首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
In this paper, we present an investigation of the influence of the gas chromatographic separation system on the determination of polybrominated diphenyl ethers (PBDEs). Capillary columns, retention gaps and press-fit connectors, as well as different injection techniques have been evaluated with respect to yield and repeatability. The split/splitless injection has been optimized and compared to on-column injection, the septum equipped temperature programmable injector (SPI) and the programmable temperature vaporizing (PTV) injector. Furthermore, a comparison of the different operational modes of the PTV injector is presented. The results show that there are large variations in the yield of PBDEs depending on the column and the injection systems. Especially the high molecular weight BDE congeners can be subject to severe discrimination. Unfavorable conditions can lead to a complete loss of nona and deca substituted BDE congeners.  相似文献   

2.
Polybrominated diphenyl ethers (PBDEs) are group of chemicals which are representative persistent organic pollutants (POPs) and used as brominated flame retardants for many consumer products. PBDEs were phased out since 2009 but are still frequently observed in various environmental matrices and human body. Here, we report ssDNA aptamers which bind to BDE47, one of the PBDE congeners commonly found in various environmental matrices, and show affinity to other major tri-to hepta- BDE congeners. The PBDE specific aptamers were isolated from random library of ssDNA using Mag-SELEX. Two out of 15 sequences, based on their alignment and hairpin loop structures, were chosen to determine dissociation constant with BDE47 and showed from picomolar to nanomolar affinities (200 pM and 1.53 nM). The aptamers displayed high selectivity to the original target, BDE47, and implying general specificity to PBDE backbone with varying affinities to other congeners. Further, we showed that the use of two aptamers together could enhance the separation efficiency of BDE47 and other BDE congeners when dissolved in a solvent compared to use of single aptamer. These aptamers are expected to provide a tool for preliminary screening or quick separation of PBDEs in environmental samples prior to trace quantitative analysis.  相似文献   

3.
Polybrominated diphenyl ethers (PBDEs) are flame retardants. As a consequence of their widespread use, they have been released into the environment. PBDEs are lipophilic organic contaminants that enter wastewater treatment plants (WWTPs) from urban, agricultural and industrial discharges. Because of their low aqueous solubility and resistance to biodegradation, up to 90% of the PBDEs are accumulated in the sewage sludge during the wastewater treatment. To assess the possibilities for sludge re-use, a reliable determination of the concentrations of these PBDEs is of crucial importance. Six PBDE congeners (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153 and BDE 154) are listed as priority substances under the EU Water Framework Directive. In the present work a simple analytical method with minimal sample-preparation steps was developed for a sensitive and reliable determination of the six PBDEs in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS). For this purpose an extraction procedure was optimised. Different extracting agents (methanol (MeOH), acetic acid (AcOH)/MeOH mixture (3:1) and 0.1 mol L−1 hydrochloric acid (HCl) in MeOH) followed by the addition of a Tris-citrate buffer (co-extracting agent) and iso-octane were applied under different modes of extraction (mechanical shaking, microwave- and ultrasound-assisted extraction). Mechanical shaking or the microwave-assisted extraction of sewage sludge with 0.1 mol L−1 HCl in MeOH and the subsequent addition of the Tris-citrate buffer and the iso-octane extracted the PBDEs from the complex sludge matrix most effectively. However, due to easier sample manipulation during the extraction step, mechanical shaking was used. The PBDEs in the organic phase were quantified with GC-ICP-MS by applying a standard addition calibration method. The spike recovery test (recoveries between 95 and 104%) and comparative analyses with the species-specific isotope-dilution (ID) GC-ICP-MS confirmed the accuracy of the developed analytical procedure. The procedure is sensitive (limits of detection (LODs) for PBDEs congeners between 0.2 and 0.3 ng g−1), repeatable and reproducible (RSDs 2.2–5.7%) and was applied for the determination of PBDEs in sewage sludge samples collected three times at the municipal WWTP over a period of 16 years.  相似文献   

4.
An efficient microwave-assisted extraction (MAE) method has been developed and evaluated for the quantification of eight major polybrominated diphenylethers (PBDEs) in sewage sludge. The PBDEs were extracted from wet and dry sludge in a microwave extraction unit using a hexane/acetone mixture for 35 min at a controlled temperature of 130 °C. The extract was concentrated, cleaned up on a silica gel column, and analyzed by gas chromatography/mass spectrometry (GC/MS) in the negative chemical ionization (NCI) mode. The MAE procedure exhibited higher extraction efficiency, specifically for BDE (brominated diphenylether) 209, than the conventional Soxhlet extraction. The test congeners were clearly separated under specific instrumental operating conditions, at a source temperature of 230 °C and a column length of 20 m. The present analytical method showed recovery efficiencies ranging from 80 to 110% when applied to the PBDE-free sludge spiked with eight PBDE congeners. The efficiency of the MAE method was confirmed using sludge obtained from four sewage treatment plants (STPs). The results indicate that BDE 47, 99, and 209 are the most abundant congeners present in these sewage sludges, which is consistent with previous reports.  相似文献   

5.
Polybrominated diphenyl ethers (PBDEs) are flame retardants, which due to their widespread use are frequently present as pollutants in the environment. In the EU Water Framework Directive (WFD) six PBDE congeners (BDE 28, BDE47, BDE 99, BDE 100, BDE 153 and BDE 154) are listed as priority substances. The uncertainty of the analytical method used for their determination in water samples at environmental quality standard (EQS) level (0.5 ng L−1 for the ΣPBDEs) should be equal or less than 50% and the limit of quantification (LOQ) for ΣPBDEs below 0.15 ng L−1. To meet these requirements, an analytical procedure for the determination of these six PBDEs in environmental water samples by gas chromatography–inductively coupled plasma mass spectrometry (GC–ICP-MS) was developed. The acidification of water samples to pH 2 maintained the stability of PBDEs for at least 20 days. The use of Tris–citrate buffer enabled efficient desorption of PBDEs from suspended particulate matter (SPM) and humic acids (HA), and their further quantitative solvent extraction into 2 mL of iso-octane. When 300 mL of water sample was used for analysis and the organic phase concentrated to 25 μL, the expanded uncertainty for determination of PBDEs at EQS level was found to be around 40% (a coverage factor for a confidence level of 95%, k = 2), and the LOQ for the ΣPBDEs 0.109 ng L−1. Finally, to demonstrate the applicability of the newly developed GC–ICP-MS procedure, PBDEs were determined in river and sea water samples.  相似文献   

6.
This study presents a time‐ and solvent‐saving method, pressurized liquid extraction (PLE), to extract polybrominated diphenyl ethers (PBDEs) in sediment samples. The effects of various operating parameters (i.e., extraction solution, temperature, pressure, static/dynamic extraction times) for the quantitative extraction of PBDEs by home‐made PLE were systematically investigated and optimized. The analytes were then identified and quantitated by gas chromatography‐mass spectrometry (GC‐MS) in selected ion monitoring (SIM) mode. The 16 PBDE congeners (from tri‐ to deca‐BDE) can be completely extracted by dichloromethane: n‐hexane (3/2, v/v) at 100 °C and 100 atm combined with 15 min static and then 15 min dynamic extraction steps. Recovery of PBDEs in spiked sediment samples ranged from 52 to 104% with 2‐16% RSD, except for BDE‐206. Limits of quantitation (LOQ) were established between 4 and 400 pg/g (dry weight) in 10 g of sediment sample. The extraction efficiency of the PLE was also compared with the traditional Soxhlet extraction method. The total contents of PBDEs ranged from 8.0 to 37.9 ng/g (dry weight) in various river and coastal sediment samples in Taiwan. Deca‐BDE (BDE‐209) was the major PBDE detected in these sediment samples.  相似文献   

7.
Comprehensive two-dimensional gas chromatography with micro electron-capture detection (GCxGC-muECD) was evaluated for the separation of 125 polybrominated diphenyl ethers (PBDEs). From among the six column combinations that were evaluated, DB-1x007-65HT was found to be the most suitable because of: (i) the highest number of BDE congeners separated; (ii) the least decomposition of higher brominated congeners; and (iii) the most suitable maximum operating temperature. The separation of the 125 BDE congeners from five hydroxy- and two methoxy-BDEs and nine other brominated flame retardants (polybrominated biphenyls, tetrabromobisphenol-A, methyl-tetrabromobisphenol-A and hexabromocyclododecane) was also studied. Fluorinated BDEs were found to be valuable internal standards for the determination of BDEs because of their very similar physico-chemical properties and excellent separation from the parent BDEs, mainly in the second dimension. GCxGC-time-of-flight MS and GCxGC-muECD were shown to be useful tools to identify decomposition products of nona- and deca-substituted BDEs, which are formed during the GC run. Three nona-BDEs were shown to be the major decomposition products of BDE 209.  相似文献   

8.
建立了一种同时测定沉积物中不同赋存形态的多溴联苯醚(PBDEs)和四溴双酚A(TBBPA)的分析方法.样品由等体积的丙酮和正己烷混合溶剂抽提得到自由态目标物,再通过碱性水解反应释放束缚态目标化合物.通过调节酸度(pH值)实现PBDEs和TBBPA的分离和提取.PBDEs由复合硅胶柱净化,运用气相色谱-质谱(负离子化学源)-分时段选择离子监测技术测定;TBBPA经重氮甲烷衍生化反应后由酸性硅胶柱预纯化,运用气相色谱-质谱(电子轰击源)-分时段选择离子监测技术测定.8种低溴联苯醚(BDE28,-47,-66,-100,-99,-154,-153,-183),十溴联苯醚(BDE209)和TBBPA的检出限分别为0.6~12.5 pg/g,172 pg/g,4 2 pg/g.方法具有良好的准确度和精确度,回收率均在74%~106%之间,RSD≤10%.对东江沉积物样品的分析表明,本方法能够实现不同形态的PBDEs 和TBBPA的有效检测.  相似文献   

9.
气相色谱-负化学源质谱快速测定母乳中的多溴联苯醚   总被引:1,自引:0,他引:1  
建立了母乳中8种多溴联苯醚(PBDEs:BDE28,BDE47,BDE99,BDE100,BDE153,BDE154,BDE183,BDE209)的气相色谱-负化学源质谱测定方法(GC-NCI/MS)。样品经索氏提取、酸化硅胶除脂、硅胶氧化铝色谱柱净化后,在7 m长的毛细管气相色谱柱上快速分离,NCI/MS以选择离子监测模式测定目标化合物。其中,三溴~七溴联苯醚采用内标法定量,十溴联苯醚(BDE209)采用同位素稀释法定量。8种PBDEs的检出限为1.74~6.35 pg/g(以脂肪计)。加标回收试验的回收率为61.5%~108%,相对标准偏差为2.06%~10.1%(n=6)。并采用母乳参考物质进一步证实了该方法的准确可靠。该方法提高了BDE209的分析灵敏度,而且分析成本相对较低,分析时间短,适于推广。  相似文献   

10.
A large volume injection fast-GC-MS method has been developed, optimized and evaluated for the determination of polybrominated diphenyl ethers, including the decabrominated diphenyl ether (BDE-209). The programmed-temperature vaporiser injection parameters, temperature programming of the GC oven, and the physical dimensions of the narrow bore GC column were investigated to find the optimal operating conditions for the analysis. Depending on parameter settings the yield of the PBDEs and particularly BDE-209, varies significantly. Volumes up to 125 microl were successfully injected and a fast GC separation was performed, with retention times as short as 6.4 min for the last eluting compound, BDE-209. In a pilot study an air sample, collected at an electronics dismantling facility, was analyzed. Low-resolution mass spectrometry in electron capture negative ion mode was used for detection. Nine BDE congeners, including BDE-209, were identified and quantified.  相似文献   

11.
鱼肉组织中多溴联苯醚的定量分析   总被引:9,自引:0,他引:9  
多溴联苯醚(PBDEs)是一类广泛用于家用电器、电子产品、塑料泡沫、家居装饰材料等行业的添加型阻燃剂[1],使用量最多的是五溴联苯醚(penta-BDE),八溴联苯醚(octa-BDE)和十溴联苯醚(deca-BDE)3种[2]。最近的研究表明[4-6],多溴联苯醚已广泛地存在于各种环境介质、生物体及人体中  相似文献   

12.
Standard reference materials (SRMs) are valuable tools in developing and validating analytical methods to improve quality assurance standards. The National Institute of Standards and Technology (NIST) has a long history of providing environmental SRMs with certified concentrations of organic and inorganic contaminants. Here we report on new certified and reference concentrations for 27 polybrominated diphenyl ether (PBDE) congeners in seven different SRMs: cod-liver oil, whale blubber, fish tissue (two materials), mussel tissue and sediment (two materials). PBDEs were measured in these SRMs, with the lowest concentrations measured in mussel tissue (SRM 1974b) and the highest in sediment collected from the New York/New Jersey Waterway (SRM 1944). Comparing the relative PBDE congener concentrations within the samples, we found the biota SRMs contained primarily tetrabrominated and pentabrominated diphenyl ethers, whereas the sediment SRMs contained primarily decabromodiphenyl ether (BDE 209). The cod-liver oil (SRM 1588b) and whale blubber (SRM 1945) materials were also found to contain measurable concentrations of two methoxylated PBDEs (MeO-BDEs). Certified and reference concentrations are reported for 12 PBDE congeners measured in the biota SRMs and reference values are available for two MeO-BDEs. Results from a sediment interlaboratory comparison PBDE exercise are available for the two sediment SRMs (1941b and 1944).  相似文献   

13.
Three commonly applied extraction techniques for persistent organic chemicals, Soxhlet extraction (SE), accelerated solvent extraction (ASE) and microwave-assisted extraction (MAE), were applied on soil and fish samples in order to evaluate their performances. For both PCBs and PBDEs, the two more recent developed techniques (ASE and MAE) were in general capable of producing comparable extraction results as the classical SE, and even higher extraction recoveries were obtained for some PCB congeners with large octanol-water partitioning coefficients (Kow). This relatively uniform extraction results from ASE and MAE indicated that elevated temperature and pressure are favorable to the efficient extraction of PCBs from the solid matrices. For PBDEs, difference between the results from MAE and ASE (or SE) suggests that the MAE extraction condition needs to be carefully optimized according to the characteristics of the matrix and analyte to avoid degradation of higher brominated BDE congeners and improve the extraction yields.  相似文献   

14.
The analysis of brominated flame retardants, such as polybrominated diphenyl ethers (PBDEs), has received increased interest because of their toxicity and ubiquity. According to European Union Directive 2008/105/EC, the development of highly sensitive and selective methods capable of determining PBDEs at low concentration levels (<0.5 ng/L) is necessary. In this work, an SPE method was developed for the analysis of the six PBDEs (BDE‐28, BDE‐47, BDE‐99, BDE‐100, BDE‐153, BDE‐154) specified by the aforementioned directive in surface waters. The analyses were performed by GC coupled to magnetic sector high‐resolution MS. The conditions were also optimized to detect the target compounds in water samples at concentrations below the environmental quality standards established by European legislation. The validated method provided adequate linearity (determination coefficient, R2 ≥ 0.9960), recovery (101–120%, except for BDE‐47 at 5 ng/L, 127%), and precision values (RSD < 20%) at two fortification levels (0.2 and 5 ng/L). The method showed LODs and LOQs ranging from 0.02 to 0.05 and from 0.05 to 0.1 ng/L, respectively. The method was applied in surface water samples, allowing the determination of these compounds at the limits established by current legislation.  相似文献   

15.
《Analytica chimica acta》2004,520(1-2):237-243
In the Czech Republic no study on the levels of brominated flame retardants in human milk has been conducted, yet. In the first step analytical method for determination of PBDEs in this bioindicator matrix was implemented. Liquid–liquid extraction (LLE) (hexane, diethyl ether), followed by gel permeation chromatography was employed for isolation of PBDEs. Identification and quantification of PBDEs was carried out by GC–MS operated in negative chemical ionisation (NCI). Two mass spectrometric technologies, one employing quadrupole and the other one high resolution (HR) time-of-flight (TOF) analyzer, etc. were used in our study. Detection limits (LODs) obtained by quadrupole analyzer ranged from 0.02 to 0.05 ng g−1 lipid weight, using high resolution time-of-flight analyzer LODs were significantly lower, ranging from 0.002–0.005 ng g−1 lipid weight, what enabled detection of minor PBDE congeners.

Within this pilot study 103 breast milk samples, obtained from mothers living in Olomouc region, were examined. Ten PBDE congeners were determined. All samples examined till now contained PBDEs residues, the dominating contaminant representing this group was congener BDE 47. In most of analysed samples levels of this compound ranged from 0.2 to 2 ng g−1 of lipid weight. Three exceptionally contaminated samples, containing levels of PBDEs 5–10 times higher than other samples, were found.  相似文献   


16.
The major octabromo isomer of technical octabromo diphenyl ether mixture (technical octaBDE) DE-79 was isolated by RP-HPLC. Three serially coupled columns (each 250 mm long) enabled a good separation of the target compound from other congeners using 100% ACN as eluent. Approximately 100 microg of the target compound was isolated with a purity of >90% and investigated by MS for confirmation of the degree of bromination. 1H-NMR and 2-D 1H-13C correlation NMR spectra unequivocally clarified that the octaBDE in question is 2,2',3,3',4,4',6,6'-octabromodiphenyl ether (BDE 197). Based on annual production rates of technical BDE products (1999/2001), approximately 380 tons of BDE 197 were annually produced which, on the long term, may enter the environment. Compared with other individual BDE congeners, BDE 197 has the seventh highest application rate. Reductive debromination of BDE 197 can lead to four hepta-, 15 hexa-, 23 penta-, and 28 tetra-BDE isomers, respectively. This variety includes all known major BDEs of environmental concern (BDE 47, 85, 99, 100, 153, 154, and 183). The identification of BDE 197 in technical octaBDE DE-79 strongly suggests that research on the environmental fate of BDEs should include this key-BDE congener.  相似文献   

17.
A method has been developed for gas chromatographic peak recognition of polybrominated diphenyl ethers (PBDEs) under different temperature programs. On the basis of an identification database of retention parameters (A, B values) of gas chromatography and retention times of the selected internal standards, the retention times of BDEs can be accurately estimated. In comparison with the experimental retention values, the predicted retention times have been proved to be very accurate. In addition, owing to only a part of BDE analytical standards are available, using 40 BDEs as a training set, the quantitative relationship between retention parameters of BDEs and molecular connectivity indexes has been found. The correlation coefficients are greater than 0.997. The A, B values of all the remaining 169 BDE congeners have been predicted.  相似文献   

18.
An organically modified silicate (ORMOSIL) SPME stationary phase molecularly imprinted with BDE-209 has been successfully fabricated by conventional sol-gel technique from phenyltrimethoxysilane and tetraethoxysilane. The thickness of the ORMOSIL-SPME stationary phase, on fused-silica optical fibres, was measured to be ca. 9.5 μm with a volume of ca. 0.12 μL. Rebinding assays and Scatchard analysis revealed that the imprinted ORMOSIL-SPME stationary phase possessed a binding affinity, KB, of 7.3 ± 1.7 × 1010 M−1 for BDE-209, with a receptor site density, Bmax, of 1.2 × 10−3 pmol per SPME device. Besides its molecular template, the ORMOSIL-SPME stationary phase also showed good affinity (log KB ≥ 9.5) for smaller BDE congeners commonly found in the natural environment. The density of receptor sites within the imprinted matrix for those smaller BDE congeners was even higher than that for BDE-209. This may be attributable to the binding site heterogeneity of the imprinting process that creates deformed binding sites that are suitable for the accommodation of the smaller BDE congeners. Compared to the commercially available polyacrylate and polydimethylsiloxane SPME stationary phases, the imprinted ORMOSIL-SPME devices showed much higher pre-concentration ability towards polybrominated diphenyl ethers (PBDEs), even in direct immersion sampling at room temperature. Coupled with GC-NCI-MS and GC-μECD, the imprinted ORMOSIL-SPME device was able to achieve detection sensitivity of 0.2-3.6 pg mL−1 and 1-8.8 pg mL−1, respectively, for commonly occurring BDE congeners, including medium to high molecular weight PBDEs. The imprinted ORMOSIL-SPME device has been successfully applied to monitor PBDE contents in municipal wastewaters.  相似文献   

19.
A method for the determination of 14 polybrominated diphenyl ethers (PBDEs) in sludge from wastewater treatment plants is presented. PBDEs were extracted by matrix solid‐phase dispersion assisted by sonication and determined by isotope dilution gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode, using labelled 13C‐PBDEs as internal standards. The limits of detection and quantification for the tri‐ to hepta‐BDEs were in the range of 0.05 to 0.5 ng/g dry weight and 0.15 to 1.8 ng/g dry weight, respectively, and 1.6 ng/g dry weight and 5.6 ng/g dry weight for deca‐BDE‐209. The proposed analytical method was applied to determine PBDE levels in sewage sludge samples collected from 19 water treatment plants located in the province of Madrid (Spain). In all of the examined samples, BDE‐100 and BDE‐154 were the main compounds found with a mean concentration of 3.9 and 2.0 ng/g, respectively. PBDEs were detected in all of the samples, and their total concentrations not considering BDE‐209 were between 3.9 and 23.0 ng/g dry weight. The dominant PBDE congener in sewage sludge was BDE‐209, which constituted 38.7 to 97.3% of the total, and showed concentration levels ranging from 8.1 to 717.2 ng/g dry weight.  相似文献   

20.
Growing concern on the environmental impact of polybrominated diphenyl ethers (PBDEs) has created the need for rapid and quality assured analytical methods to quantify PBDEs in a spectrum of matrix types. This study presents the first validated method for the quantification of major PBDE congeners (47, 99 and 100) in marine biological tissues using microwave-assisted extraction (MAE). The recovery of polychlorinated biphenyls and various organochlorine pesticides has also been ascertained. Analytical accuracy, precision, limits of detection and cleanup efficiency were evaluated for PBDE congeners, and empirical data justifies the use of MAE for the extraction and analysis of PBDEs in biological matrices. MAE was also compared to Soxhlet extraction efficiency for PBDEs in the standard reference materials SRM2978 and SRM1588a and gave comparable results (<15% variation).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号