1.
The measurement of the chemical species of elements (instead of the total element concentration) has become an irreversible trend in analytical chemistry. The motivation lies in the fact that the biochemical and geochemical behaviour of an element is governed by its species. Quality assurance of the analytical procedures used for speciation analysis requires the analysis of representative reference materials, certified for the relevant species. Up to now the number of existing certified reference materials for trace element species is very limited. The most important ones are environmental CRMs certified for trialkyltin compounds, methylmercury, Cr(III)/Cr(VI) and food CRMs certified for arsenic species and methylmercury. Major developments are to be expected in CRMs focussed on environmental problems, including waste treatment, on bioavailability of trace elements in food and on bio-monitoring in occupational health and hygiene. It is, however, unlikely that the producers of CRMs will ever be able to cover all needs. Add to this that many, very active species are notoriously unstable and/or short living and require in-situ analysis. This will lead to different analytical developments, such as analyses in-situ, where the classical concept of CRMs may not stand firm anymore.  相似文献   

2.
Matrix certified reference materials (CRMs) are playing an increasingly important role in environmental monitoring in Japan. The National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) has been developing matrix CRMs for environmental monitoring since 2001, and has issued nine kinds of CRMs as NMIJ CRMs. The development of the CRMs was conducted in NMIJ in cooperation with candidate material producers. The isotope dilution mass spectrometry (IDMS) was principally adopted to give reliable certified values. Meanwhile, two or more analytical methods, whose levels of accuracy were well evaluated, were applied to avoid any possible analytical bias. Two typical certification processes, the certification of river water CRMs for trace element analysis and that of marine sediment CRMs for PCB and organochlorine pesticide analysis, are outlined as examples. Presented at -- “BERM-10” -- April 2006, Charleston, SC, USA.  相似文献   

3.
Increasing numbers of clinical laboratories are transitioning away from flame and electrothermal AAS methods to those based on ICP-MS. Still, for many laboratories, the choice of instrumentation is based upon (a) the element(s) to be determined, (b) the matrix/matrices to be analyzed, and (c) the expected concentration(s) of the analytes in the matrix. Most clinical laboratories specialize in measuring Se, Zn, Cu, and Al in serum, and/or Pb, Cd, Hg, As, and Cr in blood and/or urine, while other trace elements (e.g., Pt, Au etc.) are measured for therapeutic purposes. Quantitative measurement of elemental species is becoming more widely accepted for nutritional and/or toxicological screening purposes, and ICP-MS interfaced with separation techniques, such as liquid chromatography or capillary electrophoresis, offers the advantage of on-line species determination coupled with very low detection limits. Polyatomic interferences for some key elements such as Se, As, and Cr require instrumentation equipped with dynamic reaction cell or collision cell technologies, or might even necessitate the use of sector field ICP-MS, to assure accurate results. Nonetheless, whatever analytical method is selected for the task, careful consideration must be given both to specimen collection procedures and to the control of pre-analytical variables. Finally, all methods benefit from access to reliable certified reference materials (CRMs). While a variety of reference materials (RMs) are available for trace element measurements in clinical matrices, not all can be classified as CRMs. The major metrological organizations (e.g., NIST, IRMM, NIES) provide a limited number of clinical CRMs, however, secondary reference materials are readily available from commercial organizations and organizers of external quality assessment schemes.  相似文献   

4.
Levels of essential and toxic trace elements in six marine species greatly in demand in the international market (canned pink clams, razor clams, clams, king crab, sardines, and frozen albacore tuna fish) were studied. A special laboratory adequately equipped for handling and preparing biological materials, is described. The elements As, Br, Na, Se, Hg, Cr, Fe, Zn and Rb were determined by INAA, while copper and cadmium content were determined using RNAA. Significant differences were found on comparing the contents of some toxic elements in mollusk and other samples of marine food. Various certified reference materials (CRMs) of the IAEA, NIST and NIES were analyzed for quality assurance purposes.  相似文献   

5.
In most chemical analyses for inorganic determinations in environmental matrices the sample is physically destroyed by dissolution, calcination etc. These digestion procedures have to be validated in order to ensure that no contamination and/or losses have occurred which could affect the accuracy of the final results obtained; this validation can be made by using certified reference materials (CRMs).In the recent past, microwave digestion procedures have been developed and have been shown to offer the benefits of rapid sample preparation and reduced contamination risks; however, an incomplete dissolution was suspected in some cases, e.g. in interlaboratory exercises, for the analysis of organic matrices.The aim of this study was to test microwave digestion procedures for different environmental CRMs and to evaluate the suitability of these methods for the determination of some trace elements. The effects of chemical species (As, Hg and Se-species) on the total element recovery after digestion are discussed.  相似文献   

6.
The environmental CRMs currently available from NRC Ottawa comprise four natural waters for trace elements, four biological tissues for trace elements and methylmercury, three marine sediments for major and trace elements (one sediment has certified values for butyltins) and one fish tissue for organochlorines (PCBs, dioxins). Although significant effort has been expended to maintain this suite of materials, several new initiatives have also recently been completed or are in progress. The certified value for arsenobetaine in Dogfish Muscle CRM DORM-2 has been established. The certification approaches, as well as the studies to determine extraction efficiency of this organoarsenic compound, are presented. A stability study has been completed for Hg in a natural water sample and plans are underway for production of a CRM. Assessment of micronutrient stability in seawater for the purposes of CRM production is continuing and progress on this initiative is discussed.  相似文献   

7.
The environmental CRMs currently available from NRC Ottawa comprise four natural waters for trace elements, four biological tissues for trace elements and methylmercury, three marine sediments for major and trace elements (one sediment has certified values for butyltins) and one fish tissue for organochlorines (PCBs, dioxins). Although significant effort has been expended to maintain this suite of materials, several new initiatives have also recently been completed or are in progress. The certified value for arsenobetaine in Dogfish Muscle CRM DORM-2 has been established. The certification approaches, as well as the studies to determine extraction efficiency of this organoarsenic compound, are presented. A stability study has been completed for Hg in a natural water sample and plans are underway for production of a CRM. Assessment of micronutrient stability in seawater for the purposes of CRM production is continuing and progress on this initiative is discussed.  相似文献   

8.
The concern for the control of toxic chemical forms of elements in the environment is reflected by an increasing number of analyses performed by research and routine laboratories. The European Commission has recognised the need to include some of these species in the list of dangerous substances to be monitored, e.g. in the marine environment or in groundwater. However, in most cases, the specifications are far from being sufficient in respect to the chemical forms of the element to be determined. Furthermore, these determinations are in most cases based on multi-step analytical techniques which are often prone to errors (e.g. at the extraction, derivatization or separation steps). Certified reference materials (CRMs) certified for their content in chemical forms of elements are, therefore, necessary to ensure the accuracy of these measurements and hence the respect of the regulations. However, the lack of CRMs for speciation analysis hampers the quality control of determinations which in turn leads to an incomparability of data produced; so far the number of CRMs produced by international organisations, e.g. NIST (USA), NIES (Japan), NRCC (Canada) and BCR (Belgium), is very limited and concerns mainly compounds such as e.g. methyl-mercury and butyltin compounds in biological matrices or sediments. The Standards, Measurements and Testing Programme (formerly BCR) of the European Commission has started a series of projects for the improvement of speciation analysis in environmental matrices, the final aim of which being the production of a variety of environmental CRMs. The existing EU legislation involving chemical forms of elements is presented, the requirements for the preparation of CRMs for speciation analysis are discussed and an update of the most recent CRMs produced within the Standards, Measurements and Testing Programme (SM&T) is given.  相似文献   

9.
The concern for the control of toxic chemical forms of elements in the environment is reflected by an increasing number of analyses performed by research and routine laboratories. The European Commission has recognised the need to include some of these species in the list of dangerous substances to be monitored, e.g. in the marine environment or in groundwater. However, in most cases, the specifications are far from being sufficient in respect to the chemical forms of the element to be determined. Furthermore, these determinations are in most cases based on multi-step analytical techniques which are often prone to errors (e.g. at the extraction, derivatization or separation steps). Certified reference materials (CRMs) certified for their content in chemical forms of elements are, therefore, necessary to ensure the accuracy of these measurements and hence the respect of the regulations. However, the lack of CRMs for speciation analysis hampers the quality control of determinations which in turn leads to an incomparability of data produced; so far the number of CRMs produced by international organisations, e.g. NIST (USA), NIES (Japan), NRCC (Canada) and BCR (Belgium), is very limited and concerns mainly compounds such as e.g. methyl-mercury and butyltin compounds in biological matrices or sediments. The Standards, Measurements and Testing Programme (formerly BCR) of the European Commission has started a series of projects for the improvement of speciation analysis in environmental matrices, the final aim of which being the production of a variety of environmental CRMs. The existing EU legislation involving chemical forms of elements is presented, the requirements for the preparation of CRMs for speciation analysis are discussed and an update of the most recent CRMs produced within the Standards, Measurements and Testing Programme (SM&T) is given.  相似文献   

10.
Radiochemical neutron activation analysis was used for determinationsof 8 rare earth elements (La, Ce, Nd, Sm, Eu, Tb, Yb and Lu) in two ChineseCRMs, GBW 08503 (wheat) and GBW 09101 (hair), and Cs, Sr, Th and U in fiveNIST SRMs, 1548 (Total Diet), 1486 (Bone Meal), 8414 (Bovine Muscle), 1566a(Oyster Powder) and 1575 (Pine Needles). These determinations are for eventualcertification of above ultratrace elements so far not certified. The radiochemicalseparation scheme used in RNAA of NIST SRMs is an anion exchange followedby the co-precipitation by (REE)F 3 for U and Th, and a SrSO 4 precipitationfor Sr and Cs. For RNAA of the two Chinese CRMs, a one step (REE)F 3 precipitationwas used. Chemical yields were determined for all relevant elements by tracerexperiments. All these materials were also analyzed by ICPMS, that offeredan opportunity to compare the two major trace analytical techniques on theirmerits and drawbacks for these particular cases. RNAA is proven to be oneof the important techniques in ultratrace analysis, especially in certificationof some ultratrace elements. Determination of elements in sub-ng/g level isstill an area to be further investigated because: (1) some such elements areimportant in food and health related environmental studies, (2) many of theseelements have no (or very few) certified values in existing biological CRMs,(3) reliable techniques qualified for ultratrace analysis are needed to beestablished, and (4) sampling behavior of elements at these levels is stillnot very well known (recommended minimum sample size may not be adequate).  相似文献   

11.
The intake of leafy vegetables in daily diet is very important to meet our nutritional needs. Vegetables provide the essential elements which are necessary and recommended for human growth. However, due to rapid industrialization and urbanization our environment becomes polluted and this affects the normal growth of agricultural products and composition of environmental species. The elemental concentrations present in the environmental samples are good indicators to assess the toxicological levels due to pollution affects. In the present work we have analysed several vegetable plant samples by instrumental neutron activation analysis to determine the elemental concentrations at major, minor and trace levels. The leafy vegetables like spinach, red leafy veagetable, pui, gourd leaf, lettuce and katoua were chosen as these are extensively consumed by local peple in eastern part of India. We have determined 15 elements in the above mentioned vegetable samples and some of these are essential elements and some are toxic elements. It was found that Na and K were present as major elements, Fe and Zn as minor elements and As, Ce, Cr, Co, La, Mo, Rb, Sc, Sm, Sr as trace elements. The concentration level of Cr was found to be higher than that of recommended value certified by WHO and National environment quality control for human consumption. The validation of our analytical results have been performed by the Z-score tests through the determination of concentrations of the elements of interest in certified reference materials.  相似文献   

12.
IAEA and NBS biological certified reference materials have been analyzed by instrumental neutron activation analysis and concentration of 17 elements was determined. The elements determined were either completely missing or their certified values were not given in the original compilations. For quality assurance of our work, a comparison of data on missing trace elements in some of the CRMs has been presented. It seems that second round of analysis for the certification of these elements would be useful.  相似文献   

13.
介绍0Cr18Ni10Ti、OCr18Ni12M02Ti、OCr17Ni4Cu4Nb、1Cr25Ni20Si2、1Cr13和2Cr13等6种典型不锈钢和耐热钢系列化学分析用标准物质的成分设计、制备工艺、定值方法及数据处理。采用中频感应炉冶炼.用F方差法检验均匀性,8家实验室采用不同分析方法协同定值。所研制的系列标准物质定值元素多,多数元素含量呈梯度分布,既可单独使用,也可成套使用。  相似文献   

14.
Dwinna Rahmi 《Talanta》2007,72(2):600-606
The multielement determination of trace metals in seawater was carried out by inductively coupled plasma mass spectrometry (ICP-MS) with aid of a down-sized chelating resin-packed minicolumn for preconcentration. The down-sized chelating resin-packed minicolumn was constructed with two syringe filters (DISMIC 13HP and Millex-LH) and an iminodiacetate chelating resin (Chelex 100, 200-400 mesh), with which trace metals in 50 mL of original seawater sample were concentrated into 0.50 mL of 2 M nitric acid, and then 100-fold preconcentration of trace metals was achieved. Then, 0.50 mL analysis solution was subjected to the multielement determination by ICP-MS equipped with a MicroMist nebulizer for micro-sampling introduction. The preconcentration and elution parameters such as the sample-loading flow rate, the amount of 1 M ammonium acetate for elimination of matrix elements, and the amount of 2 M nitric acid for eluting trace metals were optimized to obtain good recoveries and analytical detection limits for trace metals. The analytical results for V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U in three kinds of seawater certified reference materials (CRMs; CASS-3, NASS-4, and NASS-5) agreed well with their certified values. The observed values of rare earth elements (REEs) in the above seawater CRMs were also consistent with the reference values. Therefore, the compiled reference values for the concentrations of REEs in CASS-3, NASS-4, and NASS-5 were proposed based on the observed values and reference data for REEs in these CRMs.  相似文献   

15.
Direct analysis of solid samples employing a laboratory assembled electrothermal atomic absorption spectrometer is demonstrated to be a feasible approach for determination of trace elements in plant tissue and hair samples for special applications in plant physiology and biomedical research. As an example, the kinetics of Cr uptake by cabbage and its distribution have been measured as a function of chromium speciation in the nutrient solution. Further, longitudinal concentration gradients of Cr, Pb and Cd have been measured in hair of various population groups exposed to different levels of these elements in ambient and/or occupational environments. The techniques are validated for the determination of these trace elements by neutron activation analysis, dissolution atomic absorption spectrometry and by analysis of certified reference materials. Slurry sample introduction is found appropriate for routine trace element determination and in homogeneity testing. Direct sample introduction is indispensable in the analysis of very small (< 1 mg) tissue biopsy samples in the determination of trace element distributions.  相似文献   

16.
Several reference materials (RMs) and certified reference materials (CRMs) are widely used in Romania as measurement standards in different spectrochemical measurements. Among them, single element standard solution certified for their mass concentration play a key role in ensuring the required traceability of results expressed in this measurement unit. A short review of the locally available elemental RMs and CRMs used in atomic spectrometry or in other analytical techniques where aqueous standard solutions are required (usually called RMs or CRMs for spectrometry) is given. The experience of the INM in preparation and certification of such materials is described. Some aspects regarding their use for ensuring the accuracy and for confirmation of the traceability of analytical measurements, especially through calibration and metrological validation of main instrument performances, are discussed.  相似文献   

17.
Certified reference materials (CRMs) are used in analytical chemistry for method validation studies in order to establish measurement accuracy, traceability, and long-term stability throughout repeated analyses. Quality control (QC) during routine analysis requires access to stable materials appropriate for the sample matrix being analyzed. However, it may be difficult to find representative, low-cost QC materials, especially for specific analytes in biological tissue matrices. Here, four caprine liver pools are prepared for use as internal QC materials for trace element measurements in biological tissue. Analytes of interest include essential and nonessential trace elements and the lanthanide series elements. The suitability of caprine liver to serve as a secondary reference material (RM), as well as for routine QC purposes, is demonstrated through homogeneity and stability measurements, and the acquisition of precision and uncertainty data. Traceability is established for selected analytes for which available CRMs can provide an unbroken chain of calibrations.  相似文献   

18.
A rapid procedure, based on closed vessels microwave digestion and inductively coupled plasma-mass spectrometry (ICP-MS), was evaluated to ascertain the effect of chronic exposure to cadmium on intracellular accumulation of minor and essential trace elements in cultured epithelial cells (Caco-2 TC7). For all measurements, the method of external calibration was used and 3 elements (Be, Sc, In) were selected as internal standards. Optimization procedures are discussed and results are presented for the total determination of 9 key analytes (Na, Mg, Ca, Cr, Mn, Cu, Zn, Mo, and Cd) in certified reference materials (CRMs) and 20 samples of Caco-2 TC7 cells long-term exposed to Cd. The performance characteristics of the analytical system were evaluated by calibration and linearity, limits of detection and quantitation, accuracy with spiking, trueness and repeatability with available CRMs. As a complement to the ICP-MS determinations, both available CRMs and cell samples were analyzed either by electro thermal- or flame atomic absorption spectrometry. The results were in good agreement with the ICP-MS results.  相似文献   

19.
研制了按Si,Fe,Cu,Mg,Mn,Zn,Sn,Pb,Ni,Ti,Cr,Sr,Ga,Zr,Be,Sb 16种元素技术指标呈系列化分布的3系铸造铝合金光谱与化学分析用标准样品。采用500 kg中频感应炉冶炼、连续铸造、均热挤压工艺,确保了标准样品的均匀性。多家权威实验室用准确可靠的分析方法确定了该16个元素的标准值和不确定度。经考察,该套标准样品除Sb外,15个元素标准曲线的线性关系均良好,线性相关系数均在99%以上。用直线拟合法于4年内对标准样品的稳定性考察5次,结果表明4年内其稳定性良好。该系列标准样品填补了国内外同类标准样品的空白,已被国家检验检疫总局和国家标准化管理委员会批准为国家级标准样品。  相似文献   

20.
Starting with explanations for the increasing demand for speciation analysis the need of appropriate certified reference materials is justified. Specific aspects of biological reference materials for speciation QA/QC are discussed from the point of view of the total analytical process. Examples of unwanted species transformations during analysis are given and critical analytical steps are highlighted. Unchanged biological materials as CRMs and appropriate pure standard compounds are indispensable for the further development of this analytical field.  相似文献   