首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
We report in-situ production and detection of intermediates at graphenic surfaces, especially during alcohol oxidation. Alcohol oxidation to acid occurs on graphene oxide-coated paper surface, driven by an electrical potential, in a paper spray mass spectrometry experiment. As paper spray ionization is a fast process and the time scale matches with the reaction time scale, we were able to detect the intermediate, acetal. This is the first observation of acetal formed in surface oxidation. The process is not limited to alcohols and the reaction has been extended to aldehydes, amines, phosphenes, sugars, etc., where reaction products were detected instantaneously. By combining surface reactions with ambient ionization and mass spectrometry, we show that new insights into chemical reactions become feasible. We suggest that several other chemical transformations may be studied this way. This work opens up a new pathway for different industrially and energetically important reactions using different metal catalysts and modified substrate.
Figure
?  相似文献   

2.
This work shows the analytical potential of inductively coupled plasma orthogonal-acceleration time-of-flight mass spectrometry (ICP-OA-TOF-MS) for rapid, simultaneous, and reliable determination of more than 50 elements at ultra-trace levels in urine. Under optimum instrumental conditions, after a 10-fold sample dilution step, and by using Rh as an internal standard, ICP-OA-TOF-MS also enables the determination of elements whose assay is more diffcult when using conventional quadrupole instruments. This is confirmed by the analysis of commercially available reference urine samples and/or by analytical recoveries study and isotope ratio based determination of accuracies. On the other side, the interference resulting from polyatomic carbon, chlorine, or various sulfur species does not allow the determination of elements such as Cr, Fe, V, Se and As without a mathematical correction.
Figure
Part of the ICP-TOF-MS mass spectra recorded from SeronormTM Trace Elements Urine Lot 0511545 diluted in 1+9 ratio with water  相似文献   

3.
The mechanism of arsenic toxicity still remains unclear, although enzymatic inhibition, impaired antioxidants metabolism and oxidative stress may play a role. The toxicological effects of trivalent inorganic arsenic on laboratory mouse Mus musculus after oral administration (3 mg/kg body weight/day) were investigated along 12 days, using a metabolomic approach based on direct infusion mass spectrometry to polar and lipophilic extracts from different organs and fluids (liver, kidney, and plasma). Positive and negative acquisition modes (ESI+/ESI?) were used throughout the experiments. The most significant endogenous metabolites affected by exposure were traced by partial least square-discriminant analysis and confirmed by tandem mass spectrometry (MS/MS) and gas chromatography coupled to MS. In this work, the toxic effect of arsenic has been related with important metabolic pathways, such as energy metabolism (e.g., glycolysis, Krebs cycle), amino acids metabolism, choline metabolism, methionine cycle, and degradation of membrane phospholipids (cell apoptosis). In addition, this work illustrates the high reliability of mass spectrometry based on a metabolomic approach to study the biochemical effects induced by metal exposure.
Figure
Metabolomic study in plasma, liver and kidney of mice exposed to inorganic arsenic based on mass spectrometry  相似文献   

4.
Mass spectrometry has emerged as a powerful tool for the bioanalytical sciences because of its ability to characterize small and large biomolecules in vanishingly small amounts. A recurring motif in mass spectrometry aims to decipher the chemical composition of biological samples at the molecular level, requiring drastic improvements in the ability to interrogate well defined and highly spatially resolved areas of a sample surface. With the growth of novel ionization methods, numerous advances have been made in sampling biological tissue surfaces. Here, current advancements in ambient, inlet, and vacuum ionization methods are discussed with respect to the potential improvements in the goal of achieving high spatial resolution and/or fast surface analysis. Of similar importance is the need for improvements in applicable characterization strategies using high performance fragmentation technologies such as electron transfer dissociation and electron capture dissociation directly from surfaces, and gas-phase separation through ion mobility spectrometry and high resolution mass spectrometry.
Figure
?  相似文献   

5.
Electrospray laser desorption ionization mass spectrometry (ELDI/MS) allows the rapid desorption and ionization of proteins from solutions under ambient conditions. In this study, we have demonstrated the use of ELDI/MS to efficiently examine the integrity of the proteins stored in various solutions before they were further used for other biochemical tests. The protein standards were prepared in the solutions containing buffers, organic salts, inorganic salts, strong acid, strong base, and organic solvents, respectively, to simulate those collected from solvent extraction, filtration, dialysis, or chromatographic separation. Other than the deposit of a drop of the sample solution on the metallic sample plate in an ELDI source, no additional sample pretreatment is needed. The sample drop was then irradiated with a pulsed laser; this led to desorption of the analyte molecules, which subsequently entered the ESI plume to undergo post-ionization. Because adjustment of the composition of the sample solution is unnecessary, this technique appears to be useful for rapidly evaluating the integrity of proteins after storage or prior to further biochemical treatment. In addition, when using acid-free and low-organic-solvent ESI solutions for ELDI/MS analysis, the native conformations of the proteins in solution could be detected.
Figure
?  相似文献   

6.
The aim of this study was to evaluate the biological and chemical response of Allium cepa L. exposed to inorganic selenium compounds. Besides the investigation of the total content of selenium as well as its chemical speciation, the Allium test was used to evaluate the growth of onion roots and mitotic activity in the roots’ meristem. The total content of selenium was determined by inductively coupled plasma mass spectrometry (ICP MS). High-performance liquid chromatography (HPLC), coupled to ICP MS, was used for the selenium chemical speciation. Results indicated that A. cepa plants are able to biotransform inorganic selenium compounds into their organic derivatives, e.g., Se-methylselenocysteine from the Se(IV) inorganic precursor. Although the differences in the biotransformation of selenium are due mainly to the oxidation state of selenium, the experiment has also shown a fine effect of counter ions (H+, Na+, NH4 +) on the response of plants and on the specific metabolism of selenium.
Figure
?  相似文献   

7.
Until recently, atmospheric pressure photoionization (APPI) has typically been used for the determination of non-polar halogenated flame retardants (HFRs) by liquid chromatography (LC) tandem mass spectrometry. In this study, we demonstrated the feasibility of utilizing liquid chromatography atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (LC-APCI-MS/MS) for analysis of 38 HFRs. This developed method offered three advantages: simplicity, rapidity, and high sensitivity. Compared with APPI, APCI does not require a UV lamp and a dopant reagent to assist atmospheric pressure ionization. All the isomers and the isobaric compounds were well resolved within 14-min LC separation time. Excellent instrument detection limits (6.1 pg on average with 2.0 μL injection) were observed. The APCI mechanism was also investigated. The method developed has been applied to the screening of wastewater samples for screening purpose, with concentrations determined by LC-APCI-MS/MS agreeing with data obtained via gas chromatography high resolution mass spectrometry.
Figure
LC-APCI-MS/MS for analysis of halogenated flame reterdants  相似文献   

8.
In the environment, the methylation of metal(loid)s is a widespread phenomenon, which enhances both biomobility as well as mostly the toxicity of the precursory metal(loid)s. Different reaction mechanisms have been proposed for arsenic, but not really proven yet. Here, carbon isotope analysis can foster our understanding of these processes, as the extent of the isotopic fractionation allows to differentiate between different types of reaction, such as concerted (SN2) or stepwise nucleophilic substitution (SN1) as well as to determine the origin of the methyl group. However, for the determination of the kinetic isotope effect the initial isotopic value of the transferred methyl group has to be determined. To that end, we used hydroiodic acid for abstraction of the methyl group from methylcobalamin (CH3Cob) or S-adenosyl methionine (SAM) and subsequent analysis of the formed methyl iodide by gas chromatography (GC) isotope ratio mass spectrometry (IRMS). In addition, three further independent methods have been investigated to determine the position-specific δ 13C value of CH3Cob involving photolytic cleavage with different additives or thermolytic cleavage of the methyl-cobalt bonding and subsequent measurement of the formed methane by GC-IRMS. The thermolytic cleavage gave comparable results as the abstraction using HI. In contrast, photolysis led to an isotopic fractionation of about 7 to 9 ‰. Furthermore, we extended a recently developed method for the determination of carbon isotope ratios of organometal(loid)s in complex matrices using hydride generation for volatilization and matrix separation before heart-cut GC and IRMS to the analysis of the low boiling partly methylated arsenicals, which are formed in the course of arsenic methylation. Finally, we demonstrated the applicability of this methodology by investigation of carbon fractionation due to the methyl transfer from CH3Cob to arsenic induced by glutathione.
Position-specific isotope analysis of the methyl group in CH3Cob by abstraction using HI and subsequent analysis of formed CH3I by GC-IRMS  相似文献   

9.
10.
Much progress has been made in identification of the proteins in proteomes, and quantification of these proteins has attracted much interest. In addition to popular tandem mass spectrometric methods based on soft ionization, inductively coupled plasma mass spectrometry (ICPMS), a typical example of mass spectrometry based on hard ionization, usually used for analysis of elements, has unique advantages in absolute quantification of proteins by determination of an element with a definite stoichiometry in a protein or attached to the protein. In this Trends article, we briefly describe state-of-the-art ICPMS-based methods for quantification of proteins, emphasizing protein-labeling and element-tagging strategies developed on the basis of chemically selective reactions and/or biospecific interactions. Recent progress from protein to cell quantification by use of ICPMS is also discussed, and the possibilities and challenges of ICPMS-based protein quantification for universal, selective, or targeted quantification of proteins and cells in a biological sample are also discussed critically. We believe ICPMS-based protein quantification will become ever more important in targeted quantitative proteomics and bioanalysis in the near future.
Online Abstract Figure
ICPMS-based protein and cell quantification  相似文献   

11.
Drug monitoring is usually performed by liquid chromatography coupled with optical detection or electrospray ionization mass spectrometry. More recently, matrix-assisted laser desorption/ionization (MALDI) in combination with triple quadrupole or Fourier-transform (FT) mass analyzers has also been reported to allow accurate quantification. Here, we present a strategy that employs standard MALDI time-of-flight (TOF) mass spectrometry (MS) for the sensitive and accurate quantification of saquinavir from an extract of blood peripheral mononuclear cells. Unambiguous identification of saquinavir in the mass spectra was possible because of using internal mass calibration and by an overall low chemical noise in the low mass range. Exact mass determination of the constant background peaks of the cell extract, which were used for recalibration, was performed by an initial MALDI-FT-MS analysis. Fast and multiplexed sample analysis was enabled by microarray technology, which provided 10 replicates in the lower nL range for each sample in parallel lanes on a chip. In order to validate the method, we employed various statistical tests, such as confidence intervals for linear regressions, three quality control samples, and inverse confidence limits of the estimated concentration ratios.
Figure
?  相似文献   

12.
Trace level analyses in complex matrices benefit from heart-cut multidimensional gas chromatographic (MDGC) separations and quantification via a stable isotope dilution assay. Minimization of the potential transfer of co-eluting matrix compounds from the first dimension (1D) separation into the second dimension separation requests narrow cut-windows. Knowledge about the nature of the isotope effect in the separation of labeled and unlabeled compounds allows choosing conditions resulting in at best a co-elution situation in the 1D separation. Since the isotope effect strongly depends on the interactions of the analytes with the stationary phase, an appropriate separation column polarity is mandatory for an isotopic co-elution. With 3-alkyl-2-methoxypyrazines and an ionic liquid stationary phase as an example, optimization of the MDGC method is demonstrated and critical aspects of narrow cut-window definition are discussed.
Figure
Avoiding chromatographic separation of isotopic standards by fine-tuning the isotope effect allows narrow cut-windows in SIDA based MDGC applications.  相似文献   

13.
14.
Field-flow fractionation (FFF) is a powerful alternative to column-based polymer fractionation methods such as size-exclusion chromatography (SEC) or interaction chromatography (IC). The most common polymer fractionation method, SEC, has its limitations when polymers with very high molar masses or complex structures must be analysed. Another limitation of all column-based methods is that the samples must be filtered before analysis and shear degradation of large macromolecules may be caused by the stationary phase and/or the column frits. Finally, the separation of very polar polymers may be a challenge because such polymers interact very strongly with the stationary phase, causing irreversible adsorption or other negative effects. This article reviews the latest developments in field-flow fractionation of complex polymers. It is demonstrated that some of the limitations of column-based chromatography can be overcome by FFF. When appropriate, results from column-based fractionations are compared with those from FFF fractionations to highlight the specific merits and challenges of each method. In addition to the fractionations themselves, various detector setups are discussed to show that different polymer distributions require different experimental procedures. Examples are given of the analysis of molar mass distribution, chemical composition, and microstructure. Advanced detector combinations are discussed, most prominently the very recently developed coupling to 1H NMR. Finally, analysis of polymer nanocomposites by asymmetric flow field-flow fractionation (AF4)–FTIR is presented.
Figure
FFF fractionation and analysis of a complex polymer using a multidetector setup  相似文献   

15.
The aim of this work is to compare simultaneous isotope dilution analysis of organotin and organomercury compounds by gas chromatography–mass spectrometry (GC–MS) and gas chromatography–inductively coupled plasma mass spectrometry (GC–ICP/MS) on certified bivalve samples. These samples were extracted by microwave with tetramethylammonium hydroxide (TMAH). Derivatization with both NaBEt4 and NaBPr4 was evaluated, and analytical performances were compared. Two CRM materials, BCR-710 and CRM-477, were analyzed by both techniques to verify accuracy. A mixed spike containing 201Hg-enriched methylmercury (MeHg), 199Hg-enriched inorganic mercury (iHg), 119Sn-enriched monobutyltin (MBT), dibutyltin (DBT), and tributyltin (TBT) as well as homemade 116Sn-enriched monophenyltin (MPT), diphenyltin (DPT), and triphenyltin (TPT) was used for the isotope dilution analysis of samples. The two techniques studied were compared in terms of classic analytical parameters: linearity, precision or repeatability (i.e., percent relative standard deviation, RSD%), limit of detection (LOD), and limit of quantification (LOQ), showing excellent linearity, precision below 12 % for all analytes, and LOQs of 0.06–1.45 pg for GC–MS and 0.02–0.27 pg for GC–ICP/MS.
Figure
?  相似文献   

16.
Molecular imprinting technology is an attractive approach of creating recognition sites in polymeric materials by using the templating approach found in many natural systems. These recognition sites have memory to the target molecule that enables selective recognition of the template species. Molecularly imprinted polymers (MIPs) have been used in a wide range of areas including separation and isolation, catalysis, chemical sensing, and drug delivery. This review aims at highlight the recent advances in the application of molecular imprinting technology for inorganic and small organic anion recognition in aqueous media.
Figure
The application of molecular imprinting technology for anion recognition in aqueous media  相似文献   

17.
A new method was developed for the speciation of inorganic arsenic in environmental water by using selective magnetic solid-phase extraction followed by inductively coupled plasma mass spectrometry. It is found that As(V) selectively adsorbed on amino-modified silica-coated magnetic nanoparticles (MNPs) in the pH range from 3 to 8, while As(III) is not be retained. The As(V)-loaded MNPs can be separated easily from the aqueous sample solution by simply applying an external magnetic field. The adsorbed As(V) was quantitatively recovered from the MNPs using using 1 M nitric acid. Total inorganic As was extracted after the permanganate oxidation of As(III) to As(V). Parameters affecting the separation were investigated systematically, and the optimal separation conditions were established. Under the optimal conditions, the limit of detection is 0.21 ng L?1, and the precision is 6.8% (at 10 ng L?1, for n?=?7). The method was applied to the speciation of inorganic arsenic in environmental water of tobacco growing area.
Figure
A new kind of silica-coated magnetic nanoparticles (SCMNPs) modified with AAPTS was synthesized and employed as magnetic solid phase extraction adsorbent for ICP-MS speciation of inorganicAs in environmental water  相似文献   

18.
Multidimensional high-performance liquid chromatography (HPLC) is a key method in shotgun proteomics approaches for analyzing highly complex protein mixtures by complementary chromatographic separation principles. Here, we describe an integrated 3D-nano-HPLC/nano-electrospray ionization quadrupole time-of-flight mass spectrometry system that allows an enzymatic digestion of proteins followed by an enrichment and subsequent separation of the created peptide mixtures. The online 3D-nano-HPLC system is composed of a monolithic trypsin reactor in the first dimension, a monolithic affinity column with immobilized monomeric avidin in the second dimension, and a reversed phase C18 HPLC-Chip in the third dimension that is coupled to a nano-ESI-Q-TOF mass spectrometer. The 3D-LC/MS setup is exemplified for the identification of biotinylated proteins from a simple protein mixture. Additionally, we describe an online 2D-nano-HPLC/nano-ESI-LTQ-Orbitrap-MS/MS setup for the enrichment, separation, and identification of cross-linked, biotinylated species from chemical cross-linking of cytochrome c and a calmodulin/peptide complex using a novel trifunctional cross-linker with two amine-reactive groups and a biotin label.
Figure
Schematic representations of the online 3D-nano-HPLC/nano-ESI-Q-TOF-MS/MS setup; LP loading pump, NP nano-pump  相似文献   

19.
An introduction to the principle and possibilities of the new method of circular dichroism laser mass spectrometry is given and its state of development is reviewed. This method allows enantiosensitive, mass-selective probing of chiral molecules. It is based on the combination of resonance-enhanced multiphoton ionization with circularly polarized light and specially modified time-of-flight mass spectrometry. As an example, application to carbonyls is presented.
Figure
The combination of resonance enhanced multiphoton ionization and circular dichroism performed in a time-of-flight mass spectrometer allows mass selective enantio-sensitive spectroscopy with new features for chiral analysis  相似文献   

20.
Direct inject electrospray mass spectrometry offers minimal sample preparation and a “shotgun” approach to analyzing samples. However, complex matrix effects often make direct inject an undesirable sample introduction technique, particularly for trace level analytes. Highlighted here is our solution to the pitfalls of direct inject mass spectrometry and other ambient ionization methods with a focus on trace explosives. Direct analyte-probed nanoextraction coupled to nanospray ionization mass spectrometry solves selectivity issues and reduces matrix effects while maintaining minimal sample preparation requirements. With appropriate solvent conditions, most explosive residues can be analyzed with this technique regardless of the nature of the substance (i.e., nitroaromatic, oxidizing salt, or peroxide).
Figure
?  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号