首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Diffusion of spins between physical or virtual, communicating compartments having different states of longitudinal magnetization leads to diffusion-driven longitudinal relaxation. Herein, in two model systems, the effects of diffusion-driven longitudinal relaxation are explored experimentally and analyzed quantitatively. In the first case, longitudinal relaxation in a single slice of a water phantom is monitored spectroscopically as a function of slice thickness. In the second case, mimicking vascular flow/diffusion effects, longitudinal relaxation is monitored in a two-compartment, semi-permeable fiber phantom. In both cases, apparent longitudinal relaxation, though clearly multi-exponential, is well-modeled as bi-exponential.  相似文献   

2.
We have estimated the accuracy of volume measurements of multiple sclerosis (MS) lesions made using magnetic resonance imaging (MRI) for lesions of comparable diameter to the image slice thickness. We used a phantom containing objects of known volume and obtained images using a range of slice thicknesses. Measurements on the phantom were used to assess a theoretical model, which was then employed to investigate the effects of image dimensions and geometry upon volume measurement accuracy. We observed measured volume to be dependent upon slice thickness. Thin slices gave the most accurate estimate of volume. As slice thickness increased relative to object diameter, the error in the volume measurement increased (to as much as 100%), the volume measured being dependent on the position of the object relative to the slice center. Using a signal intensity threshold value of 50% to outline objects gave results closest to the actual volume. As expected, a lower threshold value tended to give higher volume estimates (up to 100% larger), as did a semi-automated local edge detection technique. For accurate volume measurement, the slice thickness should be no more than a fifth of anticipated object diameter. For typical MS lesions (7 mm in diameter), this implies using a 1.5-mm slice thickness. For serial studies, a repositioning error of 1 mm could lead to differences in the volume measurement of individual lesions of up to 12% between studies for lesions of typical MS size and 5-mm slice thickness. These results emphasize the need for accurate patient repositioning, relatively thin slices, for regular quality assurance checks to ensure that pixel size and slice position are correct and stable over time, and that lesion outlining is performed in a consistent fashion. We would recommend the use of a 3D sequence with 1 mm cubic voxels for accurate measurements of MS lesions.  相似文献   

3.
Flow-sensitive experiments (FAIR) have been performed on a tube-flow phantom in order to validate quantitative perfusion measurements on humans. A straight-forward correspondence between perfusion and bulk-flow is found. It is shown that the flow phantom model only holds when the slice profiles of the involved RF pulses are taken into account. A small flow-independent off-set may be present in the data. The off-set is explained by the model. Based on the correspondence between the phantom and the in vivo models, it is shown that the lowest flow values that could be measured in the phantom correspond to perfusion values lower than the cortical perfusion in the brain. Thus, the experimental accuracy and the computational methods for quantitative perfusion measurements in vivo can be validated by a tube-flow phantom.  相似文献   

4.
In this paper, a method of three-dimensional (3D) vessel localization is presented to allow the identification of a vessel of interest, the selection of a vessel segment, and the determination of a slice orientation to improve the accuracy of phase-contrast magnetic resonance (PCMR) angiography. A marching-cube surface-rendering algorithm was used to reconstruct the 3D vasculature. Surface-rendering was obtained using an iso-surface value determined from a maximum intensity projection (MIP) image. This 3D vasculature was used to find a vessel of interest, select a vessel segment, and to determine the slice orientation perpendicular to the vessel axis. Volumetric flow rate (VFR) was obtained in a phantom model and in vivo using 3D localization with double oblique cine PCMR scanning. PCMR flow measurements in the phantom showed 5. 2% maximum error and a standard deviation of 9 mL/min during steady flow, 7.9% maximum error and a standard deviation of 13 mL/min during pulsatile flow compared with measurements using an ultrasonic transit-time flowmeter. PCMR VFR measurement error increased with misalignment at 10, 20, and 30 degrees oblique to the perpendicular slice in vitro and in vivo. The 3D localization technique allowed precise localization of the vessel of interest and optimal placement of the slice orientation for minimum error in flow measurements.  相似文献   

5.
The radio frequency (RF) slice profile effects on T1 and T2 estimation in magnetic resonance fingerprinting (MRF) are investigated with respect to time-bandwidth product (TBW), flip angle (FA) level and field inhomogeneities. Signal evolutions are generated incorporating the non-ideal slice selective excitation process using Bloch simulation and matched to the original dictionary with and without the non-ideal slice profile taken into account. For validation, phantom and in vivo experiments are performed at 3T. Both simulations and experiments results show that T1 and T2 error from non-ideal slice profile increases with increasing FA level, off-resonance, and low TBW values. Therefore, RF slice profile effects should be compensated for accurate determination of the MR parameters.  相似文献   

6.
Susceptibility artifacts due to metallic prostheses are a major problem in clinical magnetic resonance imaging. We theoretically and experimentally analyze slice distortion arising from susceptibility differences in a phantom consisting of a stainless steel ball bearing embedded in agarose gel. To relate the observed image artifacts to slice distortion, we simulate images produced by 2D and 3D spin-echo (SE) and a view angle tilting (VAT) sequence. Two-dimensional SE sequences suffer from extreme slice distortion when a metal prosthesis is present, unlike 3D SE sequences for which--since slices are phase-encoded--distortion of the slice profile is minimized, provided the selected slab is larger than the region of interest. In a VAT sequence, artifacts are reduced by the application of a gradient along the slice direction during readout. However, VAT does not correct for the excitation slice profile, which results in the excitation of spins outside the desired slice location and can lead to incorrect anatomical information in MR images. We propose that the best sequences for imaging in the presence of a metal prosthesis utilize 3D acquisition, with phase encoding replacing slice selection to minimize slice distortion, combined with excitation and readout gradient strengths at their maximum values.  相似文献   

7.
Eddy current-induced geometric distortions of single-shot, diffusion-weighted, echo-planar (DW-EP) images are a major confounding factor to the accurate determination of water diffusion parameters in diffusion tensor MRI (DT-MRI). Previously, it has been suggested that these geometric distortions can be removed from brain DW-EP images using affine transformations determined from phantom calibration experiments using iterative cross-correlation (ICC). Since this approach was first described, a number of image-based registration methods have become available that can also correct eddy current-induced distortions in DW-EP images. However, as yet no study has investigated whether separate eddy current calibration or image-based registration provides the most accurate way of removing these artefacts from DT-MRI data. Here we compare how ICC phantom calibration and affine FLIRT (http://www.fmrib.ox.ac.uk), a popular image-based multi-modal registration method that can correct both eddy current-induced distortions and bulk subject motion, perform when registering DW-EP images acquired with different slice thicknesses (2.8 and 5 mm) and b-values (1000 and 3000 s/mm(2)). With the use of consistency testing, it was found that ICC was a more robust algorithm for correcting eddy current-induced distortions than affine FLIRT, especially at high b-value and small slice thickness. In addition, principal component analysis demonstrated that the combination of ICC phantom calibration (to remove eddy current-induced distortions) with rigid body FLIRT (to remove bulk subject motion) provided a more accurate registration of DT-MRI data than that achieved by affine FLIRT.  相似文献   

8.
Imaging colonies of bacteria in water suspension using NMR requires that the water inside the bacteria can be differentiated from the surrounding water. This is commonly carried out by using diffusion-weighted pulsed field gradient techniques. However, it is also possible to use the diffusion sensitivity inherent in stray field imaging (STRAFI). In STRAFI, the subject to be imaged is normally moved along the axis of a superconducting magnet so that it passes through the sensitive slice. However, by moving the sample in the transverse direction and by using a long copper strip in place of a surface induction coil, a diffusion-weighted one-dimensional projection profile can be obtained across the sensitive slice. Profiles from a water phantom and from a bacteria suspension show convincing discrimination between intracellular and extracellular water.  相似文献   

9.
Recently, a new technique has been demonstrated which effectively refocusses the dephasing effects of spins moving during application of MR imaging gradients. This paper presents an analysis of imaging axes significance in spin dephasing for motion occurring along the slice select, read and phase-encoding directions. A flow phantom under constant flow conditions in all experiments was used to provide complete spin dephasing when "traditional" imaging gradients were used. The MAST technique was used to refocus along various combinations of imaging axes, and variable number of terms from the Taylor expansion of motion along them. Results indicate that motion along any imaging axis can be refocussed effectively when MAST gradients are used along only the slice select and read axis.  相似文献   

10.
A magnetic resonance imaging method for simultaneous and accurate determination of gaseous diffusion constant and longitudinal relaxation time is presented. The method is based on direct observation of diffusive motion. Initially, a slice-selective saturation of helium-3 (3He) spins was performed on a 3He/O2 phantom (9 atm/2 atm). A time-delay interval was introduced after saturation, allowing spins to diffuse in and out of the labeled slice. Following the delay interval a one-dimensional (1-D) projection image of the phantom was acquired. A series of 21 images was collected, each subsequent image having been acquired with an increased delay interval. Gradual spreading of the slice boundaries due to diffusion was thus observed. The projection profiles were fit to a solution of the Bloch equation corrected for diffusive motion. The fitting procedure yielded a value of D3He = 0.1562+/-0.0013 cm2/s, in good agreement with a measurement obtained with a modified version of the standard pulsed-field gradient technique. The method also enabled us to accurately measure the longitudinal relaxation of 3He spins by fitting the change of the total area under the projection profiles to an exponential. A value of T1 = 1.67 s (2 T field) was recorded, in excellent agreement with an inversion recovery measurement.  相似文献   

11.
Single-shot echo-planar imaging is becoming the most widely used technique for magnetic resonance diffusion imaging, since it enables measurement of diffusion coefficients in human brain without motion artifacts. However, its reliability is limited by geometrical distortions due to eddy currents. In this report, an isotropically weighted echo-planar pulse sequence, optimized to give the maximum signal-to-noise ratio in the computed trace image and designed to produce inherently low distortions, is presented. It is also shown how the residual translational distortion can be easily characterized and removed by postprocessing. A full characterization of the distortion artifact involves a few measurements on a phantom, in order to estimate the distortion as a function of slice orientation, which can then be used to correct any slice orientation. Results of applying the image translation correction to data collected from a patient are presented.  相似文献   

12.
Conventional bolus-chase acquisition generates peripheral runoff images using a single injection of the contrast material. Low spatial resolution, small slice coverage and venous contamination are major problems especially in the distal stations. A technique is presented herein in which whole-body magnetic resonance angiography is performed using a dual-contrast-injection four-station acquisition protocol. Bolus sharing was performed between two stations: the abdomen and calf stations share the first bolus injection, while the thorax and thigh stations share the second bolus injection. The combination of variable density sampling and elliptical centric acquisition order was applied to the abdomen and thorax stations. The scan time was extended to generate high spatial resolution arterial phase images with broad slice coverage for the calf and thigh stations. The feasibility of this technique was demonstrated using phantom and in vivo human volunteer studies.  相似文献   

13.
近年来,为提高磁共振成像(MRI)信号信噪比(SNR)、缩短成像时间,同时多层成像技术受到了极大的关注.为了实现同时多层的选择性激发,现有的多层成像序列大多使用组合射频(RF)脉冲,该脉冲可包含多个独立的幅值相同相位不同的简单脉冲,由于其采用简单的线性叠加方法,该类脉冲射频功率随脉冲数量呈现平方增长,因而应用受限.针对这一问题,基于自旋动力学和优化控制原理,本文提出了一种针对同时多层MRI的选择性射频脉冲的数值优化方法,该方法充分运用射频脉冲的调控机制,获得优化脉冲,并配合层选梯度,可实现任意层厚、层间距、层数的同时高效选择性激发.最后,通过数字模体的同时多层模拟成像实验验证了优化脉冲的有效性.  相似文献   

14.
The shortest possible delay (Td) between slice selection and data acquisition is important for producing high quality 31P spectra. In single slice multivoxel spectroscopic imaging, conventional excitation using sinc-shaped rf pulses within typical gradient limitations can have values of Td that lead to significant spectral distortion and loss of signal. Truncated sinc excitation, which ends the excitation close to the center of the main rf lobe has been suggested for MR angiographic applications to produce short values of Td. In this work, the slice profiles, spectral signal-to-noise ratio (SNR) and spectral distortions are compared using the minimum delay achievable on a commercial MRI system for conventional 'sinc' rf excitation and truncated sinc excitation. Slice profiles are calculated using the Bloch equations and measured with a phantom. SNR and spectral distortions are evaluated from whole slice spectra on a human volunteer. On an MRI system with 1 G/cm gradients (0.5 msec risetime), for a 2.5-cm slice at 31P frequencies, conventional excitation can be adjusted to achieve Td = 2.5 msec while truncated sinc excitation yields Td = 1.5 msec. The truncated sinc excitation's shorter value of Td leads to much smaller spectral distortions, but its slice profile has "dispersive tails" which increase as more of the rf is truncated. Slice profile corrected SNR for the beta-ATP peak of 31P on a human volunteer is equivalent for both sequences while, qualitatively, in the PDE region the truncated sinc approach has improved SNR.  相似文献   

15.
The dual echo steady-state (DESS) sequence has been shown successful in achieving fast T2 mapping with good precision. Under-estimation of T2, however, becomes increasingly prominent as the flip angle decreases. In 3D DESS imaging, therefore, the derived T2 values would become a function of the slice location in the presence of non-ideal slice profile of the excitation RF pulse. Furthermore, the pattern of slice-dependent variation in T2 estimates is dependent on the RF pulse waveform. Multi-slice 2D DESS imaging provides better inter-slice consistency, but the signal intensity is subject to integrated effects of within-slice distribution of the actual flip angle. Consequently, T2 measured using 2D DESS is prone to inaccuracy even at the designated flip angle of 90°. In this study, both phantom and human experiments demonstrate the above phenomena in good agreement with model prediction.  相似文献   

16.
A conventional high-resolution NMR spectrometer has been adapted for a three-dimensional imaging experiment which involves two spatial coordinates plus chemical shift. One dimension has far greater digital resolution than the other two, and when it is used to encode the chemical shifts it is possible to obtain separate slice images showing the distribution of each chemical species within the imaging plane. The method is illustrated using a tube phantom containing ethanol and water, in this case the ethanol gives sufficiently narrow finewidths that it is possible to obtain a separate image from the individual transitions of each multiplet.  相似文献   

17.
Emulsions of perfluorotributylamine (FTBA) and perflubron were evaluated for their utility in 19F echo planar imaging. Fluorine images of the emulsions were obtained in a phantom and two mice that had been predosed. Both agents, but particularly perflubron, show potential for fluorine echo planar studies because of the long spin-spin relaxation times of the CF3 resonances. High resolution thin slice images obtained in as little as 26.6 ms are presented.  相似文献   

18.
An NMR flow quantification technique applicable to metabolite flow in plants is presented. It combines flow sensitive magnetization preparation with slice selective spectroscopy. Flow encoded NMR spectroscopy is described to quantify, for the first time, flow velocities of metabolites in plants non-invasively. Flow sensitivity is introduced by magnetization preparation based on a stimulated echo experiment, prior to slice selective spectroscopy. For flow quantification eight different flow-weighted spectra are collected. With this flow preparation very slow flow velocities down to 0.1mm/s can be detected and small amounts of flowing metabolites can be observed despite the large background signal of stationary and flowing water. Important sequence optimization steps include appropriate choice of experimental parameters used for flow encoding as well as complete balancing of eddy currents from the flow encoding gradients. The method was validated in phantom experiments and applied in vivo. Examples of quantitative flow measurements of water and metabolites in phantoms and plants are provided to demonstrate the reliability and the performance of flow encoded spectroscopy.  相似文献   

19.
Synchronized EPI phase contrast velocimetry in a mixing reactor   总被引:3,自引:0,他引:3  
Notwithstanding its widespread use in cardiovascular and functional MRI studies, Echo Planar Imaging (EPI) has only recently been subjected to systematic validation studies. Most velocity measurement studies employing such ultrafast MRI methods involve the use of phantoms characterized by rigid or deformable solid motion. The current implementation involves a rotating phantom (angular velocity up to 10.5 rpm) with a superimposed swirling liquid flow (with axial velocities ranging between 0.145 and 0.27 cm/s) of water doped with copper sulfate. The standard implementation of single-shot EPI with phase contrast velocity encoding allows the complete mapping of the Eulerian velocity field in slices perpendicular to the rotation axis following a subtractive procedure requiring the synchronized acquisition of each velocity component on each selected transverse slice during two revolutions of the rotor. The image acquisition time is 100 ms (per velocity component) at each 64 x 64 slice. In addition to acquiring full-field velocity data for future direct comparisons with other techniques, EPI is employed here for the first time to reconstruct the three-dimensional flow field between the blades of a partitioned pipe mixer.  相似文献   

20.
A portable single sided sensor to render depth profiles of MR signal non-invasively is presented. The device utilizes a tailored permanent magnet array producing flat sensitive volumes up to 40 mm from the mobile inspection head. Automated slice selection is performed using a set of switched capacitors in the tuning and receiver circuits. A single channel spectrometer drives the multi-slice acquisition. The RF coil and magnet array geometries have been tailored to house gradient sets to further extend the image rendering capabilities for in-plane spatial resolution (2D and 3D MRI). The probe has been tested acquiring moisture profiles in concrete and porous rocks and measuring diffusion parameters on a phantom sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号