首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A sensitive, efficient, high throughput, direct injection bioanalytical method based on a single column and high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS/MS) was developed for pharmacokinetic analysis of early drug discovery compounds in plasma samples. After mixing with a working solution containing an internal standard each plasma sample was directly injected into a polymer-coated mixed-function column for sample cleanup, enrichment and chromatographic separation. The stationary phase incorporates hydrophilic polyoxyethylene groups and hydrophobic groups to the polymer-coated silica. This allows proteins and macromolecules to pass through the column due to restricted access to the surface of the packing while retaining the drug molecules on the bonded hydrophobic phase. The analytes retained in the column with a largely aqueous liquid mobile phase were then chemically separated by switching to a strong organic mobile phase. The column effluent was diverted from waste to the mass spectrometer for analyte detection. Within 200 plasma sample injections the response ratio (analyte vs. internal standard, %CV = 4.6) and the retention times for analyte and internal standard were found consistent and no column deterioration was observed. The recoveries of test compound in various plasma samples were greater than 90%. The total analysis time was 相似文献   

2.
High-performance liquid chromatography/mass spectrometry (HPLC/MS) is increasingly perceived to be an essential tool in drug discovery at many key steps, like drug screening, lead identification, ADME profiling, and drug metabolism and pharmacology studies. High-throughput screenings in the early phase for metabolic stability, protein binding, permeability (ADME) and bioavailability are widely used to weed out compounds that do not exhibit the necessary characteristics. For such high-throughput LC/MS studies, a generic LC/MS method that can be used for a variety of compounds is desired. In this study, we used a small set of compounds with a wide range of properties to guide method development, and achieved a sample throughput of 1.7 min/sample. Here, we present a generic fast method that achieves good peak separation and peak shape on conventional HPLC systems using a column-switching mechanism for on-line solid-phase extraction (SPE)-HPLC/MS analysis. The method has a linear response range from 1 to 500 nM for the tested compounds. When a larger set of 658 randomly picked small molecules were analyzed using this method, 612 were observed with good signal intensity and HPLC peak shapes. This generic fast SPE-LC/MS method has been used to screen more than 1.5 million compounds repetitively against over 200 protein targets for hit confirmation and semi-quantitation of binding constants from biological assays. Over 7000 different compounds for a variety of protein-binding assays have been studied using this method for quantitative analysis as well.  相似文献   

3.
The use of open-access mass spectrometry to monitor synthetic chemistry reactions, and also the integrity and purity of new chemical entities, has been a part of the medicinal chemist's tool-box for more than 5 years. Originally in our group at Wyeth Research there were two open-access methods available to the chemists, flow injection analysis (FIA) and liquid chromatography/mass spectrometry (LC/MS). The FIA method was approximately 3 min long, while the LC/MS method was approximately 20 min long (including an 8 min gradient). Within the first 2 years, the total number of open-access analyses increased by approximately 125%. It is interesting, however, that the number of LC/MS analyses increased by more than 285%. This is attributed to the fact that the chemists began using the LC/MS data to monitor reactions and also to check final product integrity and purity. In addition, the number of chemists performing parallel synthesis reactions has increased; thus, individual chemists can produce sample sets of up to 100 vials. This paper describes the implementation of new methodology, which accommodates the need for much faster run times and also the ability to acquire alternating positive and negative ion spectra within the same run. In addition, the instrument has been configured to e-mail the resulting processed data report to the submitting chemist. Several methods have been developed, including structure elucidation using in-source collision-induced dissociation (CID) and night-time analysis. The LC/MS methods for this system are described herein and are applicable to both industrial and academic synthetic chemistry optimization efforts.  相似文献   

4.
A higher-throughput bioanalytical method based on fast-gradient (1 min run time) high-performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS/MS) was developed for screen-type analyses of plasma samples from early drug discovery studies in support of exploratory pharmacodynamic studies. The HPLC system equipped with minibore column was interfaced with either atmospheric pressure chemical ionization (APCI) or electrospray (ESI) ionization techniques. The matrix ion suppression effect of both quantitative HPLC/MS/MS analyses was compared using the post-column infusion system. The use of the described methods provided advantages such as a shorter chromatographic region of ion suppression, less solvent consumption and shorter run times in comparison with standard analytical column HPLC/MS/MS methods. The analytical results obtained by both HPLC/MS/MS methods were in good agreement (within 15% of error) and displayed a good correlation with the pharmacodynamic outcome.  相似文献   

5.
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections.  相似文献   

6.
Reversed-phase liquid chromatography (LC) and LC/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of etoricoxib in pharmaceutical dosage forms. The LC method was performed by reversed-phase chromatography on a Synergi fusion C18 column (150 x 4.6 mm id) maintained at ambient temperature. The mobile phase consisted of 0.01 M phosphoric acid, pH 3.0-acetonitrile (62 + 38, v/v) at a flow rate of 1.0 mL/min, and photodiode array detection at 234 nm was used. The chromatographic separation was obtained within 7.0 min, and calibration curves were linear in the concentration range of 0.02-150 microg/mL. The LC/MS/MS method was performed on a Luna C18 column (50 x 3.0 mm id). The mobile phase consisted of acetonitrile-water (95 + 5)-0.1% acetic acid (90 + 10, v/v). Detection was performed by positive electrospray ionization in the multiple reaction monitoring mode, monitoring the transitions 359.3 > 280.0 and 332.0 > 95.0 for etoricoxib and piroxicam (internal standard), respectively. The chromatographic separation was obtained within 2.0 min, and calibration curves were linear in the concentration range of 1-5000 ng/mL. Validation parameters, such as specificity, linearity, precision, accuracy, and robustness, were evaluated, which gave results within the acceptable range for both methods. Moreover, the proposed methods were successfully applied for routine quality control analysis of pharmaceutical products and showed significant correlation (r = 0.9999) of the results.  相似文献   

7.
Erythrocyte alkylresorcinols (5‐alkyl‐1,3‐dihydroxybenzenes) are potential biomarkers of wholegrain wheat and rye intake. However, their high‐throughput quantitative analysis by gas chromatography/mass spectrometry (GC/MS) is hindered by the time‐consuming sample preparation and, more importantly, by interfering compounds that still remain after sample cleanup. In the present work we describe a gas chromatography/tandem mass spectrometry (GC/MS/MS) method for the rapid and reliable quantification of alkylresorcinols in erythrocyte samples. The performance of the GC/MS/MS method is compared with that of GC/MS. The main characteristics of the method are: lower limits of detection: 2–10 µg/L standard solution; lower limits of quantification: 6–30 µg/L standard solution; linearity coefficients: 0.9611–0.9888; linear ranges: 2–20 µg/L in erythrocytes; and intra‐day precisions (n = 6): 4–13% at endogenous analyte levels in non‐spiked erythrocytes. Tandem mass spectrometry showed greatly improved selectivity over single‐stage mass spectrometry in the case of erythrocyte samples, eliminating all interferences detectable in single‐stage MS and enabling simple peak integration for quantification. Moreover, increased selectivity resulted in GC separation speeded up by a factor of two, allowing the duplicate analysis of over 40 samples per day. This GC/MS/MS method is suggested as an improved alternative to GC/MS for the quantification of alkylresorcinols in erythrocytes for assessing wholegrain wheat and rye intake. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
For higher throughput screening, where the number of new chemical entities (NCEs) to test is rapidly increasing, fast sample turnaround time is essential. In order to increase efficiency a generic high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method, with a cycle time of 85 s (42 injections/h), was created. This was accomplished through the use of a 1-min ballistic gradient and the optimization of the autosampler. The gradient was optimized by varying the organic mobile phase concentration and examining its ballistic characteristics with respect to matrix ion suppression and compound retention time. The autosampler time could be reduced by optimizing several parameters and by determining the source of most of the carryover in order to reduce the number of syringe and injector washes. Finally, the reliability of the new generic method is demonstrated by comparison of sample data with a standard 2-min linear gradient method that showed that the data sets were well correlated. For plasma AUC (ng.h/mL) of 28 NCEs, the regression line had a slope of 0.92 and the R2 was 0.929. The described method was found to be useful for both rat plasma and tissue samples.  相似文献   

9.
A liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for measurement of aflatoxins B1, B2, G1, and G2 in maize is described. Aflatoxins (AFs) were extracted from 1 g samples by using tri-portions of acetonitrile/water (80:20, v/v) (10 + 7 + 7 mL), and 2/5 of the extract diluted to 500 mL by water was cleaned up with a 100 mg Carbograph-4 cartridge. After the addition of the internal standard AFM1, the final extract was analyzed by LC/ESI-MS/MS in positive ion mode using multiple reaction monitoring with a triple-quadrupole instrument. A C(18) column thermostatted at 45 degrees C with a mobile phase gradient of acetonitrile/water with 2 mmol/L ammonium formate was used. Although the matrix suppression effect was negligible, quantitation was achieved by an external calibration procedure using matrix-matched standard solutions to improve accuracy. Sample recoveries at four spiking levels ranged from 81 to 101% (relative standard deviation (RSD) 相似文献   

10.
Micro-size exclusion chromatography coupled with capillary liquid chromatography (capLC) and mass spectrometry (MS) provides a rapid and simple approach to the preliminary screening of active ligands toward a specific target macromolecule. In this study, the effectiveness of this technique is demonstrated by a number of small molecule ligands with known binding affinities towards the protein target. All ligands were incubated together with a target protein under native conditions. Separation was then achieved by microcentrifugation where the high molecular weight (MW) compounds were selectively passed through the size-exclusion material. The retained low MW compounds were then recovered and analyzed by capLC/MS. The absence of the ligand indicated strong affinity towards the target, while ligand detection indicated inactivity. This assay demonstrated the drugs that were acting as strong inhibitors of Co-PDF from those showing to be comparatively inactive. The relative binding rank order of the drugs towards Co-PDF was also determined. The results were validated by a corresponding set of control experiments in which the target molecules were excluded from the process. In principle, high-throughput micro-size exclusion chromatography, coupled with capLC/MS, offers a powerful technique as a preliminary screen in determining both the strong binding affinity and the relative affinity rank ordering of ligands towards a specific target macromolecule, and is complementary with other analytical drug screening techniques.  相似文献   

11.
12.
13.
High-throughput chiral liquid chromatography/tandem mass spectrometry   总被引:3,自引:0,他引:3  
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments.  相似文献   

14.
One of the current environmental issues concerns the presence and fate of pharmaceuticals in water bodies as these compounds may represent a potential environmental problem. The characterization of pharmaceutical contamination requires powerful analytical method able to quantify these pollutants at very low concentration (few ng L−1).  相似文献   

15.
High-performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICPMS) has been studied as a means for the detection of carbon to provide a 'universal' method for detecting organic compounds in chromatographic eluents. Carbon is particularly difficult to ionise and the amount of carbon present in normal chromatographic systems leads to high backgrounds, making detection a challenge. Novel separation approaches were therefore employed, using either entirely aqueous eluents (at temperatures of 60 and 160 degrees C, dependent on the column used) to eliminate the organic modifier completely, or isotopically enriched solvents. For the aqueous eluents, detection limits for sulphanilamide were found to be 2.26 microg, corresponding to 1.13 micromol (0.47 micromol of carbon), injected on a conventional 4.6 mm i.d. column. The use of a narrow bore column with highly isotopically enriched 12C-methanol (99.95 atom%) as organic modifier for the mobile phase enabled the detection of 86 micromol for 13C-triple-labelled caffeine and 79 micromol for 13C-double-labelled phenacetin. The sensitive detection of 12C-compounds with 13C-enriched methanol as organic modifier proved impractical due to a lower level of isotopic enrichment (99 atom%) of this solvent, with the residual 12C-methanol resulting in significant interference.  相似文献   

16.
Ultra-performance liquid chromatography (UPLC) was investigated as an alternative to high-performance liquid chromatography (HPLC) for analyzing pharmaceutical drug candidates. We previously developed a 96-well-based high-speed solubility assay system (HSSOL) using HPLC/UV and a LogD assay system (HSLogD) using HPLC/MS [Y. Dohta, T. Yamashita, S. Horiike, T. Nakamura, T. Fukami, Anal. Chem. 79 (2007) 8312]. We have introduced the UPLC/MS system into this previously developed HSSOL system to increase throughput. Results obtained by the UPLC/MS and HPLC/UV systems showed good agreement, validating the usefulness of the UPLC/MS system. A high-speed solubility assay system was developed employing the UPLC/MS system, thereby tripling the throughput.  相似文献   

17.
Artemisinin is a widely used antimalarial drug. To evaluate the pharmacokinetics of artemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC/MS/MS) method was developed and validated for the determination of artemisinin in rat plasma. For detection, a Sciex API 4000 LC/MS/MS instrument with an electrospray ionization (ESI) TurboIonSpray inlet in the positive ion multiple reaction monitoring (MRM) mode was used to monitor precursor ([M+NH4]+) --> product ions of m/z 300.4 --> 209.4 for artemisinin and m/z 316.4 --> 163.4 for artemether, the internal standard (IS). The plasma samples were pretreated by a simple liquid-liquid extraction with ether. The standard curve was linear (r > 0.99) over the artemisinin concentration range of 1.0-200.0 ng/mL in plasma. The method had a lower limit of quantification of 1.0 ng/mL for artemisinin in 100 microL of plasma, which offered a satisfactory sensitivity for the determination of artemisinin. The intra- and inter-day precisions were measured to be within +/-5.3% and accuracy between -2.6% and 1.2% for all quality control samples, lower limit of quantification and upper limit of quantification samples. The extraction recoveries of artemisinin and the IS were 95.4 +/- 4.5% and 92.8 +/- 3.9%, respectively. This present method was successfully applied to the characterization of the pharmacokinetic profile of artemisinin in rats after oral administration.  相似文献   

18.
The demand for high sensitivity bioanalytical methods has dramatically increased in the drug discovery stage; in addition, there has been a growing trend of reducing the sample volume that is required for these assays. A sensitive high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) procedure has been developed and tested to meet these needs. The assay requires only a low plasma sample volume (10 microL) and employs a protein precipitation procedure using a 1:6 plasma/acetonitrile ratio. The supernatant is injected directly into the LC/MS/MS system using the selected reaction monitoring (SRM) procedure for detection. A generic HPLC gradient based on a methanol/water mobile phase with a flow rate set to 0.8 mL/min was used. The test method showed very good linearity between 0.1-1000 ng/mL (R2 = 0.9737), precision (%RSD = 6-9), accuracy (%RE = -2) and reproducibility (%RSD = 11). A drug discovery IV/PO study was assayed using both the new low volume method and our standard volume (50 microL) method. The correlation of the two sets of data from the two methods was excellent (R2 = 0.9287). This new assay procedure has been successfully used in our laboratory for over 100 different rat or mouse discovery PK studies.  相似文献   

19.
A method is described for the evaluation of drug concentrations in plasma and brain from treated rats. The analyte is recovered from plasma or brain homogenate by liquid-liquid extraction and subsequently analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). A simple experimental protocol renders the procedure valuable for obtaining information rapidly on brain penetration and plasma exposure of specific classes of compounds. This methodology has been applied to evaluate brain penetration with 30 different compounds from the same discovery program. In an attempt to increase throughput in our screening efforts, mixture dosing was evaluated. Results from single compound administration were compared with results following administration of a mixture of four compounds. Preliminary results, with specific classes of compounds, show no major differences (ranking order) in brain or plasma concentrations between mixture dosing and single compound administration, suggesting that mixture dosing could be applicable to brain penetration studies in the drug discovery phase.  相似文献   

20.
A simple and sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC‐ESI‐MS/MS) method was developed and validated for determination of two highly lipophilic anticancer drug candidates, LG1980 and GH501, in rat plasma and tissues (liver, kidney and femur bones). LG1980 and GH501 were extracted from rat plasma and tissue homogenates using liquid–liquid extraction. The method provided a linear range of 1.0–200.0 ng/mL for GH501 in plasma and LG1980 in plasma and liver. For both analytes in other tissue homogenates the linear range was 2.0–400.0 ng/mL. The method was validated with precision within 15% relative standard deviation, accuracy within 15% relative error and a consistent recovery. This method has been successfully applied in two preclinical studies for LG1980 and GH501 to determine their concentrations in rat plasma, liver, kidney and bone over 24 h after intravenous injection of compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号