首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Graphene oxide based molecularly imprinted polymers modified with β‐cyclodextrin were prepared as solid‐phase extraction column sorbents for specific recognition and sensitive detection of di(2‐ethylhexyl) phthalate in water samples. The morphology and composition of synthesized sorbents were characterized by scanning electron microscopy, thermo‐gravimetric analysis, Raman spectroscopy, and Fourier‐transform infrared spectroscopy. The conditions affecting the performance of extraction procedures such as desorption solvent types and volume, sample pH and volume were investigated. The loading capacity (8.2 μg/mg) of the prepared sorbents increased eight times after modification with β‐cyclodextrin. The developed extraction procedures coupled to high‐performance liquid chromatography exhibited good linearity (0.2–500 μg/L), low limit of detection (0.052 μg/L), and good precision (relative standard deviation?5.7%) under optimized conditions. The developed solid‐phase extraction technique with prepared sorbents has been successfully applied in extracting trace di(2‐ethylhexyl) phthalate from real natural waters with high efficiency, good selectivity, and desirable recoveries.  相似文献   

2.
In this study, we aim to determine the chemical constituents of six Chinese medicinal materials from the Citrus genus using high‐performance liquid chromatography and high‐resolution mass spectrometry. Eight flavonoids and one coumarin were identified and further quantified as marker substances by high‐performance liquid chromatography method. The separation was performed on an Agilent TC‐C18 column with 0.1% formic acid and acetonitrile as the mobile phase under gradient elution. The analytical method was fully validated in terms of linearity, sensitivity, intra‐ and inter‐day precision and repeatability, limit of detection, limit of quantitation, and recovery. It was subsequently applied to evaluate the quality of 103 batches of the Chinese medicinal materials from the Citrus genus. In addition, the principal constituent analysis was used to compare the samples of different species from the Citrus genus leading to successful classification of the samples in accordance with their origins. It was found that the contents of nine constituents varied greatly in different ripening stages and varieties of the samples from the Citrus genus. In addition, neoeriocitrin and 5,7‐dimethoxycoumarin were determined as two unique constituents of ‘Zhiqiao’ and ‘Foshou’, respectively. In conclusion, this study provides a chemical basis for quality control of Chinese medicinal materials from the Citrus genus.  相似文献   

3.
In this study, poly(styrene‐co‐N‐methacryloyl‐l ‐phenylalanine methyl ester)‐functionalized magnetic nanoparticles were constructed and used as magnetic solid‐phase extraction sorbents for analysis of food preservatives in beverages. To prepare the poly(amino acid)‐based sorbents, N‐methacryloyl‐l ‐phenylalanine methyl ester, and styrene served as the functional monomers and modified onto the magnetic nanoparticles via free radical polymerization. Interestingly, compared with propylparaben and potassium sorbate, the proposed poly(amino acid)‐based sorbents showed a good selectivity to sodium benzoate. The adsorption capacity of the sorbents to sodium benzoate was 6.08 ± 0.31 mg/g. Moreover, the fast adsorption equilibrium could be reached within 5 min. Further, the resultant poly(amino acid)‐based sorbents were applied in the analysis of sodium benzoate in real beverage samples. The results proved that the proposed magnetic solid‐phase extraction sorbents have a great potential for the analysis of preservatives in food samples.  相似文献   

4.
This research highlights the application of highly efficient molecularly imprinted solid‐phase extraction for the preconcentration and analysis of melamine in aquaculture feed samples. Melamine‐imprinted polymers were synthesized employing methacrylic acid and ethylene glycol dimethacrylate as functional monomer and cross‐linker, respectively. The characteristics of obtained polymers were evaluated by scanning electron microscopy, Fourier transform infrared spectroscopy and binding experiments. The imprinted polymers showed an excellent adsorption ability for melamine and were applied as special solid‐phase extraction sorbents for the selective cleanup of melamine. An off‐line molecularly imprinted solid‐phase extraction procedure was developed for the separation and enrichment of melamine from aquaculture feed samples prior to high‐performance liquid chromatography analysis. Optimum molecularly imprinted solid‐phase extraction conditions led to recoveries of the target in spiked feed samples in the range 84.6–96.6% and the relative standard deviation less than 3.38% (n = 3). The aquaculture feed sample was determined, and there was no melamine found. The results showed that the molecularly imprinted solid‐phase extraction protocols permitted the sensitive, uncomplicated and inexpensive separation and pre‐treatment of melamine in aquaculture feed samples.  相似文献   

5.
Sugarcane rind contains some functional phenolic acids. The separation of these compounds from sugarcane rind is able to realize the integrated utilization of the crop and reduce environment pollution. In this paper, a novel protocol based on interfacing online solid‐phase extraction with high‐speed counter‐current chromatography (HSCCC) was established, aiming at improving and simplifying the process of phenolic acids separation from sugarcane rind. The conditions of online solid‐phase extraction with HSCCC involving solvent system, flow rate of mobile phase as well as saturated extent of absorption of solid‐phase extraction were optimized to improve extraction efficiency and reduce separation time. The separation of phenolic acids was performed with a two‐phase solvent system composed of butanol/acetic acid/water at a volume ratio of 4:1:5, and the developed online solid‐phase extraction with HSCCC method was validated and successfully applied for sugarcane rind, and three phenolic acids including 6.73 mg of gallic acid, 10.85 mg of p‐coumaric acid, and 2.78 mg of ferulic acid with purities of 60.2, 95.4, and 84%, respectively, were obtained from 150 mg sugarcane rind crude extracts. In addition, the three different elution methods of phenolic acids purification including HSCCC, elution–extrusion counter‐current chromatography and back‐extrusion counter‐current chromatography were compared.  相似文献   

6.
A simple method for the determination of phenolic acids in Chinese Wolfberry drink based on polyethyleneimine modified porous aromatic framework and graphene oxide composite sorbent for pipette‐tip solid‐phase extraction was developed. Porous aromatic framework and raphene oxide composite materials were grafted by silane coupling agent (3‐Chloropropyl)‐trimethoxysilane. The modified materials were characterized by five kinds of characterization. Experimental results showed that the prepared p‐phenylenediamine, cyanuric chloride, and graphene oxide composite material had a loose structure combined with the framework which improved hydrophobicity, and polyethyleneimine to increase the selectivity with the targets. The parameters of the pipette‐tip solid‐phase extraction procedure including the amount of sorbents, volumes and types of washing solvents and elution solvents were optimized to achieve optimal extraction efficiency. Good linearity of best material was achieved in the range of 0.1–400 µg/mL with correlation coefficient of chlorogenic acid (0.9994), caffeic acid (0.9997), and ferulic acid (0.9998). Recoveries between 93.5 and 102.3% were obtained at three spiked levels with relative standard deviation ≤3.1%. The proposed method was successfully applied for the determination of phenolic acids in Chinese Wolfberry drink sample.  相似文献   

7.
Polydopamine‐coated Fe3O4 magnetic nanoparticles synthesized through a facile solvothermal reaction and the self‐polymerization of dopamine have been employed as a magnetic solid‐phase extraction sorbent to enrich four phenolic compounds, bisphenol A, tetrabromobisphenol A, (S)‐1,1′‐bi‐2‐naphthol and 2,4,6‐tribromophenol, from environmental waters followed by high‐performance liquid chromatographic detection. Various parameters of the extraction were optimized, including the pH of the sample matrix, the amount of polydopamine‐coated Fe3O4 sorbent, the adsorption time, the enrichment factor of analytes, the elution solvent, and the reusability of the nanoparticles sorbent. The recoveries of these phenols in spiked water samples were 62.0–112.0% with relative standard deviations of 0.8–7.7%, indicating the good reliability of the magnetic solid‐phase extraction with high‐performance liquid chromatography method. In addition, the extraction characteristics of the magnetic polydopamine‐coated Fe3O4 nanoparticles were elucidated comprehensively. It is found that there are hydrophobic, π–π stacking and hydrogen bonding interactions between phenols and more dispersible polydopamine‐coated Fe3O4 in water, among which hydrophobic interaction dominates the magnetic solid‐phase extraction performance.  相似文献   

8.
Graphene‐based pipette tip solid‐phase extraction was combined with ultra‐high performance liquid chromatography and tandem mass spectrometry for the determination of carbamate pesticide residues in fruit juice samples. Four milligrams of graphene was used as sorbent material to pack a 1000 μL pipette tip for the extraction of pirimicarb, propoxur, isoprocarb, fenobucarb, and diethofencarb from 3 mL of fruit juice sample. The whole extraction process was finished in 12 min, and the volume of eluent used was only 1.5 mL. Under the optimized conditions, good linear relationship (R > 0.999) and lower limits of detection (0.0022–0.033 ng/mL) were achieved. The recoveries at three spiked levels ranged from 80.90 to 124.60% with relative standard deviations less than 4.88%. Compared with commercially available sorbents including propylsulfonic acid silica, graphitized carbon black, and C18, graphene was superior in extraction efficiency. The proposed method is simple, rapid, sensitive, selective, and solvent saving.  相似文献   

9.
A rapid analytical method based on online solid‐phase extraction with high‐performance liquid chromatography and mass spectrometry has been established and applied to the determination of tannin compounds that may cause adverse effects in traditional Chinese medicine injections. Different solid‐phase extraction sorbents have been compared and the elution buffer was optimized. The performance of the method was verified by evaluation of recovery (≥40%), repeatability (RSD ≤ 6%), linearity (r2 ≥ 0.993), and limit of quantification (≤0.35 μg/mL). Five tannin compounds, gallic acid, cianidanol, gallocatechin gallate, ellagic acid, and penta‐O‐galloylglucose, were identified with concentrations ranging from 3.1–37.4 μg/mL in the analyzed traditional Chinese medicine injections.  相似文献   

10.
Sulfonated poly(styrene‐divinylbenzene) modified with five kinds of amine functional groups was applied to the determination of carbendazim in apple samples with a pipette‐tip solid‐phase extraction method. The structures of the polymers were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis. Five different modifications of the solid‐phase extraction sorbent based on sulfonated poly(styrene‐divinylbenzene) were tested under static and pipette‐tip solid‐phase extraction conditions. The polymer modified with p‐methoxyaniline showed the best recognition capacity and adsorption amount for carbendazim. Under the optimum conditions, 3.00 mg of the adsorbent, 1.00 mL of ethyl acetate as washing solvent, and 1.00 mL of ammonia/acetonitrile (5:95, v/v) as elution solvent were used in the pretreatment procedure of apple samples. The calibration graphs of carbendazim in methanol were linear over 5.00–200.00 μg/mL, and the limits of detection and quantification were 0.01 and 0.03 μg/mL, respectively. The method recoveries of carbendazim were in the range of 91.31–98.13% with associated intraday relative standard deviations of 0.76–2.13% and interday relative standard deviations of 1.10–1.85%. Sulfonated poly(styrene‐divinylbenzene) modified with p‐methoxyaniline showed satisfactory results (recovery: 97.96%) and potential for the rapid purification of carbendazim in apple samples combined with the pipette‐tip solid‐phase extraction.  相似文献   

11.
A novel l‐ phenylalanine molecularly imprinted solid‐phase extraction sorbent was synthesized by the combination of Pickering emulsion polymerization and ion‐pair dummy template imprinting. Compared to other polymerization methods, the molecularly imprinted polymers thus prepared exhibit a high specific surface, large pore diameter, and appropriate particle size. The key parameters for solid‐phase extraction were optimized, and the result indicated that the molecularly imprinted polymer thus prepared exhibits a good recovery of 98.9% for l‐ phenylalanine. Under the optimized conditions of the procedure, an analytical method for l‐ phenylalanine was well established. By comparing the performance of the molecularly imprinted polymer and a commercial reverse‐phase silica gel, the obtained molecularly imprinted polymer as an solid‐phase extraction sorbent is more suitable, exhibiting high precision (relative standard deviation 3.2%, n = 4) and a low limit of detection (60.0 ± 1.9 nmol·L?1) for the isolation of l‐ phenylalanine. Based on these results, the combination of the Pickering emulsion polymerization and ion‐pair dummy template imprinting is effective for preparing selective solid‐phase extraction sorbents for the separation of amino acids and organic acids from complex biological samples.  相似文献   

12.
A simple, sensitive, and selective molecularly imprinted solid‐phase extraction and spectrophotometric method has been developed for the clean‐up and preconcentration of indapamide from human urine. Molecularly imprinted polymers were prepared by a non‐covalent imprinting approach using indapamide as a template molecule, 2‐(trifluoromethyl) acrylic acid as a functional monomer, ethylene glycol dimethacrylate as a crosslinker, N,N‐azobisisobutyronitrile as a thermal initiator and acetonitrile as a porogenic solvent. A non‐imprinted polymer was also prepared in the same way, but in the absence of template. Molecularly imprinted polymer and non‐imprinted polymer sorbents were dry‐packed into solid‐phase extraction cartridges. Eluates from cartridges were analyzed using a spectrophotometer for the determination of indapamide by referring to the calibration curve in the range 0.14–1.50 μg/mL. Preconcentration factor, limit of detection, and limit of quantification were 16.30, 0.025 μg/mL, and 0.075 μg/mL, respectively. A relatively high imprinting factor (9.3) was also achieved and recovery values for the indapamide spiked into human urine were in the range of 80.1–81.2%. In addition, relatively low within‐day (0.17–0.42%) and between‐day (1.1–1.4%) precision values were obtained as well. The proposed molecularly imprinted solid‐phase extraction and spectrophotometric method was successfully applied to selective extraction, preconcentration, and determination of indapamide from human urine samples.  相似文献   

13.
To detect and quantify synephrine in feed, an effective analytical method based on quick, easy, cheap, effective, rugged, and safe solid‐phase extraction coupled to ultra high performance liquid chromatography with tandem mass spectrometry was developed with isotopic internal standards. Pretreatment was performed using quick, easy, cheap, effective, rugged, and safe solid‐phase extraction with primary secondary amine and C18 sorbent as sorbents in combination with Oasis MCX column clean‐up to extract and purify feed samples. Tandem mass spectrometry detection in positive ion mode was conducted in positive multiple reaction monitoring mode in addition to the quantitative internal standard method. Two transitions of synephrine at m/z 168.1/150.0 and 168.1/135.0 were selected, and m/z 168.1/135.0 was determined as the quantification ion pair. D9‐Terbutaline was selected as an internal standard, for which m/z 235.1/153.0 was selected as the quantification ion pair. Good linearity was shown for synephrine in the range of 0.5–50 μg/L, and the correlation coefficient exceeded 0.999. The recoveries in three different feed samples at three spiked levels were 81.42–112.08%, and the relative standard deviations were not greater than 14.66%. The method proposed in this study was reliable and highly effective, and its sensitivity, accuracy, and precision are suitable for determining synephrine residues in feed samples.  相似文献   

14.
Here in, magnetic nanoparticles combined with graphene oxide adsorbent were fabricated via a microwave‐assisted synthesis method, and used in the solid‐phase extraction of three phenolic compounds (phenol, 4‐nitrophenol, and m‐methylphenol) in environmental water samples. Various instrumental methods were employed to characterize the magnetic nanoparticles modified with graphene oxide. The influence of experimental parameters, such as desorption conditions, amount of adsorbent, extraction time, and pH, on the extraction efficiency was investigated. Owing to the high surface area and excellent adsorption capacity of the prepared material, satisfactory extraction was achieved. Under optimum conditions, a linear response was observed in the concentration range of 1.000–100.0 μg/L for phenol, 0.996–99.6 μg/L for 4‐nitrophenol, and 0.975–97.5 μg/L for m‐methylphenol, with correlation coefficients in the range of 0.9995–0.9997. The limit of detection (signal‐to‐noise ratio of 3) of the method varied between 0.5 and 0.8 μg/L. The relative standard deviations were <5.2%. The recovery percentages of the method were in the range of 89.1–104.3%. The results indicate that the graphene oxide‐modified magnetic nanoparticles possess high adsorptive abilities toward phenolic compounds in environmental water samples.  相似文献   

15.
A sol–gel coating technique was applied for the preparation of a solid‐phase microextraction fiber by coating the metal–organic framework UiO‐67 onto a stainless‐steel wire. The prepared fiber was explored for the headspace solid‐phase microextraction of five nitrobenzene compounds from water samples before gas chromatography with mass spectrometric detection. The effects of the extraction temperature, extraction time, sample solution volume, salt addition, and desorption conditions on the extraction efficiency were optimized. Under the optimal conditions, the linearity was observed in the range of 0.015–12.0 μg/L for the compounds in water samples, with the correlation coefficients (r) of 0.9945–0.9987. The limits of detection of the method were 5.0–10.0 ng/L, and the recoveries of the analytes from spiked water samples for the method were in the range of 74.0–102.0%. The precision for the measurements, expressed as the relative standard deviation, was less than 11.9%.  相似文献   

16.
A prepared molecularly imprinted polymer with ethyl p‐hydroxybenzoate as template molecule was applied for the first time to a homemade solid‐phase microextraction fiber. The molecularly imprinted polymer‐coated solid‐phase microextraction fiber was characterized by scanning electron microscopy and thermogravimetric analysis. Various parameters were investigated, including extraction temperature, extraction time, and desorption time. Under the optimum extraction conditions, the molecularly imprinted polymer‐coated solid‐phase microextraction fiber exhibited higher selectivity with greater extraction capacity toward parabens compared with the nonimprinted polymer‐coated solid‐phase microextraction fiber and commercial fibers. The molecularly imprinted polymer‐coated solid‐phase microextraction fiber was tested using gas chromatography to determine parabens, including methyl p‐hydroxybenzoate, ethyl p‐hydroxybenzoate, and propyl p‐hydroxybenzoate. The linear ranges were 0.01–10 μg/mL with a correlation coefficient above 0.9943. The detection limits (under signal‐to‐noise ratio of 3) were below 0.30 μg/L. The fiber was successfully applied to the simultaneous analysis of three parabens in spiked soy samples with satisfactory recoveries of 95.48, 97.86, and 92.17%, respectively. The relative standard deviations (n=6) were within 2.83–3.91%. The proposed molecularly imprinted polymer‐coated solid‐phase microextraction method is suitable for selective extraction and determination of trace parabens in food samples.  相似文献   

17.
This article reports the synthesis of N‐vinylimidazole/divinylbenzene resins by suspension polymerization. Several polymerization conditions were tested to achieve a quantitative incorporation of the N‐vinylimidazole monomer into the final polymer while a high specific surface area was maintained. The retention properties of several copolymers with different nitrogen contents were evaluated with the solid‐phase extraction of polar compounds from water samples, and the best results were obtained for a polymer containing 6.3% N with a surface area of 627 m2 g?1. The sorption properties of the resins were compared to those of styrene–divinylbenzene and other copolymers containing nitrogen, and the results were best for the new sorbents with N‐vinylimidazole as the polar monomer. © 2004 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 42: 2019–2025, 2004  相似文献   

18.
A novel molecularly imprinted solid‐phase extraction with spectrofluorimetry method has been developed for the selective extraction of telmisartan from human urine. Molecularly imprinted polymers were prepared by a noncovalent imprinting approach through UV‐radical polymerization using telmisartan as a template molecule, 2‐dimethylamino ethyl methacrylate as a functional monomer, ethylene glycol dimethacrylate as a cross‐linker, N,N‐azobisisobutyronitrile as an initiator, chloroform as a porogen. Molecularly imprinted polymers and nonimprinted control polymer sorbents were dry‐packed into solid‐phase extraction cartridges, and eluates from cartridges were analyzed using a spectrofluorimeter. Limit of detection and limit of quantitation values were 11.0 and 36.0 ng/mL, respectively. A very high imprinting factor (16.1) was achieved and recovery values for the telmisartan spiked in human urine were in the range of 76.1–79.1%. In addition, relatively low within‐day (0.14–1.6%) and between‐day (0.11–1.31%) precision values were obtained. Valsartan was used to evaluate the selectivity of sorbent as well. As a result, a sensitive, selective, and simple molecularly imprinted solid‐phase extraction with spectrofluorimetry method has been developed and successfully applied to the direct determination telmisartan in human urine.  相似文献   

19.
In this study, organic aerogels were synthesized by the sol–gel polycondensation of mixed cresol with formaldehyde in a slightly basic aqueous solution. Carbon aerogels and xerogels are generated by pyrolysis of organic aerogels. The novel sol–gel‐based micro‐solid‐phase extraction sorbent, resorcinol–formaldehyde xerogel, was employed for preconcentration of some selected herbicides. Three herbicides of the aryloxyphenoxypropionate group, clodinafop‐propargyl, haloxyfop‐etotyl, and fenoxaprop‐P‐ethyl, were extracted from aqueous samples by micro‐solid‐phase extraction and subsequently determined by gas chromatography with mass spectrometry. The effect of different parameters influencing the extraction efficiency of these herbicides including sample flow rate, sample volume, and extraction time were investigated and optimized. Under optimum conditions, linear calibration curves in the range of 0.10–500 ng/L with R2 > 0.99 were obtained. The relative standard deviation at 50 μg/L concentration level was lower than 10% (n = 5) and detection limits were between 0.05 and 0.20 μg/L. The proposed method was successfully applied to the sampling and extraction of herbicides from Zayanderood and paddy water samples.  相似文献   

20.
The application of layered double hydroxide–Al2O3–polymer mixed‐matrix disks for solid‐phase extraction is reported for the first time. Al2O3 is embedded in a polymer matrix followed by an in situ metal‐exchange process to obtain a layered double hydroxide–Al2O3–polymer mixed‐matrix disk with excellent flow‐through properties. The extraction performance of the prepared disks is evaluated as a proof of concept for the automated extraction using sequential injection analysis of organic acids (p‐hydroxybenzoic acid, 3,4‐dihydroxybenzoic acid, gallic acid) following an anion‐exchange mechanism. After the solid‐phase extraction, phenolic acids were quantified by reversed‐phase high‐performance liquid chromatography with diode‐array detection using a core–shell silica–C18 stationary phase and isocratic elution (acetonitrile/0.5% acetic acid in pure water, 5:95, v/v). High sensitivity and reproducibility were obtained with limits of detection in the range of 0.12–0.25 μg/L (sample volume, 4 mL), and relative standard deviations between 2.9 and 3.4% (10 μg/L, = 6). Enrichment factors of 34–39 were obtained. Layered double hydroxide–Al2O3–polymer mixed‐matrix disks had an average lifetime of 50 extractions. Analyte recoveries ranged from 93 to 96% for grape juice and nonalcoholic beer samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号