首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Manganese is extracted on-line from solid seafood samples by a simple continuous ultrasound-assisted extraction system (CUES). This system is connected to an on-line manifold, which permits the flow-injection flame atomic absorption spectrometric determination of manganese. Optimisation of the continuous leaching procedure is performed by an experimental design. The proposed method allows the determination of manganese with a relative standard deviation of 0.9% for a sample containing 23.4 μg g−1 manganese (dry mass). The detection limit is 0.4 μg g−1 (dry mass) for 30 mg of sample and the sample throughput is ca. 60 samples per hour. Accurate results are obtained by measuring TORT-1 certified reference material. The procedure is finally applied to mussel, tuna, sardine and clams samples.  相似文献   

2.
Iron was extracted on-line from solid meat samples by a simple and rapid continuous ultrasound-assisted extraction system (CUES). The CUES is connected to a flow injection manifold, which allows the on-line flame atomic absorption spectrometric determination of iron. A Plakett–Burman design was used for the optimisation of the CUES. The method achieved a total sampling frequency of 11 samples per hour with a relative standard deviation for the complete procedure of 0.4%. The detection limit was 0.6 g g–1 (dry mass) for a sample amount of 30 mg. Accurate results were obtained by measuring the certified reference materials BCR-186 (pig kidney) and BCR-184 (bovine muscle). The analytical procedure was applied to different real meat samples with satisfactory results.  相似文献   

3.
A new sensitive and low-cost method that combines continuous acid extraction, online preconcentration, and flame atomic absorption spectrometry for cadmium determination at microg levels in solid and semisolid milk products is described. A continuous ultrasound-assisted extraction system is used to carry out the dynamic acid extraction step. The acid extract is preconcentrated online on a minicolumn packed with a chelating resin (Chelite P, with aminomethylphosphoric acid groups), and the retained cadmium is eluted with hydrochloric acid and continuously monitored by flame atomic absorption spectrometry. An experimental design (Plackett-Burman 2-6*3/16) is used to optimize the continuous extraction and the preconcentration step. The method allowed a total sampling frequency of 28 samples/h. A good precision of the whole procedure (3.0% relative standard deviation) for a cheese sample containing 0.103 +/- 0.004 microg/g Cd (dry mass), a high enrichment factor (20.5), and detection and quantification limits of 0.014 and 0.067 microg/g, respectively, for a 60 mg of sample were obtained with this methodology. The method was successfully applied to the determination of trace amounts of cadmium in solid and semisolid milk products, such as cheese and yogurt samples.  相似文献   

4.
A manifold has been developed for on-line microwave oven digestion and flame atomic absorption spectrometric (FAAS) determination of metallic elements in solid samples. The use of a closed flow system permits sample treatment before analysis by FAAS, the direct injection of slurries avoids a filtration step and the interconnection of two conventional rotary injection valves allows the rapid introduction of samples and standards. The determination of lead in sewage sludge was employed as a test system for the proposed on-line sample digestion manifold. The procedure has a limit of detection of 0.2 μg Pb g?1.  相似文献   

5.
A continuous ultrasound-assisted extraction system connected to a flow injection manifold has been used for the on-line determination of zinc in meat samples by flame atomic absorption spectrometry. An experimental design was used for the optimisation of the continuous manifold. This flow injection methodology allowed a sampling frequency of ca. 80 samples per hour with a relative standard deviation for the whole procedure of 0.3% (for a sample containing 163.6 μg g−1 Zn). The detection limit was 0.6 μg g−1 for a sample amount of 5 mg. Accurate results were obtained by measuring certified reference materials (BCR-186 (pig kidney) and BCR-184 (bovine muscle)). The analytical procedure was applied to different real meat samples with satisfactory results.  相似文献   

6.
A rapid and sensitive method has been proposed for the determination of chromium and cobalt in seafood samples by flame atomic absorption spectrometry combined with a dynamic ultrasound-assisted acid extraction and an on-line minicolumn preconcentration. The use of diluted nitric acid as extractant in a continuous mode at a flow rate of 3.5 mL min(-1) and room temperature was sufficient for quantitative extraction of these trace metals from seafoods. A minicolumn containing a chelating resin was an excellent device for the quantitative preconcentration of chromium and cobalt prior to their detection. A flow-injection manifold was used as interface for coupling all analytical steps, which allowed the automation of the whole analytical process. A Plackett-Burman experimental design was used as a multivariate strategy for the optimization of both sample preparation and preconcentration steps. The method was successfully applied to the determination of chromium and cobalt in seafood samples.  相似文献   

7.
A simple and new flow-injection manifold (CUDS) for the continuous ultrasound assisted dissolution of a soluble solid sample coupled to a flow-injection flame atomic absorption spectrometric manifold for the continuous iron determination is described. An experimental design was used for the evaluation of factors involving the CUDS. The method was applied to a certified reference material (CRM-151, skim milk powder) for quality assurance/validation and to real samples (milk powder and infant formulas). The total sampling frequency achieved was 80 samples per hour with a relative standard deviation for the complete procedure of 1.1%. The detection limit was 0.60 μg g−1 for a sample amount of 30 mg. The results demonstrated that the CUDS is an innovative and efficient tool as compared to the manual-traditional sample preparation methods, but with drastic increase of both sample throughput and precision.  相似文献   

8.
García IL  Cortéz JA  Córdoba MH 《Talanta》1993,40(11):1677-1685
A study on the use of slurries in flame atomic absorption spectrometry is reported. Samples with a very high silica content are ground and then slurried in a solution containing 2% hydrochloric and 3% v/v hydrofluoric acids. The suspensions are prepared in the 0.01-1% m/v range and introduced into the flame by means of a simple flow injection manifold. Relative standard deviations for the measurements of iron, calcium and magnesium in diatomaceous earth samples are in the 1.5-2.8, 2.2-5.3 and 2.8-5.0% ranges, respectively. To avoid the use of suspensions prepared with a very low percentage of solid sample and to improve the reproducibility, an on-line dilution manifold is tried. The use of an easy-to-construct variable volume dilution chamber allows the on-line dilution of the slurries, thus permitting the determination of calcium and magnesium over a wide range of concentrations. Calibration is performed using aqueous standards. The experimental conditions, optimized for the determination of iron, calcium and magnesium in diatomaceous earth samples, can also be applied to other silica-based materials, as is shown by the analysis of several standard reference materials.  相似文献   

9.
A direct solid sampling flame atomic absorption spectrometric procedure for trace determination of cadmium in biological samples has been developed. Test samples (0.05–2.00 mg) were ground and weighed into small polyethylene vials, which were connected to the device for solid sample introduction into a conventional air/acetylene flame. Test samples were carried as a dry aerosol to a quartz cell, placed between the burner and the optical path, which had a perpendicular entrance and a slit in the upper part. The atomic vapor generated in the flame produced a transient signal that was totally integrated within 1 s. The effect of operating conditions and the extent of grinding on the analytical signal were evaluated. Background signals were always low and a characteristic mass of 0.29 ng Cd was obtained. Calibration was performed using different masses of solid certified reference materials. Results obtained for certified and in-house reference materials were typically within the 95% confidence interval of the certified and/or reference value, and the precision, expressed as relative standard deviation, was between 3.8 and 6.7%. The proposed system is simple and it might be adapted to conventional atomic absorption spectrometers allowing the determination of Cd in more than 80 test samples per hour, excluding weighing.  相似文献   

10.
    
The on-line double membrane dialyser described previously was coupled in series to a single dialyser in the manifold of a flow injection system to include the determination of samples with a high chloride content simultaneously with calcium in industrial effluents from a single sample injection. 50 l of industrial effluent samples are injected into a carrier stream and are simultaneously dialysed in the double on-line dialyser for chloride and calcium. The dialysed chloride sample zones are further directed to a second dialyser that is incorporated in series with the first dialyser. This enables laboratories to determine samples with a very high chloride content up to 60 g/l simultaneously with calcium by using an automated tandem on-line dialysis technique. The fast and reliable fully automated two-component flow injection procedure operated at a sampling frequency of 90 samples per hour and the results obtained for chloride and calcium in industrial effluents compared well with those obtained by standard methods.  相似文献   

11.
A flame atomic absorption spectrometric procedure for the rapid determination of manganese, lead, zinc, calcium, magnesium, iron, sodium and potassium in cements is described. For minor components, slurries are prepared in the 0.05–0.25% m/v range by direct suspension of the samples in a medium containing 2% v/v nitric acid, 2% hydrofluoric acid and 30% v/v glycerol. 50–200 l aliquots are injected in a simple flow injection manifold using water as the carrier. When determining major components, the FI manifold includes an easy-to-construct variable volume chamber allowing the on-line dilution of the suspensions. The degree of dilution can be easily modified to obtain signals within the linear response range of the instrument. Aqueous standards are used for calibration. The data obtained for six cements agree with those obtained by conventional procedures based on the compl M v£e w ete dissolution of the samples.  相似文献   

12.
A procedure is described for the rapid determination of calcium, magnesium and zinc in honey with no previous mineralization stage. The samples are dissolved in a solution containing dilute hydrochloric acid and a lanthanum salt, and then directly introduced into the flame atomic absorption spectrometer by means of a simple continuous-flow manifold. The computer-controlled system performs an automatic on-line dilution of the solutions, in this way decreasing matrix effects due to the organic matter content and allowing analytical signals within the linear response range to be obtained. Calibration is carried out against aqueous standards. Reproducibilities for calcium and magnesium measurements in the honey samples are close to +/-3%. The detection limit for zinc is 0.2 mug g(-1), the reproducibility obtained for a honey sample containing 1.7 mug g(-1) zinc being +/-5.2%. The results agree with those obtained by means of a lengthy mineralization-based procedure, the main advantages of the non-conventional methodology reported being automation, saving of time and a decrease in the contamination risk.  相似文献   

13.
A direct procedure has been developed for the flame atomic determination of potassium and magnesium in cement samples. A 50-mg sample is dispersed in 25 ml of 0.13M nitric acid; 100 mul of this slurry is injected in a double channel FIA manifold simultaneously with 100 mul of a 10% (w/v) lanthanum solution. This procedure allows the rapid extraction of potassium and magnesium by leaching of the sample; nitric acid is not necessary if only potassium must be determined and the sample can be diluted with only distilled water. Aqueous standards are used. The manifold employed includes a well-stirred mixing chamber, which provides an adequate on-line dilution of the sample, in order to obtain emission or absorbance measurements in the dynamic range of the elements to be determined. The results obtained in the analysis of real samples agree with those found by flame atomic spectrometry after a previous alkaline fusion with lithium carbonate, and exhibit better precision. The limit of detection of the procedure is 0.007% for K(2)O and 0.01% for MgO and the precision of the entire procedure corresponds to a relative standard deviation of 1%.  相似文献   

14.
Summary A fast and reliable fully automated three-component flow injection procedure for the simultaneous determination of free calcium, total calcium and total chloride in milk is described where the three components from a single sample injection (30 l milk samples) are determined at a sampling rate of 60 samples per hour. The samples are directed to three different channels by using two dialysers in series. Interferences in the determination of free calcium are eliminated by using a dialyser (first in the series) which also separates the total and free calcium. Free calcium is determined by UV/VIS spectrophotometry at 580 nm and total calcium by atomic absorption spectrometry (AAS) at 422.7 nm. Interferences from phosphates in milk in the determination of total calcium by AAS are overcome by using a nitrous oxide-acetylene flame with the necessary suppression with potassium ions. A second dialyser in series is used to eliminate interferences, especially the interference of casein, before the dialysed chloride is measured with a coated tubular chloride-selective electrode. The results obtained for the free calcium, total calcium and total chloride in milk at a sampling rate of 60 samples per hour compared well with data obtained by standard methods. With 30 l samples the relative standard deviation for milk samples having different concentrations of free calcium (110–170 mg/l free calcium), total calcium (1000–1500 mg/l total calcium) and total chloride (1000–1800 mg/l total chloride) were better than 0.37, 1.01 and 0.25, respectively.  相似文献   

15.
In this work a new device for the direct introduction of solid samples into flame atomizers is proposed. The determination of copper in bovine liver reference material by flame atomic absorption spectrometry (FAAS) using a conventional air–acetylene flame was chosen as an example. Between 0.05 and 0.50 mg of the test sample was weighed directly into a small polyethylene vial connected to a glass chamber. A flow of air carries the test sample as a dry aerosol to a T-shaped quartz cell positioned above the burner in the optical path. The atomic vapor generated produces a transient signal of less than 3-s duration; integrated absorbance is used for signal evaluation. Optimized conditions for air flow rate, flame stoichiometry, etc., were evaluated. There was no statistical difference between the results from the proposed system, compared with those obtained by prior sample digestion and determination by conventional FAAS. No excessive grinding of the samples was required and samples with particle size less than 80 μm were used throughout. Background signals were always low and a characteristic mass of 1.5 ng was found for Cu. The proposed system allows the determination of 60 test samples in 1 h and it can be easily adapted to conventional atomic absorption spectrometers.  相似文献   

16.
Summary A new procedure is proposed for the determination of gold by flame atomic absorption in jewelry samples. The method is based on the acid digestion of 10 mg of sample in a microwave oven and on the on-line dilution, using a three-way valve. The dynamic range of the technique is extended to 100 mg/l gold solutions and using a weighted bracketing method for the treatment of the results, accuracy errors lower than 2% can be found in the analysis of real samples as compared with those obtained by fire assay. The method is very fast and implies only little damage to the jewelry samples.  相似文献   

17.
The advantages of using membrane micropumps to introduce sample or standard solutions in flame atomic absorption spectrometry are discussed, using two entirely computer-controlled manifolds which allow a wide range of dispersion coefficients to be obtained. Coupling micropumps to the manifold facilitates calibration graphs to be obtained using a single standard solution. Other advantages include a handy on-line dilution stage for excessively concentrated samples as well as the possibility of obtaining pulsed absorbance-time profiles that once submitted to the Fourier transformation, provide amplitude-frequency plots representing an innovative, not yet fully exploited vision of atomic absorption analytical data.  相似文献   

18.
In this study, a new device was applied for direct solid sampling flame atomic absorption spectrometry. It was used for trace determination of cadmium in biological samples (bovine and chicken liver). Test samples (0.5 to 7 mg) were weighed into small paper capsules, which were introduced into a quartz cell heated by an air-acetylene flame. Operational conditions for the proposed system were evaluated. There was no significant difference between the results obtained with the proposed system and those obtained after digestion and determination by conventional graphite furnace atomic absorption spectrometry. Good agreement was also obtained with the certified values of two reference materials. Background signals were always low. The characteristic mass was 0.34 ng and relative standard deviation was less than 8%. The limit of detection for the proposed procedure was 1.6 ng or 0.23 μg g 1 if a sample mass of 7 mg was used. Excluding the steps for sample preparation (drying, milling and weighing), the proposed system allows the determination of 40 test samples per hour and it can be easily adapted to conventional flame atomic absorption spectrometers.  相似文献   

19.
An alternative device for the direct solid analysis (DSA) for copper determination by flame atomic absorption spectrometry (FAAS) is proposed. Copper was directly determined in commercial medicinal plants used as dietary supplements. The determination of copper in solid samples by DSA–FAAS was made by using a conventional air–acetylene flame. Between 0.05 and 1.5 mg of each test, sample was weighed directly into a small polyethylene vial connected to the device used for solid introduction into the flame. Test samples were introduced into the flame as a dry aerosol using a T-quartz cell set between the burner and the optical path. The T-quartz cell has a slit in the superior part by which the solid aerosol passes to the flame. A transient signal, evaluated as integrated absorbance, is produced and it is totally integrated in 2 s. Background signals always presented absorbance values less than 0.1. It was found a characteristic mass of 0.8 ng Cu and absolute limit of detection of 1.2 ng (3 s), or 1.2 μg g−1 if a sample mass of 1 mg was used. Optimized conditions for air flow rate, flame stoichiometry, and so on were established as well. No excessive grinding of the samples was needed and samples with particle of size less than 80 μm were used throughout. No statistical difference between the results from the proposed system and those obtained by sample digestion and determination by conventional FAAS was observed. With the proposed procedure, more than 50 test samples can be analyzed in 1 h and it can be easily adapted to conventional spectrometers for FAAS.  相似文献   

20.
微量进样火焰原子吸收光谱法对牛奶中钙的直接测定   总被引:1,自引:0,他引:1  
采用微量进样火焰原子吸收光谱法(FAAS)直接测定牛奶中的钙,无需样品预处理。该法与消化后常规FAAS法的测定结果一致。钙质量浓度在0~20 mg/L范围内与吸光度呈线性关系,检出限(S/N=3)为0.013 mg/L,加标回收率为98%~101%,相对标准偏差(n=6)小于2%。方法应用于实际样品的测定,结果令人满意。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号