首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
To characterize the preclinical plasma pharmacokinetics of entrectinib, a reproducible and precise assay is necessary. In this study, we developed and validated a simple ultra‐performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method for the measurement of entrectinib using carbamazepine as the internal standard in rat plasma. Sample preparation was a simple protein precipitation with acetonitrile, then entrectinib was eluted on an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm) using a gradient elution with a mobile phase composed of acetonitrile (A) and 0.1% formic acid in water (B). Detection was achieved using multiple‐reaction monitoring in positive ion electrospray ionization mode. The method showed good linearity over the concentration range of 1–250 ng/mL (r2 > 0.9951). The intra‐ and inter‐day precision was determined with the values of 6.3–12.9 and 2.6–6.9%, respectively, and accuracy values of 0.5–11.6%. Matrix effect, extraction recovery, and stability data all met the acceptance criteria of US Food and Drug Administration guidelines for bioanalytical method validation. The method was successfully applied to a pharmacokinetic study. In this study, we developed the complete validated method for the quantification of entrectinib in rat plasma.  相似文献   

2.
A rapid, sensitive and rugged solid‐phase extraction ultra performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method was developed for determination of paroxetine in human plasma. The procedure for sample preparation includes simple SPE extraction procedure coupled with Hypersil Gold C18 column (100 mm ? 2.1 mm, i.d., 1.9 μm) with isocratic elution at a flow‐rate of 0.350 mL/min and fluoxetine was used as the internal standard. The analysis was performed on a triple‐quadrupole tandem mass spectrometer by multiple reactions monitoring mode via electrospray ionization. Using 500 μL plasma, the methods were validated over the concentration range 0.050–16.710 ng/mL for paroxetine, with a lower limit of quantification of 0.050 ng/mL. The intra‐ and inter‐day precision and accuracy of the quality control samples were within 10.0%. The recovery was 69.2 and 74.4% for paroxetine and fluoxetine respectively. Total run time was only 1.9 min. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A rapid, sensitive, and accurate ultra flow liquid chromatography tandem mass spectrometry (UFLC–MS/MS ) method was developed and validated for simultaneous quantitation of glycyrrhetic acid and puerarin in plasma derived from healthy and alcoholic liver injury rats. Plasma samples from healthy and model rats were deproteinated with methanol using liquiritin as an internal standard. Chromatography separation was performed by a Waters BEH (ethylene-bridged hybrid) C18 column (2.1 × 50 mm; 1.7 μm) using a gradient elution from acetonitrile and water (containing 0.1% formic acid) and at a flow rate of 0.4 mL/min. Quantitation was performed on a Triple Quad 4500 tandem mass spectrometer coupled with an electrospray ionization source in negative multiple reaction monitoring mode. Specificity, carryover, dilution integrity, recovery, linearity, precision and accuracy, matrix effect, and stability were within acceptable limits. The newly established method was successfully applied to a pharmacokinetics study to investigate glycyrrhetic acid and puerarin in healthy and alcoholic liver injury rats.  相似文献   

4.
An ultra high performance liquid chromatography coupled to triple quadrupole tandem mass spectrometry method has been established to evaluate the variations of multiple components of Chinese herbal preparations, Jiao‐ai decoction and Si‐wu decoction, through the simultaneous determination of eight major active compounds with a huge difference in the level of content. Chromatographic separation was achieved on a Waters Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm) with a mobile phase consisting of acetonitrile (0.1% formic acid) and water (0.1% formic acid) under gradient elution. A triple quadrupole tandem mass spectrometer was operated in positive and negative ionization modes, respectively, with multiple reaction monitoring for the detection of the eight compounds. All calibration curves showed excellent linear regressions (r > 0.99) within the test range. The precision, repeatability, and stability of the eight compounds were below 5.0% in terms of relative standard deviation. The recoveries were 97.0–102.4% with a relative standard deviation of 1.21–3.65% for all samples. In conclusion, a rapid, sensitive, precise, accurate, and reliable method has been developed for the simultaneous detection of eight active compounds in the pharmaceutical samples of Jiao‐ai decoction and Si‐wu decoction, which can be applied for the multicomponent comparison and further quality control.  相似文献   

5.
A simple, novel, specific, rapid and reproducible ultra‐performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for the determination of hydroxysafflor yellow A (HSYA) in biological fluids (plasma, urine and cerebrospinal fluid) of patients with traumatic brain injury after intravenous injection of Xuebijing (XBJ). Liquid–liquid extraction was performed, and separation was carried out on an Acquity UPLC? BEH C18 column, with gradient elution using a mobile phase composed of methanol and 0.1% formic acid at a flow rate of 0.3 mL/min. A triple quadrupole tandem mass spectrometer with electrospray ionization was used for the detection of HSYA. The mass transition followed was m/z 611.0 → 491. The retention time was less than 3.0 min. The calibration curve was linear in the concentration range from 2 to 6125 ng/mL for cerebrospinal fluid, plasma and urine. The intra‐ and inter‐day precisions were <10%, and the relative standard deviation of recovery was <15% for HSYA in biological matrices. The method was successfully applied for the first time to quantify HSYA in the biological fluids (especially in cerebrospinal fluid) of patients with traumatic brain injury following intravenous administration of XBJ. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
A rapid and effective method was developed for the qualitative and quantitative analysis of the major chemical constituents in Angelicae pubescentis radix by ultra high performance liquid chromatography with photodiode array detection and quadrupole time‐of‐flight tandem mass spectrometry. The chromatographic separation was achieved on an ACQUITY UHPLC BEH C18 column (2.1 × 100 mm, 1.7 μm). Nine phenolic acids, 30 coumarins, bisabolangelone, and adenosine were identified by quadrupole time‐of‐flight tandem mass spectrometry. All calibration curves exhibited good linearity (r > 0.9996) within the linear ranges. The relative standard deviation calculated for intraday and interday precision, stability, and accuracy were <5%. The mean recovery ranged from 95.8 to 106%. The overall limits of detection and quantification were 0.025–0.160 and 0.100–0.560 μg/mL, respectively. Discriminant analysis was investigated as a method for evaluating the quality of the samples with 100% correction in their classification. The results demonstrated that the developed method could successfully be used to differentiate samples from different regions and could be a helpful tool for detection and confirmation of the quality of traditional Chinese medicines.  相似文献   

7.
A highly sensitive, rapid and specific ultrahigh‐performance liquid chromatography, coupled to negative electrospray ionization high‐resolution tandem mass spectrometry, method was developed and validated in order to investigate the absorption of dietary oleuropein (OE) in human subjects. Serum samples were collected at predefined time points, after oral administration of an olive leaf extract enriched in OE (204.4 mg OE per capsule) to two subjects. Subsequently, samples were analyzed by the developed method after a simple solid‐phase extraction step. Chromatographic separation was operated with aqueous formic acid, 0.1% (v/v), and acetonitrile following a gradient program at a flow rate of 0.45 mL/min in an RP‐C18 (50 × 2.1 mm, 1.9 μm) column with a total run time of 2.7 min. The method was validated and successfully applied to the determination of OE in human serum, with the pharmacokinetic analysis of the data revealing a biphasic response.  相似文献   

8.
A rapid and sensitive high‐performance liquid chromatography and electrospray tandem mass spectrometry method was developed and validated for estimation of fulvestrant in rabbit plasma using liquid–liquid extraction. The separation and quantification of fulvestrant were achieved by reverse‐phase chromatography on a Sunfire C18 column (50 × 2.1. i.d., 3.5 μm) with isocratic elution at a flow rate of 300 μL/min using norethistrone as an internal standard from 500 μL plasma sample. The method was validated over the concentration range from 0.092 to 16.937 ng/mL with a lower limit of detection of 0.023 ng/mL. The intra‐day and inter‐day accuracy and precision were within 10%. The recovery was 85 and 90% for fulvestrant and norethistrone respectively. The chromatographic run time was only 2.5 min. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
An automated online solid‐phase extraction with liquid chromatography and tandem mass spectrometry method was developed and validated for the detection of clenbuterol, salbutamol, and ractopamine in food of animal origin. The samples from the food matrix were pretreated with an online solid‐phase extraction cartridge by Oasis MCX for <5 min after acid hydrolysis for 30 min. The peak focusing mode was used to elute the target compounds directly onto a C18 column. Chromatographic separation was achieved under gradient conditions using a mobile phase composed of acetonitrile/0.1% formic acid in aqueous solution. Each analyte was detected in two multiple reaction monitoring transitions via an electrospray ionization source in a positive mode. The relative standard deviations ranged from 2.6 to 10.5%, and recovery was between 76.7 and 107.2% at all quality control levels. The limits of quantification of three β‐agonists were in the range of 0.024–0.29 μg/kg in pork, sausage, and milk powder, respectively. This newly developed method offers high sensitivity and minimum sample pretreatment for the high‐throughput analysis of β‐agonist residues.  相似文献   

10.
A rapid and sensitive method for the extraction and determination of four major polyphenolic components in Euphoria longana Lam. seeds is presented for the first time based on matrix solid‐phase dispersion extraction followed by ultra high performance liquid chromatography with hybrid triple quadrupole linear ion trap mass spectrometry. Matrix solid‐phase dispersion method was designed for the extraction of Euphoria longana seed constituents and compared with microwave‐assisted extraction and ultrasonic‐assisted extraction methods. An Ultra high performance liquid chromatography with hybrid triple quadrupole linear ion‐trap mass spectrometry method was developed for quantitative analysis in multiple‐reaction monitoring mode in negative electrospray ionization. The chromatographic separation was accomplished using an ACQUITY UPLC BEH C18 (2.1 mm × 50 mm, 1.7 μm) column with gradient elution of 0.1% aqueous formic acid and 0.1% formic acid in acetonitrile. The developed method was validated with acceptable linearity (r2 > 0.999), precision (RSD ≤ 2.22%) and recovery (RSD ≤ 2.35%). The results indicated that matrix solid‐phase dispersion produced comparable extraction efficiency compared with other methods nevertheless was more convenient and time‐saving with reduced requirements on sample and solvent volumes. The proposed method is rapid and sensitive in providing a promising alternative for extraction and comprehensive determination of active components for quality control of Euphoria longana products.  相似文献   

11.
A high‐throughput and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the determination of flunarizine in human plasma. Liquid–liquid extraction under acidic conditions was used to extract flunarizine and flunarizine‐d8 from 100 μL human plasma. The mean extraction recovery obtained for flunarizine was 98.85% without compromising the sensitivity of the method. The chromatographic separation was performed on Hypersil Gold C18 (50 × 2.1 mm, 3 μm) column using methanol–10 mm ammonium formate, pH 3.0 (90:10, v/v) as the mobile phase. A tandem mass spectrometer (API‐5500) equipped with an electrospray ionization source in the positive ion mode was used for detection of flunarizine. Multiple reaction monitoring was selected for quantitation using the transitions, m/z 405.2 → 203.2 for flunarizine and m/z 413.1 → 203.2 for flunarizine‐d8. The validated concentration range was established from 0.10 to 100 ng/mL. The accuracy (96.1–103.1%), intra‐batch and inter‐batch precision (CV ≤ 5.2%) were satisfactory and the drug was stable in human plasma under all tested conditions. The method was used to evaluate the pharmacokinetics of 5 and 10 mg flunarizine tablet formulation in 24 healthy subjects. The pharmacokinetic parameters Cmax and AUC were dose‐proportional.  相似文献   

12.
An ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed for the simultaneous determination of carvedilol and its pharmacologically active metabolite 4′‐hydroxyphenyl carvedilol in human plasma using their deuterated internal standards (IS). Samples were prepared by solid‐phase extraction using 100 μL human plasma. Chromatographic separation of analytes was achieved on UPLC C18 (50 × 2.1 mm, 1.7 µm) column using acetonitrile‐4.0 mm ammonium formate, pH 3.0 adjusted with 0.1% formic acid (78:22, v/v) as the mobile phase. The multiple reaction monitoring transitions for both the analytes and IS were monitored in the positive electrospray ionization mode. The method was validated over a concentration range of 0.05–50 ng/mL for carvedilol and 0.01‐10 ng/mL for 4′‐hydroxyphenyl carvedilol. Intra‐ and inter‐batch precision (% CV) and accuracy for the analytes varied from 0.74 to 3.88 and 96.4 to 103.3% respectively. Matrix effect was assessed by post‐column analyte infusion and by calculation of precision values (coefficient of variation) in the measurement of the slope of calibration curves from eight plasma batches. The assay recovery was within 94–99% for both the analytes and IS. The method was successfully applied to support a bioequivalence study of 12.5 mg carvedilol tablets in 34 healthy subjects. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
The aim of the present study was to develop a simple, sensitive and accurate liquid chromatography–electrospray ionization tandem mass spectrometry (ESI‐MS/MS) method for the determination of lixivaptan (LIX) in mouse plasma using vildagliptin as the internal standard (IS). A precipitation procedure was used for the extraction of LIX and vildagliptin from mouse plasma. Chromatographic separation of LIX was achieved using a C18 analytical column (50 × 2.1 mm, 1.8 μm) at 25°C. The mobile phase comprised acetonitrile and ammonium formate (10 mm , pH 3.1; 40:60, v /v) pumped at a flow rate of 0.3 mL min−1. A tandem mass spectrometer with an electrospray ionization source was used to perform the assay. Quantification of LIX at m/z 290 → 137 and IS at 154 → 97 was attained through multiple reaction monitoring. The investigated method was authenticated following the bio‐analytical method of validation guidelines of the US Food and Drug Administration. The developed method showed a good linearity over the concentration range from 5 to 500 ng mL−1, and the calibration curve was linear (r = 0.9998). The mean recovery of LIX from mouse plasma was 99.2 ± 0.68%. All validation parameters for LIX were within the levels required for acceptance. The proposed method was effectively used for a pharmacokinetic study of LIX in mouse plasma.  相似文献   

14.
A rapid and sensitive assay based on ultra‐high performance liquid chromatography with electrospray ionization tandem mass spectrometry was established and validated for the simultaneous determination of cichoric acid, chlorogenic acid, quinic acid, and caffeic acid in rat plasma after oral administration of Echinacea purpurea extract using butylparaben as the internal standard. Samples were pretreated by liquid–liquid extraction with ethyl acetate. The separations for analytes were performed on an ACQUITY UPLC HSS C18 column (1.8 μm 2.1 × 100 mm) using a gradient elution program with acetonitrile/10 mM ammonium acetate (pH 5.6) at a flow rate of 0.3 mL/min. The analytes were detected in multiple reaction monitoring mode with negative electrospray ionization. The lower limit of quantification of each analyte was not higher than 10.85 ng/mL. The relative standard deviation of the intraday and interday precisions was less than 14.69%. The relative errors of accuracies were in the range of –13.80 to 14.91%. The mean recoveries for extraction recovery and matrix effect were higher than 80.79 and 89.98%, respectively. The method validation results demonstrated that the proposed method was sensitive, specific, and reliable, which was successfully applied to the pharmacokinetic study of four components after oral administration of Echinacea purpurea extract.  相似文献   

15.
A novel rapid and highly sensitive ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) bioanalytical method was established for the analysis of flibanserin in human plasma. Flibanserin d4 was used as internal standard (IS). Flibanserin and the internal standard (IS) were extracted from the plasma using protein precipitation technique with acetonitrile. A Kinetex C18 (2.6 μm, 2.1 × 50 mm) column was used for chromatographic separation and the mobile phase was a mixture of 20 mm ammonium acetate buffer (pH 4.5)–acetonitrile (50:50, v/v) with an isocratic elution mode and a flow rate of 0.3 mL/min. The analysis was performed on a Xefo TQD Waters mass spectrometer in multiple reaction monitoring mode with a positive electrospray ionization interface. The US Food and Drug Administration guidelines were followed during the bio‐analytical methods validation regarding linearity, precision, accuracy, carryover, selectivity, dilution integrity and stability. The analysis run time was carried out within 2 min over a wide linear concentration range of 5–1000 ng mL?1. Finally, the proposed method was successfully used in a pharmacokinetic study that measured flibanserin concentration in healthy, non‐pregnant female volunteers after a single 100 mg oral dose of flibanserin.  相似文献   

16.
In this study, a liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated to simultaneously determine the anticancer drugs etoposide and paclitaxel in mouse plasma and tissues including liver, kidney, lung, heart, spleen and brain. The analytes were extracted from the matrices of interest by liquid–liquid extraction using methyl tert‐butyl ether–dichloromethane (1:1, v/v). Chromatographic separation was achieved on an Ultimate XB‐C18 column (100 × 2.1 mm, 3 μm) at 40°C and the total run time was 4 min under a gradient elution. Ionization was conducted using electrospray ionization in the positive mode. Stable isotope etoposide‐d3 and docetaxel were used as the internal standards. The lower limit of quantitation (LLOQ) of etoposide was 1 ng/g tissue for all tissues and 0.5 ng/mL for plasma. The LLOQ of paclitaxel was 0.4 ng/g tissue and 0.2 ng/mL for all tissues and plasma, respectively. The coefficients of correlation for all of the analytes in the tissues and plasma were >0.99. Both intra‐ and inter‐day accuracy and precision were satisfactory. This method was successfully applied to measure plasma and tissue drug concentrations in mice treated with etoposide and paclitaxel‐loaded self‐microemulsifying drug‐delivery systems.  相似文献   

17.
A sensitive and selective high‐performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry method has been developed and validated for the simultaneous determination of 25 active constituents, including 21 flavonoids and four phenolic acids in the total flavonoids extract from Herba Desmodii Styracifolii for the first time. Among the 25 compounds, seven compounds including caffeic acid, acacetin, genistein, genistin, diosmetin, diosmin and hesperidin were identified and quantified for the first time in Herba Desmodii Styracifolii. Chromatographic separation was accomplished on a ZORBAX SB‐C18 (250 mm×4.6 mm, 5.0 μm) column using gradient elution of methanol and 0.1‰ acetic acid v/v at a flow rate of 1.0 mL/min. The identification and quantification of the analytes were achieved using negative electrospray ionization mass spectrometry in multiple‐reaction monitoring mode. The method was fully validated in terms of limits of detection and quantification, linearity, precision and accuracy. The results indicated that the developed method is simple, rapid, specific and reliable. Furthermore, the developed method was successfully applied to quantify the 25 active components in six batches of total flavonoids extract from Herba Desmodii Styracifolii.  相似文献   

18.
A simple, specific and sensitive ultra‐performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method was established and validated for simultaneous determination of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid and geniposide in rat plasma using puerarin as an internal standard (IS). Plasma samples were pretreated by a one‐step direct protein precipitation procedure with acetonitrile after acidified using as little as 50 μL plasma. Chromatographic separation was performed on an Acquity BEH C18 column (100 × 2.1 mm, 1.7 µm) at a flow rate of 0.2 mL/min by a gradient elution, using 0.2% acetic acid–methanol as mobile phase. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via electrospray ionization source with negative ion mode. Calibration curves showed good linearity (r > 0.995) over wide concentration ranges. The intra‐ and inter‐day precisions were <15%, and the accuracy was within ±8.0%. The validated method was successfully applied to a pharmacokinetic study of the four bioactive components in rats after intravenous administration of Reduning injection. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
A highly sensitive, rapid assay method has been developed and validated for the analysis of hyperoside in beagle dog plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves extraction of hyperoside and ginsenoside Re (IS) from beagle dog plasma. Chromatographic separation was carried out on an Agilent Zorbax XDB‐C18 (100 × 2.1 mm, 1.8 µm) column by isocratic elution with acetonitrile and water (50:50, v/v) at a flow rate of 0.25 mL/min with a total run time of 2.0 min. The MS/MS ion transitions monitored were 464.4 → 463.4 for hyperoside and 947.12 → 969.60 for IS. Linear responses were obtained for hyperoside ranging from 10 to 5000 ng/mL. The intra‐and inter‐day precisions (RSDs) were <5.38 and 3.39% and the extraction recovery ranged from 94.39 to 100.78% with an RSD <3.82%. Stability studies showed that hyperoside was stable in preparation and analytical process. The results indicated that the validated method was successfully used to determine the concentration–time profiles of hyperoside. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
In this study, a rapid and reliable ultra‐fast liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous determination of eight active ingredients, including astragaloside IV, ononin, tanshinol, protocatechualdehyde, protocatechuic acid, salvianolic acid D, rosmarinic acid and ginsenoside Rg1, in rat plasma. The plasma samples were pretreated by protein precipitation with acetonitrile. Chromatographic separation was performed on a Waters Acquity UPLC® BEH C18 column (1.7 μm particles, 2.1 × 100 mm). The mobile phase consisted of 0.1% aqueous formic acid (A)–acetonitrile with 0.1% formic acid (B) at a flow rate of 0.4 mL/min. Quantification was performed on a triple quadruple tandem mass spectrometry with electrospray ionization by multiple reaction monitoring both in the negative and in the positive ion mode. The lower limit of quantification of tanshinol was 2.0 ng/mL and the others were 5.0 ng/mL. The extraction recoveries, matrix effects, intra‐ and inter‐day precision and accuracy of eight tested components were all within acceptable limits. The validated method was successfully applied to the pharmacokinetic study of the eight active constituents after intragastric administration of three doses (1.0, 3.0, 6.0 g/kg body weight) of Qishen Yiqi Dripping Pills to rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号