首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Hydrogen peroxide (H2O2) is popularly employed as a reaction reagent in cleaning processes for the chemical industry and semiconductor plants. By using differential scanning calorimetry (DSC) and vent sizing package 2 (VSP2), this study focused on the thermal decomposition reaction of H2O2 mixed with sulfuric acid (H2SO4) with low (0.1, 0.5 and 1.0 N), and high concentrations of 96 mass%, respectively. Thermokinetic data, such as exothermic onset temperature (T 0), heat of decomposition (ΔH d), pressure rise rate (dP/dt), and self-heating rate (dT/dt), were obtained and assessed by the DSC and VSP2 experiments. From the thermal decomposition reaction on various concentrations of H2SO4, the experimental data of T 0, ΔH, dP/dt, and dT/dt were obtained. Comparisons of the reactivity for H2O2 and H2O2 mixed with H2SO4 (lower and higher concentrations) were evaluated to corroborate the decomposition reaction in these systems.  相似文献   

2.
Chromium speciation has attracted attention because of the different toxicity of Cr(III), which is considered relatively non-toxic, and Cr(VI), which can cross cell membranes mainly as a chromate anion and has been classified as a class I human carcinogen. The aims of the present study were to measure soluble Cr(VI) levels in environmental samples, to develop a simple method of quantifying Cr(VI) in exhaled breath condensate (EBC), and to follow the kinetics of EBC Cr(VI) in chrome plating workers.Personal air samples were collected from 10 chrome platers; EBC was collected from the same workers immediately after the work shift on Tuesday and before the work shift on the following Wednesday. Environmental and EBC Cr(VI) levels were determined by means of colorimetry and electrothermal absorption atomic spectrometry, respectively.The method of detecting Cr(VI) in environmental air was based on the extraction of the Cr(VI)-diphenylcarbazide (Cr(VI)-DPC) complex in 1-butanol, whereas EBC Cr(VI) was determined using a solvent extraction of Cr(VI) as an ion pair with tetrabutylammonium ion, and subsequent direct determination of the complex (Cr(VI)-DPC) in EBC.Kinetic data showed that airborne Cr(VI) was reduced by 50% in airway lining fluid sampled at the end of exposure and that there was a further 50% reduction after about 15 h. The persistence of Cr(VI) in EBC supports the use of EBC in assessing target tissue levels of Cr(VI).  相似文献   

3.
Application of hollow fiber-based electromembrane extraction was studied for extraction and quantification of phenytoin from exhaled breath condensate (EBC). Phenytoin is extracted from EBC through a supported liquid membrane consisting of 1-octanol impregnated in the walls of a hollow fiber, and into an alkaline aqueous acceptor solution inside the lumen of the fiber. Under the obtained conditions of electromembrane extraction, that is, the extraction time of 15 min, stirring speed of 750 rpm, donor phase pH at 11.0, acceptor pH at 13.0, and an applied voltage of 15 V across the supported liquid membrane, an enrichment factor of 102-fold correspond to extraction percent of 25.5% was achieved. Good linearity was obtained over the concentration range of 0.001–0.10 µg/mL (r2 = 0.9992). Limits of detection and quantitation were 0.001 and 0.003 µg/mL, respectively. The proposed method was successfully applied to determine phenytoin from EBC samples of patients receiving the drug. No interfering peaks were detected that indicating excellent selectivity of the method. The intra- and interday precisions (RSDs) were less than 14%.  相似文献   

4.
The kinetics of the decomposition of hydrogen peroxide was studied in aqueous medium in the temperature range 25–40°C in the presence of Wofatit KPS-resin in the form of Cu(II)-ammine complex ions. The rate constant was deduced at various degrees of resin cross-linkage and different concentrations of hydrogen peroxide. The order of the decomposition reaction varied from first order to half order, i.e., the order of the reaction decreased with increasing the concentration of H2O2. The decomposition process was found to be a catalytic reaction which was controlled by the chemical reaction of H2O2 molecules with the active species inside the resin particles. The mechanism of the reaction can be summarized by the equation in which the subsequent reactions of the probable active complex are discussed.  相似文献   

5.
A straightforward, efficient, and selective oxidation of sulfide to sulfoxide with 30% H2O2 catalyzed by copper(II)–Schiff base complex is described. The reactions proceed under mild conditions in acetonitrile at room temperature to provide a variety of aryl and alkyl sulfoxides in excellent yield.  相似文献   

6.
Spectrofluorimetric determination of hydrogen peroxide scavenging activity   总被引:1,自引:0,他引:1  
Homovanillic acid (HVA) is widely used for the detection and imaging of oxidative enzymes—peroxidase, glucose oxidase and xanthine oxidase, but antioxidant activity has not been determined so far with the use of HVA. We have developed a simple, sensitive and in-field spectrofluorimetric method for the determination of hydrogen peroxide (H2O2) scavenging activity. The assay is based on the oxidation of HVA to its fluorescent biphenyl dimer in the presence of H2O2 and peroxidase. The presence of substances with H2O2 scavenging activity prevents the oxidation of HVA by removing H2O2. The decrease in fluorescence intensity is proportional to the antioxidative (H2O2 scavenging) activity. The method was evaluated using Trolox (6-hydroxy-2,5,7,8-tetramethylchromane-2-carboxylic acid), BHA (3-t-butyl-4-hydroxyanisole) and ferulic, vanillic, caffeic, chlorogenic, protocatechuic and oxalic acids. Additionally, tea and herb infusions known for their antioxidant properties were evaluated.  相似文献   

7.
Environmentally friendly oxidations of various organic compounds with the hydrogen peroxide (H2O2)/methyltrioxorhenium (CH3ReO3, MTO) catalytic system have been described in dimethyl carbonate (DMC), a cheap commercially available and benign chemical having interesting solvating properties, low toxicity and high biodegradability. Oxidations proceeded with good conversions and in good yields. Spectrophotometric analysis demonstrated that the [CH3ReO(O-O)2] complex was formed in DMC and that it was stable for several days at room temperature.  相似文献   

8.
Qian L  Yang X 《Talanta》2006,68(3):721-727
A new amperometric biosensor for hydrogen peroxide was developed based on cross-linking horseradish peroxidase (HRP) by glutaraldehyde with multiwall carbon nanotubes/chitosan (MWNTs/chitosan) composite film coated on a glassy carbon electrode. MWNTs were firstly dissolved in a chitosan solution. Then the morphology of MWNTs/chitosan composite film was characterized by field-emission scanning electron microscopy. The results showed that MWNTs were well soluble in chitosan and robust films could be formed on the surface. HRP was cross-linked by glutaraldehyde with MWNTs/chitosan film to prepare a hydrogen peroxide biosensor. The enzyme electrode exhibited excellent electrocatalytic activity and rapid response for H2O2 in the absence of a mediator. The linear range of detection towards H2O2 (applied potential: −0.2 V) was from 1.67 × 10−5 to 7.40 × 10−4 M with correction coefficient of 0.998. The biosensor had good repeatability and stability for the determination of H2O2. There were no interferences from ascorbic acid, glucose, citrate acid and lactic acid.  相似文献   

9.
Zheng L  Xiong L  Zheng D  Li Y  Liu Q  Han K  Liu W  Tao K  Yang S  Xia J 《Talanta》2011,85(1):43-48
In this paper, a polydopamine (PDA) film is electropolymerized on the surface of bilayer lipid membrane (BLM) which is immobilized with horseradish peroxidase (HRP). The coverage of the PDA film on HRP/BLM electrode is monitored by electrochemical impedance spectroscopy (EIS). The electrocatalytic reduction of H2O2 at the PDA/HRP/BLM electrode is studied by means of cyclic voltammetry (CV). The biosensor has a fast response to H2O2 of less than 5 s and an excellent linear relationship is obtained in the concentration range from 2.5 × 10−7 to 3.1 × 10−3 mol L−1, with a detection limit of 1.0 × 10−7 mol L−1 (S/N = 3). The response current of BLM/HRP/PDA biosensor retains 84% of its original response after being stored in 0.1 mol L−1 pH 7.0 PBS at 4 °C for 3 weeks. The selectivity, repeatability, and storage stability of PDA/HRP/BLM biosensor are greatly enhanced by the coverage of polydopamine film on BLM.  相似文献   

10.
Gao Y  Wang G  Huang H  Hu J  Shah SM  Su X 《Talanta》2011,85(2):1075-1080
In this paper, we utilized the instinct peroxidase-like property of Fe3O4 magnetic nanoparticles (MNPs) to establish a new fluorometric method for determination of hydrogen peroxide and glucose. In the presence of Fe3O4 MNPs as peroxidase mimetic catalyst, H2O2 was decomposed into radical that could quench the fluorescence of CdTe QDs more efficiently and rapidly. Then the oxidization of glucose by glucose oxidase was coupled with the fluorescence quenching of CdTe QDs by H2O2 producer with Fe3O4 MNPs catalyst, which can be used to detect glucose. Under the optimal reaction conditions, a linear correlation was established between fluorescence intensity ratio I0/I and concentration of H2O2 from 1.8 × 10−7 to 9 × 10−4 mol/L with a detection limit of 1.8 × 10−8 mol/L. And a linear correlation was established between fluorescence intensity ratio I0/I and concentration of glucose from 1.6 × 10−6 to 1.6 × 10−4 mol/L with a detection limit of 1.0 × 10−6 mol/L. The proposed method was applied to the determination of glucose in human serum samples with satisfactory results.  相似文献   

11.
Jing Sui  Wei Li 《Soft Materials》2018,16(3):201-208
Pt nanoparticles (PtNPs)/polypyrole (PPy) composites were successfully prepared through a facile one-pot interfacial polymerization of pyrrole by using H2PtCl6 as the oxidant for the first time. The as-prepared PPy was granular particles with particle size within a few hundred nanometers, on which PtNPs (1.7–3.5) nm were homogeneously dispersed. The PtNPs/PPy composites displayed excellent electrocatalytic activity toward redox of H2O2. The non-enzyme sensor constructed with PtNPs/PPy composites displayed good sensing ability toward H2O2 at ?0.1 V with a significantly high sensitivity of 6056 μAmM?1cm?2 and a low detection limit of 1.8 μM (S/N = 3).  相似文献   

12.
Metallic nanoparticles of rhodium were prepared by using the newly synthesized N,N-bis-succinamide-based dendrimer as stabilizers. The Rh nanoparticles were spherical shaped with a particle size of ∼2 nm. The dendrimer Rh-encapsulated nanoparticles (Rh-DENs) were immobilized on glassy carbon electrode (GCE) and their electrocatalytic activity towards hydrogen peroxide reduction was investigated using cyclic voltammetry and chronoamperometry. The Rh-DENs modified GCE showed excellent electrocatalytic activity for hydrogen peroxide reduction reactions. The steady-state cathodic current response of the modified electrode at −0.3 V (vs SCE) in phosphate buffer (pH 7.0) showed a linear response to hydrogen peroxide concentration ranging from 8 to 30 μM with a detection limit and sensitivity of 5 μM and 0.03103 × 10−6 A μM−1, respectively.  相似文献   

13.
Information about the kinetics and thermal decomposition of hydrogen peroxide (H2O2) has been required for safety reasons, due to its broad applications in many chemical industries. To determine the inherent hazards during H2O2 manufacturing, transportation, disposal, usage, and so on, this study deliberately selected various H2O2 concentrations and analyzed them by differential scanning calorimetry (DSC). In addition, thermokinetic parameters were not only established for each of these reactions, but also aimed at comprehensive, kinetic models with various tests conducted at different heating rates. To build up a comprehensive kinetic model, various tests were conducted by heating rates of 1, 2, 4, 10°C min–1, respectively. According to dynamic DSC tests, the experimental curves show that H2O2 decomposition has one exothermic peak and may start to decompose under 47–81°C. The total heat of decomposition is about 192–1079 J g–1. Not only can these results prevent accidents caused by H2O2 during storage and transportation, but also assess its inherent hazards and thereby design procedures for emergency response while runaway reactions occurring.  相似文献   

14.
Limiao Li  Taihong Wang 《Talanta》2010,82(5):1637-1641
A new electrocatalyst, MnO2/graphene oxide hybrid nanostructure was successfully synthesized for the nonenzymatic detection of H2O2. The morphological characterization was examined by scanning electron microscopy and transmission electron microscopy. The MnO2/graphene oxide based electrodes showed high electrochemical activity for the detection of H2O2 in alkaline medium. The nonenzymatic biosensors displayed good performance along with low working potential, high sensitivity, low detection limit, and long-term stability, which could be attributed to the high surface area of graphene oxide providing for the deposition of MnO2 nanoparticles. These results demonstrate that this new nanocomposite with the high surface area and electrocatalytic activity offers great promise for new class of nanostructured electrode for nonenzymatic biosensor and energy conversion applications.  相似文献   

15.
Copper(II) complex 1 catalyzes the oxidation of sulfides to sulfoxides with 30% H2O2 in high yields. Addition of a catalytic amount of TEMPO to the reaction mixture enhances the conversion and selectivity. Complex 1 can be recycled without loss of activity.  相似文献   

16.
Ketones were efficiently converted into the corresponding gem-dihydroperoxides in high yields within a short period of time on treatment with aqueous H2O2 (50%) in the presence of a catalytic amount of CAN in acetonitrile at room temperature.  相似文献   

17.
Reactive oxygen species (ROS) have captured the interest of many researchers in the chemical, biological, and medical fields since they are thought to be associated with various pathological conditions. Fluorescent probes for the detection of ROS are promising tools with which to enhance our understanding of the physiological roles of ROS, because they provide spatial and temporal information about target biomolecules in in vivo cellular systems. ROS probes, designed to detect specific ROS with a high selectivity, would be desirable, since it is now becoming clear that each ROS has its own unique physiological activity. However, dihydro-compounds such as 2′,7′-dichlorodihydrofluorescein (DCFH), which have traditionally been used for detecting ROS, tend to react with a wide variety of ROS and are not completely photostable. Some attractive fluorescent probes that exhibit a high degree of selectivity toward specific ROS have recently been reported, and these selective probes are expected to have great potential for elucidating unknown physiological mechanisms associated with their target ROS. This review focuses on the design, detection mechanism, and performance of fluorescent probes for the detection of singlet oxygen (1O2), hydrogen peroxide (H2O2), hydroxyl radicals (.OH), or superoxide anion (O2 −.), a field in which remarkable progress has been achieved in the last few years.  相似文献   

18.
Lauroyl peroxide (LPO) is a typical organic peroxide that has caused many thermal runaway reactions and explosions. Differential scanning calorimetry (DSC) was employed to determine the fundamental thermokinetic parameters that involved exothermic onset temperature (T0), heat of decomposition (ΔHd), and other safety parameters for loss prevention of runaway reactions and thermal explosions. Frequency factor (A) and activation energy (Ea) were calculated by Kissinger model, Ozawa equation, and thermal safety software (TSS) series via DSC experimental data. Liquid thermal explosion (LTE) by TSS was employed to simulate the thermal explosion development for various types of storage tank. In view of loss prevention, calorimetric application and model analysis to integrate thermal hazard development were necessary and useful for inherently safer design.  相似文献   

19.
Summary Electronic structure of hydrogen nitryl HNO2, a yet not identified entity, and the path of its possible isomerization totrans-HONO have been investigated byab initio SCF and MRD-CI computations using the 6-31G** basis set. HNO2 isC 2v -symmetric and its ground state (1 A 1) is less stable thantrans-HONO by 66 kJ/mol (with the SCF vibrational zero-point energy correction). The lowest two excited singlet states (1 A 2 and1 B 1) are nearly degenerate, their vertical excitation energies being predicted to be 4.8 eV. The isomerization path is traced by the CASSCF procedure and the activation barrier height is evaluated by the CI treatment. HNO2 in its ground state isomerizes totrans-HONO by maintaining the planar (C s-symmetric) structure. The activation energy is calculated to be 171 kJ/mol, which is clearly lower than the calculated H-N bond energy (253 kJ/mol). The transition state seems to be more adequately described as an interacting system of proton and the nitrite anion rather than as a pair of two fragment radicals.  相似文献   

20.
In this report, carbon-based gold core silver shell Au-Ag bimetallic nanocomposite (Au-Ag/C NC) was synthesized using carbon dots (C-dots) as the reductant and stabilizer by a facile green sequential reduction approach. The structure and morphology of the nanocomposite are characterized by ultraviolet–visible spectroscopy (UV–Vis), Fourier transform infrared spectroscopy (FT-IR) and transmission electron microscopy (TEM). The as synthesized Au-Ag/C NC exhibits good optic response toward hydrogen peroxide (H2O2) without adding any other chromogenic agents. The characteristic surface plasmon resonance (SPR) absorbance peak of Au-Ag/C NC declined and red-shifted with the solution color changing from reddish orange to light pink when adding H2O2 owing to the etching effect of H2O2 towards Ag. Thus, a simple colorimetric and UV strategy for sensitive detection of H2O2 is proposed. It provides the wide linear range for detection of H2O2 from 0.8–90 μM and 90–500 μM, and the detection limit was as low as 0.3 μM (S/N = 3). In addition, this colorimetric strategy can also be applied to directly distinguish and detect of lactate by naked eye and UV–Vis. The linear range of colorimetric sensing towards lactate was 0.1–22 μM and 22–220 μM, which was successfully applied in the analysis of lactate in human serum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号