首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A simple and sensitive liquid chromatographic method for the separation and quantification of mono- and disaccharides in raw- and processed-milk is described. Samples of cows’, buffalos’, sheeps’ and goats’ milk were analyzed upon clarification and appropriate dilution for the quantification of lactose, galactose, glucose and N-acetylglucosamine (GlcNAc). The separation was accomplished by high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD), using a gold working electrode and dilute alkaline eluents modified by a millimolar concentration of barium acetate. The eluent composition employed was designed to provide optimum separation with respect to the selected sample, without interference from the matrix components. The analytical method was successfully employed for the determination of mono- and disaccharides naturally occurring in dairy milk, mozzarella cheese and whey samples, with high sensitivity and accuracy.  相似文献   

2.
Summary The work presents a GC method for the determination of six organophosphorous pesticide residues in cabbage. Chopped cabbage was blended with acetone, then extracted with the mixture of n-hexane:methylene chloride (1:1). The extract was purified on a GPC column packed with BioBeads SX-3 gel. The pesticides were eluted with the mixture of methylene chloride:cyclohexane (1:1) at the flow rate of 0.5 mL min−1. After concentrating the extract was analysed by GC. Nearly 100 samples of cabbage were analysed; trace residues of dimethoate (about 0.05 ppm) were found in 10 samples. The average recoveries of the pesticides were above 80% with a relative standard deviation mostly less than 10%. Presented at: Balaton Symposium on High-Performance Separation Methods, Siófok, Hungary, September 3–5, 1997.  相似文献   

3.
A simple procedure for the quantitative detection of JWH‐018, JWH‐073, JWH 200, JWH‐250, HU‐210, Δ9‐tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in hair has been developed and fully validated. After digestion with NaOH and liquid–liquid extraction, the separation was performed with an ultra‐high performance liquid chromatography system coupled to a triple quadrupole mass spectrometer operating in the selected reaction monitoring mode. The absence of matrix interferents, together with excellent repeatability of both retention times and relative abundances of diagnostic transitions, allowed the correct identification of all analytes tested. The method was linear in two different intervals at low and high concentration, with correlation coefficient values between 0.9933 and 0.9991. Quantitation limits ranged from 0.07 pg/mg for JWH‐200 up to 18 pg/mg for CBD The present method for the determination of several cannabinoids in hair proved to be simple, fast, specific and sensitive. The method was successfully applied to the analysis of 179 real samples collected from proven consumers of Cannabis, among which 14 were found positive to at least one synthetic cannabinoid. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
Summary A gas chromatographic method using a micropacked column is described for the analysis of lactose, galactose, lactulose and epilactose in processed milks. The method is evaluated for precision and accuracy using phenyl-β-glucoside as an internal standard. Recoveries near 100% were found for lactulose concentrations higher than 0.1 mgml−1, showing coefficients of variation from 5.9 to 9.4%.  相似文献   

5.
Summary A sensitive gas chromatographic method is described for the analysis of fosfomycin (FOS) in chicken plasma using phenylphosphonic acid (PPA) as the internal standard. Plasma samples were ultrafiltered, and the ultrafiltrate was then evaporated to dryness. The residue was reconstituted with a silylation reagent for the derivatization of FOS and PPA. The methodology involves the use of a HP-5 capillary column and a flame ionisation detector (FID). The retention times of FOS and PPA were 4.63 and 8.68 minutes, respectively. Response was linear in the range of 1–150 μ mL−1. The detection and quantitation limits were 1 and 2.1 μ mL−1, respectively. Recovery was determined as 109% for FOS. The method was applied to the determination of FOS in chicken plasma samples collected during pharmacokinetic studies.  相似文献   

6.
Summary An ion-pair, reversed-phase, liquid chromatographic procedure using UV detection for quantitation of furosine is described. The standard plot was linear (r>0.999) over a 5 ng range. An authentic synthesised sample of furosine was used for calibration. Commerical milk samples were analyzed by the described procedure.  相似文献   

7.
A gradient clean‐up method for the quantification of five kinds of banned drugs (two hormones, two sedatives, and one chloramphenicol) in milk powder was developed. We used the combination of solid‐phase extraction purification with gas chromatography and mass spectrometry. Milk powder was initially hydrolyzed by β‐glucuronidase/arylsulfatase, and then the hydrolyzed solution was concentrated and purified using a C8 and cation resin solid‐phase extraction column. To isolate hormones and chloramphenicol drugs, products from the previous step were diluted with methanol and further purified using a silica and diatomite solid‐phase extraction column. After derivatization, the drugs were analyzed by gas chromatography with mass spectrometry, and the hydrolyzed solution was diluted with 5% ammoniated methanol to purify sedatives before gas chromatography with mass spectrometry analysis. Results showed that after adding the banned drugs at concentrations of 0.3–10.0 μg/kg, the average recovery range was 78.2–97.3% with relative standard deviations of 5.3–12.5%. The limit of quantification of the banned drugs (S/N ≥ 10) was 0.3–5.0 μg/kg, whereas the limit of detection (S/N ≥ 3) was 0.1–2.0 μg/kg. The solid‐phase extraction gradient purification system was simple, rapid, and accurate, and could satisfy the detection requirements of hormone, sedatives, and chloramphenicol drugs when used together with gas chromatography and mass spectrometry.  相似文献   

8.
Summary Quantitative gas chromatography of triglycerides in conjunction with established triglyceride formulae can be used to determine various milk fat parameters. Since the evaluation of, for example, iodine number or content of non-milk fats (foreign fats) in milk fat requires only the separation of triglycerides by carbon number and since repeatabilities, especially of the highboiling triglycerides, have been less acceptable with capillary columns in the past, packed columns have been used exclusively. There is, however, an increasing demand for the use of capillary instead of packed columns and to that end the present investigation has been carried out. To achieve a suitable resolution, with this particularly exacting high-temperature application, a short 5 m capillary column of extreme temperature stability has been used. As well as modification of various analytical conditions different injection techniques have been investigated. On-column, PTV and split injection were compared with regard to repeatability. The cold-on-column injection technique was found to produce the best results, being comparable to the excellent precision of a packed column. Thus, a method is now available by means of which the determination of milk fat parameters by the triglyceride formulae, such as the amount of foreign fats in milk fat, can now be carried out with a standardized capillary column.  相似文献   

9.
The current theory of programmed temperature gas chromatography considers that solutes are focused by the stationary phase at the column head completely and does not explicitly recognize the different effects of initial temperature (To) and heating rate (rT) on the retention time or temperature of a homologue series. In the present study, n‐alkanes, 1‐alkenes, 1‐alkyl alcohols, alkyl benzenes, and fatty acid methyl esters standards were used as model chemicals and were separated on two nonpolar columns, one moderately polar column and one polar column. Effects of To and rT on the retention of nonstationary phase focusing solutes can be explicitly described with isothermal and cubic equation models, respectively. When the solutes were in the stationary phase focusing status, the single‐retention behavior of solutes was observed. It is simple, dependent upon rT only and can be well described by the cubic equation model that was visualized through four sequential slope analyses. These observed dual‐ and single‐retention behaviors of solutes were validated by various experimental data, physical properties, and computational simulation.  相似文献   

10.
We discuss the purification of mono‐PEGylated HSA by hydrophobic interaction membrane chromatography. The hydrophobicity difference between the different fractionated species was induced by the addition of a lyotropic salt that caused phase transition of PEG (hydrophilic under normal condition) to a mildly hydrophobic form. The HSA PEGylation reaction mixture was mixed with lyotropic salt and passed through a stack of hydrophilized polyvinylidene fluoride membrane discs. Unmodified HSA was obtained in the flow through, while the PEGylated forms of the protein bound to the membrane and could be eluted by reducing the salt concentration. Among the three major PEGylated forms of HSA present in the feed (i.e. mono–, di–, and tri–), mono‐PEGylated HSA was eluted first and could be resolved from the others. The purified material was analyzed by SDS‐PAGE, dynamic light scattering, and SEC combined with multi‐angle light scattering. All these analytical techniques indicated the presence of species that has a molar mass consistent with mono‐PEGylated HSA. A scaled‐down version of the membrane chromatographic methods could be used for the rapid and sensitive analysis of PEGylated proteins.  相似文献   

11.
Martínez-Castro  I.  Alonso  L.  Juárez  M. 《Chromatographia》1986,21(1):37-40
Summary Tetramethylammonium hydroxide in methanol has been proposed as a catalyst for preparing methyl esters of both free fatty acids and glycerides of fats. Nevertheless, procedures normally recognized as suitable can be inadequate when the fat under study contains noticeable amounts of low relative molecular mass esters. The method using tetramethylammonium hydroxide has been examined and modified in order to analyze milk fats by capillary GC. The pyrolysis methylation of free fatty acids in capillary injectors has been also studied. The modified method was satisfactory for both neutral and acid milk fats.  相似文献   

12.
In this work, sol-gel reaction chemistry was utilized to create 3-(trimethoxysilyl)propyl methacrylate-poly (propylene glycol) polymer coating on amorphous silica. The synthesized sorbent was characterized using energy dispersive X-ray spectrometry, field emission scanning electron microscopy, and thermogravimetric analysis. The sorbent was then used for membrane protected stir-bar supported micro-solid-phase extraction (SB-µ-SPE) of chlorinated hydrocarbons (CHCs) in milk samples and analyzed using gas chromatography mass spectrometry. Sorbent suitability, sorbent quantity, solvent for desorption, solvent volume, time for extraction, time for desorption, and ionic strength were all optimized for extraction. This method resulted in a wide linear range for all tested CHCs with an r2 up to 0.9992. The lower limits of detection ranged between 0.2 and 2.8 ng mL?1. Reproducibility of the method was also determined at three different concentrations ranging between 3.8 and 7.3%. The relative recoveries in milk samples were found to be between 85.1 and 104.3%.  相似文献   

13.
In this work, bentonite magnetic nanoparticles synthesized by a typical coprecipitation method were used as the adsorbent for the magnetic solid‐phase extraction of six quinolones (ciprofloxacin, difloxacin, enrofloxacin, norfloxacin, sarafloxacin, and lomefloxacin) from milk samples followed by high‐performance liquid chromatography with fluorimetric detection. Under the optimized conditions, the linear quantitation range for the six quinolones was 0.3–200 ng/mL, and the correlation coefficients of the calibration curves ranged from 0.9994 to 0.9999. The detection limit of the method was 0.1 ng/mL. Recoveries of quinolones from pure and low‐fat spiked milk samples varied from 80.4 to 92.7% and from 81.3 to 93.5%, respectively. These results demonstrated that the proposed method for the determination of six quinolones in milk samples was rapid, reliable, and efficient.  相似文献   

14.
Maltol, ethyl maltol, vanillin, and ethyl vanillin are important food additives as flavor enhancers. To quantify the four additives in milk powder, a novel 2D liquid chromatographic (2DLC) method was developed in this article. In such a 2DLC system, the target fractions eluted from the first dimensional column (C4) are stored onto the trapping column (C8) for subsequent analysis; after that, they were switched into the second dimensional column (C18) by a two‐position six‐port switching valve. A one‐step sample preparation method was used prior to 2DLC chromatographic analysis, which was easy and convenient. After optimization of all experimental parameters, the new method was validated in terms of linearity, LODs, and LOQs, intra‐ and interday precision, and accuracy. A conventional single‐dimensional liquid chromatographic method was also proposed in this work for comparison. In order to evaluate the applicability of the new 2DLC method, five brands of commercial milk powder samples (n = 8) were analyzed. Vanillin and ethyl vanillin were detected in two samples, respectively. It is showed that the 2DLC method is effective in quality control programs of milk powder products.  相似文献   

15.
16.
Natalia Campillo 《Talanta》2010,80(5):1856-1861
A method based on solid-phase microextraction (SPME) followed by gas chromatography with microwave-induced plasma atomic emission detection for determining dimethylselenide (DMSe) and dimethyldiselenide (DMDSe) in milk and milk by-products is proposed. Parameters affecting the SPME, such as sample volume or mass, ionic strength, adsorption and desorption times and temperatures were optimized in the headspace mode. The matrix effect was evaluated for the different samples studied, concluding that standard additions calibration was required for quantification purposes. The detection limits ranged from 70 to 110 pg mL−1 for DMSe and from 80 to 400 pg mL−1 for DMDSe, depending on the sample under analysis. None of the twenty-three samples analyzed contained the studied compounds at concentrations above the corresponding detection limits.  相似文献   

17.
The monosaccharide compositions of functional polysaccharides are essential for structure elucidation and biological activity determination. A sensitive method based on on‐line hollow‐fiber liquid‐phase microextraction with high‐performance liquid chromatography has been established for the analysis of ten monosaccharide compositions (two uronic acids, two amino sugars and six neutral sugars) of the immunomodulatory polysaccharides. After derivatization , the sample was injected into the lumen of a hollow fiber immersed in butyl ether and separated by liquid chromatography. Under optimized conditions, the calibration curves were linear (r ≥ 0.9996) in the range of 10–2000 μmol L?1. The limits of detection were in the range of 0.04–1.58 μmol L?1, and the recoveries were in the range of 92.1–99.6%, which shows that the method is applicable to the analysis of the monosaccharide composition of various polysaccharides.  相似文献   

18.
The easy shrinkage and swelling of polymer monolithic column when exposed to mobile phase with different polarity is a problem that cannot be ignored. To overcome this drawback, a convenient aqueous two‐phase polymerization approach was used to prepare poly (polyethylene glycol diacrylate, PEGDA) monolithic porous layer open tubular (mono‐PLOT) columns (150 μm). The poly(PEGDA) mono‐PLOT column with homogeneous polymer porous layer was synthesized successfully. A maximum plate number of 41,500 plates per meter for allyl thiourea was obtained under a velocity of 1.8 mm/s. Several kinds of polar molecule were separated on the proposed mono‐PLOT column and a typical hydrophilic interaction retention mechanism was observed. High speed separation of benzoic acids was also carried out, baseline separation of five benzoic acids was successfully achieved within 5 min with a 70 cm mono‐PLOT column at 50°C. Furthermore, the resulting PLOT column was also successfully applied to separate standard analytes of three DNA oxidative damage products and RNA‐modified nucleosides and four chlorophenols. At last, the column could separate alcohols, alkanes, and aromatic isomers via GC. It had more than 20,000 plates per meter for butanol – higher than commercial coatings open tubular columns.  相似文献   

19.
A new, rapid, sensitive, robust, and reliable method has been developed for the qualitative analysis of phosphoserine, phosphoethanolamine, phosphoglycerol, and phosphate using gas chromatography with mass spectrometry and two‐step trimethylsilylation. The method employs hexamethyldisilazane for silylation of the phosphate and hydroxyl groups in the first phase and bis(trimethylsilyl)trifluoroacetamide for silylation of the less‐reactive amino groups in the second phase. This order is of key importance for the method because of the different reactivities of the two reagents and the mechanism of derivatization of the active groups of the analytes. Trimethylsilylated derivatives of the analytes were identified on the basis of their retention times and mass spectra. The probable structures of the major fragments were identified in the spectra of the trimethylsilylated derivatives and characteristic m/z fragments were selected for each analyte. Fragments with m/z 73 and 299 occurred in the spectra of all the analytes. The characteristic retention data were employed to calculate the retention indices of the individual silylated phosphorylated substances in the hydrocarbon range C12–C19 for the DB‐5ms column. The method was employed to measure the polar fraction of the hydrolysate of the cytoplasmic membrane of Bacillus subtilis. The detection limits vary between 5 μg/mL (trimethylsilylated phosphate) and 72 μg/mL (trimethylsilylated phosphoethanolamine).  相似文献   

20.
A high‐performance liquid chromatography with ultraviolet detection method has been developed for the simultaneous determination of a set of reliable markers of renal function, including creatinine, uric acid, kynurenine and tryptophan in plasma. Separation was achieved by an Agilent HC‐C18 (2) analytical column. Gradient elution and programmed wavelength detection allowed the method to be used to analyze these compounds by just one injection. The total run time was 25 min with all peaks of interest being eluted within 13 min. Good linear responses were found with correlation coefficient >0.999 for all analytes within the concentration range of the relevant levels. The recovery was: creatinine, 101 ± 1%; uric acid, 94.9 ± 3.7%; kynurenine, 100 ± 2%; and tryptophan, 92.6 ± 2.9%. Coefficients of variation within‐run and between‐run of all analytes were ≤2.4%. The limit of detection of the method was: creatinine, 0.1 µmol/L; uric acid, 0.05 µmol/L; kynurenine, 0.02 µmol/L; and tryptophan, 1 µmol/L. The developed method could be employed as a useful tool for the detection of chronic kidney disease, even at an early stage. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   