首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Tradescantia pallida (Wandering jew)—a succulent perennial herb—was screened to be a potent chromium (Cr) accumulator. Its ability to grow under Cr stress was examined by studying biochemical changes and physiological response of the plant in presence of 5–20 mg L?1 Cr(VI) concentration in hydroponic environment for up to ca. 90 days. Average Cr(VI) bioaccumulation in plant roots reached about 408 μg g?1 dry weight (dw) after 30 days and up to 536 μg g?1dw after 60 days of culture. Biochemical changes in the plant exposed to Cr(VI) indicated a reduction in the total carbohydrate and protein content. Furthermore, lipid peroxidation, catalase, peroxidase and ascorbate peroxidase activity were measured in different parts of the plant exposed to Cr(VI). Increased activities of these enzymes showed their important role in overcoming the Cr-induced oxidative stress on the plant.  相似文献   

2.
The appearance of chromium in the aqueous effluent is a major concern for the modern industry. In this work, Mesorhizobium amorphae strain CCNWGS0123 was investigated as a biosorbent to remove chromium from aqueous solutions. The optimum pH for Cr(III) and Cr(VI) biosorption were 4 and 2, respectively. This isolate showed an experimental maximum Cr(III) adsorption capacity of 53.52 mg?L?1, while the result was 47.67 mg?L?1 for Cr(VI), with an initial 100 mg?L?1 Cr ions and 1.0 g?L?1 biomass. In terms of time equilibrium, Cr(III) ion was more readily adsorbed than Cr(VI) by this isolate. The biosorption data of both ions fit the Langmuir isotherm better than that of Freundlich model. Meanwhile, this organism exhibited a good capability to release Cr ions, with desorption efficiency of 70 % for Cr(III) and 76 % for Cr(VI). Fourier transform infrared spectroscopy analysis showed that –OH, –COO, –NH, amide I, and C=O were involved in Cr(III) and Cr(VI) binding. The biosorbent was further characterized by scanning electron microscopy and energy-dispersive X-ray spectrometry, which indicated an accumulation of chromium on the cellular level. In the binary mixtures, the removal ratio of total Cr and Cr(III) increased from pH?2 to 4. The highest removal ratio of the total Cr was observed in the 25/25 mg?L?1 mixture at pH?4. In addition, the removal efficiency of Cr(VI) was closely influenced by Cr(III) in the mixture, decreasing to 23.57 mg?g?1 in the 100/100 mg?L?1 mixture system, due to the competition of Cr(III). The potential usage of the chromium-resistant rhizobium for the remediation of chromium-contaminated effluents has been demonstrated based on the above results.  相似文献   

3.
A simple, low-cost and sensitive method is demonstrated for derivatization and extraction of iodine from milk samples using hollow fiber liquid-phase microextraction (HF-LPME) and gas chromatography-electron capture detection. Iodide ions are converted to iodine under acidic medium and in the presence of an oxidant. The generated iodine reacted with 3-pentanone in extraction vial to give 2-iodo-3-pentanone and was extracted into 4 μL of 1-octanol located in the lumen of a hollow fiber. Organic solvent was selected using one variable at a time optimization method and the other main factors affecting derivatization and HF-LPME procedures were evaluated using a Taguchi’s L16 (45) orthogonal array. Under optimal conditions, the method showed low limit of detection (0.5 ng mL?1), wide linear range (1–2,000 ng mL?1) with good correlation coefficient (0.9997) and acceptable relative standard deviation (4.6 %, n = 5). Finally, the developed method was successfully applied for determination of iodide in real samples including infant milk formulas and cow milk with reasonable relative recoveries (99.8–110.5 %).  相似文献   

4.
Three bacterial isolates, GT2, GT3, and GT7, were isolated from the sludge and water of a circulating cooling system of iron and steel plant by screening on Cr(VI)-containing plates. Three isolates were characterized as the members of the genus Pseudomonas on the basis of phenotypic characteristics and 16S rRNA sequence analysis. All isolates were capable of resisting multiple antibiotics and heavy metals. GT7 was most resistant to Cr(VI), with a minimum inhibitory concentration (MIC) of 6.5 mmol L?1. GT7 displayed varied rates of Cr(VI) reduction in M2 broth, which was dependent on pH, initial Cr(VI) concentration, and inoculating dose. Total chromium analysis revealed that GT7 could remove a part of chromium from the media, and the maximum rate of chromium removal was up to 40.8 %. The Cr(VI) reductase activity of GT7 was mainly associated with the soluble fraction of cell-free extracts and reached optimum at pH 6.0~8.0. The reductase activity was apparently enhanced by external electron donors and Cu(II), whereas it was seriously inhibited by Hg(II), Cd(II), and Zn(II). The reductase showed a K m of 74 μmol L?1 of Cr(VI) and a V max of 0.86 μmol of Cr(VI) min?1 mg?1 of protein. The results suggested that GT7 could be a promising candidate for in situ bioremediation of Cr(VI).  相似文献   

5.
Ying Gu  Xiashi Zhu 《Mikrochimica acta》2011,173(3-4):433-438
A sensitive and selective method for the speciation of Cr(III) and Cr(VI) in water samples was developed. It is based on the selective binding of the complex formed between Cr(III) and 4-(2-pyridylazo)resorcinol adsorbed on a cross-linked polymer modified with β-cyclodextrin and placed in a micro-column. Graphite furnace atomic absorption spectrometry (GFAAS) was used to quantify chromium. Cr(VI) ion is not adsorbed but remains in the aqueous sample phase. Thus, an in-situ separation of Cr(VI) and Cr(III) is accomplished. The concentration of Cr (VI) was calculated by subtracting the value for Cr(III) from that for total chromium. Under optimum conditions, the limit of detection of Cr(III) is 0.056 μg L?1, and the linear range is from 2.0 to 160.0 μg L?1. The relative standard deviation is 2.5% (n?=?3, at 30.0 μg L?1). The preconcentration factor is 25. The method was applied to the speciation of chromium in water samples, and recoveries in spiked real samples range from 101.9% to 104.5%. A reference water sample (GBW(E)080642) also was analyzed, and the results were in good agreement with the certified values.
Figure
The quantitative adsorption (≥90%) on the β-CDCP for Cr(III) was found in the range of the pH 5.5–6.0, whereas the adsorption efficiency for Cr(VI) at this pH range was rather low.  相似文献   

6.
An electrochemical magneto immunosensor for the detection of low concentrations of paraquat (PQ) in food samples has been developed and its performance evaluated in a complex sample such as potato extracts. The immunosensor presented uses immunoreagents specifically developed for the recognition of paraquat, a magnetic graphite–epoxy composite (m-GEC) electrode and biofunctionalized magnetic micro-particles (PQ1-BSAMP) that allow reduction of the potential interferences caused by the matrix components. The amperometric signal is provided by an enzymatic probe prepared by covalently linking an enzyme to the specific antibodies (Ab198-cc-HRP). The use of hydroquinone, as mediator, allows recording of the signal at a low potential, which also contributes to reducing the background noise potentially caused by the sample matrix. The immunocomplexes formed on top of the modified MP are easily captured by the m-GEC, which acts simultaneously as transducer. PQ can be detected at concentrations as low as 0.18?±?0.09 μg L?1. Combined with an efficient extraction procedure, PQ residues can be directly detected and accurately quantified in potato extracts without additional clean-up or purification steps, with a limit of detection (90 % of the maximum signal) of 2.18?±?2.08 μg kg?1, far below the maximum residue level (20 μg kg?1) established by the EC. The immunosensor presented here is suitable for on-site analysis. Combined with the use of magnetic racks, multiple samples can be run simultaneously in a reasonable time.  相似文献   

7.
An enantioselective liquid chromatographic method using two-phase hollow fiber liquid-phase microextraction (HF-LPME-HPLC) was developed for the determination of isradipine (ISR) enantiomers and its main metabolite (pyridine derivative of isradipine, PDI) in microsomal fractions isolated from rat liver. The analytes were extracted from 1 mL of microsomal medium using a two-phase HF-LPME procedure with hexyl acetate as the acceptor phase, 30 min of extraction, and sample agitation at 1,500 rpm. For the first time, ISR enantiomers and PDI were resolved. For this separation, a Chiralpak® AD column with hexane/2-propanol/ethanol (94:04:02, v/v/v) as the mobile phase at a flow rate of 1.5 mL min?1 was used. The column was kept at 23?±?2 °C. The drug and metabolite detection was performed at 325 nm and the internal standard oxybutynin was detected at 225 nm. The recoveries were 23% for PDI and 19% for each ISR enantiomer. The method presented quantification limits (LOQ) of 50 ng mL?1 and was linear over the concentration range of 50–5,000 and 50–2,500 ng mL?1 for PDI and each ISR enantiomer, respectively. The validated method was employed to an in vitro biotransformation study of ISR using rat liver microsomal fraction showing that (+)-(S)-ISR is preferentially biotransformed.  相似文献   

8.
This work describes a novel polyaniline-magnetite nanocomposite and its application to the preconcentration of Cr(VI) anions. The material was obtained by oxidative polymerization of aniline in the presence of magnetite nanoparticles. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Extraction time, amount of magnetic sorbent and pH value were selected as the main factors affecting sorption. The sorption capacity of the sorbent for Cr(VI) is 54 mg g?1. The type, volume and concentration of the eluents, and the elution time were selected as main factors in the optimization study of the elution step. Following sorption and elution, the Cr(VI) ions were reacted with diphenylcarbazide, and the resulting dye was quantified by HPLC with optical detection at 546 nm. The limit of detection is 0.1 μg L?1, and all the relative standard deviations are <6.3 %. The nanocomposite was successfully applied to the rapid extraction and determination of trace quantities of Cr(VI) ions in spiked water samples. Figure
A schematic procedure of magnetic solid phase extraction  相似文献   

9.
A selective, simple and fast dispersive micro solid phase extraction method using magnetic graphene oxide (GO) as an efficient sorbent has been developed for the extraction, separation and speciation analysis of chromium ions. The method is based on different adsorption behaviour of Cr(VI) and Cr(III) species onto magnetic GO in aqueous solutions which allowed the selective separation and extraction of Cr(VI) in the pH range of 2.0–3.0. The retained Cr(VI) ions by the sorbent were eluted using 0.5 mL of 0.5 mol L?1 nitric acid solution in methanol and determined by ?ame atomic absorption spectrometry. Total chromium content was determined after the oxidation of Cr(III) to Cr(VI) by potassium permanganate. All effective parameters on the performance of the extraction process were thoroughly investigated and optimised. Under the optimised conditions, the method exhibited a linear dynamic range of 0.5–50.0 µg L?1 with a detection limit of 0.1 µg L?1 and pre-concentration factor of 200. The relative standard deviations of 3.8% and 4.6% (n = 8) were obtained at 25.0 µg L?1 level of Cr(VI) for intra- and inter-day analysis, respectively. The method was successfully applied to the speciation and determination of Cr(VI) and Cr(III) in environmental water samples.  相似文献   

10.
The direct electron transfer of glucose oxidase (GOx) was achieved based on the immobilization of CdSe@CdS quantum dots on glassy carbon electrode by multi-wall carbon nanotubes (MWNTs)-chitosan (Chit) film. The immobilized GOx displayed a pair of well-defined and reversible redox peaks with a formal potential (E θ’) of ?0.459 V (versus Ag/AgCl) in 0.1 M pH 7.0 phosphate buffer solution. The apparent heterogeneous electron transfer rate constants (k s) of GOx confined in MWNTs-Chit/CdSe@CdS membrane were evaluated as 1.56 s?1 according to Laviron's equation. The surface concentration (Γ*) of the electroactive GOx in the MWNTs-Chit film was estimated to be (6.52?±?0.01)?×?10?11?mol?cm?2. Meanwhile, the catalytic ability of GOx toward the oxidation of glucose was studied. Its apparent Michaelis–Menten constant for glucose was 0.46?±?0.01 mM, showing a good affinity. The linear range for glucose determination was from 1.6?×?10?4 to 5.6?×?10?3?M with a relatively high sensitivity of 31.13?±?0.02 μA?mM?1?cm?2 and a detection limit of 2.5?×?10?5?M (S/N=3).  相似文献   

11.
An aminopropyl silica gel-immobilized calix[6]arene (C[6]APS) containing both amide and acid moieties was prepared from p-tert-butylcalix[6]arene hexacarboxylate derivative and aminopropyl silica gel in the presence of N,N′-diisopropyl carbodiimide coupling reagent. C[6]APS was used to evaluate the sorption properties of Cr(VI) as a sorbent material. In sorption studies, it was observed that C[6]APS was highly effective at pH 1.5 for Cr(VI). The effect of parameters such as pH, sorbent dosage, contact time, initial Cr(VI) concentration and temperature on Cr(VI) sorption; the sorption isotherms were also studied. Maximum sorption capacity was obtained as 3.1 mg g?1 at pH 1.5 and 25 °C for 1 h and 10.4 mg L?1 initial Cr(VI) concentration. Thermodynamic parameters such as change in free energy, enthalpy, and entropy were also determined. In the isotherm studies, Langmuir and Freundlich isotherm models were applied and it was found that the experimental data confirmed to Freundlich isotherm model, and the batch sorption capacity of C[6]APS was calculated as 37.66 mg g?1.  相似文献   

12.
Silica gel surface was chemically functionalized by reaction the silanol from the silica surface with 3-chloropropyltrimethoxysilane followed by reaction with Sulfasalazine. This new sorbent has been used for the preconcentration of low levels of U(VI) ions from an aqueous phase. Parameters involved in extraction efficiency such as pH, weight of the sorbent, volume of sample and eluent were optimized in batch and column methods prior to determination by spectrophotometry using arsenazo(III) reagent. The results showed that U(VI) ions can be sorbed at pH range of 5.0–6.0 in a minicolumn and quantitative recovery of U(VI) (>98.0?±?1.6%) was achieved by stripping with 2.5 mL of 0.1 mol L?1 HCl. The sorption capacity of the functionalized silica gel was 1.15 mmol g?1 of U(VI). A linear calibration graph was obtained over the concentration range of 0.02–27.0 μg mL?1 with a limit of detection of 1 μg L?1 in treatment with 1000 mL of the U(VI) solution in which the preconcentration factor was as high as 400. The method was employed to the preconcentration of U(VI) ions from spiked ground water and synthetic sea water samples.  相似文献   

13.
Deoxynivalenol (DON), nivalenol (NIV) and zearalenone (ZEN) are toxic secondary metabolites produced by several species of Fusarium fungi. These mycotoxins are often found together in a large variety of cereal-based foods, which are regulated by maximum content levels of DON and ZEN. To date, suitable certified reference materials (CRM) intended for quality control purposes are lacking for these Fusarium mycotoxins. In order to overcome this lack, the first CRM for the determination of DON, NIV and ZEN in naturally contaminated wheat flour (ERM®-BC600) was developed in the framework of a European Reference Materials (ERM®) project. This article describes and discusses the whole process of ERM®-BC600 development, including material preparation, homogeneity and stability studies, and an interlaboratory comparison study for certification. A total of 21 selected expert laboratories from different European countries with documented expertise in the field of mycotoxin analysis took part in the certification study using various gas and liquid chromatographic methods. The certified values and their corresponding expanded uncertainties (k?=?2) were assigned in full compliance with the requirements of ISO Guide 35 and are as follows: 102?±?11 μg?kg?1 for DON, 1000?±?130 μg?kg?1 for NIV and 90?±?8 μg?kg?1 for ZEN.  相似文献   

14.
We report on a graphite electrode onto which polypyrrole was electrodeposited and then doped with chromate ion. This electrode can serve as a Cr(VI)-selective solid-state electrode. Electropolymerization of pyrrole was performed potentiostatically at 0.80?V (vs. SCE) using battery graphite as the working electrode in a solution containing 0.10?M of pyrrole and 20?mM of chromate. A platinum wire was used as an auxiliary electrode. The new electrode displays high selectivity, a very wide dynamic range, a sufficiently fast response time and a good shelf lifetime. It shows a linear Nernstian response over 1.0?×?10?6 to 1.0?×?10?1?M concentration range (with a slope of 26.55?±?0.20?mV per log of concentration). The detection limit is 0.5?μM, and the pH optimum is 7.0.
Figure
A highly selective solid state Cr(VI) ion-selective electrode based on polypyrrole conducting polymer was prepared. The introduced Cr(VI) micro sensor electrode exhibited linear response over a wide working concentration range with a high regression coefficient and a near Nernstian slope. The SEM image of PPy/CrO4 thin film shows unevenly distributed nanoparticles.  相似文献   

15.
Benzoylthiourea derivatives (N,N-diphenyl-N′-(3-methylbenzoyl)thiourea and diphenyl-N′-(4-methylbenzoyl)thiourea) were impregnated onto silica gel. The preconcentration of uranium(VI) from aqueous solution was investigated. Extraction conditions were optimized in batch method prior to determination by uv–visible absorption spectrometry using arsenazo(III). The optimum pH for quantitative adsorption was found as 3–7. Quantitative recovery of uranium (VI) was achieved by stripping with 0.1 mol L?1 HCl. Equilibration time was determined as 30 min for 99% sorption of U(VI). Under optimal conditions, dynamic linear range of for U(VI) was found as 0.25–10 μg mL?1. The relative standard deviation as percentage and detection limit were 5.0% (n = 10) for 10 μg mL?1 U(VI) solution and 8.7 ng mL?1, respectively. The method was employed to the preconcentration of U(VI) ions in soil and tap water samples.  相似文献   

16.
A fast and efficient method has been demonstrated for the trace determination of six important metabolites of synthetic pyrethroids including cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (cis- and trans-Cl2CA), cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (cis-Br2CA), 4-fluoro-3-phenoxybenzoic acid (4-F-3-PBA), 3-phenoxybenzoic acid (3-PBA), and 2-phenoxybenzoic acid (2-PBA) in environmental water samples using hollow fiber (HF)-mediated liquid-phase microextraction (LPME) coupled with in-syringe derivatization (ISD) followed by gas chromatography (GC) with electron capture detector (ECD) analysis. This method utilizes a HF membrane segment impregnated with extraction solvent as the LPME sampling probe, which was connected to a microsyringe pre-filled with derivatizing agents, and it was immersed into sample solution for extraction. After extraction, the extracting solution was subjected to derivatization reaction that was performed inside the syringe barrel followed by GC-ECD analysis. Under optimal conditions, the best extraction efficiency was obtained using sampling probe (2.0 cm hollow fiber) impregnated with 1-octanol immersed into water sample (5.0 mL, adjusted pH below 1.0) and stirring (1,250 rpm) for 10 min at 70 °C and diisopropylcarbodiimide (2 μL) and 1,1,1,3,3,3-hexafluoro-2-propanol (1 μL) were the derivatizing agents used. The detection limits of 3 ng mL?1 for cis- and trans-Cl2CA, 2 ng mL?1 for cis-Br2CA, 6 ng mL?1 for 4-F-3-PBA, and 0.6 ng mL?1 for 3-PBA and 2-PBA. The method showed good linearity (R 2 = 0.973?0.998), repeatability from 4.0 to 13 % (n = 5), recovery from 79.2 to 95.7 %, and enrichment factors ranged between 109 and 159 for target analytes spiked in water samples. The proposed method and conventional methods were compared. Results suggested that the proposed HF-LPME-ISD/GC-ECD method was a rapid, simple, inexpensive, and eco-friendly technique for the analysis of metabolites of pyrethroids.  相似文献   

17.
Microcolumn packed single-walled carbon nanotubes (SWCNTs) were used as solid phase extraction adsorbent for chromium speciation coupled to inductively coupled plasma mass spectrometry for detection. The effects of the experimental parameters, including pH of the solution, sample flow rate, volume and concentration of eluent, sample volume and interfering ions, on separation and determination of Cr(III) and Cr(VI) were investigated in detail. It was found that Cr(III) was selectively sorbed on the microcolumn packed with SWCNTs in the pH range from 2.0 to 4.0, while Cr(VI) remained in solution. The retained Cr(III) was subsequently eluted with 2.0 mL of 1.2 mol L?1 nitric acid. Under the optimum conditions, the detection limits based on 3σ criterion were 0.01 ng mL?1 and 0.024 ng mL?1 for Cr(III) and Cr(VI), respectively. The relative standard deviations were less than 5.0% (n?=?9, c?=?1.0 ng mL?1). The method was successfully applied to the speciation of chromium in real samples including natural and waste water. The recoveries of spiked samples were higher than 92.5%.  相似文献   

18.
Fungi have been used for medicinal purposes for long time by Asian countries, being a putative source of powerful new phytopharmaceuticals such as polysaccharides. The aim of this study was to extract endopolysaccharides (IPS) from Ganoderma resinaceum, Phlebia rufa, and Trametes versicolor, grown under submerged culture, to compare crude IPS production, total carbohydrate, and protein yield, and to study the effect of these IPS on HepG2 cells proliferation rate. Total biomass produced by G. resinaceum, P. rufa, and T. versicolor was (in gram per liter) 3.32?±?0.80, 5.42?±?0.58, and 4.2?±?1.29 and the IPS yield (as the biomass percent) was 9.9?±?0.05, 29.0?±?6.3, and 9.1?±?3.1 %, respectively. Characterization of IPS has shown different proportion between total sugar and protein being, on average 6.04, 10.74, and 22.62, for G. resinaceum, T. versicolor, and P. rufa, respectively. The IPS effect, at 50, 100, and 200 μg?mL?1 on HepG2 cell growth and viability was negligible for G. resinaceum and P. rufa but, in the case of T. versicolor, 200 μg?mL?1 of IPS evoked 40 % reduction on cell growth. The results suggest that the intracellular polysaccharides from T. versicolor are a potential source for bioactive molecules with anti-proliferative properties.  相似文献   

19.
Human saliva quantitative monitoring of clarithromycin (CLA) by chemiluminescence (CL) with flow injection analysis was proposed for the first time, which was based on the quenching effect of CLA on luminol–bovine serum albumin (BSA) CL system with a linear range from 7.5?×?10?4 to 2.0 ng/ml. This proposed approach, offering a maximum sample throughput of 100 h?1, was successfully applied to the quantitative monitoring of CLA levels in human saliva during 24 h after a single oral dose of 250 mg intake, with recoveries of 95.2~109.0 % and relative standard deviations lower than 6.5 % (N?=?7). Results showed that CLA reached maximum concentration of 2.28?±?0.02 μg/ml at approximately 3 h, and the total elimination ratio was 99.6 % in 24 h. The pharmacokinetic parameters including absorption rate constant (0.058?±?0.006 h?1), elimination rate constant (0.149?±?0.009 h?1) and elimination half-life time (4.66?±?0.08 h) were obtained. A comparison of human saliva and urine monitoring was also given. The mechanism study of BSA–CLA interaction revealed the binding of CLA to BSA is an entropy driven and spontaneous process through hydrophobic interaction, with binding constant K BSA–CLA of 4.78?×?106 l/mol and the number of binding sites n of 0.82 by flow injection–chemiluminescence model. Molecular docking analysis further showed CLA might be in subdomain IIA of BSA, with K BSA–CLA of 6.82?×?105 l/mol and ΔG of ?33.28 kJ/mol.  相似文献   

20.
This study compared the effectiveness of different biosorbents, viz. materials commonly present in natural treatment systems (Scenedesmus quadricauda and reed) and commonly produced fruit wastes (orange and banana peel) to remove Cr(III) and Cr(VI) from a synthetic wastewater simulating tannery wastewater. The Cr(III) removal efficiency followed the order S. quadricauda?>?orange peel?>?banana peel?>?reed, whereas the Cr(VI) removal followed the order banana peel?>?S. quadricauda?>?reed?>?orange peel. The chromium biosorption kinetics were governed by the intraparticle diffusion mechanism. Isotherm data obtained using the different biosorbents were fitted to the Langmuir, Freundlich, and SIPS models, revealing that the experimental data followed most closely the monolayer sorption theory-based Langmuir model than the other models. The maximum Cr(III) sorption capacity, calculated using the Langmuir model, was found to be 12 and 9 mg/g for S. quadricauda and orange peel, respectively, and the maximum Cr(VI) sorption capacity calculated for banana peel was 3 mg/g. The influence of biosorbent size, pH, solid–liquid ratio, and competing ions were examined for Cr(III) biosorption by S. quadricauda and orange peel and for Cr(VI) sorption by banana peel. The solution pH was found to be the most influential parameter affecting the biosorption process: whereas pH 5 was found to be optimum for maximum removal of Cr(III), Cr(VI) was best removed at a pH as low as 3. Interference to chromium sorption by various ions revealed that Cr(III) binding onto orange peel occurs through electrostatic forces, whereas Cr(VI) binding onto banana peel through non-electrostatic forces.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号