Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science.  相似文献   

2.
The capability of determining element concentrations at the trace and ultratrace level and isotope ratios is a main feature of inorganic mass spectrometry. The precise and accurate determination of isotope ratios of long-lived natural and artificial radionuclides is required, e.g. for their environmental monitoring and health control, for studying radionuclide migration, for age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, for quality assurance and determination of the burn-up of fuel material in a nuclear power plant, for reprocessing plants, nuclear material accounting and radioactive waste control. Inorganic mass spectrometry, especially inductively coupled plasma mass spectrometry (ICP-MS) as the most important inorganic mass spectrometric technique today, possesses excellent sensitivity, precision and good accuracy for isotope ratio measurements and practically no restriction with respect to the ionization potential of the element investigated—therefore, thermal ionization mass spectrometry (TIMS), which has been used as the dominant analytical technique for precise isotope ratio measurements of long-lived radionuclides for many decades, is being replaced increasingly by ICP-MS. In the last few years instrumental progress in improving figures of merit for the determination of isotope ratio measurements of long-lived radionuclides in ICP-MS has been achieved by the application of a multiple ion collector device (MC-ICP-MS) and the introduction of the collision cell interface in order to dissociate disturbing argon-based molecular ions, to reduce the kinetic energy of ions and neutralize the disturbing noble gas ions (e.g. of 129Xe+ for the determination of 129I). The review describes the state of the art and the progress of different inorganic mass spectrometric techniques such as ICP-MS, laser ablation ICP-MS vs. TIMS, glow discharge mass spectrometry, secondary ion mass spectrometry, resonance ionization mass spectrometry and accelerator mass spectrometry for the determination of long-lived radionuclides in quite different materials.  相似文献   

3.
Introduction Geological resource survey demands for determining various constituents including major, minor, micro, trace and ultra-trace levels of elements for preparing the map of resource distribution of our country. As a powerful and popularly used technique for multi-element analysis, inductively coupled plasma(ICP) atomic emission spectrometry (AES) has been applied to this field for a period of time[1-3]. However, ICP spectrometric determination of those micro, trace and ultratrace elements needs enrichment procedures for improving the detection limit, which is unacceptable in case a great mass of samples should be analyzed as that in the task of geological resource survey. On the other hand, although ICP mass spectrometry(MS) is considered the most powerful method for trace elements determination[4,5], it is difficult for ICP-MS to be used to determine the trace and major analytes simultaneously in a spectrum.  相似文献   

4.
The formation of molecular and cluster ions of different inorganic materials in plasma mass spectrometry – spark source mass spectrometry (SSMS), radiofrequency glow discharge mass spectrometry (rf GDMS), laser ionization mass spectrometry (LIMS), inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) – was investigated and compared. Similar abundance distributions of cluster ions were observed for a graphite sample, for boron nitride/ graphite and for metal oxide/graphite mixtures using different plasma mass spectrometric methods. A correlation of intensities of metal argide ions in ICP-MS with their bond dissociation energies was used to estimate unknown dissociation energies of molecular ionic species. For the elements of the 2nd or 3rd period in the periodic table, the intensities of most argon molecular ions (ArX+) measured by ICP-MS rise with increasing atomic number in a similar manner to the theoretically calculated bond dissociation energies of argon molecular ions.  相似文献   

5.
The use of laser ablation inductively coupled mass spectrometry (laser ICP-MS), in combination with a calibration procedure involving the addition of enriched isotopes, for the determination of trace elements in birch leaves and their ashes is described. Samples are pressed into pellets without binder materials and analyzed using the ICP-MS spectrometer ELAN 5000 with the laser sampler type 320 (Perkin Elmer). The analytical results obtained by two methods are compared with the values obtained after digestion of the same samples and analysis of the resulting solutions by ICP-MS. The results are discussed in terms of precision, accuracy and limits of detections.  相似文献   

6.
The use of laser ablation inductively coupled mass spectrometry (laser ICP-MS), in combination with a calibration procedure involving the addition of enriched isotopes, for the determination of trace elements in birch leaves and their ashes is described. Samples are pressed into pellets without binder materials and analyzed using the ICP-MS spectrometer ELAN 5000 with the laser sampler type 320 (Perkin Elmer). The analytical results obtained by two methods are compared with the values obtained after digestion of the same samples and analysis of the resulting solutions by ICP-MS. The results are discussed in terms of precision, accuracy and limits of detections.  相似文献   

7.
For the determination of trace impurities in ceramic components of solid oxide fuel cells (SOFCs), some mass spectrometric methods have been applied such as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and inductively coupled plasma mass spectrometry (ICP-MS). Due to a lack of suitable standard reference materials for quantifying of analytical results on La x Sr y MnO3 cathode material a matrix-matched synthetic standard-high purity initial compounds doped with trace elements-was prepared in order to determine the relative sensitivity coefficients in SSMS and LA-ICP-MS. Radiofrequency glow discharge mass spectrometry (rf-GDMS) was developed for trace analysis and depth profiling of thick non-conducting layers. Surface analytical techniques, such as secondary ion mass spectrometry (SIMS) and sputtered neutral mass spectrometry (SNMS), were used to determine the element distribution on surfaces (homogeneity) and the surface contaminants of SOFC ceramic layers.Dedicated to Professor Dr. rer. nat. Hubertus Nickel on the occasion of his 65th birthday  相似文献   

8.
The concentrations of 29 trace elements have precisely been determined in 15 international silicate reference materials of the Geological Survey of Japan by spark source mass spectrometry (SSMS) and inductively coupled plasma-mass spectrometry (ICP-MS). The samples span a wide range of concentration levels. Most of the SSMS and ICP-MS values agree within analytical error down to the ppb concentration range. Of particular interest are the data for Nb, Y, Zr, Th, U in samples with low trace element concentrations (<1–10 ppm), for which published data are quite variable. The results obtained generally agree with those of modern sensitive analytical techniques (such as ICP-MS, HPLC), but are often much lower than standard XRF and compiled reference values. It is suggested that these discrepancies arise from calibration and analytical problems for standard XRF and ICP-MS and incorporation of these data into compiled values. More judicious selection of data based on analytical methodology and geochemical behaviour is required for samples which challenge the detection limits of standard analysis.  相似文献   

9.
采用电感耦合等离子体质谱(ICP-MS)与等离子体光谱(ICP-OES)联机同时测定多金属结核样品中常量、微量、痕量元素。样品经高压密封溶样弹消解后,一次气动雾化进样,ICP-OES测定常量和微量元素,ICP-MS测定微量和痕量元素。详细探讨了不同浓度范围元素的测定方式、元素分析信号的采集模式、多原子离子干扰的校正因子。采用ICP-MS与ICP-OES二种方式同时测定Co、Cu、Ni、Zn、V、Ba、Sr,分析结果表明具有较好的一致性。所建立的ICP-MS与ICP-OES联机检测技术用于多金属结核标准样品的分析(Nod-A-1,GSPN-1,GSPN-2,GSPN-3),分析结果与推荐值符合,相对标准偏差小于10%。  相似文献   

10.
Of all the inorganic mass spectrometric techniques, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) plays a key role as a powerful and sensitive microanalytical technique enabling multi- element trace analysis and isotope ratio measurements at trace and ultratrace level. LA-ICP-MS was used to produce images of detailed regionally-specific element distribution in 20 microm thin sections of different parts of the human brain. The quantitative determination of copper, zinc, lead and uranium distribution in thin slices of human brain samples was performed using matrix-matched laboratory standards via external calibration procedures. Imaging mass spectrometry provides new information on the spatially inhomogeneous element distribution in thin sections of human tissues, for example, of different brain regions (the insular region) or brain tumor tissues. The detection limits obtained for Cu, Zn, Pb and U were in the ng g(-1) range. Possible strategies of LA-ICP-MS in brain research and life sciences include the elemental imaging of thin slices of brain tissue or applications in proteome analysis by combination with matrix-assisted laser desorption/ionization MS to study phospho- and metal- containing proteins will be discussed.  相似文献   

11.
An isotope dilution mass spectrometric (IDMS) method with the thermal ionization (TI) technique has been developed for the determination of trace impurities of Cr, Fe, Ni, Cu, Zn, Ag, Cd, Tl, Pb, Th, and U in high-purity HF (50% by weight) used in the semiconductor industry. The evaporation step of the HF solution was carried out in an apparatus which did not significantly contribute to contaminations of the heavy metals to be analysed. This apparatus allowed fast evaporation of the HF solution of up to 200 ml/h and therefore also a fast trace heavy metal/matrix separation was carried out. The evaporation step was also used in connection with inductively coupled plasma mass spectrometry (ICP-MS) when applying the isotope dilution technique and an external calibration for quantification, respectively. The detection limits for TI-IDMS were (in pg/g): Cr=30, Fe=400, Ni=70, Cu=20, Zn=1100, Ag=70, Cd=10, Tl=1, Pb=16, Th=3, and U=1. With ICP-MS in combination with the evaporation step, detection limits of less than 50 pg/g have been achieved for Cr, Ni, and Zn and of <5 pg/g for the other elements except Fe, which could not be determined in concentrations less than 100 ng/g. On the other hand, the detection limits were much higher when the HF matrix was not removed before measuring by ICP-MS. A comparison of the different ICP-MS methods (isotope dilution technique and external calibration for both HF evaporated samples and those with HF matrix) with the results of TI-IDMS has been carried out. An excellent agreement was achieved between the results of TI-IDMS and the two ICP-MS methods using the HF evaporation step, whereas the ICP-MS techniques without HF evaporation essentially deviated from these results. Fe was the only trace element of all investigated heavy metals which could only be analysed by TI-IDMS in high purity HF in a concentration of about 3 ng/g. Although ICP-MS with isotope dilution and external calibration resulted in comparable analytical data, the ICP-IDMS method has some practical advantages such as time-saving and more reliable results.  相似文献   

12.
建立了电感耦合等离子体质谱(ICP-MS)法测定果蔬类、大米等农产品样品中痕量元素的方法.样品通过HNO3-H2 O2混酸体系微波消解,以Rh作为内标溶液消除基体干扰,在仪器最佳条件下测定植物样中镉、铅、铬、铜、镍、锌6种痕量元素.方法的检出限为0.002~0.5μg/g;相对标准偏差(RSD)为0.84% ~7.4%...  相似文献   

13.
Three multielement methods: (1) inductively coupled plasma mass spectrometry (ICP-MS), (2) inductively coupled plasma atomic emission spectroscopy (ICP-AES), and (3) spark source mass spectrometry (SSMS) were used for the determination of additives in the samples of germanium and germanium oxide. The detection limits of direct SSMS and ICP-AES/ICP-MS were compared using the autoclave predissolution of germanium and germanium dioxide samples. It was shown that in the latter case, the detection limits could be significantly improved by the separation of germanium from analytes by distillation. In this case, the detection limits of such limiting elements like Th and U can reach the level n 10?10 wt %.  相似文献   

14.
Traces of cadmium and bismuth in high-purity zinc metal were determined by inductively coupled plasma mass spectrometry (ICP-MS) in combination with flow injection (FI) on-line matrix separation (FI-ICP-MS). The anion-exchange separation method of the potassium iodide (KI) system was applied to the separation of the analytes from the matrix zinc. The analytes, cadmium and bismuth, were adsorbed on the anion-exchange (BIO. RAD AG1-X8) mini-column (1.0 mm i.d.x 100 mm bed length), while the matrix zinc can be completely removed from the anion-exchange resin. The analytes were eluted by 2 mol/l HNO(3) and directly introduced into the ICP-MS. The detection limits (D.L.) obtained by using a single injection (350 microl) were 0.81 and 0.075 ng g(-1) for cadmium and bismuth, respectively. In the case of multi-injection concentration onto the anion-exchange mini-column (five injections 350 microl each), the detection limits could be improved to 0.16 and 0.014 ng g(-1) for cadmium and bismuth, respectively. The reproducibilities of the single injection and the multi-injection method were satisfactory with a relative standard deviation of less than 5% (at the 10 and 1 ng ml(-1) level for the single injection and the multi-injection method, respectively). The method was successfully applied to the determination of trace impurities in four samples of high-purity zinc metal (7 nines grade) and three standard reference materials of high-purity unalloyed zinc samples (from NIST).  相似文献   

15.
地球化学样品中钒的测定方法主要有原子吸收光谱法、等离子体发射光谱法(ICP-AES)、电感耦合等离子体质谱法(ICP-MS)和X射线荧光光谱法.选用国家一级标样,分别用4种方法测定样品含量值,依次对方法检出限、准确度、精密度、加标回收率作比较.经对比,4种方法测定值与推荐值都基本吻合.等离子体发射光谱法检出限低,线性范围更宽,准确度与精密度更好,更适用于地球化学样品中钒批量的测试.  相似文献   

16.
萤石是一种重要的战略性非金属矿产资源,本文对中国国家标准、行业标准、国际标准(ISO)、美国标准(ASTM)以及俄罗斯标准(GOST)中的萤石成分分析标准方法的现状进行了介绍。对近年来X射线荧光光谱法(XRF)、电感耦合等离子体发射光谱法(ICP-AES)、电感耦合等离子体质谱法(ICP-MS)、激光诱导击穿光谱法(LIBS)等技术在萤石成分分析中的应用以及标准物质/标准样品研制情况进行了总结和评述。文章认为,萤石分析测试技术标准体系相对完备,XRF、ICP-AES、ICP-MS等仪器分析测试技术已普遍应用于萤石样品实验室分析,建议尽快研究并建立萤石中稀土等微量元素测定的标准方法,并开展相应标准物质/标准样品的研制,同时应大力开展原位在线分析技术的研究与开发,以适应工业在线自动化监测的需求,LIBS与在线XRF技术联合在萤石在线分析方面具有良好的应用潜力。  相似文献   

17.
Trace impurities in high-purity cadmium were determined by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). To overcome some potentially problematic spectral interference, measurements were acquired in both medium and high-resolution modes. The matrix effects due to the presence of excess HCl and cadmium were evaluated. The optimum conditions for the determination were tested in this experiment and discussed. The detection limits ranged from 0.01 to 0.27 microg g-1, depending on the elements. The results for the determination of 22 trace elements in high-purity cadmium are presented.  相似文献   

18.
A radiofrequency (rf) spark discharge in vacuum developing across the surface of dielectrics – a so-called gliding spark – has been applied to the direct mass spectrometric trace analysis of nonconducting materials. The special configuration of the electrodes strengthened the electric field over the surface of a nonconducting sample and created optimum conditions for the sputtering and ionization of the sample material. Mass spectrometric investigations of the charge composition of atomic ion and molecular ion formation in radiofrequency gliding spark plasma showed a significant difference to that of the original rf spark discharge between two conducting electrodes. The analytical figures of merit (reproducibility, relative sensitivity factors and detection limits of chemical elements) of gliding spark source mass spectrometry have been studied by using the glass standard reference materials NIST SRM 610 and 611 for the determination of trace elements in glass matrix.  相似文献   

19.
The present paper describes the inductively coupled plasma mass spectrometric (ICP-MS) determination of rare earth elements (REEs), thorium and uranium in forest, pasture, field and kitchen garden soils from a Russian territory and in certified reference materials (JLK-1, JSD-2 and BCR-1). In addition to concentration data, strontium isotopic composition of the soil samples were measured by thermal ionization mass spectrometry. The measurements contributed to the understanding of the background levels of these elements in an area contaminated due to Chernobyl accident. There was not a significant variation in the concentration of REEs at different depth levels in forest soil samples, however, the ratio of Th/U varied from 3.32 to 3.60. Though concentration of U and Th varied to some extent, the ratio did not show much variation. The value of 87Sr/86Sr ratio, was in the top layer soil sample relatively higher than in the lower layers.  相似文献   

20.
Solid sampling (SS) graphite furnace atomic absorption spectrometry (GFAAS) and solution-based (SB) methods of GFAAS, flame atomic absorption spectrometry (FAAS), inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) were elaborated and/or optimized for the determination of Cr, Fe and Mn trace elements used as dopants in lithium niobate optical crystals.  相似文献   