首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 476 毫秒
1.
机载激光3D探测成像系统的关键技术   总被引:1,自引:0,他引:1  
孟庆季  张续严  周凌  王超 《中国光学》2011,4(4):327-339
介绍了机载激光3D探测成像系统的应用领域和国内外发展现状,概括了小型无人机载激光3D成像检测系统(JIGSAW)、机载激光测深系统(LADS)、直升机3D-LZ Imaging LADAR及机载对地高分辨详查系统的基本组成、技术指标以及各自的特点。阐述了激光3D成像系统的工作原理与扫描方式的分类,并重点对其单元核心技术即激光测距系统、激光光轴控制与指向测量系统、数据图像处理技术与显示系统进行了研究。最后,简单综述了机载激光3D探测成像系统的发展前景。  相似文献   

2.
程志远  马彩文  马青 《物理学报》2017,66(24):244202-244202
激光相干场成像系统发射多束激光,经大气传输对远程目标成像,大气湍流引起的激光束光强扰动是影响成像质量的一个关键因素.本文从湍流引起的激光束光强扰动对回波解调信号的影响关系入手,建立了激光回波光强扰动因子对相位闭合系数和成像频谱分量的降质传函理论模型;基于三光束激光相干场成像系统仿真验证了理论模型的有效性.研究表明激光相干场成像频谱分量和成像像质主要受三光束相位闭合求解算法中第二光束光强扰动影响.该研究揭示了激光回波光强扰动对成像像质的影响机理,对于分析大气湍流等引起的光强扰动降质效应和合理分配多光束光强稳定性以提高成像质量具有理论指导意义.  相似文献   

3.
Rao B  Maslov K  Danielli A  Chen R  Shung KK  Zhou Q  Wang LV 《Optics letters》2011,36(7):1137-1139
Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional (2D) raster scans of 100 by 50 points. The corresponding 2D B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23 ± 0.03 μm for Au nanowire imaging, which is 2.0 times below the diffraction limit.  相似文献   

4.
王飞  汤伟  王挺峰  郭劲 《中国光学》2015,8(3):422-427
为了实现对目标的无扫描阵列激光三维成像并研究系统参数对三维成像距离分辨率的影响,研制了8×8 pixel激光三维成像接收机。接收机采用线性模式APD阵列,设计了模拟信号放大、阈值处理将回波光信号转换为数字信号后,利用FPGA设计实现64通道高精度阵列计时系统,实现了对目标的无扫描实时三维成像功能。首先对设计完成的三维成像接收机组成及成像原理进行了介绍,对三维成像接收机中APD探测器阵列信号的模拟处理和数字处理流程和实现方式进行了说明。随后分别对三维成像的核心FPGA计时系统及探测器整体进行了电子学测试和实验测试。测试结果表明,FPGA计时子系统的时间分辨率优于140 ps,三维成像系统整体距离分辨率在0.2 m左右。最后对分辨率的误差进行了分析,结果表明,激光回波强度波动是影响此接收机距离分辨率的最主要因素。  相似文献   

5.
介绍了机载激光3D探测成像系统的应用领域和国内外发展现状,概括了小型无人机载激光3D成像检测系统(JIGSAW)、机载激光测深系统(LADS)、直升机3D-LZ Imaging LADAR及机载对地高分辨详查系统的基本组成、技术指标以及各自的特点。阐述了激光3D成像系统的工作原理与扫描方式的分类,并重点对其单元核心技术即激光测距系统、激光光轴控制与指向测量系统、数据图像处理技术与显示系统进行了研究。最后,简单综述了机载激光3D探测成像系统的发展前景。  相似文献   

6.
An approach for 3D building reconstruction automatically based on aerial CCD image and sparse laser scanning sample points is presented in this paper. The geometry shape of a building is shown very clearly in the aerial high-resolution CCD image, so we use Laplacian sharpening operator and threshold segmentation to extract the edges of CCD image first, and then pixel connectivity is used to extract the linear features in the CCD image. Bi-direction projection histogram and line matching are proposed to extract the contours of buildings. The height of the building is determined from sparse laser sample points which are within the contour of the buildings extracted from CCD image; therefore the 3D information of each building is reconstructed. We reconstruct 3D buildings correctly by this approach using real aerial CCD and sparse laser rangefinder data.  相似文献   

7.
To balance conflicts for high-resolution, large-field-of-view and real-time imaging, a retina-like imaging method based on time-of flight (TOF) is proposed. Mathematical models of 3D imaging based on MOEMS are developed. Based on this method, we perform simulations of retina-like scanning properties, including compression of redundant information and rotation and scaling invariance. To validate the theory, we develop a prototype and conduct relevant experiments. The preliminary results agree well with the simulations.  相似文献   

8.

Objective

Development of a fast 3D high-resolution magnetic resonance imaging (MRI) protocol for improved carotid artery plaque imaging.

Methods

Two patients with carotid atherosclerosis disease underwent 3D high-resolution MRI which included time-of-flight and T1-weighted variable flip angle, fast-spin-echo (FSE) imaging, pre- and post-intravenous gadolinium-based contrast agent administration.

Results

Good quality images with intrinsic blood suppression were obtained pre- and post-contrast administration using a 3D FSE sequence. The plaque burden, lipid core volume, hemorrhage volume and fibrous cap thickness were well determined.

Conclusions

3D high-resolution MR imaging of carotid plaque using TOF and 3D FSE can achieve high isotropic resolution, large coverage, and excellent image quality within a short acquisition time.  相似文献   

9.
密度高、成像分辨率高、成像速度快的X射线数字成像检测需要高能微焦点大剂量X射线源,高品质电子源是实现这一X射线源的关键手段。基于中国工程物理研究院太赫兹自由电子激光的主加速器,验证了低发射度、低能散度的高亮度电子束实现高能微焦点的可行性,得到电子束半高全宽尺寸小于70μm的9 MeV微焦点,并初步开展成像实验,双丝像质计焦斑清晰分辨9D号丝,丝直径0.13 mm。  相似文献   

10.
Photoacoustic(PA) microscopy comes with high potential for human skin imaging, since it allows noninvasively high-resolution imaging of the natural hemoglobin at depths of several millimeters. Here, we developed a PA microscopy to achieve high-resolution, high-contrast, and large field of view imaging of skin. A three-dimensional(3D) depth-coding technology was used to encode the depth information in PA images, which is very intuitive for identifying the depth of blood vessels in a two-dimensional image, and the vascular structure can be analyzed at different depths. Imaging results demonstrate that the 3D depth-coded PA microscopy should be translated from the bench to the bedside.  相似文献   

11.
机载激光3D探测成像是通过激光主动成像产生目标的角-角-距、角-角-速度3D图像的一种新的探测成像技术.本文重点阐述了机载激光3D探测成像系统的原理、功能和系统的组成.介绍了该系统在军事和民用两大领域的应用,详细地讨论了近几年机载激光3D探测成像技术的国内外发展现状及动态,总结了该项技术的发展方向.认为国外的机载激光3...  相似文献   

12.
Li G  Sun PC  Lin PC  Fainman Y 《Optics letters》2000,25(20):1505-1507
A novel interference microscope for three-dimensional (3D) imaging based on a wavelength-to-depth encoding technique is presented. Wavelength-to-depth encoding is realized by use of a diffractive lens and wavelength tuning. A high depth resolution of 0.71 mum is obtained with 0.90-N.A. objective lenses. Experimental measurements of a four-level grating are presented, and the results are found to be comparable with those obtained with a Dektak profilometer and a similar interference microscope that uses mechanical depth scanning. The system is promising for fast, noncontact, high-resolution 3D imaging.  相似文献   

13.
Optical coherence microscopy (OCM) is demonstrated with a high-speed, broadband, reflective-grating phase modulator and a femtosecond Ti:Al2O3 laser. The novel system design permits high-resolution OCM imaging in a new operating regime in which a short coherence gate is used to relax the requirement for high-numerical-aperture confocal axial sectioning. In vivo cellular imaging is demonstrated in the Xenopus laevis tadpole and in human skin with a 3-microm coherence gate and a 30-microm confocal gate. The ability to achieve cellular imaging with a lower numerical aperture should facilitate the development of miniaturized probes for in vivo imaging applications.  相似文献   

14.
于潇  姚园  徐正平 《中国光学》2016,9(3):349-355
针对机载平台激光3D成像系统的轻小型需求,设计了采用APD阵列的共口径激光收发光学系统。在分析激光成像系统照明方式及其光学系统结构的基础上,给出了激光3D成像光学系统结构框图:激光经衍射元件实现分束照明,采用双工反射镜实现收发光路的耦合。该光学系统用于2 km以内的目标三维成像,根据激光测距方程,确定了接收光学系统的参数以获得满足信噪比的回波能量。为避免造成像素之间串扰,设计了5倍扩束比的发射光学系统。最后,采用偏振片与1/4波片相结合的方式消除杂光,降低了发射光路对接收光路的影响。设计结果表明:接收光学系统弥散斑直径小于120μm,畸变小于0.2%。该光学系统体积小、重量轻,成像质量良好,可为同类激光成像光学系统提供借鉴参考。  相似文献   

15.
Because of its high measuring speed, moderate accuracy, low cost and robustness in the industrial field, 3D laser scanning has been widely used in a variety of applications. However, the measurement of a 3D profile of a high dynamic range (HDR) brightness surface such as a partially highlighted object or a partial specular reflection remains one of the most challenging problems. This difficulty has limited the adoption of such scanner systems. In this paper, an optical imaging system based on a high-resolution liquid crystal on silicon (LCoS) device and an image sensor (CCD or CMOS) was built to adjust the image's brightness pixel by pixel as required. The radiance value of the image captured by the image sensor is constrained to lie within the dynamic range of the sensor after an adaptive algorithm of pixel mapping between the LCoS mask plane and image plane through the HDR imaging system is added. Thus, an HDR image was reconstructed by the LCoS mask and the CCD image on this system. The significant difference between the proposed system and a traditional 3D laser scanner system is that the HDR image was used to calibrate and calculate the 3D profile coordinate. Experimental results show that HDR imaging can enhance 3D laser scanner system environmental adaptability and improve the accuracy of 3D profile measurement.  相似文献   

16.
In order to further improve the resolution for a high-resolution electron hologram, the aberration working on the hologram must be corrected. Since it is rather difficult to precisely control aberration coefficients in the experimental stage, we proposed an amplitude contrast D criterion of imaging wave to determine the working aberration from the hologram itself. In the determination or correction of the aberration, we assume a symmetrical aberration function is parameterized only by a spherical aberration coefficient and a defocus value. First, D is calculated from a holographically reconstructed imaging wave of YBa(2)Cu(3)O(7-x) for each combination of these parameters. The working aberration on the imaging wave is determined from the combination of the parameters by noting the maximum or minimum D of the imaging wave at some specifically chosen thickness regions. The theoretical validity for the D criterion is then proved with three-beam dynamical diffraction formula. Finally, the 'experimental' examination for the D criterion is successfully performed on the reconstructed image wave for the Sigma=9 interface structure of a wedge-shaped silicon sample.  相似文献   

17.
An optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence (IR FSPGR) on a 3-T scanner for carotid plaque imaging is described. It offers clear blood and fat signal suppression at the carotid artery bifurcation and highlights the regions of carotid plaque affected by hemorrhage at 3 T with high contrast and contrast-to-noise ratio compared with other sequences. It can potentially be used to replace the more traditional noncontrast T1-weighted 2D black-blood imaging for hemorrhage detection and offers additional benefits of high-resolution 3D volumetric visualization.  相似文献   

18.
臧博  郭睿  唐禹  邢孟道 《光子学报》2014,39(12):2152-2157
逆合成孔径激光成像雷达受激光调制技术以及回波相位信息易受大气湍流破坏的限制,采用常规的相位相干积累类方法得到目标二维高分辨图像很困难.针对这一情况,提出了一种基于逆Radon变换的实包络成像算法.利用回波距离脉冲压缩后的实包络信息,实现方位向的非相干积累,最终得到二维高分辨图像.通过该算法,成像系统可以使用非相干激光信号,在脉冲重复频率较低且存在大气湍流的情况下,也可以获得高质量的成像结果.仿真实验验证了此算法的有效性和优越性.  相似文献   

19.
朱耘 《应用光学》1999,20(4):22-26
主要介绍现任中激光水下三维成像新主邓纹影管激光雷达三维成像以及采用三角法和激光雷达的相关技术三维成像。  相似文献   

20.
The construction and utilization of a high-resolution cw dye laser spectrometer is described. The laser incorporates pressure tuned intra-cavity etalons enabling the single mode output laser frequency to be tuned more than one nm in a continuous scan. In the scan the laser jumps from one cavity mode to the next in ~ 50 MHz steps. In comparison to molecular Doppler widths this mode jumping is negligible. As an example of the use of the instrument, a high-resolution absorption spectrum of molecular iodine between the sodium D lines is presented. A unique frequency counter provides the calibration of the absorption spectrum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号