首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
A platform for the pharmacokinetic study of multiple constituent traditional Chinese medicine was developed and validated. An HPLC/ESI/MS method was employed for the simultaneous determination of panax notoginsenoside R1, ginsenoside Rg1, Rd, Re and Rb1 in rat plasma. After the addition of digoxin as an internal standard (IS), rat plasmas were extracted with n-butanol saturated with pure water and all analytes were separated on a reversed-phased C(18) column with a mobile phase of acetonitrile-water (0.5 mM ammonium chloride) and pumped at a flow rate of 0.2 mL/min. Analytes were determined in a single quadrupole mass spectrometer using an electrospray ionization source. HPLC/ESI/MS was performed in the selected-ion monitoring mode with the chlorinated adducts of molecular ions [M + Cl]( -) at m/z 967.75, 835.80, 981.80, 981.80, 1143.65 and 815.40 for R1, Rg1, Rd, Re, Rb1 and digoxin, respectively. The method showed excellent linearity over the concentration range 3.03-775.00 ng/mL (r(2) = 0.9994) for R1, 4.00-1025.00 ng/mL (r(2) = 0.9991, 0.9988, 0.9991) for Rg1, Rd and Re, respectively, and 2.77-710.00 ng/mL for Rb1 (r(2) = 0.9990). The low limit of quantification was 3.03, 4.00, 4.00, 4.00 and 2.77 ng/mL for R1, Rg1, Rd, Re and Rb1, respectively, with S/N > 10. The intra- and inter-day precisions were below 12.00% and the accuracy was between -2.31 and +4.43% for all analytes. The extract recoveries of analytes were from 67.47 to 94.18%. All analytes were stable in rat plasma after storage for 12 h at ambient temperature, at 4 degrees C for 12 h in the sample pool, at -20 degrees C for 4 weeks and at -20 degrees C for three thaw-freeze cycles. The HPLC/ESI/MS technique provided an excellent method for the simultaneous quantification of R1, Rg1, Rd, Re and Rb1 in rat plasma and was successfully applied to the pharmacokinetic study of a multiple-constituent traditional Chinese medicine, total panax notoginsenoside (Xuesaitong injection).  相似文献   

2.
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method has been developed and validated for simultaneous quantification of ginsenosides Rg1, Re and notoginsenoside R1 in human plasma. Chromatography was performed on Capcell Pak C18 MG II column using a binary gradient using mobile phase A (5 mm ammonium formate solution) and B (methanol, containing 5 mm ammonium formate) at a flow rate of 0.3 mL/min. The entire chromatographic run time was 3.2 min. Quantification was achieved using multiple reaction monitoring in positive mode using API 3000. This method was validated in terms of specificity, linearity, precision, accuracy, matrix effect and stability. The calibration curves were linear in the concentration range of 0.020–5.00 ng/mL for ginsenosides Rg1, Re and notoginsenoside R1. The lower limit of quantification (LLOQ) of this method was 0.020 ng/mL. The intra‐run and inter‐run precision values were within 12.31% for ginsenoside Rg1, 14.13% for ginsenoside Re and 11.46% for notoginsenoside R1 at their LLOQ levels. The samples were stable under all tested conditions. This method was successfully applied to study the pharmacokinetics of ginsenoside Rg1 and notoginsenoside R1 in 24 healthy volunteers following oral administration of 200 mg Sanqi Tongshu Enteric‐Pellets Capsule.  相似文献   

3.
A rapid, simple and specific method for estimation of anastrazole in human plasma was validated using letrozole as internal standard. The analyte and internal standard were extracted from plasma using simple solid‐phase extraction. The compound were separated on a reverse‐phase column with an isocratic mobile phase consisting of 0.1% formic acid in water and acetonitrile (12 : 88, v/v) and detected by tandem mass spectrometry in positive ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 294.1 → 225.1 for anastrazole and m/z 286.1 → 217.1 for internal standard. Linearity in plasma was observed over the concentration range 0.3–30 ng/mL for anastrazole. The mean recovery for anastrazole was 83.7% with a lower limit of quantification of 0.3 ng/mL. The coefficient of variation of the assay was less than 6.8% and the accuracy was 96.1–102.2%. The validated method was applied to a bioequivalence study of 1 mg anastrazole tablet in healthy human volunteers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Dantonic pill, consisting of Salviae miltiorrhize , Panax notoginseng and Borneol , is a widely used compound Chinese medicine for preventing and treating ischemic cardiovascular diseases in China. In the present study, an original and sensitive method for simultaneous determination of tanshinol (i.e. danshensu), protocatechuic aldehyde, protocatechuic acid, notoginsenoside R1, ginsenoside Rg1 and Rb1 in rat plasma by liquid chromatography–tandem mass spectrometry operated in positive/negative ion switching mode was established and validated. The lower limits of quantification for tanshinol, protocatechuic aldehyde, protocatechuic acid, notoginsenoside R1, ginsenoside Rg1 and Rb1 were 5, 0.5, 1, 0.5, 0.5 and 2 ng/mL, respectively. All of the calibration curves showed good linearity over the investigated concentration range (r > 0.99). Validation results demonstrated that the above compounds were accurately, precisely and robustly quantified in rat plasma. The method was successfully applied to characterize the pharmacokinetic profiles of all six compounds in rats following a single oral administration of Dantonic pill.  相似文献   

5.
We developed and validated an accurate and sensitive LC–MS/MS method for the simultaneous quantitation of ginsenoside Rg3 and Rh2 epimers (R‐Rg3, S‐Rg3, R‐Rh2, and S‐Rh2) in rat plasma. Analytes were extracted from 0.1 mL aliquots of rat plasma by liquid–liquid extraction, using 2 mL of ethyl acetate. In this assay, dioscin (500 ng/mL) was used as an internal standard. Chromatographic separation was conducted using an Acclaim RSLC C18 column (150 × 2.1 mm, 2.2 μm) at 40°C, with a gradient mobile phase consisting of 0.1% formic acid in distilled water and in acetonitrile, a flow rate of 0.35 mL/min, and a total run time of 20 min. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with negative electrospray ionization at m/z 783.4 → 161.1 for R‐Rg3 and S‐Rg3, m/z 621.3 → 161.1 for R‐Rh2 and S‐Rh2, and m/z 867.2 → 761.5 for the internal standard. For R‐Rg3 and S‐Rg3, the lower limit of quantification was 5 ng/mL, with a linear range up to 500 ng/mL; for R‐Rh2 and S‐Rh2, the lower limit of quantification was 150 ng/mL, with a linear range up to 6000 ng/mL. The coefficient of variation for assay precision was less than 10.5%, with an accuracy of 86.4–112%. No relevant cross‐talk or matrix effect was observed. The method was successfully applied to a pharmacokinetic study after oral administration of 400 mg/kg and 2000 mg/kg of BST204, a fermented ginseng extract, to rats. We found that the S epimers exhibited significantly higher plasma concentrations and area under curve values for both Rg3 and Rh2. This is the first report on the separation and simultaneous quantification of R‐Rg3, S‐Rg3, R‐Rh2, and S‐Rh2 in rat plasma by LC‐MS/MS. The method should be useful in the clinical use of ginseng or its derivatives.  相似文献   

6.
Ginsenoside Rk1 (Rk1) exhibited various potent biological activities. However, its pharmacokinetic profile in vivo remains unclear. In the present study, a simple and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for determination of Rk1 in rat plasma and applied in a pharmacokinetic study. The sample was precipitated with acetonitrile and separated on a Zorbax Eclipse XDB C18 column (50 × 2.1 mm, 1.8 μm). The mobile phase was composed of 0.1% formic acid in water and acetonitrile at a flow rate of 0.4 mL/min. Rk1 and internal standard (ginsenoside Rg3) were quantitatively monitored with precursor‐to‐product ion transitions of m/z 765.4 → 441.5 and m/z 783.5 → 621.4, respectively. The assay was linear over the concentration range of 5–1000 ng/mL (r > 0.99) with the LLOQ of 5 ng/mL. Other parameters including intra‐ and inter‐day precision and accuracy, extraction recovery and matrix effect were within the acceptable limits. The analyte was stable under the tested storage conditions. The validated method has been successfully applied to a pharmacokinetic study of Rk1 in rat plasma after intravenous (5 mg/kg) and oral (25 mg/kg, 50 mg/kg) administration. After oral administration, Rk1 could be detected in blood at 30 min and reached the highest concentration at 4.29~4.57 h. Our results demonstrated that Rk1 showed low clearance, moderate half‐life (3.09–3.40 h) and low bioavailability (2.87–4.23%). The study will provide information for the further application of Rk1.  相似文献   

7.
An ultra‐performance liquid chromatography with tandem mass spectrometry (UPLC–MS/MS) method was developed and validated to concurrently determine rhynchophylline and hirsutine in rat plasma. The sample preparation of rat plasma was achieved by alkalization and liquid–liquid extraction. The mass transition of precursor ion → product ion pairs were monitored at m/z 385.2 → 160.0 for rhynchophylline, m/z 369.3 → 144.0 for hirsutine and m/z 414.0 → 220.0 for noscapine (internal standard). This method revealed linear relationships from 2.5 to 50 ng/mL (r2 > 0.997) for rhynchophylline and from 2.5 to 50 ng/mL (r2 > 0.998) for hirsutine. The limit of quantification values for rhynchophylline and hirsutine in rat plasma were both 2.5 ng/mL. Intra‐day and inter‐day precisions were within 10.6% and 12.5%, respectively, for rhynchophylline and hirsutine, and the accuracy (bias) was <10%. Liquid–liquid extraction of rat plasma samples resulted in insignificant matrix effect, and the extraction recoveries were >83.6% for rhynchophylline, 73.4% for hirsutine and 90.7% for the internal standard. This method was applied successfully to a pharmacokinetic study of rhynchophylline and hirsutine in rats after oral administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A highly sensitive liquid chromatography–tandem mass spectrometry method was developed and validated for the determination of limonin in beagle dog plasma using nimodipine as internal standard. The analyte and internal standard (IS) were extracted with ether followed by a rapid isocratic elution with 10 mm ammonium acetate buffer–methanol (26:74, v/v) on a C18 column (150 × 2.1 mm i.d.) and subsequent analysis by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 469.4 → 229.3 and m/z 417.2 → 122.0 were used to measure the analyte and the IS. The assay was linear over the concentration range of 0.625–100 ng/mL for limonin in dog plasma. The lower limit of quantification was 0.312 ng/mL and the extraction recovery was >90.4% for limonin. The inter‐ and intra‐day precision of the method at three concentrations was less than 9.9%. The method was successfully applied to pharmacokinetic study of limonin in dogs. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
A fast, selective, and quantitative ultra‐fast liquid chromatography with tandem mass spectrometry method has been developed and validated for the simultaneous quantitation of polygalaxanthone III, ginsenoside Rb1, ginsenoside Rd, ginsenoside Re, and ginsenoside Rg1 in the plasma of rat and beagle dog after oral administration of Kai‐Xin‐San. After addition of the internal standard, salidroside, the plasma samples were extracted by liquid–liquid extraction and separated on a Venusil MP C18 column with methanol/0.01% acetic acid water as mobile phase. The tandem mass spectrometric detection was performed in the multiple reaction monitoring with turbo ion spray source in a switching ionization mode. The method was examined, and found to be precise and accurate with the linearity range of the compounds. The intra‐ and interday precision and accuracy of the analytes were well within acceptance criteria (±15%). The mean extraction recoveries of analytes and internal standard were all >75.0%. The validated method has been successfully applied to comparing pharmacokinetic profiles of analytes in rat and beagle dog plasma. The results indicated that no significant differences were observed in pharmacokinetic parameters of ginsenoside Rg1, while the others had significant differences, which may due to the different mechanisms of absorption and metabolism.  相似文献   

10.
A highly sensitive, rapid assay method has been developed and validated for the estimation of adenosine in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electro‐spray ionization in the positive‐ion mode. The assay procedure involves extraction of adenosine and phenacetin (internal standard, IS) from rat plasma with a simple protein precipitation extraction process. The method was validated using rat plasma with extinguished adenosine endogenous levels. Chromatographic separation was achieved using a binary gradient using mobile phase A (acetonitrile) and B (0.2% formic acid in water) at a flow rate of 0.50 mL/min on an Atlantis dC18 column with a total run time of 4.0 min. The MS/MS ion transitions monitored were 268 → 136 for adenosine and 180 → 110 for IS. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.48 ng/mL and the linearity range extended from 0.48 to 1210 ng/mL. The intra‐ and inter‐day precisions were in the ranges 2.32–12.7 and 4.01–9.40%, respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
Ginsenoside Rh3 (GRh3) is a bacterial metabolite of ginsenoside Rg5, which is the main component of hot-processed ginseng. A simple, efficient and sensitive method was developed and validated for the determination of GRh3 in rat plasma by LC–tandem mass spectrometry. After protein precipitation with methanol/acetonitrile (1:1, vol/vol) using propranolol as the internal standard, the target analytes were separated on an XDB C18 column, with methanol containing 0.1% formic acid and water containing 0.1% formic acid used as mobile phases for gradient elution. Mass spectrometry was performed in electrospray ion source–positive ion mode and multiple reaction monitoring mode, monitoring the transitions m/z 622.5 → 425.5 and m/z 260.1 → 116.1 for GRh3 and internal standard, respectively. The concentration range of GRh3 was 20–20,000 ng/mL and the correlation coefficient (r2) was greater than 0.99. The accuracy error and relative standard deviation were below 15%. The extraction recovery and matrix effect were 74.2% to 78.7% and 96.9% to 108.4%, respectively. Under different conditions, GRh3 was stable in the range of 1.8%–8.7%. This method has been successfully applied to study the pharmacokinetics of GRh3 with an oral dose of 10.0 mg/kg and an intravenous dose of 2.0 mg/kg in rats, respectively. The absolute bioavailability of GRh3 was 37.6%.  相似文献   

12.
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method for the simultaneous determination of metacavir and its two metabolites in rat plasma was developed and validated. Tinidazole was used as an internal standard and plasma samples were pretreated with one‐step liquid–liquid extraction. In addition, these analytes were separated using an isocratic mobile phase on a reverse‐phase C18 column and analyzed by MS in the selected reaction monitoring mode. The monitored precursor to product‐ion transitions for metacavir, 2′,3′‐dideoxyguanosine, O‐methylguanine and the internal standard were m/z 266.0 → 166.0, m/z 252.0 → 152.0, m/z 166.0 → 149.0 and m/z 248.0 → 202.0, respectively. The standard curves were found to be linear in the range of 1–1000 ng/mL for metacavir, 5–5000 ng/mL for 2′,3′‐dideoxyguanosine and 1–1000 ng/mL for O‐methylguanine in rat plasma. The precision and accuracy for both within‐ and between‐batch determination of all analytes ranged from 2.83 to 9.19% and from 95.86 to 111.27%, respectively. No significant matrix effect was observed. This developed method was successfully applied to an in vivo pharmacokinetic study after a single intravenous dose of 20 mg/kg metacavir in rats. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
A highly sensitive and rapid bioanalytical method has been developed and validated for the estimation of indomethacin in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of indomethacin and phenacetin (internal standard, IS) from rat plasma with acetonitrile. Chromatographic separation was achieved with 0.2% formic acid–acetonitrile (25:75, v/v) at a flow rate of 0.60 mL/min on an Atlantis dC18 column with a total run time 3.0 min. The MS/MS ion transitions monitored were 357.7 → 139.1 for indomethacin and 180.20 → 110.10 for IS. Method validation and pharmacokinetic study plasma analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.51 ng/mL and the linearity was observed from 0.51 to 25.5 ng/mL. The intra‐ and inter‐day precisions were in the range of 1.00–10.2 and 5.88–9.80%, respectively. This novel method has been applied to an oral pharmacokinetic study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Solid dispersion technology was used to improve the bioavailability of probucol due to its low hydrophilicity and high lipophilicity. In this study, a highly rapid and sensitive supercritical fluid chromatography with tandem mass spectrometry method was optimized and validated for the determination of probucol in beagle dog plasma with diazepam as an internal standard. The analyte and internal standard were extracted by acetone and then separated on a polar 2‐ethylpyridine phase column (100 mm × 3 mm, 1.7 μm) at a flow rate of 1.0 mL/min using CO2 (≥99.99%) and methanol (95:5, v/v) as the mobile phase. The mass transition ion‐pair was m/z 515.6→236.2 and 285.2→193.1 for probucol and internal standard, respectively. Excellent linearity was observed over the concentration range of 5–5000 ng/mL (r2 ≥ 0.9999) with a lower limit of quantification of 5 ng/mL. The intra‐ and inter‐day accuracy and precision for all quality control samples were within ±15%. The proposed method was accurate, rapid and reproducible, which was successfully applied to a bioavailabilty evaluation of probucol solid dispersion tablets.  相似文献   

15.
A high‐performance liquid chromatographic assay with tandem mass spectrometric detection was developed to simultaneously quantify fluoxetine and olanzapine in human plasma. The analytes and the internal standard (IS) duloxetine were extracted from 500 μL aliquots of human plasma through solid‐phase extraction. Chromatographic separation was achieved in a run time of 4.0 min on a Hypersil Gold C18 column (50 × 4.6 mm, 5 µm) using isocratic mobile phase consisting of acetonitrile–water containing 2% formic acid (70:30, v/v), at a flow‐rate of 0.5 mL/min. Detection of analytes and internal standard was performed by electrospray ionization tandem mass spectrometry, operating in positive‐ion and multiple reaction monitoring acquisition mode. The protonated precursor to product ion transitions monitored for fluoxetine, olanzapine and IS were m/z 310.01 → 147.69, 313.15 → 256.14 and 298.1 → 153.97, respectively. The method was validated over the concentration range of 1.00–150.20 ng/mL for fluoxetine and 0.12–25.03 ng/mL for olanzapine in human plasma. The intra‐batch and inter‐batch precision (%CV) across four quality control levels was ≤6.28% for both the analytes. In conclusion, a simple and sensitive analytical method was developed and validated in human plasma. This method is suitable for measuring accurate plasma concentration in bioequivalence study and therapeutic drug monitoring as well, following combined administration. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
In the present study, an ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) approach was designed to measure the rat plasma levels of verubecestat with diazepam as the internal standard. Acetonitrile-based protein precipitation was applied for sample preparation, then the analyte verubecestat was subjected to gradient elution chromatography with a mobile phase composed of acetonitrile (A) and 0.1% formic acid in water (B). Verubecestat was monitored by m/z 410.1 → 124.0 transition for quantification by multiple reaction monitoring (MRM) in positive ion electrospray ionization (ESI) source. When the concentration of verubecestat ranged from 1 to 2500 ng/mL, the method exhibited good linearity. For verubecestat, the intra- and inter-day precision were determined with the values of 2.9–9.0% and 0.4–6.5%, respectively; and the accuracy ranged from −2.2% to 10.4%. Matrix effect, extraction recovery, and stability data were in line with the standard FDA guidelines for validating a bioanalytical method. The validity of the developed method was confirmed through the pharmacokinetic study.  相似文献   

17.
A sensitive, rapid and specific liquid chromatography–electrospray ionization–tandem mass spectrometry method was developed and validated for the determination of aristolochic acid‐I (AA‐I) in rat plasma. Finasteride was used as the internal standard (IS). The analyte was separated on a Zorbax Eclipse XDB‐C18 column by isocratic elution with methanol‐10 mM ammonium acetate (75:25, v/v, pH = 7.3) at a flow rate of 0.25 mL/min, and analyzed by mass spectrometry in positive multiple reaction monitoring mode. The precursor‐to‐product ion transitions of m/z 359.0 → 298.2 and m/z 373.1 → 305.2 were used to detect AA‐I and IS, respectively. Good linearity was achieved over a range of 0.4–600 ng/mL. Intra‐ and inter‐day precisions measured as relative standard deviation were less than 13.5%, and accuracy ranged from 94.2 to 97.5%. The developed method was successfully applied in the pharmacokinetic study of AA‐I in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
A rapid and highly sensitive assay method has been developed and validated for the estimation of galantamine (GLM) in rat plasma using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of GLM and phenacetin (internal standard, IS) from rat plasma using acetonitrile. Chromatographic separation was achieved with 0.2% formic acid:acetonitrile (50:50, v/v) at a flow rate of 0.60 mL/min on an Atlantis dC18 column with a total run time 2.5 min. The MS/MS ion transitions monitored were 288.10 → 213.10 for GLM and 180.10 → 110.10 for IS. Method validation was performed as per United States Food and Drug Administration guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.12 ng/mL and linearity was observed from 0.12 to 525 ng/mL. The intra‐ and inter‐day precision were in the ranges of 4.73–11.7 and 5.83–8.64%, respectively. This novel method has been applied to a pharmacokinetic study in rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
Zingiberis Rhizoma and Ginseng Radix et Rhizoma are usually used together for the treatment of ulcerative colitis in clinical practices. However, their compatibility mechanism remains unclear. In this study, a rapid and sensitive liquid chromatography with tandem mass spectrometry method was developed for simultaneous quantification of ginsenoside Re, ginsenoside Rg1, ginsenoside Rb1, and 6-gingerol in rat plasma after oral administration of Zingiberis Rhizoma–Ginseng Radix et Rhizoma herb pair and its single herb extracts. The calibration curves exhibited good linearity, with correlation coefficients of more than 0.993. The precision deviations of intra- and interday analysis were within 10.66%, and accuracy error ranged from −12.74 to 11.56%. The average recoveries of analytes were higher than 76.60% and the matrix effects were minimal. Thus, the validated method was successfully applied to a pharmacokinetic study of four ingredients in normal and ulcerative colitis rat plasma. The results indicated that the pharmacokinetic parameters of four analytes in normal and model groups showed significant differences. The larger exposure (the mean AUC0-t of ginsenoside Re, ginsenoside Rg1, ginsenoside Rb1, and 6-gingerol were increased by 50.93, 141.90, 3.68, and 37.25%, respectively) and slower elimination (the CLz/F of ginsenoside Re, ginsenoside Rg1, and 6-gingerol were decreased by 52.94, 83.64, and 32.18%, respectively) were observed in ulcerative colitis rats. Furthermore, compared with single herbs, the analytes in rat plasma after oral administration of combined extracts presented relatively high systemic exposure levels with AUC0-t > 2000 h·ng/mL and Cmax > 200 ng/mL. Collectively, the differences of pharmacokinetic characteristics revealed the synergistic effect of Zingiberis Rhizoma–Ginseng Radix et Rhizoma herb pair, which provided a valuable and reliable basis for its clinical application in the treatment of ulcerative colitis.  相似文献   

20.
采用液相色谱-串联质谱法快速、灵敏地测定大鼠血浆中人参皂苷Rb1(GRb1)的含量,并将该方法应用于大鼠口服GRb1后的代谢动力学研究。血浆样品采用96孔板进行液-液萃取后,应用Agilent SB-C18色谱柱(100 mm×2.1 mm,3.5μm)进行分离,以甲醇-0.1%甲酸溶液(体积比为75∶25)为流动相进行洗脱,在正离子模式下对GRb1和内标人参皂苷Rg1(GRg1)进行检测,用于定量的离子反应分别为1131.5→365.1(GRb1),823.3→643.4(GRg1)。人参皂苷Rb1血浆样品测定方法的定量线性范围为1~500 ng/mL,线性相关系数大于0.999,定量下限为1 ng/mL,批内和批间精密度(RSD)小于9.05%,回收率为79.7%~81.0%,基质效应为96.6%~99.3%。大鼠灌胃给予Rb15 mg/kg后,大鼠体内血药浓度到达高峰时间tmax为1.53 h,半衰期t1/2为13.54 h,药时曲线面积AUC0~72为16237.76(ng·h)/mL。该方法快速、高效、灵敏,适用于人参皂苷Rb1的代谢动力学研究。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号