首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An analytical method based on dispersive solid‐phase extraction with a multiwalled carbon nanotubes sorbent coupled with positive pulse glow discharge ion mobility spectrometry was developed for analysis of 30 pesticide residues in drinking water samples. Reduced ion mobilities and the mass–mobility correlation of 30 pesticides were measured. The pesticides were divided into five groups to verify the separation capability of pulse glow discharge in mobility spectrometry. The extraction conditions such as desorption solvent, ionic strength, conditions of adsorption and desorption, the amounts of multiwalled carbon nanotubes, and solution pH were optimized. The enrichment factors of pesticides were 5.4‐ to 48.7‐fold (theoretical enrichment factor was 50‐fold). The detection limits of pesticides were 0.01~0.77 μg/kg. The linear range was 0.005–0.2 mg/L for pesticide standard solutions, with determination coefficients from 0.9616 to 0.9999. The method was applied for the analysis of practical and spiked drinking water samples. All results were confirmed by high‐performance liquid chromatography with tandem mass spectrometry. The proposed method was proven to be a commendably rapid screening qualitative and semiquantitative technique for the analysis of pesticide residues in drinking water samples on site.  相似文献   

2.
A rapid and effective method was developed for the analysis of 39 pesticide residues in porcine meat with dual‐layer multiplug filtration cleanup and gas chromatography‐tandem mass spectrometry detection. The cleanup process was performed with columns packed with two layers, namely multiwalled carbon nanotubes, C18 and anhydrous magnesium sulfate (MgSO4) as top layer, while mixture of florisil and MgSO4 as bottom layer. A single‐layer method was tested in parallel, with columns packed with the same amount of absorbents. Extraction conditions and filtration cleanup process were optimized to obtain satisfied method performance. Method linearity was calculated with coefficients of determination more than 0.995. The limits of quantitation were verified with acceptable accuracy at the lowest spiked concentration of 0.01 mg/kg (except pyrimethanil). The recoveries at three fortified levels (0.01, 0.05, and 0.1 mg/kg) in five replicates were between 74 and 118% (except pyrimethanil) with relative standard deviations range from 1 to 16%. The matrix effects were in the range of 1.01 to 2.84. This new method was applied for the analysis of multipesticide residues in market samples of porcine meat. This study showed the dual‐layer multiplug filtration cleanup demonstrated better performance than that with the single‐layer columns in cleanup of porcine meat.  相似文献   

3.
Biological and clinical samples for porphyrin and porphyrinogen analyses by liquid chromatography–tandem mass spectrometry (LC‐MS/MS) are often contaminated with poly(ethylene)glycol (PEG), which complicates the interpretation of mass spectra and characterisation of new porphyrin metabolites. Two contaminating PEG molecules (m/z 833 and m/z 835) were completely separated from uroporphyrin I (m/z 831) by travelling wave ion mobility spectrometry and characterised by tandem mass spectrometry. One of the PEG species (m/z 835) also co‐eluted with uroporphyrinogen I (m/z 837) and was unresolvable by travelling wave ion mobility spectrometry/MS, therefore contaminating the MS/MS mass spectra owing to isotope distribution. These PEG species, with the [M + H]+ ions at m/z at 833 and/or m/z 835, co‐eluted with uroporphyrin I and uroporphyrinogen I by LC‐MS/MS and could be wrongly identified as uroporphomethenes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
This article discusses the separation, analysis and characterisation of intermediates and oxidative by-products of the haem biosynthetic pathway by liquid chromatography and mass spectrometry. Techniques reviewed include high-performance liquid chromatography, ultra-high-performance liquid chromatography, capillary electrophoresis, ion mobility spectrometry, mass spectrometry and tandem mass spectrometry. The emphasis was on the analysis of biological and clinical samples.  相似文献   

5.
The detection frequencies of tefuryltrione, a new type of 4‐hydroxyphenyl‐pyruvate dioxygenase inhibitor herbicide, are rarely reported, probably because of the paucity of analytical methods. Herein, an effective and sensitive analytical method has been developed to detect tefuryltrione in vegetables (tomato and cucumber), cereals (rice and corn), soil, and water by ultra high performance liquid chromatography coupled with tandem mass spectrometry. Comparisons of the performances of dispersive solid‐phase extraction and multiplug filtration cleanup methods were carried out for tefuryltrione in complex matrices. Extraction solvents and purification sorbents were further optimized for dispersive solid‐phase extraction. Tefuryltrione was analyzed with electrospray ionization in the positive mode within 2.0 min. Mean recoveries for tefuryltrione were 75.4–108.9% with relative standard deviations less than 11.0% at three fortification levels (10, 100, 500 μg/kg) in the sample matrixes. Limits of quantification ranged from 0.70 to 5.12 μg/kg, and an excellent linearity (R 2 ≥ 0.9902) was obtained for tefuryltrione at concentrations of 5–1000 μg/L. The results showed that the developed dispersive solid‐phase extraction method could serve as an effective, sensitive, and robust method for routine monitoring of tefuryltrione residue in plants and environmental samples.  相似文献   

6.
The development of new strategies for the analysis of nucleic acids has gained momentum due to the increased interest in using these biomolecules as drugs or drug targets. The application of new mass spectrometry ion activation techniques and the optimization of separation methods including liquid chromatography, capillary electrophoresis, and ion mobility have allowed more detailed characterization of nucleic acids and oligonucleotide therapeutics including confirmation of sequence, localization of modifications and interaction sites, and structural analysis as well as identification of failed sequences and degradation products. This review will cover tandem mass spectrometry methods as well as the recent developments in liquid chromatography, capillary electrophoresis, and ion mobility coupled to mass spectrometry for the analysis of nucleic acids and oligonucleotides.  相似文献   

7.
In this study, a screening and confirmation method for the determination of l ‐hydroxyproline (Hyp) as a target compound in milk and dairy products using high‐performance liquid chromatography with tandem mass spectrometry was developed. The samples were lyophilized after acidic hydrolysis, followed by cleanup with graphitized carbon black to remove pigments. Hyp was separated by a hydrophilic interaction chromatographic column and analyzed by high‐performance liquid chromatography with tandem mass spectrometry working with multiple reaction monitoring mode using an electrospray ionization interface in a positive‐ion mode. Average recoveries in spiked milk and dairy products ranged from 68.0 to 101.1% with relative standard deviations between 2.0 and 11.7% (n = 7). A reagent‐matched standard calibration curve was used for quantification of Hyp, with linear correlation coefficient (R2) > 0.99 in the concentration range of 0.1–100 μg/mL. The LOQs were from 0.25 to 5 mg/kg, which were usually sufficient to verify the Hyp in samples. The confirmation concentration of Hyp ranged from 10 to 50 mg/kg.  相似文献   

8.
Ultra performance liquid chromatography (UPLC) when coupled to ion mobility (IMS)/orthogonal acceleration time of flight mass spectrometry is a suitable technique for analyzing complex mixtures such as the black tea thearubigins. With the aid of this advanced instrumental analysis, we were able to separate and identify different isomeric components in the complex mixture which could previously not be differentiated by a conventional high performance liquid chromatography/tandem mass spectrometry. In this study, the difference between isomeric structures theasinensins, proanthocyanidins B‐type and rutin (quercetin‐3O‐rutinoside) were studied, and these are present abundantly in many botanical sources. The differentiation between these structures was accomplished according to their acquired mobility drift times differing from the traditional investigations in mass spectrometry, where calculation of theoretical collisional cross sections allowed assignment of the individual isomeric structures. The present work demonstrates UPLC–IMS‐MS as an efficient technology for isolating and separating isobaric and isomeric structures existing in complex mixtures discriminating between them according to their characteristic fragment ions and mobility drift times. Therefore, a rational assignment of isomeric structures in many phenolic secondary metabolites based on the ion mobility data might be useful in mass spectrometry‐based structure analysis in the future. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A multiclass, multiresidue determination method is reported for the detection of ten veterinary drugs, including scopolamine, metoclopramide, acriflavine, berberine, tripelennamine, diphenhydramine, acrinol, triamcinolone, loperamide, and roxithromycin in pork, milk, and eggs. The method involves a simple extraction using 0.1% formic acid in acetonitrile, followed by defatting with n‐hexane, centrifugation, and filtration prior to liquid chromatography with tandem mass spectrometric analysis. As ion suppression and enhancement effects are reported, matrix‐matched calibrations are used for quantification, with determination coefficients ≥0.9765. For the majority of the tested analytes, the intra‐ and interday accuracy (expressed as recovery %) range from 70.6 to 94.6% and from 70.1 to 93.3%, respectively, and the precision (expressed as relative standard deviation) ranges from 0.5 to 19.8% and from 2.8 to 18.4% in all matrices. The limits of quantification range between 0.5 and 10 ng/g. The validated tandem mass spectrometry method is successfully applied to market samples; the target analytes are not detected in any of the tested samples. In terms of accuracy, no extract cleanup is deemed necessary. The developed method is feasible for the simultaneous detection of the tested analytes in pork, milk, and eggs.  相似文献   

10.
We describe a new methodology for the simultaneous determination of the endocrine‐disrupting herbicides (acetochlor, alachlor, amitrole, and atrazine), fungicides (carbendazim, triadimefon, penconazole, and propiconazole), and insecticides (carbaryl and carbofuran) in fish samples followed by high‐performance liquid chromatography with tandem mass spectrometry. Samples were extracted and purified using the pass‐through cleanup approach. The recoveries of the pesticides were in the range 71.8–116.5%, with relative standard deviations lower than 15.28%. Limits of quantitation were in the range of 0.03–2.50 μg/kg. Validation results on linearity, accuracy, and precision, as well as on application to the analysis of the endocrine‐disrupting pesticides in 20 fish samples, demonstrated the applicability to screen the presence of pesticides in fish.  相似文献   

11.
An in vivo study of efavirenz metabolites in rats and human patients with ultra high performance liquid chromatography coupled with quadrupole time‐of‐flight tandem mass spectrometry combined with MetabolitePilotMT software is reported for the first time. Considering the polarity differences between the metabolites, solid‐phase extraction and protein precipitation were both applied as a part of the sample preparation method. The structures of the metabolites and their fragment ions were identified or tentatively characterized based on the accurate mass and MS2 data. As a result, a total of 15 metabolites, including 11 from rat samples and 13 from human samples, were identified or tentatively characterized. Two metabolites and several new metabolism pathways are reported for the first time. This study provides a practical approach for identifying complicated metabolites through the rapid and reliable ultra high performance liquid chromatography coupled with quadrupole time‐of‐flight tandem mass spectrometry technique, which could be widely used for the investigation of drug metabolites.  相似文献   

12.
The hepatic cytochrome P450 enzymes play a central role in the biotransformation of endogenous and exogenous substances. A sensitive high‐throughput liquid chromatography with tandem mass spectrometry assay was developed and validated for the simultaneous quantification of the products of ten metabolic reactions catalyzed by hepatic cytochrome P450 enzymes. After the substrates were incubated separately, the samples were pooled and analyzed by liquid chromatography with tandem mass spectrometry using an electrospray ionization source in the positive and negative ion modes. The method exhibited linearity over a broad concentration range, insensitivity to matrix effects, and high accuracy, precision, and stability. The novel method was successfully applied to study the kinetics of phenacetin‐O deethylation, coumarin‐7 hydroxylation, bupropion hydroxylation, taxol‐6 hydroxylation, omeprazole‐5 hydroxylation, dextromethorphan‐O demethylation, tolbutamide‐4 hydroxylation, chlorzoxazone‐6 hydroxylation, testosterone‐6β hydroxylation, and midazolam‐1 hydroxylation in rat liver microsomes.  相似文献   

13.
Oil samples from Recôncavo basin (NE Brazil), previously analyzed by traditional techniques such as gas chromatography coupled to tandem mass spectrometry, were evaluated using comprehensive two‐dimensional gas chromatography coupled to quadrupole mass spectrometry and comprehensive two‐dimensional gas chromatography coupled to tandem mass spectrometry along with simplified methods of samples preparation to evaluate the differences and advantages of these analytical techniques to better understand the development of the organic matter in this basin without altering the normal distribution of the compounds in the samples. As a result, the geochemical parameters calculated by comprehensive two‐dimensional gas chromatography coupled to tandem mass spectrometry described better the origin, maturity, and biodegradation of both samples probably by increased selectivity, resolution, and sensitivity inherent of the multidimensional technique. Additionally, the detection of the compounds such as, the C(14α‐) homo‐26‐nor‐17α‐hopane series, diamoretanes, nor‐spergulanes, C19–C26 A‐nor‐steranes and 4α‐methylsteranes resolved and detected by comprehensive two‐dimensional gas chromatography coupled to tandem mass spectrometry were key to classify and differentiate these lacustrine samples according to their maturity and deposition conditions.  相似文献   

14.
Two methods based on liquid chromatography–tandem mass spectrometry were developed for the determination of ten aminoglycosides (streptomycin, dihydrostreptomycin, spectinomycin, apramycin, paromomycin, kanamycin A, gentamycin C1, gentamycin C2/C2a, gentamycin C1a, and neomycin B) in kidney samples from food‐producing animals and in honey samples. The methods involved extraction with an aqueous solution (for the kidney samples) or sample dissolution in water (for the honey samples), solid‐phase extraction with a weak cation exchange cartridge and injection of the eluate into a liquid chromatography–tandem mass spectrometry system. A zwitterionic hydrophilic interaction chromatography column was used for separation of aminoglycosides and a triple quadrupole mass analyzer was used for detection. The methods were validated according to Decision 2002/657/EC. The limits of quantitation ranged from 2 to 125 μg/kg in honey and 25 to 264 μg/kg in the kidney samples. Interday precision (RSD%) ranged from 6 to 26% in honey and 2 to 21% in kidney. Trueness, expressed as the percentage of error, ranged from 7 to 20% in honey and 1 to 11% in kidney.  相似文献   

15.
An ion mobility quadrupole time‐of‐flight mass spectrometry‐based pesticide suspect screening methodology was developed and validated covering 20 plant‐derived food matrices deriving from six commodity groups of different complexity according to the actual European Commission document SANTE/11813/2017 applying a QuEChERS sample preparation protocol. The method combines ultra‐performance liquid chromatography, traveling wave ion mobility, and quadrupole time‐of‐flight mass spectrometry. Besides the determination of the physicochemical property collision cross‐section and the establishment of a corresponding scientific suspect screening database comprising 280 pesticides for several pesticides, different protomers, sodium adducts, as well as dimers were identified in ion mobility spectrometry traces. Additionally, collision cross‐section values were included in the validation requirements regarding chromatography and mass spectrometry for the detection of pesticides. A collision cross‐section value window was analyzed within a tolerable error of ±2%. For this cross‐matrix validation, screening detection limits were determined at concentration levels of 0.100 mg/kg (84% of the original pesticide scope), 0.010 mg/kg (56%), and 0.001 mg/kg (21%). By application of ion mobility spectrometry, the compound identification was improved due to independence of commodity of concern and concentration levels of analyte molecules, as false assignments are reduced by application of a collision cross‐section range.  相似文献   

16.
Adulterated products are continuously detected in society and cause problems. In this study, we developed and validated a method for determining synthetic sedative‐hypnotics and sleep inducers, including barbital, benzodiazepam, zolpidem, and first‐generation antihistamines, in adulterated products using Quadrupole‐Orbitrap mass spectrometry and ultrahigh performance liquid chromatography with tandem mass spectrometry. In Quadrupole‐Orbitrap mass spectrometry analysis, target compounds were confirmed using a combination of retention time, mass tolerance, mass accuracy, and fragment ions. For quantification, several validation parameters were employed using ultrahigh performance liquid chromatography with tandem mass spectrometry. The limit of detection and limit of quantitation was 0.05–53 and 0.17–177 ng/mL, respectively. The correlation coefficient for linearity was more than 0.995. The intra‐ and interassay accuracies were 86–110 and 84–111%, respectively. Their precision values were evaluated as within 4.0 (intraday) and 10.7% (interday). Mean recoveries of target compounds in adulterated products ranged from 85 to 116%. The relative standard deviation of stability was less than 10.7% at 4°C for 48 h. The 144 adulterated products obtained over 3 years (2014–2016) from online and in‐person vendors were tested using established methods. After rapidly screening with Quadrupole‐Orbitrap mass spectrometry, the detected samples were quantified using ultrahigh performance liquid chromatography with tandem mass spectrometry. Two of them were adulterated with phenobarbital.  相似文献   

17.
A novel heart‐cutting two‐dimensional liquid chromatography coupled with tandem mass spectrometry method was developed for quantitative analysis of pendimethalin residue in tobacco. The strategy of reversed phase liquid chromatography coupled with another reversed‐phase liquid chromatography was employed for high column efficiency and excellent compatibility of mobile phase. In the first dimensional chromatography, a cyano column with methanol/water as the eluent was applied to separate pendimethalin from thousands of interference components in tobacco. By heart‐cutting technique, which effectively removed interference components, the target compound was cut to the second dimensional C18 column for further separation. The pendimethalin residue was finally determined by the tandem mass spectrometry under multiple reaction monitoring reversed‐phase liquid chromatography mode. Sample pretreatment of the new method was simplified, involving only extraction and filtration. Compared with traditional methodologies, the new method showed fairly high selectivity and sensitivity with almost no matrix interference. The limit of quantitation for pendimethalin was 1.21 ng/mL, whereas the overall recoveries ranged from 95.7 to 103.3%. The new method has been successfully applied to non‐stop measure of 200 real samples, without contamination of ion source. Detection results of the samples agreed well with standard method.  相似文献   

18.
For the determination of trace residues of tetracycline antibiotics in fatty food samples, selective pressurized liquid extraction coupled with high‐performance liquid chromatography and tandem mass spectrometry was applied in this study. Copper(II) isonicotinate was first used as online cleanup adsorbent in the selective pressurized liquid extraction process. The adsorbent to sample ratio, extraction temperature, extraction time, and recycle times, etc. were optimized. The tetracyclines in food samples of pork, chicken meat, and clam meat were detected by liquid chromatography with tandem mass spectrometry. Tetracycline was found at levels of 0.32 and 0.53 μg/g and oxytetracycline was found at 0.14 and 0.21 μg/g in chicken meat and clam meat, respectively, while chlorotetracycline and deoxytetracycline were below the detection limit. The detection limit (S/N = 3) for these four tetracyclines were from 0.2 to 3.3 ng/g, the recoveries were from 75.8 to 110.5%, and relative standard deviations were from 5.5 to 13.6%. Copper(II) isonicotinate showed a higher purification capacity than other cleanup adsorbents for extraction of antibiotics in fatty food and the recovery showed predominance compared with a pressurized liquid extraction method without adsorbent. The study demonstrated that copper(II) isonicotinate would be a promising cleanup adsorbent in pressurized liquid extraction for the analysis of trace organic pollutants in complicated samples.  相似文献   

19.
A quantitative method for the simultaneous determination of octylphenol, nonylphenol and the corresponding ethoxylates (1 to 5) in biota is presented. Extraction methods were developed for egg and fish matrices based on accelerated solvent extraction followed by a solid-phase extraction cleanup, using octadecylsilica or aminopropyl cartridges. Identification and quantitation were accomplished by liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) and compared to the traditional liquid chromatography with fluorescence spectroscopy detection. LC-MS-MS provides high sensitivity and specificity required for these complex matrices and an accurate quantitation with the use of 13C-labeled internal standards. Quantitation limits by LC-MS-MS ranged from 4 to 12 ng/g in eggs, and from 6 to 22 ng/g in fish samples. These methods were successfully applied to osprey eggs from the Chesapeake Bay and fish from the Great Lakes area. Total levels found in osprey egg samples were up to 18 ng/g wet mass and as high as 8.2 microg/g wet mass in the fish samples.  相似文献   

20.
The effects of different cleanup procedures in removing high‐molecular‐mass lipids and natural colorants from oil‐crop extracts, including dispersive solid‐phase extraction, low‐temperature precipitation and gel permeation chromatography, were studied. The pigment removal, lipid quantity, and matrix effects of the three cleanup methods were evaluated. Results indicated that the gel permeation chromatography method is the most effective way to compare the dispersive solid‐phase extraction and low‐temperature precipitation. Pyraclostrobin and epoxiconazole applied extensively in oil‐crop production were selected as typical pesticides to study and a trace analytical method was developed by gel permeation chromatography and ultra high performance liquid chromatography with tandem mass spectrometry. Average recoveries of the target pesticides at three levels (10, 50, and 100 μg/kg) were in the range of 74.7–96.8% with relative standard deviation values below 9.2%. The limits of detection did not exceed 0.46 μg/kg, whereas the limits of quantification were below 1.54 μg/kg and much lower than maximum residue limit in all matrices. This study may provide the essential data for optimizing the analytical method of pesticides in oil‐crop samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号