首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for the quantitative imaging of Fe, Cu and Zn in cryostat sections of human eye lenses and for depth profiling analysis in bovine lenses. To ensure a tight temperature control throughout the experiments, a new Peltier-cooled laser ablation cell was employed. For quantification purposes, matrix-matched laboratory standards were prepared from a pool of human lenses from eye donors and spiked with standard solutions containing different concentrations of natural abundance Fe, Cu and Zn. A normalisation strategy was also carried out to correct matrix effects, lack of tissue homogeneity and/or instrumental drifts using a thin gold film deposited on the sample surface. Quantitative images of cryo-sections of human eye lenses analysed by LA-ICP-MS revealed a homogeneous distribution of Fe, Cu and Zn in the nuclear region and a slight increase in Fe concentration in the outer cell layer (i.e. lens epithelium) at the anterior pole. These results were assessed also by isotope dilution mass spectrometry, and Fe, Cu and Zn concentrations determined by ID-ICP-MS in digested samples of lenses and lens capsules.
Figure
Depth profiling analysis and quantitative imaging analyses of Fe, Cu and Zn in eye lens sections by LA-ICP-MS using matrix-matched laboratory standards for external calibration and 197Au+ as internal standard  相似文献   

2.
A rapid determination method is presented for gold (Au3+) and platinum (Pt4+) in tissues using matrix-assisted laser desorption ionization quadrupole time-of-flight mass spectrometry (MALDI-Q-TOF-MS). Au and Pt ions in wet-ashed tissue solution were reacted with diethyldithiocarbamate (DDC), and the resulting chelate complex ions Au(DDC)2 + and Pt(DDC)3 + were detected by MALDI-Q-TOF-MS using α-cyano-4-hydroxycinnamic acid as a matrix. The limit of detection (LOD) was 0.8 ng/g tissue and the quantification range was 2–400 ng/g for Au, and the LOD was 6 ng/g tissue and the quantification range was 20–4,000 ng/g for Pt. The Pt levels detected by MALDI-Q-TOF-MS in several tissues of a patient overdosed with cisplatin were nearly the same as those detected by flow-injection electrospray ionization mass spectrometry. The LODs of Au and Pt were 0.04 pg per well (sample spot) and 0.3 pg per well, respectively. To our knowledge, this is the first attempt to quantify Au3+ and Pt4+ ions in tissues by MALDI-Q-TOF-MS.
A rapid determination method is presented for gold and platinum in tissues using matrix-assisted laser desorption ionization quadrupole time-of-flight mass spectrometry (MALDI-Q-TOF-MS). Au and Pt ions in wet-ashed tissue solution were reacted with diethyldithiocarbamate (DDC), and the resulted chelate complex ions Au(DDC)2 + and Pt(DDC)3 + were detected using α-cyano-4-hydroxycinnamic acid as a matrix.  相似文献   

3.
In X-ray photoelectron spectroscopy (XPS) Ar+ ion sputtering is usually used for depth profiling. However, for such samples as organic coatings, this is not feasible because of degradation. Also, measurement of a depth profile on a conventionally prepared cross-section is not possible if, for example, sample thickness is below the smallest available measurement spot size of the XPS system. In our approach we used a rotary microtome to cut samples under a shallow tilting angle of 0.5° to obtain an extended cross-section suitable for XPS investigations. We also used liquid nitrogen cooling to ensure an exposed area of higher quality: topography measurements with a novel optical 3D microscope and by atomic force microscopy revealed the linearity of the inclined sections. With our cryo ultra-low-angle microtomy (cryo-ULAM) preparation technique we were able to determine, by XPS, elemental and chemical gradients within a 25 μm thick polyester-based organic coating deposited on steel. The gradients were related to, for example, depletion of the crosslinking agent in the sub-surface region. Complementary reflection electron energy-loss spectroscopy measurements performed on the cryo-ULAM sections also support the findings obtained from the XPS depth profiles.
Figure
Top view of the sample as imaged in 3D by FF-OCM is shown in a). In b) a side view of the 3D sample structure simultaneously exhibiting the coating surface and substrate-coating interface is depicted. Compositional XPS-depth profile of the coating prepared by cryo-ULAM is shown in c)  相似文献   

4.
Cardiovascular diseases are the world’s number one cause of death, accounting for 17.1 million deaths a year. New high-resolution molecular and structural imaging strategies are needed to understand underlying pathophysiological mechanism. The aim of our study is (1) to provide a molecular basis of the heart animal model through the local identification of biomolecules by mass spectrometry imaging (MSI) (three-dimensional (3D) molecular reconstruction), (2) to perform a cross-species validation of secondary ion mass spectrometry (SIMS)-based cardiovascular molecular imaging, and (3) to demonstrate potential clinical relevance by the application of this innovative methodology to human heart specimens. We investigated a MSI approach using SIMS on the major areas of a rat and mouse heart: the pericardium, the myocardium, the endocardium, valves, and the great vessels. While several structures of the heart can be observed in individual two-dimensional sections analyzed by metal-assisted SIMS imaging, a full view of these structures in the total heart volume can be achieved only through the construction of the 3D heart model. The images of 3D reconstruction of the rat heart show a highly complementary localization between Na+, K+, and two ions at m/z 145 and 667. Principal component analysis of the MSI data clearly identified different morphology of the heart by their distinct correlated molecular signatures. The results reported here represent the first 3D molecular reconstruction of rat heart by SIMS imaging.
Figure
Workflow of the 3D reconstruction. A Tissue section, B gold deposition is done by sputter coating, C, C1 SIMS-ToF mass analyzer, C, C2 mass spectral peaks, C, C3 datacube images; D, E Reconstruction of the heart showing 3D-spatial distributions of three different ions 145 m/z (red), 23 m/z (green), and 39 m/z (blue); F coregistration of 40 individual MS imaging  相似文献   

5.
Elemental composition assignment confidence in mass spectrometry is typically assessed by monoisotopic mass accuracy. For a given mass accuracy, resolution and detection of other isotopologues can further narrow the number of possible elemental compositions. However, such measurements require ultrahigh resolving power and high dynamic range, particularly for compounds containing low numbers of nitrogen and oxygen (both 15N and 18O occur at less than 0.4 % natural abundance). Here, we demonstrate validation of molecular formula assignment from isotopic fine structure, based on ultrahigh resolution broadband Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Dynamic range is enhanced by external quadrupole and internal stored waveform inverse Fourier transform (SWIFT) isolation to facilitate detection of low abundance heavy atom isotopologues.
Figure
?  相似文献   

6.
This work shows the analytical potential of inductively coupled plasma orthogonal-acceleration time-of-flight mass spectrometry (ICP-OA-TOF-MS) for rapid, simultaneous, and reliable determination of more than 50 elements at ultra-trace levels in urine. Under optimum instrumental conditions, after a 10-fold sample dilution step, and by using Rh as an internal standard, ICP-OA-TOF-MS also enables the determination of elements whose assay is more diffcult when using conventional quadrupole instruments. This is confirmed by the analysis of commercially available reference urine samples and/or by analytical recoveries study and isotope ratio based determination of accuracies. On the other side, the interference resulting from polyatomic carbon, chlorine, or various sulfur species does not allow the determination of elements such as Cr, Fe, V, Se and As without a mathematical correction.
Figure
Part of the ICP-TOF-MS mass spectra recorded from SeronormTM Trace Elements Urine Lot 0511545 diluted in 1+9 ratio with water  相似文献   

7.
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging of biological tissue sections using a layer of deposited ice as an energy-absorbing matrix was investigated. Dynamics of plume ablation were first explored using a nanosecond exposure shadowgraphy system designed to simultaneously collect pictures of the plume with a camera and collect the Fourier transform ion cyclotron resonance FT-ICR mass spectrum corresponding to that same ablation event. Ablation of fresh tissue analyzed with and without using ice as a matrix were compared using this technique. Effect of spot-to-spot distance, number of laser shots per pixel, and tissue condition (matrix) on ion abundance were also investigated for 50 μm-thick tissue sections. Finally, the statistical method called design of experiments was used to compare source parameters and determine the optimal conditions for IR-MALDESI of tissue sections using deposited ice as a matrix. With a better understanding of the fundamentals of ablation dynamics and a systematic approach to explore the experimental space, it was possible to improve ion abundance by nearly one order of magnitude.
Figure
?  相似文献   

8.
The molecular imaging of paper cross sections containing the wet-strength additive poly(amidoamine)–epichlorohydrin (PAE) was effected by Fourier transform infrared (FT-IR) spectroscopic imaging. Thin cross sections of laboratory sheet samples were prepared and transferred onto CaF2 substrates. A laboratory sheet sample without PAE acted as a reference. Principal component analysis (PCA) was applied to identify and to reveal the distribution of PAE across the section. Differences in the loading plots of the fourth and fifth principal components for the sheets with and without PAE were found in the region of the amide I, amide II, and amine bands within a variance of 0.4–0.8 %. The score images of the PCA reveal inhomogeneous distribution of PAE. Small areas of higher concentration of PAE occur across the cross section. The aim of this study was to demonstrate that FT-IR spectroscopic imaging provides spatially resolved quantitative information about the chemical composition of paper, which was successfully achieved.
Figure
New analytical approach for imaging paper cross sections at molecular level  相似文献   

9.
The fragmentations of [AA + M]+ complexes, where AA = Phe, Tyr, Trp, or His, and M is a monovalent metal (Li, Na, or Ag), have been exhaustively studied through collision-induced dissociation (CID) and through deuterium labeling. Dissociations of the Li- and Ag-containing complexes gave a large number of fragment ions; by contrast, the sodium/amino acid complexes have lower binding energies, and dissociation resulted in much simpler spectra, with loss of the entire ligand dominating. Unambiguous assignments of these fragment ions were made and formation mechanisms are proposed. Of particular interest are fragmentations in which the charge was retained on the organic fragment and the metal was lost, either as a metal hydride (AgH) or hydroxide (LiOH) or as the silver atom (Ag?).
Caption for Graphical Abstract
CID products of Li+, Na+, and Ag+ complexes of Phe, Tyr, Trp, and His are reported and mechanisms by which they are formed are proposed.  相似文献   

10.
The fragmentation reactions of the MH+ ions of Leu-enkephalin amide and a variety of heptapeptide amides have been studied in detail as a function of collision energy using a QqToF beam type mass spectrometer. The initial fragmentation of the protonated amides involves primarily formation of bn ions, including significant loss of NH3 from the MH+ ions. Further fragmentation of these bn ions occurs following macrocyclization/ring opening leading in many cases to bn ions with permuted sequences and, thus, to formation of non-direct sequence ions. The importance of these non-direct sequence ions increases markedly with increasing collision energy, making peptide sequence determination difficult, if not impossible, at higher collision energies.
Figure
?  相似文献   

11.
Ionic liquids have attracted much attention in the analysis of a variety of species. The functional groups in ionic liquids can result in highly efficient separation and enrichment and, because of their typical lack of volatility, they are environmentally benign. We grafted imidazole cations onto the surface of chloromethyl polystyrene, denoted PS-CH2-[MIM]+Cl?, and this modified polymer was used to selectively extract the protein hemoglobin (Hb). The prepared extractant PS-CH2-[MIM]+Cl?, containing 2 mmol immobilized imidazole groups per gram polymer, was characterized by FT-IR, surface charge analysis, and elemental analysis. The adsorption efficiency was 91 %. The adsorption capacity of the PS-CH2-[MIM]+Cl? for Hb was 23.6 μg mg?1, and 80 % of the retained Hb could be readily recovered by use of 0.5 % (m/v) aqueous sodium dodecyl sulfate (SDS) solution as eluate. The activity of the eluted Hb was approximately 90 %. The prepared imidazole-containing solid phase polymer was used for direct adsorption of Hb without use of any other solid matrix as support of the ionic liquid. The material was used in practice to isolate Hb from human whole blood.
Figure
Coordination interaction between heme of hemoglobin and imidazolium-modified chloromethyl polystyrene.  相似文献   

12.
Mass spectrometric imaging (MSI) in combination with electrospray mass spectrometry (ESI-MS) is a powerful technique for visualization and identification of a variety of different biomolecules directly from thin tissue sections. As commonly used tools for molecular reporting, fluorescent proteins are molecular reporter tools that have enabled the elucidation of a multitude of biological pathways and processes. To combine these two approaches, we have performed targeted MS analysis and MALDI-MSI visualization of a tandem dimer (td)Tomato red fluorescent protein, which was expressed exclusively in the hypoxic regions of a breast tumor xenograft model. For the first time, a fluorescent protein has been visualized by both optical microscopy and MALDI-MSI. Visualization of tdTomato by MALDI-MSI directly from breast tumor tissue sections will allow us to simultaneously detect and subsequently identify novel molecules present in hypoxic regions of the tumor. MS and MALDI-MSI of fluorescent proteins, as exemplified in our study, is useful for studies in which the advantages of MS and MSI will benefit from the combination with molecular approaches that use fluorescent proteins as reporters.
Figure
  相似文献   

13.
Optical absorption spectra of cobalt cluster ions, Co n + , and vanadium cluster ions, V n + , were analyzed by a theoretical calculation based on the spin-polarized DV- method, and their electronic and geometric structures were obtained. Relative absorption cross section associated with each electronic transition was calculated; the calculation enables a qualitative comparison of calculated spectrum with a measured one not only in its transition energy but also in its intensity profile. This analysis shows that Co 4 + , Co 3 + , and V 4 + have, respectively, a tetrahedral structure with a bond distance of 2.00Å, an equilateral triangle with a bond distance of 2.30Å, and a distorted tetrahedral structure with five bonds having a distance of 2.34 Å and one of 2.89Å. The differences in the population between majority and minority spins (spin-difference) evaluated from the electronic structure thus obtained were 2.0, 1.7, and zero per atom in Co 3 + , Co 4 + , and V 4 + , respectively. These spin differences indicate a ferromagnetic and an antiferromagnetic spin-coupling in the cobalt and vanadium cluster ions, respectively.  相似文献   

14.
Podoplanin (PDP) is a small transmembrane protein and widely present in various specialized cells throughout the human body. It is a specific marker for identification of lymphatic vessel and a candidate marker for cancer stem cells in squamous cell carcinoma of the lung. We report on method for the highly selective determination of PDP by using a surface plasmon resonance imaging (SPRI) that exploits the highly selective interaction between PDP and anti-human PDP monoclonal antibody (IgG). The sensor has a dynamic range between 0.25 and 1.0?ng?mL?1, and a detection limit of 15?pg?mL?1. It was applied to the determination of PDP in blood plasma and tissue homogenates from paired normal and lung tumor tissue.
Figure
A novel method for the highly selective determination of podoplanin by using a Surface Plasmon Resonance Imaging (SPRI) technique has been developed. For sensor development, highly selective interaction between podoplanin and anti-human podoplanin monoclonal antibody (IgG) was applied.  相似文献   

15.
[M + Ag]+ ions from cyclic and linear polystyrenes and polybutadienes, formed by matrix-assisted laser desorption ionization (MALDI), give rise to significantly different fragmentation patterns in tandem mass spectrometry (MS2) experiments. In both cases, fragmentation starts with homolytic cleavage at the weakest bond, usually a C–C bond, to generate two radicals. From linear structures, the separated radicals depolymerize extensively by monomer losses and backbiting rearrangements, leading to low-mass radical ions and much less abundant medium- and high-mass closed-shell fragments that contain one of the original end groups, along with internal fragments. With cyclic structures, depolymerization is less efficient, as it can readily be terminated by intramolecular H-atom transfer between the still interconnected radical sites (disproportionation). These differences in fragmentation reactivity result in substantially different fragment ion distributions in the MS2 spectra. Simple inspection of the relative intensities of low- versus high-mass fragments permits conclusive determination of the macromolecular architecture, while full spectral interpretation reveals the individual end groups of linear polymers or the identity of the linker used to form the cyclic polymer.
Figure
Macrocyclic and linear polystyrene and polydiene architectures are conclusively distinguished by the MS2 fragmentation patterns of Ag+-cationized oligomers.  相似文献   

16.
An atmospheric pressure laser desorption/ionization mass spectrometry imaging ion source has been developed that combines high spatial resolution and high mass resolution for the in situ analysis of biological tissue. The system is based on an infrared laser system working at 2.94 to 3.10 μm wavelength, employing a Nd:YAG laser-pumped optical parametrical oscillator. A Raman-shifted Nd:YAG laser system was also tested as an alternative irradiation source. A dedicated optical setup was used to focus the laser beam, coaxially with the ion optical axis and normal to the sample surface, to a spot size of 30 μm in diameter. No additional matrix was needed for laser desorption/ionization. A cooling stage was developed to reduce evaporation of physiological cell water. Ions were formed under atmospheric pressure and transferred by an extended heated capillary into the atmospheric pressure inlet of an orbital trapping mass spectrometer. Various phospholipid compounds were detected, identified, and imaged at a pixel resolution of up to 25 μm from mouse brain tissue sections. Mass accuracies of better than 2 ppm and a mass resolution of 30,000 at m/z?=?400 were achieved for these measurements.
Figure
Infrared laser desorption/ionization mass spectrometry imaging provides for direct analysis of biological tissue with a high spatial resolution of 25 μm  相似文献   

17.
A reagentless d-sorbitol biosensor based on NAD-dependent d-sorbitol dehydrogenase (DSDH) immobilized in a sol–gel carbon nanotubes–poly(methylene green) composite has been developed. It was prepared by durably immobilizing the NAD+ cofactor with DSDH in a sol–gel thin film on the surface of carbon nanotubes functionalized with poly(methylene green). This device enables selective determination of d-sorbitol at 0.2 V with a sensitivity of 8.7?μA?mmol?1?L?cm?2 and a detection limit of 0.11 mmol?L?1. Moreover, this biosensor has excellent operational stability upon continuous use in hydrodynamic conditions.
Figure
Reagentless D-sorbitol biosensor based on NAD-dependent D-sorbitol dehydrogenase (DSDH) immobilized in sol-gel/carbon nanotubes/poly(methylene green) composite  相似文献   

18.
From extraction experiments and $ \gamma $ -activity measurements, the extraction constants corresponding to the general equilibrium Eu3+(aq) + 3 A?(aq) + L(nb) $ \Leftrightarrow $ EuL3+(nb) + 3A?(nb) taking place in the two-phase water–nitrobenzene system ( $ {\text{A}}^{ - } = {\text{CF}}_{ 3} {\text{SO}}_{3}^{ - } $ ; L = electroneutral receptors denoted by 1, 2, and 3 – see Scheme 1; aq = aqueous phase, nb = nitrobenzene phase) were evaluated. Further, the stability constants of the EuL3+ complexes in nitrobenzene saturated with water were calculated; they were found to increase in the series of 3 < 2 < 1.
Scheme 1
Structural formulas of N,N,N′,N′,N″,N″-hexacyclohexyl-4,4′,4″-propylidynetris(3-oxabutyramide) (1), bis[(12-crown-4)methyl] dodecylmethylmalonate (2), and bis[(benzo-15-crown-5)-4′-ylmethyl] pimelate (3)  相似文献   

19.
We report on a novel method for the determination of silver ion (Ag+) and cysteine (Cys) by using the probe SYBR Green I (SGI) and an Ag+-specific cytosine-rich oligonucleotide (C-DNA). The fluorescence of SGI is very weak in the absence or presence of randomly coiled C-DNA. If, however, C-DNA interacts with Ag+ through the formation of cytosine-Ag+-cytosine (C-Ag+-C) base pairs, the randomly coiled C-DNA undergoes a structural changes to form a hairpin-like structure, thereby increasing the fluorescence of SGI. This fluorescence turn-on process allows the detection of Ag+ in the 10–600?nM concentration range, with a detection limit of 4.3?nM. Upon the reaction of Ag+ with Cys, Cys specifically removes Ag+ from the C-Ag+-C base pairs and destroys the hairpin-like structure. This, in turn, results in a decrease in fluorescence intensity. This fluorescence turn-off process enables the determination of Cys in the 8–550?nM concentration range, with a detection limit of 4.5?nM. The method reported here for the determination of either Ag+ or Cys is simple, sensitive, and affordable, and may be applied to other detection systems if appropriately selected DNA sequences are available.
Figure
Sencitive and selective detection of Ag+ and cysteine based on fluorescence change of SYBR Green I  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号