The optimal conditions were 250 g/L of Triton X‐100, 10% of Na2SO4 (w/v), heat‐assisted at 60°C for 20 min. We monitored the effects of several of the CSEI‐sweeping‐MEKC parameters – including the type of BGE, the concentrations of SDS, the injection length of the high‐conductivity buffer, and the injection time of the sample – to optimize the separation process. The optimal BGE was 50 mM citric acid (pH 2.2) containing 100 mM SDS. In addition, electrokinetic injection of the sample at 15 kV for 800 s provided both high separation efficiency and enhanced sweeping sensitivity. The sensitivity enhancement for malachite green was 1.9×104 relative to CZE; the coefficients of determination exceeded 0.9928. The LOD, based on an S/N of 3:1, of CSEI‐sweeping‐MEKC was 0.87 ng/mL; in contrast, when using off‐line CPE/CSEI‐sweeping‐MEKC the sensitivity increased to 69.6 pg/mL. This proposed method was successfully applied to determine trace amounts of malachite green in fish water samples.  相似文献   

11.
The migration characteristics of poly(4-vinylpyridine 1-oxide) (PVP-NO) in phosphate buffers of acidic pH (20 mM H3PO4 or NaH2PO4) have been studied using both free-solution capillary electrophoresis (FSCE) and MEKC. To inhibit adsorption, 250 mM o-phosphoethanolamine (2-aminoethyl dihydrogen phosphate) was used. In FSCE, PVP-NO showed a narrow peak and a broader band, both having anionic behavior. These peak and band were attributed to the free and aggregated or micellized PVP-NO forms, respectively. According to surface tension measurements, the CMC of SDS in the BGE was 1.8 and 0.48 mM in the absence and in the presence of 1000 microg/mL PVP-NO, respectively, and the association of the polymer with SDS was completed at 9.7 mM SDS. Using MEKC, a narrow peak and a broader band also appeared at SDS concentrations of ca. 1 mM, and their intensity increased with the SDS concentration. These peak and band were attributed to the formation of mixed micelles constituted by both free PVP-NO/SDS and aggregated PVP-NO/SDS, respectively. The determination of PVP-NO by FSCE in commercial additives for laundry was demonstrated.  相似文献   

12.
Different capillary electromigration techniques were employed to resolve geometrical isomers of sorbic acid, decadienoic acid, and ethyl sorbate. Since these substances differ in their polarity, shape, and size, various electromigration approaches were investigated to separate the four geometrical isomers of each compound. With capillary electrophoresis (CE) modified with a cyclodextrin (β‐CD) the four isomers of sorbic acid were separated using a buffer that consists of 60 mM tetraborate and 8 mg/mL β‐CD. The separation of decadienoic acid geometrical isomers was not possible, even at elevated tetraborate and cyclodextrin concentrations. The four isomers of decadienoic acid were successfully separated using micellar electrokinetic chromatography (MEKC) with a buffer consisting of 30 mM tetraborate and 100 mM SDS and microemulsion electrokinetic chromatography (MEEKC). Ethyl sorbate is the least polar of all the studied substances and its isomers could not be separated by MEKC or MEEKC. The resolution was improved and isomers were fully separated using capillary electrochromatography (CEC) with ODS stationary phase and a mobile phase consisting of 10 mM boric acid in 50% acetonitrile. Minor differences in the polarity and the shape of isomers and high resolving power of the applied techniques were sufficient for separation of very similar compounds. We have shown that versatile electromigration techniques can be applied for separation of geometrical isomers of dienoic acids and their esters.  相似文献   

13.
14.
Tzeng HF  Chen JY  Huang SW  Wang YJ  Yang CS 《Electrophoresis》2007,28(8):1221-1228
A simple and rapid MEKC method was developed for the simultaneous determination of myo-inositol, scyllo-inositol, and glucose. Prior to electrophoretic separation, the nonfluorescent inositols and glucose were derivatized by N-methylisatoic anhydride at 25 degrees C for 10 min so that they could be detected by a fluorescence detector during separation. The good separation with high efficiency by MEKC was achieved in 13 min with a glycine buffer containing SDS and PEG 4000. Several parameters affecting the separation were studied, including the pH of BGE, the concentrations of glycine, SDS, and PEG 4000, and the applied voltage. Using glycerol as an internal standard, the linear ranges of the method for myo-inositol, scyllo-inositol, and glucose were 0.03-10, 0.01-5, and 0.05-20 mM; the concentration LODs of myo-inositol, scyllo-inositol, and glucose were 0.020, 0.0078, and 0.026 mM, respectively. The method was applied to analyze extracellular myo-inositol and glucose in the microdialysates from rat brain cortex of ischemia animal model and intracellular myo-inositol and scyllo-inositol in the rat brain extract.  相似文献   

15.
In view of the fact that several studies have shown that diclofenac hydroxylation by cytochrome P450 2C9 deviated from Michaelis–Menten kinetics at low substrate concentrations, sweeping combined with MEKC was applied for the kinetic study of this pharmacologically important reaction. A 50 μm fused silica capillary (56 cm effective length) was used to carry out all separations. 70 mM SDS in 20 mM phosphate 20 mM tetraborate buffer, pH 8.6, was used as the BGE. Injection was accomplished by the application of 50 mbar (5 kPa) pressure to the sample vial for 52 s. Separation was performed at 22 kV (positive polarity), with a capillary temperature of 25°C and detection at 200 nm. The higher sensitivity of the sweeping‐MEKC combination compared with the simple MEKC method enabled this reaction to be fitted to a Hill kinetic model and confirmed the findings of other authors. A Michaelis constant of 2.91±0.10 μM, maximum reaction velocity of 9.16±0.16 nmol/min/nmol and Hill coefficient of 1.66±0.08 were determined. This value of Hill coefficient confirms the presence of a positive cooperativity at low diclofenac concentrations and supports the hypothesis of two substrates binding at or near the active site.  相似文献   

16.
Oligomeric procyanidins are potent antioxidant polyphenols of potential interest as disease-preventing agents. Their efficiency depends on the size and composition of their oligomeric structures. The mean degree of polymerization of these compounds is usually estimated by thiolysis with thiol-alpha-toluene followed by analysis using high-performance liquid chromatography (HPLC). We show the development of a mixed micellar electrokinetic chromatography (MEKC) method for the separation of the major components obtained after thiolysis with cysteamine (catechins and their cysteamine conjugates). MEKC studies using sodium dodecyl sulfate (SDS as pseudostationary phase led to long migration times, e.g., with 100 mM SDS, at pH 7, the solutes were separated in about 40 min), while the use of sodium cholate (SC) produced an elution window relatively short. Using a mixed micellar SC-SDS system (50 mM phosphate at pH 7 containing 40 mM SC and 10 mM SDS), it is possible to separate these compounds in less than 15 min. The proposed method is useful to separate the major components of the thiolysate in effluents from food processing (e.g., skins and seeds from grape and apple) considered as potential procyanidin sources.  相似文献   

17.
The analysis and use of fullerenes in capillary electrophoresis (CE) was investigated. Sodium dodecyl sulfate (SDS) was used to solubilize fullerenes C60, C70, and a mixture of C60 and C70 in water. The behavior of the solutions of the C60- and C70-SDS complexes was examined by CE with on-line UV-Vis diode array detection. This study included the use of a C60-SDS complex as a new method of micellar electrokinetic chromatography (MEKC) for the separation of polycyclic aromatic hydrocarbons (PAHs) using CE with uniwavelength detection. Since SDS micelles act as a pseudostationary phase in which the PAH compounds partition with their hydrophobic interior, the addition of C60 within the micelles enhanced separation of the PAHs. The preliminary results using C60-MEKC with SDS were compared to those obtained with MEKC with SDS. The capillary electrophoretic separations were performed in 10 mM borate-phosphate buffer with 100 mM SDS at pH 9.5.  相似文献   

18.
Micellar electrokinetic chromatography (MEKC) was successfully and conveniently applied to the chiral separation with the addition of cyclodextrins (CDs) as chiral selector to the running buffer. Chiral separation depended on the type of CD; in particular, beta-CD was effective for the chiral separation of racemorphan. We investigated the optimal conditions of type and concentration of CD as chiral selector for the routine enantiomeric separation of racemorphan with good reproducibility. The effects of other parameters such as buffer pH and detection wavelength were also investigated to obtain the optimum conditions for the enantiomeric separation of racemorphan. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was used for confirmation of racemorphan. The optimal conditions for enantiomeric separation of the racemorphan were as follows: 50 mM borate buffer at pH 9.4 with 50 mM SDS, 10 mM beta-CD and 20% 1-propanol, 57 cm x 50 microns fused-silica capillary column, and UV detection at 192 nm. Based on the developed method, racemorphan in human urine was also separated and determined using solid-phase extraction and MEKC.  相似文献   

19.
Quantitative high-performance liquid chromatographic (HPLC) and micellar electrokinetic chromatographic (MEKC) methods have been developed for the determination of four structurally related potential manufacturing impurities, including morphine, of the opiate derivative pholcodine. Pholcodine and the four impurities were separated by MEKC in less than 14 min using a 70 cm x 75 microm I.D. uncoated fused-silica capillary (25 kV at 30 degrees C) and a running buffer consisting of 10% acetonitrile (v/v) in 20 mM borate-phosphate buffer pH 8.0 containing 40 mM sodium dodecyl sulphate (SDS). The MEKC method was compared to a HPLC method using a 5 microm Luna phenyl-hexyl column (150 x 4.6 mm I.D.) eluted with a mobile phase consisting of a mixture of 10% (v/v) acetonitrile, 7% (v/v) tetrahydrofuran in 20 mM phosphate buffer pH 8.0. Both methods were fully validated and a comparison was made regarding selectivity, linearity, precision, robustness and limits of detection and quantitation. The presence of the impurities in different samples of pholcodine drug substance was investigated using both methods.  相似文献   

20.
We report the separation of polycyclic aromatic hydrocarbons (PAHs) using 0.1% poly(ethylene oxide) (PEO) in micellar electrokinetic chromatography (MEKC). In the presence of PEO, adsorption of PAHs on the capillary wall was reduced, leading to better resolution and reproducibility. Effects of tetrapentylammonium iodide (TPAI), dextran sulfate (DS), methanol, and sodium lauryl sulfate (SDS) on the separation of PAHs were elucidated. In terms of resolution and speed, DS, compared to TPAI, is a better additive for separation of PAHs. When using 0.1% PEO solution containing 45% methanol, 50 mM SDS, and 0.02% DS, separation of 10 PAHs containing 2 to 5 benzene rings was accomplished in less than 12 min at 15 kV in a commercial CE system. The method has also been tested for separating seven PAHs with high quantum yields when excited at 325 nm using a He-Cd laser. Unfortunately, separation of the seven PAHs was not achieved and sensitivity diminished under the same conditions. To optimize sensitivity, resolution and speed, a stepwise technique in MEKC has been proposed. The seven PAHs were resolved in 35 min at 15 kV when separation was performed in 0.1% PEO solution containing 35 mM SDS, 40% methanol and 0.02% DS for 2 min, and subsequently in 0.1% PEO solution containing 20 mM SDS, 50% methanol, and 0.02% DS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号