首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %–92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.
Figure
?  相似文献   

2.
Dried blood spots offer many advantages as a sample format including ease and safety of transport and handling. To date, the majority of mass spectrometry analyses of dried blood spots have focused on small molecules or hemoglobin. However, dried blood spots are a potentially rich source of protein biomarkers, an area that has been overlooked. To address this issue, we have applied an untargeted bottom-up proteomics approach to the analysis of dried blood spots. We present an automated and integrated method for extraction of endogenous proteins from the surface of dried blood spots and sample preparation via trypsin digestion by use of the Advion Biosciences Triversa Nanomate robotic platform. Liquid chromatography tandem mass spectrometry of the resulting digests enabled identification of 120 proteins from a single dried blood spot. The proteins identified cross a concentration range of four orders of magnitude. The method is evaluated and the results discussed in terms of the proteins identified and their potential use as biomarkers in screening programs.
Figure
?  相似文献   

3.
苯丙酮尿症(PKU)是新生儿先天性苯丙氨酸羟化酶缺陷所引起的苯丙氨酸代谢障碍疾病.本研究采用超高效液相色谱-质谱联用技术, 测定了5例PKU新生儿出生3天和出生30天后的血斑与20例年龄相仿的正常新生儿血斑中辅酶Q10的绝对含量和辅酶Q9的相对含量,其中,健康新生儿血斑中辅酶Q10的含量为(122.1±24.9) ng/mL,PKU新生儿组的含量为(59.0±12.0) ng/mL.采用气相色谱-质谱联用技术测定了胆固醇和葡萄糖的相对含量.研究结果表明,与对照组相比,PKU新生儿血斑中辅酶Q10、Q9、胆固醇和葡萄糖的含量均显著降低,辅酶Q10的降低与血斑中苯丙氨酸含量升高呈现显著反向相关.本研究结果为PKU患儿的饮食治疗方案提供了依据.  相似文献   

4.
Large polarizable n-alkanes (approximately C18 and larger), alcohols, and other nonpolar compounds can be detected as negative ions when sample solutions are injected directly into the sampling orifice of the atmospheric pressure interface of the time-of-flight mass spectrometer with the direct analysis in real time (DART) ion source operating in negative-ion mode. The mass spectra are dominated by peaks corresponding to [M + O2] ̄?. No fragmentation is observed, making this a very soft ionization technique for samples that are otherwise difficult to analyze by DART. Detection limits for cholesterol were determined to be in the low nanogram range.
Figure
?  相似文献   

5.
Until recently, atmospheric pressure photoionization (APPI) has typically been used for the determination of non-polar halogenated flame retardants (HFRs) by liquid chromatography (LC) tandem mass spectrometry. In this study, we demonstrated the feasibility of utilizing liquid chromatography atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (LC-APCI-MS/MS) for analysis of 38 HFRs. This developed method offered three advantages: simplicity, rapidity, and high sensitivity. Compared with APPI, APCI does not require a UV lamp and a dopant reagent to assist atmospheric pressure ionization. All the isomers and the isobaric compounds were well resolved within 14-min LC separation time. Excellent instrument detection limits (6.1 pg on average with 2.0 μL injection) were observed. The APCI mechanism was also investigated. The method developed has been applied to the screening of wastewater samples for screening purpose, with concentrations determined by LC-APCI-MS/MS agreeing with data obtained via gas chromatography high resolution mass spectrometry.
Figure
LC-APCI-MS/MS for analysis of halogenated flame reterdants  相似文献   

6.
A high-throughput method for rapid screening of active ingredients in drugs has been developed with mass spectrometry coupled to a low-temperature plasma (LTP) probe ion source. Without sample preparation or pretreatment, the active ingredients of 11 types of commercial pharmaceuticals, including hormones, antipyretic analgesics, cardiovascular, digestant, neuro-psychotherapeutic, diuretic, antithyroid, sulfa anti-inflammatory, antiparastic, sedative-hypnotics, and antibacterial, were directly desorbed/ionized and detected by a linear ion trap mass spectrometry (MS). The structures of these ingredients were elucidated by tandem MS. The analysis of 18 methyltestosterone tablets could be accomplished within 1.9 min, which allows fast detection with a speed of approximate 600 samples within 1 h. This work demonstrated that LTP probe ion source combined with MS is a high-throughput method for screening of pharmaceuticals and potentially applied to on-line quality control in pharmaceutical industry.
Figure
Schematic diagram of LTP probe for ambient ionization MS  相似文献   

7.
The use of thin-film solid-phase microextraction (SPME) as the sampling preparation step before direct analysis in real time (DART) was evaluated for the determination of two prohibited doping substances, cocaine and methadone, in urine samples. Results showed that thin-film SPME improves the detectability of these compounds: signal-to-blank ratios of 5 (cocaine) and 13 (methadone) were obtained in the analysis of 0.5 ng/ml in human urine. Thin-film SPME also provides efficient sample cleanup, avoiding contamination of the ion source by salt residues from the urine samples. Extraction time was established in 10 min, thus providing relatively short analysis time and high throughput when combined with a 96-well shaker and coupled with DART technique.
Figure
Schematic protocol for determination of cocaine and methadone in urine by thin-film SPME and DART-MS analysis  相似文献   

8.
A biosensor was developed for the detection of L-phenylalanine (Phe) and demonstrated for use in the diagnosis of phenylketonuria (PKU). It consists of L-phenylalanine dehydrogenase (L-PheDH) immobilized on a membrane, an ultraviolet light-emitting diode excitation system, and a photomultiplier tube. The L-PheDH was immobilized on a teflon membrane modified with 2-methacryloyloxyethyl phosphorylcholine and placed at the distal and of an optical fiber. The concentration of Phe was determined by immersing the sensor into a sample solution that also contained NAD+ and measurement of the fluorescence of the NADH produced by enzymatic reaction. Two L-PheDHs (from Thermoactinomyces intermedius and Sporosarcina sp.) were studied and compared. The fluorescence intensities of the biosensor are linearly related to the L-Phe concentrations in the range from 10 μmol L?1 to 10 mmol L?1. The sensor also was operated in the kinetic mode by differential determination of the slope of the signal within 2 min. The analytical range of the sensor is adequate for application in the genotypic diagnosis of PKU (diagnostic value >600 μmol L?1). High sensitivity, good cost-benefit ratio, and low power consumption are typical features of this biosensing system that can can be applied to routine screening of newborn.
Figure
Nicotinamide adenine dinucleotide (NADH) detecting biosensor of L-phenylalanine (Phe) was developed and demonstrated for diagnosis of phenylketonuria. This biosensor was comprised of L-phenylalanine dehydrogenase immobilized membrane, an ultra violet light-emitting diodes excitation system and a photomultiplier tube. The sensor was sufficient to clinical application of genotypic diagnosis for phenylketonuria.  相似文献   

9.
We show here that baseline separation of dansylated estrone, 17β-estradiol, and 17α-estradiol can be done, contrary to previous reports, within a short run time on a single RP-LC analytical column packed with particles bonded with phenyl-hexyl stationary phase. The chromatographic method coupled with isotope dilution tandem MS offers a simple assay enabling the simultaneous analysis of these analytes. The method employs 13C-labeled estrogens as internal standards to eliminate potential matrix effects arising from the use of deuterated estrogens. The assay also offers adequate accuracy and sensitivity to be useful for biological samples. The practical applicability of the validated method is demonstrated by the quantitative analyses of in vivo samples obtained from rats treated with Premarin®.
Figure
Quantification of estrogens from rat samples by LC–MS/MS  相似文献   

10.
A novel test has been developed for the analysis of methadone in dried blood spot specimens from patients undergoing methadone maintenance treatment. An isocratic reversed-phase high-performance liquid chromatography method with coulometric detection has been optimized for the determination of methadone. The clean-up of dried blood spots was performed by means of an original microextraction by packed sorbent procedure after microwave-assisted extraction of the drug with a suitable solvent. Extraction yields were satisfactory, always being higher than 90.0 %. The calibration curve was linear over the 4–500 ng mL-1 concentration range. The method had satisfactory sensitivity (limit of quantitation of 4 ng mL-1), precision (relative standard deviation less than 5.8 %), selectivity and accuracy (recovery greater than 87.0 %). It was successfully applied to dried blood spot samples collected from heroin-addicted patients undergoing methadone maintenance therapy at dosages between 40 and 240 mg day-1. The statistical analysis (Bland–Altman plot) showed that the results were in good agreement with those found from the analysis of plasma samples obtained from the same patients. Thus, the method has proved to be suitable for the monitoring of methadone by means of dried blood spots.
Figure
Bland-Altman plot and methadone disposition in patients undergoing methadone maintenance treatment  相似文献   

11.
Atmospheric ionization methods are ideally suited for prolonged MS/MS analysis. Data-independent MS/MS is a complementary technique for analysis of biological samples as compared to data-dependent analysis. Here, we pair data-independent MS/MS with the ambient ionization method nanospray desorption electrospray ionization (nanoDESI) for untargeted analysis of bacterial metabolites. Proof-of-principle data and analysis are illustrated by sampling Bacillus subtilis and Pseudomonas aeruginosa directly from Petri dishes. We found that this technique enables facile comparisons between strains via MS and MS/MS plots which can be translated to chemically informative molecular maps through MS/MS networking. The development of novel techniques to characterize microbial metabolites allows rapid and efficient analysis of metabolic exchange factors. This is motivated by our desire to develop novel techniques to explore the role of interspecies interactions in the environment, health, and disease. This is a contribution to honor Professor Catherine C. Fenselau in receiving the prestigious ASMS Award for a Distinguished Contribution in Mass Spectrometry for her pioneering work on microbial mass spectrometry.
Figure
?  相似文献   

12.
13.
A fast and robust high-throughput ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC–TOF MS) profiling method was developed and successfully applied to discriminate a total of 78 Bacillus cereus strains into no/low, medium and high producers of the emetic toxin cereulide. The data obtained by UPLC–TOF MS profiling were confirmed by absolute quantitation of cereulide in selected samples by means of high-performance liquid chromatography with tandem mass spectrometry (HPLC–MS/MS) and stable isotope dilution assay (SIDA). Interestingly, the B. cereus strains isolated from four vomit samples and five faeces samples from patients showing symptoms of intoxication were among the group of medium or high producers. Comparison of HEp-2 bioassay data with those determined by means of mass spectrometry showed differences, most likely because the HEp-2 bioassay is based on the toxic action of cereulide towards mitochondria of eukaryotic cells rather than on a direct measurement of the toxin. In conclusion, the UPLC–electrospray ionization (ESI)–TOF MS and the HPLC–ESI–MS/MS–SIDA analyses seem to be promising tools for the robust high-throughput analysis of cereulide in B. cereus cultures, foods and other biological samples.
Figure
Score plot (comp[1] vs. comp[2]) of UPLC‐TOF MS full scan analysis (50–1,300 Da) of 78 B. cereus strains with color‐coded signal intensity of the accurate mass of pseudo molecular ion of cereulide (m/z 1175.6608, [M+Na]+), from group 1 with the lowest up to group 5 with the highest signal intensity  相似文献   

14.
Since sarcosine and d,l-alanine co-elute on reversed-phase high-performance liquid chromatography (HPLC) columns and the tandem mass spectrometer cannot differentiate them due to equivalent parent and fragment ions, derivatization is often required for analysis of sarcosine in LC/MS systems. This study offers an alternative to derivatization by employing partial elimination of sarcosine by enzymatic oxidation. The decrease in apparent concentration from the traditionally merged sarcosine–alanine peak associated with the enzymatic elimination has been shown to be proportional to the total sarcosine present (R 2?=?0.9999), allowing for determinations of urinary sarcosine. Sarcosine oxidase was shown to eliminate only sarcosine in the presence of d,l-alanine, and was consequently used as the selective enzyme. This newly developed technique has a method detection limit of 1 μg/L (parts per billion) with a linear range of 3 ppb–1 mg/L (parts per million) in urine matrices. The method was further validated through spiked recoveries of real urine samples, as well as the analysis of 35 real urine samples. The average recoveries for low, middle, and high sarcosine concentration spikes were 111.7, 90.8, and 90.1 %, respectively. In conclusion, this simple enzymatic approach coupled with HPLC/MS/MS is able to resolve sarcosine from d,l-alanine leading to underivatized quantification of sarcosine.
Figure
Enzymatic elimination of sarcosine from alanine  相似文献   

15.
In this study, a generic extraction protocol and full-scan high-resolution Orbitrap-mass spectrometry (MS) detection method were developed, enabling the metabolomic screening for carotenoids in tomato fruit tissue. To this end, the carotenoids lutein, zeaxanthin, α-carotene, β-carotene, and lycopene (representing both xanthofylls and carotenes) were considered. The extraction procedure was optimized by means of a D-optimal design and consisted of a liquid–liquid extraction with methanol/tert-butyl methyl ether (1:1, v/v). The considered compounds were detected by a single-stage ExactiveTM mass spectrometer, operating at a mass resolution of 100,000 full width at half maximum. The validation study demonstrated excellent performance in terms of linearity (R 2?>?0.99), repeatability (CV?≤?10.6 %), within-laboratory reproducibility (CV?≤?12.2 %), and mean corrected recovery (ranging from 85 to 106 %). Additionally, a comparative evaluation towards well-established detection techniques, i.e., tandem mass spectrometry (MS/MS) and ultraviolet-visible spectroscopy (UV–VIS) photodiode array, indicated superior performance of high-resolution Orbitrap-MS with regard to specificity/selectivity and sensitivity (with limits of detection ranging from 1.0 to 3.8 pg μL?1). As a result, it may be concluded that high-resolution Orbitrap-MS is a suited alternative for UV–VIS or MS/MS in analyzing carotenoids and may offer significant value in carotenoid research because of the metabolomic screening possibilities.
Figure
Development and validation of a full-scan high-resolution Orbitrap-MS method for the analysis of carotenoids in tomato fruit tissue. Validation enclosed comparison with MS/MS and UV-VIS PDA  相似文献   

16.
Liquid chromatography negative ion electrospray ionisation tandem mass spectrometry has been used for characterisation of naturally occurring prenylated fungal metabolites and synthetic derivatives. The fragmentation studies allow an elucidation of the decomposition pathways for these compounds. It could be shown, that the prenyl side chain is degraded by successive radical losses of C5 units. Both the benzoquinones and the phenolic derivatives display significant key ions comprising the aromatic ring. In some cases, the formation of significant oxygen-free key ions could be evidenced by high-resolution MS/MS measurements. Furthermore, the different types of basic skeletons, benzoquinones and phenol type as well as cyclic prenylated compounds, can be differentiated by their MS/MS behaviour.
Figure
Fruiting bodies of Suillus bovinus, the structure of boviquinone-4 and its negative ion MS2 spectrum  相似文献   

17.
Although dried blood spot (DBS) sampling is increasingly receiving interest as a potential alternative to traditional blood sampling, the impact of hematocrit (Hct) on DBS results is limiting its final breakthrough in routine bioanalysis. To predict the Hct of a given DBS, potassium (K+) proved to be a reliable marker. The aim of this study was to evaluate whether application of an algorithm, based upon predicted Hct or K+ concentrations as such, allowed correction for the Hct bias. Using validated LC-MS/MS methods, caffeine, chosen as a model compound, was determined in whole blood and corresponding DBS samples with a broad Hct range (0.18–0.47). A reference subset (n?=?50) was used to generate an algorithm based on K+ concentrations in DBS. Application of the developed algorithm on an independent test set (n?=?50) alleviated the assay bias, especially at lower Hct values. Before correction, differences between DBS and whole blood concentrations ranged from ?29.1 to 21.1 %. The mean difference, as obtained by Bland-Altman comparison, was ?6.6 % (95 % confidence interval (CI), ?9.7 to ?3.4 %). After application of the algorithm, differences between corrected and whole blood concentrations lay between ?19.9 and 13.9 % with a mean difference of ?2.1 % (95 % CI, ?4.5 to 0.3 %). The same algorithm was applied to a separate compound, paraxanthine, which was determined in 103 samples (Hct range, 0.17–0.47), yielding similar results. In conclusion, a K+-based algorithm allows correction for the Hct bias in the quantitative analysis of caffeine and its metabolite paraxanthine. Graphical Abstract
Percentage differences between uncorrected DBS and whole blood paraxanthine concentrations (upper panel) and between corrected and whole blood paraxanthine concentrations (lower panel) (n = 103)  相似文献   

18.
Extremely low gestational age neonates (ELGAN) frequently require the use of oxygen supply in the delivery room leading to systemic inflammation and oxidative stress that are responsible for increased morbidity and mortality. The objective of this study was to establish reference ranges of a set of representative isoprostanes and prostaglandins, which are stable biomarkers of lipid peroxidation often correlated with oxidative stress-related disorders. First, a quantitative ultra performance liquid chromatography—tandem mass spectrometry (UPLC-MS/MS) method was developed and validated. The proposed analytical method was tailored for its application in the field of neonatology, enabling multi-analyte detection in non-invasive, small-volume urine samples. Then, the lipid peroxidation product concentrations in a total of 536 urine samples collected within the framework of two clinical trials including extremely low gestational age neonates (ELGAN) were analyzed. The access to a substantially large number of samples from this very vulnerable population provided the chance to establish reference ranges of the studied biomarkers. Up to the present, and for this population, this is the biggest reference data set reported in literature. Results obtained should assist researchers and pediatricians in interpreting test results in future studies involving isoprostanes and prostaglandins, and could help assessing morbidities and evaluate effectiveness of treatment strategies (e.g., different resuscitation conditions) in the neonatal field.
Figure
Optimizing clinical outcomes in extremely low gestational age newborns by the determination of lipid peroxidation biomarkers in urine samples employing UPLC-MS/MS.  相似文献   

19.
The detection and identification of proteins adsorbed onto biomaterial surfaces under ambient conditions has significant experimental advantages but has proven to be difficult to achieve with conventional measuring technologies. In this study, we present an adaptation of desorption electrospray ionization (DESI) and liquid extraction surface analysis (LESA) mass spectrometry (MS) coupled with in-situ surface tryptic digestion to identify protein species from a biomaterial surface. Cytochrome c, myoglobin, and BSA in a combination of single and mixture spots were printed in an array format onto Permanox slides, followed by in-situ surface digestion and detection via MS. Automated tandem MS performed on surface peptides was able to identify the proteins via MASCOT. Limits of detection were determined for DESI-MS and a comparison of DESI and LESA-MS peptide spectra characteristics and sensitivity was made. DESI-MS images of the arrays were produced and analyzed with imaging multivariate analysis to automatically separate peptide peaks for each of the proteins within a mixture into distinct components. This is the first time that DESI and LESA-MS have been used for the in-situ detection of surface digested proteins on biomaterial surfaces and presents a promising proof of concept for the use of ambient MS in the rapid and automated analysis of surface proteins.
Graphical abstract
?  相似文献   

20.
Monitoring carnitine and acetylcarnitine levels in biological fluids is a powerful tool for diagnostic studies. Research has recently shown that the analysis of carnitine and related compounds in clinical samples can be accomplished by different analytical approaches. Because of the polar and ionic nature of the analytes and matrix complexity, accurate quantitation is a highly challenging task. Thus, sample processing factors, preparation/cleanup procedures, and chromatographic/ionization/detection parameters were evaluated. On the basis of the results obtained, a rapid, selective, sensitive method based on hydrophilic interaction liquid chromatography–tandem mass spectrometry for the analysis of carnitine and acetylcarnitine in serum and urine samples is proposed. The matrix effect was assessed. The proposed approach was validated, the limits of detection were in the nanomolar range, and carnitine and acetylcarnitine levels were found within the micromolar range in both types of sample.
Figure
Experimental workflow for the carnitine and acetylcarnitine determination in biological samples by HILIC-MS/MS  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号