共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Functionalized nanoparticles based solid‐phase membrane micro‐tip extraction and high‐performance liquid chromatography analyses of vitamin B complex in human plasma 下载免费PDF全文
Imran Ali Umma Kulsum Zeid A. AL‐Othman Abdulrahman Alwarthan Kishwar Saleem 《Journal of separation science》2016,39(14):2678-2688
Iron nanoparticles were prepared by a green method following functionalization using 1‐butyl‐3‐methylimidazolium bromide. 1‐Butyl‐3‐methylimidazole iron nanoparticles were characterized using FTIR spectroscopy, energy dispersive X‐ray fluorescence, X‐ray diffraction, scanning electron microscopy and transmission electron microscopy. The nanoparticles were used in solid‐phase membrane micro‐tip extraction to separate vitamin B complex from plasma before high‐performance liquid chromatography. The optimum conditions obtained were sorbent (15 mg), agitation time (30 min), pH (9.0), desorbing solvent [water (5 mL) + methanol (5 mL) + sodium hydroxide (0.1 N) + acetic acid (d = 1.05 kg/L, pH 5.5), desorbing volume (10 mL) and desorption time (30 min). The percentage recoveries of all the eight vitamin B complex were from 60 to 83%. A high‐performance liquid chromatography method was developed using a PhE column (250 × 4.6 mm, 5.0 μm) and water/acetonitrile (95:5, v/v; pH 4.0 with 0.1% formic acid) mobile phase. The flow rate was 1.0 mL/min with detection at 270 and 210 nm. The values of the capacity, separation and resolution factor were 0.57–39.47, 1.12–6.00 and 1.84–26.26, respectively. The developed sample preparation and chromatographic methods were fast, selective, inexpensive, economic and reproducible. The developed method can be applied for analyzing these drugs in biological and environmental matrices. 相似文献
3.
Optimized and validated high‐performance liquid chromatography method for the determination of deoxynivalenol and aflatoxins in cereals 下载免费PDF全文
Adriana Skendi Maria N. Irakli Maria D. Papageorgiou 《Journal of separation science》2016,39(8):1425-1432
A simple, sensitive and accurate analytical method was optimized and developed for the determination of deoxynivalenol and aflatoxins in cereals intended for human consumption using high‐performance liquid chromatography with diode array and fluorescence detection and a photochemical reactor for enhanced detection. A response surface methodology, using a fractional central composite design, was carried out for optimization of the water percentage at the beginning of the run (X1, 80–90%), the level of acetonitrile at the end of gradient system (X2, 10–20%) with the water percentage fixed at 60%, and the flow rate (X3, 0.8–1.2 mL/min). The studied responses were the chromatographic peak area, the resolution factor and the time of analysis. Optimal chromatographic conditions were: X1 = 80%, X2 = 10%, and X3 = 1 mL/min. Following a double sample extraction with water and a mixture of methanol/water, mycotoxins were rapidly purified by an optimized solid‐phase extraction protocol. The optimized method was further validated with respect to linearity (R2>0.9991), sensitivity, precision, and recovery (90–112%). The application to 23 commercial cereal samples from Greece showed contamination levels below the legally set limits, except for one maize sample. The main advantages of the developed method are the simplicity of operation and the low cost. 相似文献
4.
Ultrapreconcentration and determination of organophosphorus pesticides in water by solid‐phase extraction combined with dispersive liquid–liquid microextraction and high‐performance liquid chromatography 下载免费PDF全文
Junhua Chen Guangming Zhou Yongli Deng Hongmei Cheng Jie Shen Yi Gao Guilong Peng 《Journal of separation science》2016,39(2):272-278
Solid‐phase extraction coupled with dispersive liquid–liquid microextraction was developed as an ultra‐preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion‐methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid‐phase extraction coupled with dispersive liquid–liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid‐phase extraction coupled with dispersive liquid–liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9–6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples. 相似文献
5.
Simultaneous determination of four trace estrogens in feces,leachate, tap and groundwater using solid–liquid extraction/auto solid‐phase extraction and high‐performance liquid chromatography with fluorescence detection 下载免费PDF全文
Na Liu Yue‐e Shi Mengyan Li Ting‐di Zhang Song Gao 《Journal of separation science》2015,38(20):3494-3501
A simple and selective high‐performance liquid chromatography method coupled with fluorescence detection was developed for the simultaneous measurement of trace levels of four estrogens (estrone, estradiol, estriol and 17α‐ethynyl estradiol) in environmental matrices. For feces samples, solid–liquid extraction was applied with a 1:1 v/v mixture of acetonitrile and ethyl acetate as the extraction solvent. For liquid samples (e.g., leachate and groundwater), hydrophobic/lipophilic balanced automated solid‐phase extraction disks were selected due to their high recoveries compared to conventional C18 disks. Chromatographic separations were performed on a reversed‐phase C18 column gradient‐eluted with a 45:55 v/v mixture of acetonitrile and water. The detection limits were down to 1.1 × 10?2 (estrone), 4.11 × 10?4 (estradiol), 5.2 × 10?3 (estriol) and 7.18 × 10?3 μg/L (17α‐ethynyl estradiol) at excitation/emission wavelengths of 288/310 nm, with recoveries in the range of 96.9 ± 3.2–105.4 ± 3.2% (n = 3). The method was successfully applied to determine estrogens in feces and water samples collected at livestock farms and a major river in Northeast China. We observed relatively high abundance and widespread distribution of all four estrogens in our sample collections, implying the urgency for a comprehensive and intricate investigation of estrogenic fate and contamination in our researched area. 相似文献
6.
Development of coupled ultrasound‐assisted and reversed‐phase dispersive liquid–liquid microextraction before high‐performance liquid chromatography for the sensitive determination of vitamin A and vitamin E in oil samples 下载免费PDF全文
Nasser Goudarzi Sahar Farsimadan Mansour Arab Chamjangali Ghadam Ali Bagherian 《Journal of separation science》2015,38(18):3254-3261
A new approach based on the ultrasound‐assisted reversed‐phase dispersive liquid–liquid microextraction technique is developed for the extraction and determination of vitamin A and vitamin E from oil matrices before high‐performance liquid chromatography analysis. A methodology based on the full factorial design is carried out to choose the significant parameters. Then the significant factors affecting the extraction efficiency including pH, volume of extraction solvent, and volume of disperser solvent are optimized using a Box–Behnken design. After analyzing the results obtained, the optimum conditions were: pH 4.5, 80–20 μL of the ethanol/water solvent mixture as extraction solvent, 110 μL of 1,4‐dioxane as the disperser solvent, and a sonication time of 10 min. For validation of the developed method, the linear dynamic range, repeatability, limit of detection, and recoveries were obtained under the optimum conditions. The detection limits of the method were 1.6 and 2.3 ng/mL for vitamin A and vitamin E, respectively. The extraction recovery percentages for the studied drugs were above 91%, with acceptable relative standard deviation. The proposed methodology was successfully applied for the determination of the vitamins in different oil samples. 相似文献
7.
Simple high‐performance liquid chromatography method for formaldehyde determination in human tissue through derivatization with 2,4‐dinitrophenylhydrazine 下载免费PDF全文
Bilal Yilmaz Ali Asci Kaan Kucukoglu Mevlut Albayrak 《Journal of separation science》2016,39(15):2963-2969
A simple high‐performance liquid chromatography method has been developed for the determination of formaldehyde in human tissue. FA Formaldehyde was derivatized with 2,4‐dinitrophenylhydrazine. It was extracted from human tissue with ethyl acetate by liquid–liquid extraction and analyzed by high‐performance liquid chromatography. The calibration curve was linear in the concentration range of 5.0–200 μg/mL. Intra‐ and interday precision values for formaldehyde in tissue were <6.9%, and accuracy (relative error) was better than 6.5%. The extraction recoveries of formaldehyde from human tissue were between 88 and 98%. The limits of detection and quantification of formaldehyde were 1.5 and 5.0 μg/mL, respectively. Also, this assay was applied to liver samples taken from a biopsy material. 相似文献
8.
Glass slides functionalized by 1‐carboxyethyl‐3‐methylimidazolium chloride for the determination of triazine herbicides in rice using high‐performance liquid chromatography 下载免费PDF全文
Xinpei Li Shigang Wei Ying Sun Qun Sun Li Liang Bo Zhang Huilan Piao Daqian Song Xinghua Wang 《Journal of separation science》2016,39(23):4585-4591
A novel and simple supported ionic‐liquid‐based solid‐phase extraction method for the determination of triazine herbicides in rice was developed. Glass slides were functionalized by an ionic liquid, 1‐carboxyethyl‐3‐methylimidazolium chloride, and were used for the simultaneous extraction of seven triazine herbicides in rice samples. The effects of the type of extraction solvent, the extraction time, the type and volume of loading solvent, and the type of eluting solvent on the extraction efficiency were investigated and optimized. Under the optimum operation conditions, the limits of detection for seven triazine herbicides in rice samples obtained by high‐performance liquid chromatography were 3.16–5.42 ng/g, which were lower than the maximum residue levels established by various organizations. The linear correlation coefficients were higher than 0.9975 in the concentration range of 0.015–1.08 μg/g for the seven triazine herbicides. The recoveries of the seven triazine herbicides at the two concentration levels of 0.15 and 0.45 μg/g are between 82.47 and 104.21%, with relative standard deviations of 0.69–9.19%. The intra‐ and inter‐day (n = 5) precisions for all triazine herbicides at the spiked level of 0.30 μg/g were 1.72–11.71%. 相似文献
9.
Online solid‐phase extraction with high‐performance liquid chromatography and mass spectrometry for the determination of five tannins in traditional Chinese medicine injections 下载免费PDF全文
Meng Sun Yuanyuan Lin Jie Zhang Shaohua Zheng Sicen Wang 《Journal of separation science》2016,39(5):889-894
A rapid analytical method based on online solid‐phase extraction with high‐performance liquid chromatography and mass spectrometry has been established and applied to the determination of tannin compounds that may cause adverse effects in traditional Chinese medicine injections. Different solid‐phase extraction sorbents have been compared and the elution buffer was optimized. The performance of the method was verified by evaluation of recovery (≥40%), repeatability (RSD ≤ 6%), linearity (r2 ≥ 0.993), and limit of quantification (≤0.35 μg/mL). Five tannin compounds, gallic acid, cianidanol, gallocatechin gallate, ellagic acid, and penta‐O‐galloylglucose, were identified with concentrations ranging from 3.1–37.4 μg/mL in the analyzed traditional Chinese medicine injections. 相似文献
10.
Vortex‐assisted liquid–liquid micro‐extraction and high‐performance liquid chromatography for a higher sensitivity methyl methacrylate determination in biological matrices 下载免费PDF全文
Tiago F. A. Sousa Marta C. Aniceto Célia G. Amorim Mariana Souto‐Lopes Daniel Pérez‐Mongiovi Maria C. B. S. M. Montenegro Alberto N. Araújo 《Biomedical chromatography : BMC》2014,28(5):680-685
A vortex‐assisted liquid–liquid micro‐extraction coupled with high‐performance liquid chromatography, with UV–vis, is proposed to pre‐concentrate methyl methacrylate and to improve separation in biological matrices. The use of 1‐octanol as extracting phase, its volume, the need for a dispersant agent, the agitation conditions and the cooling time before phase separation were evaluated. In optimum conditions, enrichment factors of 20 (±0.5) and enrichment recovery of 99% were obtained. The straightforward association of this extraction process with the HPLC method, previously regulated by the International Organization for Standardization, afforded a detection limit of 122 ng/mL and a quantification limit of 370 ng/mL. The within‐batch precision, relative standard deviation, was 3% for a sample with 1.49 µg/mL and 4% for a sample with 13.4 µg/mL. The results showed a between batch‐precision of 21% for experiments performed on five different days, for a sample with a concentration of 1.10 µg/mL in methyl methacrylate. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
11.
《Journal of separation science》2018,41(11):2411-2418
A simple, environmentally benign, and rapid method based on temperature‐controlled liquid–liquid microextraction using a deep eutectic solvent was developed for the simultaneous extraction/preconcentration of diazinon and fenitrothion. The method involved the addition of deep eutectic solvent to the aqueous sample followed by heating the mixture in a 75°C water bath until the solvent was completely dissolved in the aqueous phase. Then, the resultant solution was cooled in an ice bath and a cloudy solution was formed. Afterward, the mixture was centrifuged and the enriched deep eutectic solvent phase was analyzed by high‐performance liquid chromatography with ultraviolet detection for quantification of the analytes. The factors affecting the extraction efficiency were optimized. Under the optimized extraction conditions, the limits of detection for diazinon and fenitrothion were 0.3 and 0.15 μg/L, respectively. The calibration curves for diazinon and fenitrothion exhibited linearity in the concentration range of 1–100 and 0.5–100 μg/L, respectively. The relative standard deviations for five replicate measurements at 10.0 μg/L level of analytes were less than 2.8 and 4.5% for intra‐ and interday assays, respectively. The developed method was successfully applied to the determination of diazinon and fenitrothion in water and fruit juice samples. 相似文献
12.
High performance liquid chromatography method for the determination of meropenem in human plasma 总被引:2,自引:0,他引:2
Summary This paper describes an HPLC method for the determination of meropenem in human plasma. The method uses solid phase extraction
(SPE) of the samples and has good sensitivity, precision and accuracy. The limit of quantification in plasma samples is 0.02
μg mL−1. Calibration curves were linear over a large dynamic range, namely within 0.02–50 μg mL−1. The method was applied to the determination of meropenem levels in patients receiving meropenem, as a single dose or at
steady state. 相似文献
13.
Optimized determination of polybrominated diphenyl ethers by ultrasound‐assisted liquid–liquid extraction and high‐performance liquid chromatography 下载免费PDF全文
A method based on ultrasound‐assisted liquid–liquid extraction and high‐performance liquid chromatography has been optimized for the determination of six polybrominated diphenyl ether congeners. The optimal condition relevant to the extraction was first investigated, more than 98.7 ± 0.7% recovery was achieved with dichloromethane as extractant, 5 min extraction time, and three cycles of ultrasound‐assisted liquid–liquid extraction. Then multiple function was employed to optimize polybrominated diphenyl ether detection conditions with overall resolution and chromatography signal area as the responses. The condition chosen in this experiment was methanol/water 93:7 v/v, flow rate 0.80 mL/min, column temperature 30.0°C. The optimized technique revealed good linearity (R2 > 0.9962 over a concentration range of 1–100 μg/L) and repeatability (relative standard deviation < 6.3%). Furthermore, the detection limit (S/N = 3) of the method were ranged from 0.02 to 0.13 μg/L and the quantification limit (S/N = 10) ranged from 0.07 to 0.35 μg/L. Finally, the proposed method was applied to spiked samples and satisfactory results were achieved. These results indicate that ultrasound‐assisted liquid–liquid extraction coupled with high‐performance liquid chromatography was effective to identify and quantify the complex polybrominated diphenyl ethers in effluent samples. 相似文献
14.
Development and validation of a magnetic solid‐phase extraction with high‐performance liquid chromatography method for the simultaneous determination of amphetamine and methadone in urine 下载免费PDF全文
Arezou Taghvimi Hamed Hamishehkar Mahmoud Ebrahimi 《Journal of separation science》2016,39(12):2307-2312
The simultaneous determination of amphetamine and methadone was carried out by magnetic graphene oxide nanoparticles, a magnetic solid‐phase extraction adsorbent, as a new sample treatment technique. The main factors (the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, the ionic strength of extraction medium, and agitation rate) influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, good linearity was observed in the range of 100–1500 ng/mL for amphetamine and 100–1000 ng/mL for methadone. The method was evaluated for determination of AM and methadone in positive urine samples, satisfactory results were obtained, therefore magnetic solid‐phase extraction can be applied as a novel method for the determination of drugs of abuse in forensic laboratories. 相似文献
15.
Extraction and preconcentration of formaldehyde in water by polypyrrole‐coated magnetic nanoparticles and determination by high‐performance liquid chromatography 下载免费PDF全文
Meysam Safari Yadollah Yamini Elham Tahmasebi Farzad Latifeh 《Journal of separation science》2015,38(19):3421-3427
In this study, a simple and rapid extraction method based on the application of polypyrrole‐coated Fe3O4 nanoparticles as a magnetic solid‐phase extraction sorbent was successfully developed for the extraction and preconcentration of trace amounts of formaldehyde after derivatization with 2,4‐dinitrophenylhydrazine. The analyses were performed by high‐performance liquid chromatography followed by UV detection. Several variables affecting the extraction efficiency of the formaldehyde, i.e., sample pH, amount of sorbent, salt concentration, extraction time and desorption conditions were investigated and optimized. The best working conditions were as follows: sample pH, 5; amount of sorbent, 40 mg; NaCl concentration, 20% w/v; sample volume, 20 mL; extraction time, 12 min; and 100 μL of methanol for desorption of the formaldehyde within 3 min. Under the optimal conditions, the performance of the proposed method was studied in terms of linear dynamic range (10–500 μg/L), correlation coefficient (R2 ≥ 0.998), precision (RSD% ≤ 5.5) and limit of detection (4 μg/L). Finally, the developed method was successfully applied for extraction and determination of formaldehyde in tap, rain and tomato water samples, and satisfactory results were obtained. 相似文献
16.
Ultrasound‐assisted emulsification microextraction coupled with high‐performance liquid chromatography for the simultaneous determination of fragrance allergens in cosmetics and water 下载免费PDF全文
Jessica Pérez‐Outeiral Esmeralda Millán Rosa Garcia‐Arrona 《Journal of separation science》2015,38(9):1561-1569
A simple, inexpensive, and environmentally friendly method based on ultrasound‐assisted emulsification microextraction followed by solidification of floating organic drop and high‐performance liquid chromatography coupled to diode array detection was developed for the simultaneous determination of 18 potentially allergenic fragrance substances. Several parameters affecting the microextraction process were investigated in detail by the “one‐variable‐at‐a‐time” approach. Optimal conditions were the following: 50 μL of 2‐dodecanol as extraction solvent, 10 mL of sample containing 150 g/L of salt, and 5 min of sonication at 35°C. Under the optimized conditions, method showed good linearity in the selected ranges, with squared correlation coefficients ranging from 0.948 to 0.999. Limits of detection ranged from 0.001 to 0.154 μg/mL and enrichment factors from 9 to 237. Precision of the method, expressed as relative standard deviation, was checked at two levels obtaining good results (3.3–14.4%). Recovery studies were made in baby bath water and in eau de cologne showing acceptable accuracy. Finally, the developed method was successfully applied to different commercial cosmetic and water samples. The most commonly found analyte was linalool followed by cinnamal and lilial. Most of the analyzed samples contained at least one of the target compounds. 相似文献
17.
Magnetic molecularly imprinted polymer for the efficient and selective preconcentration of diazinon before its determination by high‐performance liquid chromatography 下载免费PDF全文
Fahimeh Zare Mehrorang Ghaedi Ali Daneshfar Abbas Ostovan 《Journal of separation science》2015,38(16):2797-2803
A molecularly imprinted polymer was selectively applied for solid‐phase extraction and diazinon residues enrichment before high‐performance liquid chromatography. Diazinon was thermally copolymerized with Fe3O4@polyethyleneglycol nanoparticles, methacrylic acid (functional monomer), 2‐hydroxyethyl methacrylate (co‐monomer), and ethylene glycol dimethacrylate (cross‐linking monomer) in the presence of acetonitrile (porogen) and 2,2‐azobisisobutyronitrile (initiator). Then, the imprinted diazinon was reproducibly eluted with methanol/acetic acid (9:1, v/v). The sorbent particles were characterized by X‐ray diffraction, Fourier transform infrared spectroscopy, and scanning electron microscopy. The comprehensive study of variables through experimental design showed that the maximum performance was achieved under these conditions: pH 7, 10 mL sample volume, 15 mg sorbent, 10 min vortex time, 5 min ultrasonic time, 200 μL methanol/acetic acid (9:1, v/v) as eluent, and 5 min desorption time. Under optimized conditions, the molecularly imprinted polymer solid‐phase extraction method demonstrated a linear range (0.02–5 g/mL), a correlation coefficient of 0.997, and 0.005 g/mL detection limit. 相似文献
18.
《Biomedical chromatography : BMC》2018,32(2)
A simple analytical method for simultaneous determination of phytosterols, cholesterol and squalene in lipid emulsions was developed owing to increased interest in their clinical effects. Method development was based on commonly used stationary (C18, C8 and phenyl) and mobile phases (mixtures of acetonitrile, methanol and water) under isocratic conditions. Differences in stationary phases resulted in peak overlapping or coelution of different peaks. The best separation of all analyzed compounds was achieved on Zorbax Eclipse XDB C8 (150 × 4.6 mm, 5 μm; Agilent) and ACN–H2O–MeOH, 80:19.5:0.5 (v/v/v). In order to achieve a shorter time of analysis, the method was further optimized and gradient separation was established. The optimized analytical method was validated and tested for routine use in lipid emulsion analyses. 相似文献
19.
Ali Aghaei Mehdi Erfani Jazi Todd E Mlsna Mohammad Ali Kamyabi 《Journal of separation science》2019,42(18):3002-3008
Electromembrane extraction was used with high‐performance liquid chromatography for preconcentration and determination of ampicillin residues in cow milk. Ampicillin is transferred from an aqueous solution through a thin layer containing octan‐1‐ol, silver nanoparticles, and reduced graphene oxide which serves as a supported liquid membrane. Inside the fiber impregnated with supported liquid membrane mixture was filled 10 µL of an acceptor phase. Experimental parameters were optimized for extraction efficiency of ampicillin. Under the optimized conditions, the proposed method provided acceptable linear range (2–100 µg/L), satisfactory repeatability (RSD% < 7.1), low limit of detection (0.6 µg/L), and a high enrichment factor (295) corresponding to extraction recovery of 37%. Consequently, the proposed method was successfully applied for the determination of ampicillin residues in different cow milks. 相似文献
20.
Vortex‐assisted liquid–liquid microextraction using a low‐toxicity solvent for the determination of five organophosphorus pesticides in water samples by high‐performance liquid chromatography 下载免费PDF全文
Guilong Peng Qiang He Daniel Mmereki Guangming Zhou Weiliang Pan Li Gu Leilei Fan Xiaohui Tang Junhua Chen Yufeng Mao 《Journal of separation science》2015,38(20):3487-3493
Vortex‐assisted liquid–liquid microextraction followed by high‐performance liquid chromatography with UV detection was applied to determine Isocarbophos, Parathion‐methyl, Triazophos, Phoxim and Chlorpyrifos‐methyl in water samples. 1‐Bromobutane was used as the extraction solvent, which has a higher density than water and low toxicity. Centrifugation and disperser solvent were not required in this microextraction procedure. The optimum extraction conditions for 15 mL water sample were: pH of the sample solution, 5; volume of the extraction solvent, 80 μL; vortex time, 2 min; salt addition, 0.5 g. Under the optimum conditions, enrichment factors ranging from 196 to 237 and limits of detection below 0.38 μg/L were obtained for the determination of target pesticides in water. Good linearities (r > 0.9992) were obtained within the range of 1–500 μg/L for all the compounds. The relative standard deviations were in the range of 1.62–2.86% and the recoveries of spiked samples ranged from 89.80 to 104.20%. The whole proposed methodology is simple, rapid, sensitive and environmentally friendly for determining traces of organophosphorus pesticides in the water samples. 相似文献