首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The response of an intrinsic Ge detector in energy‐dispersive diffraction measurements with synchrotron radiation is studied with model calculations and diffraction from perfect Si single‐crystal samples. The high intensity and time‐structure of the synchrotron radiation beam leads to pile‐up of the output pulses, and the energy distribution of the pile‐up pulses is characteristic of the fill pattern of the storage ring. The pile‐up distribution has a single peak and long tail when the interval of the radiation bunches is small, as in the uniform fill pattern, but there are many pile‐up peaks when the bunch distance is a sizable fraction of the length of the shaping amplifier output pulse. A model for the detecting chain response is used to resolve the diffraction spectrum from a perfect Si crystal wafer in the symmetrical Laue case. In the 16‐bunch fill pattern of the ESRF storage ring the spectrum includes a large number of `extra reflections' owing to pile‐up, and the model parameters are refined by a fit to the observed energy spectrum. The model is used to correct for the effects of pile‐up in a measurement with the 1/3 fill pattern of the storage ring. Si reflections (2h,2h,0) are resolved up to h = 7. The pile‐up corrections are very large, but a perfect agreement with the integrated intensities calculated from dynamical diffraction theory is achieved after the corrections. The result also demonstrates the convergence of kinematical and dynamical theories at the limit where the extinction length is much larger than the effective thickness of the perfect crystal. The model is applied to powder diffraction using different fill patterns in simulations of the diffraction pattern, and it is demonstrated that the regularly spaced pile‐up peaks might be misinterpreted to arise from superlattices or phase transitions. The use of energy‐dispersive diffraction in strain mapping in polycrystalline materials is discussed, and it is shown that low count rates but still good statistical accuracy are needed for reliable results.  相似文献   

2.
The design and performance characterization of a new light‐weight and compact X‐ray scintillation detector is presented. The detectors are intended for use on the new I11 powder diffraction beamline at the third‐generation Diamond synchrotron facility where X‐ray beams of high photon brightness are generated by insertion devices. The performance characteristics of these detection units were measured first using a radioactive source (efficiency of detection and background count rate) and then synchrotron X‐rays (peak stability, light yield linearity and response consistency). Here, the results obtained from these tests are reported, and the suitability of the design for the Diamond powder beamline is demonstrated by presenting diffraction data obtained from a silicon powder standard using a prototype multicrystal analyser stage.  相似文献   

3.
Small‐angle X‐ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon‐counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame?1 or 826 ns frame?1 followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi‐speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm‐radius gold and 57 nm‐radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one‐ and two‐photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. It was found that in burst mode the ratio of 2 s to 1 s is markedly smaller than predicted and that this is attributable to pixel‐response dead‐time.  相似文献   

4.
The Pixium 4700 detector represents a significant step forward in detector technology for high‐energy X‐ray diffraction. The detector design is based on digital flat‐panel technology, combining an amorphous Si panel with a CsI scintillator. The detector has a useful pixel array of 1910 × 2480 pixels with a pixel size of 154 µm × 154 µm, and thus it covers an effective area of 294 mm × 379 mm. Designed for medical imaging, the detector has good efficiency at high X‐ray energies. Furthermore, it is capable of acquiring sequences of images at 7.5 frames per second in full image mode, and up to 60 frames per second in binned region of interest modes. Here, the basic properties of this detector applied to high‐energy X‐ray diffraction are presented. Quantitative comparisons with a widespread high‐energy detector, the MAR345 image plate scanner, are shown. Other properties of the Pixium 4700 detector, including a narrow point‐spread function and distortion‐free image, allows for the acquisition of high‐quality diffraction data at high X‐ray energies. In addition, high frame rates and shutterless operation open new experimental possibilities. Also provided are the necessary data for the correction of images collected using the Pixium 4700 for diffraction purposes.  相似文献   

5.
Solution small‐angle X‐ray scattering (SAXS) measurements were obtained using a 128 × 128 pixel X‐ray mixed‐mode pixel array detector (MMPAD) with an 860 µs readout time. The MMPAD offers advantages for SAXS experiments: a pixel full‐well of >2 × 107 10 keV X‐rays, a maximum flux rate of 108 X‐rays pixel?1 s?1, and a sub‐pixel point‐spread function. Data from the MMPAD were quantitatively compared with data from a charge‐coupled device (CCD) fiber‐optically coupled to a phosphor screen. MMPAD solution SAXS data from lysozyme solutions were of equal or better quality than data captured by the CCD. The read‐noise (normalized by pixel area) of the MMPAD was less than that of the CCD by an average factor of 3.0. Short sample‐to‐detector distances were required owing to the small MMPAD area (19.2 mm × 19.2 mm), and were revealed to be advantageous with respect to detector read‐noise. As predicted by the Shannon sampling theory and confirmed by the acquisition of lysozyme solution SAXS curves, the MMPAD at short distances is capable of sufficiently sampling a solution SAXS curve for protein shape analysis. The readout speed of the MMPAD was demonstrated by continuously monitoring lysozyme sample evolution as radiation damage accumulated. These experiments prove that a small suitably configured MMPAD is appropriate for time‐resolved solution scattering measurements.  相似文献   

6.
A prototype ePix100 detector was used in small‐angle scattering geometry to capture speckle patterns from a static sample using the Linac Coherent Light Source (LCLS) hard X‐ray free‐electron laser at 8.34 keV. The average number of detected photons per pixel per pulse was varied over three orders of magnitude from about 23 down to 0.01 to test the detector performance. At high average photon count rates, the speckle contrast was evaluated by analyzing the probability distribution of the pixel counts at a constant scattering vector for single frames. For very low average photon counts of less than 0.2 per pixel, the `droplet algorithm' was first applied to the patterns for correcting the effect of charge sharing, and then the pixel count statistics of multiple frames were analyzed collectively to extract the speckle contrast. Results obtained using both methods agree within the uncertainty intervals, providing strong experimental evidence for the validity of the statistical analysis. More importantly it confirms the suitability of the ePix100 detector for X‐ray coherent scattering experiments, especially at very low count rates with performances surpassing those of previously available LCLS detectors.  相似文献   

7.
微通道板作为二维位置灵敏阳极光子计数探测器中的电子倍增器件,其增益特性直接影响探测器的成像性能。搭建了系统测试平台,测量了微通道板的增益随电压变化曲线,并获得了3块微通道板叠加后的脉冲高度分布曲线。根据测试结果以及脉冲高度分布曲线的能量分辨率与探测器增益的均匀性之间的物理关系,选择合适电压值和增益对探测器的性能进行优化,探测器分辨率由3.56 lp/mm 提高到4.49 lp/mm ,获得了清晰图像,为探测器的研制提供了技术支持。  相似文献   

8.
A three‐dimensional X‐ray detector for imaging 30–200 keV photons is described. It comprises a set of semi‐transparent structured scintillators, where each scintillator is a regular array of waveguides in silicon, and with pores filled with CsI. The performance of the detector is described theoretically and explored in detail through simulations. Based on available hardware, a spatial resolution of 1 µm is obtainable. The resolution of a single screen is shown to be determined only by the pitch, at least up to 100 keV. In comparison with conventional homogeneous screens, an improvement in efficiency by a factor of 5–15 is obtainable. The cross‐talk between screens in the three‐dimensional detector is shown to be negligible. The three‐dimensional concept enables ray‐tracing and super‐resolution algorithms to be applied.  相似文献   

9.
This study analyses the potential for laboratory‐based size‐exclusion chromatography (SEC) integrated small‐angle X‐ray scattering (SAXS) instrumentation to characterize protein complexes. Using a high‐brilliance home source in conjunction with a hybrid pixel X‐ray detector, the efficacy of SAXS data collection at pertinent protein concentrations and exposure times has been assessed. Scattering data from SOD1 and from the complex of SOD1 with its copper chaperone, using 10 min exposures, provided data quality in the range 0.03 < q < 0.25 Å?1 that was sufficient to accurately assign radius of gyration, maximum dimension and molecular mass. These data demonstrate that a home source with integrated SEC–SAXS technology is feasible and would enable structural biologists studying systems containing transient protein complexes, or proteins prone to aggregation, to make advanced preparations in‐house for more effective use of limited synchrotron beam time.  相似文献   

10.
A silicon pixel detector with fine pitch size of 19 μm× 19 μm, developed based on SOI(silicon-oninsulator) technology, was tested under the illumination of infrared laser pulses. As an alternative method for particle beam tests, the laser pulses were tuned to very short duration and small transverse profile to simulate the tracks of MIPs(minimum ionization particles) in silicon. Hit cluster sizes were measured with focused laser pulses propagating through the SOI detector perpendicular to its surface and most of the induced charge was found to be collected inside the seed pixel. For the first time, the signal amplitude as a function of the applied bias voltage was measured for this SOI detector, deepening understanding of its depletion characteristics.  相似文献   

11.
The detection of low-level light is a key technology in various experimental scientific studies. As a photon detector, the silicon photomultiplier (SiPM) has gradually become an alternative to the photomultiplier tube (PMT) in many applications in high-energy physics, astroparticle physics, and medical imaging because of its high photon detection efficiency (PDE), good resolution for single-photon detection, insensitivity to magnetic field, low operating voltage, compactness, and low cost. However, primarily because of the geometric fill factor, the PDE of most SiPMs is not very high; in particular, for those SiPMs with a high density of micro cells, the effective area is small, and the bandwidth of the light response is narrow. As a building block of the SiPM, the concept of the backside-illuminated avalanche drift detector (ADD) was first proposed by the Max Planck Institute of Germany eight years ago; the ADD is promising to have high PDE over the full energy range of optical photons, even ultraviolet light and X-ray light, and because the avalanche multiplication region is very small, the ADD is beneficial for the fabrication of large-area SiPMs. However, because of difficulties in design and fabrication, no significant progress had been made, and the concept had not yet been verified. In this paper, preliminary results in the design, fabrication, and performance of a backside-illuminated ADD are reported; the difficulties in and limitations to the backside-illuminated ADD are analyzed.  相似文献   

12.
A synchrotron beam has been used to investigate the radiation tolerance of a PILATUS II module. It has been demonstrated that radiation‐induced threshold shifts become significant above 30 Mrad. Individual adjustment of pixel thresholds after irradiation enabled retention of standard behaviour in excess of 40 Mrad. This implies that a module can be continuously irradiated for in excess of 40 days at an individual pixel count rate of 106 counts s?1.  相似文献   

13.
<正>The performance of single-photon detectors can be enhanced by using nano-antenna.The characteristics of the superconducting nano-wire single-photon detector with cavity plus anti-reflect coating and specially designed nanoantenna is analysed.The photon collection efficiency of the detector is enhanced without damaging the detector’s speed,thus getting rid of the dilemma of speed and efficiency.The characteristics of nano-antenna are discussed,such as the position and the effect of the active area,and the best result is given.The photon collection efficiency is increased by 92 times compared with that of existing detectors.  相似文献   

14.
The developed curved image plate (CIP) is a one‐dimensional detector which simultaneously records high‐resolution X‐ray diffraction (XRD) patterns over a 38.7° 2θ range. In addition, an on‐site reader enables rapid extraction, transfer and storage of X‐ray intensity information in ≤30 s, and further qualifies this detector to study kinetic processes in materials science. The CIP detector can detect and store X‐ray intensity information linearly proportional to the incident photon flux over a dynamical range of about five orders of magnitude. The linearity and uniformity of the CIP detector response is not compromised in the unsaturated regions of the image plate, regardless of saturation in another region. The speed of XRD data acquisition together with excellent resolution afforded by the CIP detector is unique and opens up wide possibilities in materials research accessible through X‐ray diffraction. This article presents details of the basic features, operation and performance of the CIP detector along with some examples of applications, including high‐temperature XRD.  相似文献   

15.
The first application of a pnCCD detector for X‐ray scattering experiments using white synchrotron radiation at BESSY II is presented. A Cd arachidate multilayer was investigated in reflection geometry within the energy range 7 keV < E < 35 keV. At fixed angle of incidence the two‐dimensional diffraction pattern containing several multilayer Bragg peaks and respective diffuse‐resonant Bragg sheets were observed. Since every pixel of the detector is able to determine the energy of every incoming photon with a resolution ΔE/E? 10?2, a three‐dimensional dataset is finally obtained. In order to achieve this energy resolution the detector was operated in the so‐called single‐photon‐counting mode. A full dataset was evaluated taking into account all photons recorded within 105 detector frames at a readout rate of 200 Hz. By representing the data in reciprocal‐space coordinates, it becomes obvious that this experiment with the pnCCD detector provides the same information as that obtained by combining a large number of monochromatic scattering experiments using conventional area detectors.  相似文献   

16.
Combined X‐ray photon correlation spectroscopy (XPCS) and diffracted X‐ray tracking (DXT) measurements of carbon‐black nanocrystals embedded in styrene–butadiene rubber were performed. From the intensity fluctuation of speckle patterns in a small‐angle scattering region (XPCS), dynamical information relating to the translational motion can be obtained, and the rotational motion is observed through the changes in the positions of DXT diffraction spots. Graphitized carbon‐black nanocrystals in unvulcanized styrene–butadiene rubber showed an apparent discrepancy between their translational and rotational motions; this result seems to support a stress‐relaxation model for the origin of super‐diffusive particle motion that is widely observed in nanocolloidal systems. Combined measurements using these two techniques will give new insights into nanoscopic dynamics, and will be useful as a microrheology technique.  相似文献   

17.
刘利  郁海  郑伟 《中国物理 C》2014,38(3):41-46
Detecting the X-ray emission of pulsars and obtaining the photons' time of arrival are the foundational steps in autonomous navigation via X-ray pulsar measurement. The precision of a pulse's time of arrival is mainly determined by the precision of photon arrival time measurement. In this work, a silicon drift detector is used to measure photon energy and arrival time. The measurement system consists of a signal detector, a processing unit, a signal acquisition unit and a data receiving unit. This system acquires the energy resolution and arrival time information of photons. In particular, background noise with different energies disturbs pulse profile forming, the system can also achieve a high signal-to-noise ratio profile. Ground test results show that this system can be applied in autonomous navigation based on X-ray pulsar measurement.  相似文献   

18.
X‐ray detectors that combine two‐dimensional spatial resolution with a high time resolution are needed in numerous applications of synchrotron radiation. Most detectors with this combination of capabilities are based on semiconductor technology and are therefore limited in size. Furthermore, the time resolution is often realised through rapid time‐gating of the acquisition, followed by a slower readout. Here, a detector technology is realised based on relatively inexpensive microchannel plates that uses GHz waveform sampling for a millimeter‐scale spatial resolution and better than 100 ps time resolution. The technology is capable of continuous streaming of time‐ and location‐tagged events at rates greater than 107 events per cm2. Time‐gating can be used for improved dynamic range.  相似文献   

19.
The high brilliance of third‐generation synchrotron sources increases the demand for faster detectors to utilize the available flux. The Maia detector is an advanced imaging scheme for energy‐dispersive detection realising dwell times per image‐pixel as low as 50 µs and count rates higher than 10 × 106 s?1. In this article the integration of such a Maia detector in the Microprobe setup of beamline P06 at the storage ring PETRA III at the Deutsches Elektronen‐Synchrotron (DESY) in Hamburg, Germany, is described. The analytical performance of the complete system in terms of rate‐dependent energy resolution, scanning‐speed‐dependent spatial resolution and lower limits of detection is characterized. The potential of the Maia‐based setup is demonstrated by key applications from materials science and chemistry, as well as environmental science with geological applications and biological questions that have been investigated at the P06 beamline.  相似文献   

20.
This paper presents the performance of a single‐photon‐counting hybrid pixel X‐ray detector with synchrotron radiation. The camera was evaluated with respect to time‐resolved experiments, namely pump–probe–probe experiments held at SOLEIL. The UFXC camera shows very good energy resolution of around 1.5 keV and allows the minimum threshold setting to be as low as 3 keV keeping the high‐count‐rate capabilities. Measurements of a synchrotron characteristic filling mode prove the proper separation of an isolated bunch of photons and the usability of the detector in time‐resolved experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号