首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Redox changes occur in some circumstances when organic compounds are analyzed by desorption electrospray ionization mass spectrometry (DESI-MS). However, these processes are limited in scope and the data presented here suggest that there are only limited analogies between the redox behavior in DESI and the well-known solution-phase electrochemical processes in standard electrospray ionization (ESI). Positive and negative ion modes were both investigated and there is a striking asymmetry between the incidence of oxidation and of reduction. Although in negative ion mode DESI experiments, some aromatic compounds were ionized as odd-electron anion radicals, examples of full reduction were not found. By contrast, oxidation in the form of oxygen atom addition (or multiple oxygen atom additions) was observed for several different analytes. These oxidation reactions point to chemically rather than electrochemically controlled processes. Data is presented which suggests that oxidation is predominantly caused by reaction with discharge-created gas-phase radicals. The fact that common reducing agents and known antioxidants such as ascorbic acid are not modified, while a saturated organic acid like stearic acid is oxidized in DESI, indicates that the usual electrochemical redox reactions are not significant but that redox chemistry can be induced under special experimental conditions.  相似文献   

2.
Alternative ionization methods are increasingly being utilized to increase the versatility and selectivity of liquid chromatography/mass spectrometry (LC/MS). One such technique is the practice of using commercially available atmospheric pressure chemical ionization (APCI) sources with the corona discharge turned off, a process termed no-discharge APCI (ND-APCI). The relative LC/MS responses for several different classes of veterinary drugs were obtained by using ND-APCI, electrospray ionization (ESI), and APCI. While the ND-APCI-MS and -MSn spectra for these compounds were comparable with ESI, ND-APCI provided advantages in sensitivity and selectivity for some compounds. Drugs that were charged in solution as cations or sodium adducts responded particularly well with this technique. Instrumental parameters such as temperatures, gas and liquid flow rates, and source design were investigated to determine their effect on the process of ND-APCI. This paper explores advantages of using ND-APCI for the determination and confirmation of drug residues that might be found in food matrices, including malachite green residues in fish tissue and avermectin residues in milk.  相似文献   

3.
The oxidation behavior of DNA and RNA nucleotides is studied by an on‐line set‐up consisting of an electrochemical thin‐layer cell (EC) directly coupled to electrospray ionization mass spectrometry (ESI‐MS). This set‐up allows the generation of nucleotide oxidation products in the electrochemical cell at increasing potentials. Moreover, the products are determined directly, without isolation or derivatization steps, by electrospray ionization time of flight mass spectrometry (ESI‐ToF/MS). The dependence of the mass spectra on the applied potential is displayed as ‘mass voltammograms’. An advanced set‐up, consisting of the electrochemical cell coupled to electrospray ionization tandem mass spectrometry (EC/ESI‐MS/MS) allows further structure elucidation based on fragmentation experiments. The electrochemical conversion is performed using a boron doped diamond (BDD) working electrode, which is known to generate hydroxyl radicals at high potentials. The capability of the EC‐MS system to generate highly relevant oxidation products which also occur upon oxidative damage in vivo is demonstrated in this study by the formation of well known biomarkers for DNA damage, including 2′‐deoxy‐8‐oxo‐guanosine 5′‐monophosphate.  相似文献   

4.
The occurrence of electrochemical processes during the operation of an electrospray ionization (ESI) source is well established. In the positive ion mode, electrons are drawn from the ESI metal capillary to a high voltage power supply. These electrons are the product of charge-balancing oxidation reactions taking place at the liquid/metal interface of the ion source. In a recent study, (Anal. Chem.2001, 73, 4836-4844), our group has shown that the introduction of a ground loop can dramatically enhance the rate of these oxidation processes. Such a ground loop can be introduced by connecting the sample infusion syringe (or the liquid chromatography column, in the case of LC-MS studies) to ground. The magnitude of the ground loop current can be controlled by the electrolyte concentration in the analyte solution, and by the dimensions of the capillary connecting the syringe needle and the ESI source. Using ferrocene as a model system, it is demonstrated that the introduction of such a ground loop can significantly enhance the signal intensity of analytes that form electrochemically ionized species during ESI. However, analytes that form protonated molecular ions, such as reserpine, also show higher signal intensities when a ground loop is introduced into the system. This latter observation is attributed to the occurrence of electrolytic solvent (acetonitrile and/or water) oxidation processes. These reactions generate protons within the ion source, and thus facilitate the formation of [M + nH](n+) ions. Overall, this work provides an example of how the careful control of electrochemical parameters can be exploited to optimize signal intensities in ESI-MS.  相似文献   

5.
Fundamental studies have greatly improved our understanding of electrospray, including the underlying electrochemical reactions. Generally regarded as disadvantageous, we have recently shown that corona discharge (CD) can be used as an effective method to create a radical cation species [M]+., thus optimizing the electrochemical reactions that occur on the surface of the stainless steel (SS) electrospray capillary tip. This technique is known as CD initiated electrochemical ionization (CD-ECI). Here, we report on the fundamental studies using CD-ECI to induce analytically useful in-source fragmentation of a range of molecules that complex transition metals. Compounds that have been selectively fragmented using CD-ECI include enolate forming phenylglycine containing peptides, glycopeptides, nucleosides, and phosphopeptides. Collision induced dissociation (CID) or other activation techniques were not necessary for CD-ECI fragmentation. A four step mechanism was proposed: (1) complexation using either Fe in the SS capillary tip material or Cu(II) as an offline complexation reagent; (2) electrochemical oxidation of the complexed metal and thus formation of a radical cation (e.g.; Fe ? e? → Fe+); (3) radical fragmentation of the complexed compound; (4) electrospray ionization of the fragmented neutrals. Fragmentation patterns resembling b- and y-type ions were observed and allowed the localization of the phosphorylation sites.  相似文献   

6.
Mol R  de Jong GJ  Somsen GW 《Electrophoresis》2008,29(17):3575-3581
The potential of nonaqueous electrokinetic chromatography (NAEKC) using cyclodextrins (CD) for the analysis of basic drugs and related compounds was evaluated. Both UV absorbance and mass spectrometric (MS) detection were employed. Addition of neutral CD to the NA background electrolyte did not significantly enhance the separation of a test mixture of basic drugs, and no change in selectivity was observed. In contrast, anionic single-isomer-sulfated CD strongly added to the selectivity of the NAEKC system inducing an improved resolution among the test compounds and increasing the migration time window. The applicability of the NAEKC system using anionic CD is demonstrated by the profiling of a sample of the drug amiodarone that had been stored for 1 year at room temperature. Amiodarone is poorly soluble in water. NAEKC-UV analysis indicated the presence of at least seven impurities in the amiodarone sample. In order to identify these compounds, the NAEKC system was coupled directly to electrospray ionization (ESI) ion-trap MS. The total of detected impurities increased to 12 due to the added sensitivity and selectivity of MS detection. Based on the acquired MS/MS data, three sample constituents could be identified as 'known' impurities (British Pharmacopoeia), whereas for three unknown impurities molecular structures could be proposed. Estimated limits of detection for amiodarone using the NAEKC method were 1 microg/mL with UV detection and 15 ng/mL with ESI-MS detection (full-scan). Based on relative responses, the impurity content of the stored drug substance was estimated to be 0.33 and 0.47% using NAEKC-UV and NAEKC-ESI-MS, respectively.  相似文献   

7.
Due to their low polarities and dielectric constants, analytes in solvents such as hexane, chloroform, and ethyl acetate exhibit poor electrospray ionization (ESI) efficiency. These are deemed to be “non-ESI-friendly” solvents. Continuous flow extractive desorption electrospray ionization (CF-EDESI) is a novel ambient ionization technique that was recently developed in our group to manipulate protein charge distributions. Here we demonstrate its potential for ionizing analytes from non-ESI-friendly solvents. This feature makes CF-EDESI attractive to the general analytical community due to its apparent potential in lipidomics, normal phase separations, and hyphenation of mass spectrometry with HPLC-NMR systems. In this context, interest was subsequently initiated to discern mechanistic aspects of CF-EDESI. To achieve this, mechanistic experiments associated with a seemingly similar ambient ionization technique, extractive electrospray ionization (EESI), were emulated to compare CF-EDESI and EESI. Analysis of a series of fatty acids in multiple solvents in the negative ionization mode revealed differences between the two techniques. Whereas EESI has been previously shown to operate via extraction of analytes into the spray solvent, data presented here for CF-EDESI point toward a liquid-liquid mixing process to facilitate ionization. Further, a partial factorial design experiment was performed to evaluate the effects of different experimental variables on signal intensity. Sample flow rate was confirmed to be among the most significant factors to affect sensitivity. As a whole, the work presented provides greater insight into a new ambient ionization process, which exhibits expanded capabilities over conventional ESI; in this case, for direct analysis from non-ESI-friendly solvents.  相似文献   

8.
Different phenylenediamines were used to explore anodic oxidation in solution during electrospray ionization (ESI) mass spectrometry analysis. In our experiments, a series of unknown ionic species was detected in the phenylenediamine solutions. Our results propose that reactions of phenylenediamines with species formed by anodic oxidation of typical ESI solvents during the electrospray ionization process such as formaldehyde are producing these peaks. Identification of these compounds inter alia suggests formal alkylation, a reaction not reported so far as a result of electrolytic oxidation in the prospective organic solvents.  相似文献   

9.
In this work, we give the report of significant detection sensitivity improvement of electrospray ionization (ESI) mass spectra of polysaccharides by adding various ionic liquid compounds into samples. Mass spectra obtained were greatly simplified and appeared to be similar to spectra from matrix-assisted laser desorption/ionization due to the narrow charge number distribution. Mass spectra of polysaccharides with the attachment of either anion or cation of ionic liquid compounds were observed. No protonated or deprotonated polysaccharide ions were detected when ionic liquid compounds were added into samples. Little alkali-attached polysaccharide ions were observed. Ionic liquid-assisted ESI (ILA-ESI) mass spectrometry has significantly improved the detection sensitivity of large neutral polysaccharide compounds.  相似文献   

10.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

11.
Electrospray ionization (ESI) involves the dispersion of a liquid containing analytes of interest into a fine aerosol by applying a high potential difference to the sample solution with respect to a counter electrode. Thus, from the electrochemical point of view, the ESI source represents a two-electrode controlled-current electrochemical flow cell. The electroactive compounds part of the solvent sprayed may be altered by occurring electrolysis (oxidation in positive ion mode and reduction in negative ion mode). These reactions can be troublesome in the context of unknown identification and quantification. In the search for a simple, inexpensive, and efficient way to suppress electrochemical oxidation in positive ESI, the usability of ascorbic acid, hydroquinone, and glutathione for homogenous redox buffering was tested. Performance of the antioxidants was assessed by analyzing pharmaceutical compounds covering a broad range of functional groups prone to oxidation. Different emitter setups were applied for continuous infusion, flow injection, and liquid chromatography/mass spectrometry experiments. Best performance was obtained with ascorbic acid. In comparison to hydroquinone and glutathione, ascorbic acid offered superior antioxidant activity, a relatively inert oxidation product, and hardly any negative effect on the ionization efficiency of analytes. Furthermore, ascorbic acid suppressed the formation of sodiated forms and was able to induce charge state reduction. Only in the very special case of analyzing a compound isobaric to ascorbic acid, interference with the low-abundant [ascorbic acid+H](+) signal may become a point of attention.  相似文献   

12.
In this proof-of-principle study, the applicability of electrospray ionization-mass spectrometry (ESI-MS) to characterize the reducing potencies of natural antioxidants is demonstrated. The ESI source represents a controlled-current electrochemical cell. The interfacial potential at the emitter electrode will be at or near the electrochemical potential of those reactions that sufficiently supply all the required current for the ESI circuit. Indicator molecules prone to oxidation in ESI such as amodiaquine were used to visualize the impact of reducing compounds on the interfacial potential. The extent of inhibition of the oxidation of the indicator molecule was found to be dependent on the kind and amount of antioxidant added. Concentration–inhibition curves were constructed and used to compare reducing potencies and to rank antioxidants. This ranking was found to be dependent on the electrode material–indicator molecule combination applied. For fast and automated characterization of the reducing potencies of electrochemically active molecules, a flow-injection system was combined with ESI-MS. Liquid chromatography was used to process complex biological samples, such as red and white wine. Due to their high content of different polyphenols, red wine fractions were found to exhibit higher reducing potencies than the corresponding white wine fractions. Furthermore, for 14 important natural antioxidants, the results obtained with the controlled-current EC–ESI-MS assay were compared to those obtained with chemical antioxidant assays. Irrespectively of the kind of assay used to test the reducing potency, gallic acid, quercetin, and epicatechin were found to be potent reductants. Other antioxidants performed well in one particular assay only. This observation suggests that different kinds of redox and antioxidant chemistry were assessed with each of the assays applied. Therefore, several assays should be used to comprehensively study antioxidants and their reducing potencies.
Figure
Fractions of a red wine sample were screened by ESI-MS for compounds showing reducing potency.  相似文献   

13.
The extent to which electrochemistry on-line with electrospray mass spectrometry can be used to mimic cytochrome P450 catalyzed oxidations has been investigated. Comparisons on the mechanistic level have been made for most reactions in an effort to explain why certain reactions can, and some cannot, be mimicked by electrochemical oxidations. The EC/MS/MS system used successfully mimics in cases where the P450 catalyzed reactions are supposed to proceed via a mechanism initiated by a one-electron oxidation, such as N-dealkylation, S-oxidation, P-oxidation, alcohol oxidation and dehydrogenation. The P450 catalyzed reactions initiated via direct hydrogen atom abstraction, such as O-dealkylation and hydroxylation of unsubstituted aromatic rings, generally had a too high oxidation potential to be electrochemically oxidized below the oxidation potential limit of water, and were not mimicked by the EC/MS/MS system. Even though the EC/MS/MS system is not able to mimic all oxidations performed by cytochrome P450, valuable information can be obtained concerning the sensitivity of the substrate towards oxidation and in which position of the molecule oxidations are likely to take place. For small-scale electrochemical synthesis of metabolites, starting from the drug, the EC/MS/MS system should be very useful for quick optimization of the electrochemical conditions. The simplicity of the system, and the ease and speed with which it can be applied to a large number of compounds, make it a useful tool in drug metabolism research.  相似文献   

14.
A novel method for the manufacturing of microchips for on-chip combinations of electrochemistry (EC) and sheathless electrospray ionisation mass spectrometry (ESI-MS) is described. The technique, which does not require access to clean-room facilities, is based on the incorporation of an array of gold microcoil electrodes into a poly(dimethylsiloxane)(PDMS) microflow channel equipped with an integrated graphite based sheathless ESI emitter. Electrochemical measurements, which were employed to determine the electroactive area of the electrodes and to test the microchips, show that the manufacturing process was reproducible and that the important interelectrode distance in the electrochemical cell could to be adequately controlled. The EC-ESI-MS device was evaluated based on the ESI-MS detection of the oxidation products of dopamine. The results demonstrate that the present on-chip approach enables full potentiostatic control of the electrochemical cell and the attainment of very short transfer times between the electrochemical cell and the electrospray emitter. The transfer times were 0.6 and 1.2 s for flow rates of 1.0 and 0.5 microL min(-1), respectively, while the electrochemical conversion efficiency of the electrochemical cell was found to be 30% at a flow rate of 0.5 microL min(-1). To decouple the electrochemical cell from the ESI-MS high voltage and to increase the user-friendliness, the on-line electrochemistry-ESI-MS experiments were performed using a wireless Bluetooth battery-powered instrument with the chip floating at the potential induced by the ESI high voltage. The described on-chip EC-ESI-MS device can be used for fundamental electrochemical investigations as well as for applications based on the use of electrochemically controlled sample pretreatment, preconcentration and ionisation steps prior to ESI-MS.  相似文献   

15.
When zotepine, an antipsychotic drug, was electrochemically oxidized using electrospray ionization mass spectrometry (ESI-MS) coupled with a microflow electrolytic cell, [M + 16 + H]+ (m/z 348), [M-H]+ (m/z 330) and [M-14 + H]+ (m/z 318) were observed as electrochemical oxidation product ions (M represents the zotepine molecule). Although a major fragment ion that was derived from the dimethyl aminoethyl moiety was observed only at m/z 72 in the collision-induced dissociation (CID) spectrum of zotepine, new fragments such as m/z 315 and 286 ions could be generated in the CID spectrum by combining electrochemical oxidation and CID. Since these fragments were relatively specific with high ion strength, it was thought that they would be useful for developing a sensitive LC-MS/MS assay. The S-oxide and N-demethylated products were detected by electrolysis assuring that a portion of P450 metabolites of zotepine could be mimicked by the electrochemistry/electrospray ionization mass spectrometry (EC/ESI-MS) system.  相似文献   

16.
系统地比较了3种常用的离子化技术电喷雾电离(ESI)、大气压化学电离(APCI)、大气压光致电离(APPI)对脂类化合物的离子化效率、检测灵敏度和覆盖范围,以探讨多重离子化液相色谱-质谱(LC-MS)方法在血清脂质组学研究中的适用性.血清样本经甲基叔丁基醚萃取后,采用Ascentiss Express C8 色谱柱(150 mm×2.1 mm, 2.7 μm)和二元线性梯度洗脱分离,流动相(A)为乙腈-水(3∶2, V/V, 含0.1%甲酸, 10 mmol/L甲酸铵),B为异丙醇-乙腈(9∶1, V/V, 含0.1%甲酸,10 mmol/L甲酸铵),分别采用ESI、APCI和APPI离子源正、负离子模式进行质谱检测.结果表明,ESI离子源对脂肪酸类、甘油脂类、甘油磷脂类化合物、鞘磷脂类化合物的离子化效率最高,对异戊烯醇脂类化合物的离子化效率与APPI离子源相当,APPI离子源对胆固醇(酯)类化合物的检测灵敏度最高,APCI离子源对各类化合物的检测灵敏度均低于ESI或APPI离子源;采用ESI和APPI离子源相结合的LC-MS脂质组学分析方法可以提高分析方法的整体灵敏度和血清中脂类信息检测的完整性.  相似文献   

17.
In this paper we describe results based on the combination of atmospheric pressure photoionization (APPI) with atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The main purpose of combining more than one ionizer is to extend the range of compounds that can be simultaneously analyzed. Three modes of operation are presented; use of either ionizer, simultaneous use of two ionizers, and rapid switching between ionizers during a single chromatographic run. The dual ionizer configurations only minimally affect the performance of either ionizer relative to the standard single-ionizer sources. However, it is observed that the operation of both ionizers together does not typically give the sum signal from either source operating alone. For APCI/APPI the signal can range from less than that of either source alone to the sum of the two individual sources. For ESI/APPI, we observed large suppressions of the ESI multiply-charged signal of proteins when the APPI source was on. These behaviors are presumed to be due to the interaction of the initially formed ions by both sources and attests to the importance of ion-molecule reactions that occur during and after the primary ionization events. We give examples of compounds that are preferentially ionized by either APPI, APCI or ESI and present thermochemical arguments based on molecular structure and functionality to explain this behavior. The dual source is also shown to be able to operate in negative ion mode opening up the potential to conduct wide ranging chemical analyses.  相似文献   

18.
The performance of the atmospheric pressure photoionization (APPI) technique was evaluated against five sets of standards and drug-like compounds and compared to atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The APPI technique was first used to analyze a set of 86 drug standards with diverse structures and polarities with a 100% detection rate. More detailed studies were then performed for another three sets of both drug standards and proprietary drug candidates. All 60 test compounds in these three sets were detected by APPI with an overall higher ionization efficiency than either APCI or ESI. Most of the non-polar compounds in these three sets were not ionized by APCI or ESI. Analysis of a final set of 201 Wyeth proprietary drug candidates by APPI, APCI and ESI provided an additional comparison of the ionization techniques. The detection rates in positive ion mode were 94% for APPI, 84% for APCI, and 84% for ESI. Combining positive and negative ion mode detection, APPI detected 98% of the compounds, while APCI and ESI detected 91%, respectively. This analysis shows that APPI is a valuable tool for day-to-day usage in a pharmaceutical company setting because it is able to successfully ionize more compounds, with greater structural diversity, than the other two ionization techniques. Consequently, APPI could be considered a more universal ionization method, and therefore has great potential in high-throughput drug discovery especially for open access liquid chromatography/mass spectrometry (LC/MS) applications.  相似文献   

19.
The metabolites formed via the major metabolic pathways of haloperidol in liver microsomes, N‐dealkylation and ring oxidation to the pyridinium species, were produced by electrochemical oxidation and characterized by ultra‐performance liquid chromatography/electrospray ionization mass spectrometry (UPLC/ESI‐MS). Liver microsomal incubations and electrochemical oxidation in the presence of potassium cyanide (KCN) resulted in two diastereomeric cyano adducts, proposed to be generated from trapping of the endocyclic iminium species of haloperidol. Electrochemical oxidation of haloperidol in the presence of KCN gave a third isomeric cyano adduct, resulting from trapping of the exocyclic iminium species of haloperidol. In the electrochemical experiments, addition of KCN almost completely blocked the formation of the major oxidation products, namely the N‐dealkylated products, the pyridinium species and a putative lactam. This major shift in product formation by electrochemical oxidation was not observed for the liver microsomal incubations where the N‐dealkylation and the pyridinium species were the major metabolites also in the presence of KCN. The previously not observed dihydropyridinium species of haloperidol was detected in the samples, both from electrochemical oxidation and the liver microsomal incubations, in the presence of KCN. The presence of the dihydropyridinium species and the absence of the corresponding cyano adduct lead to the speculation that an unstable cyano adduct was formed, but that cyanide was eliminated to regenerate the stable conjugated system. The formation of the exocyclic cyano adduct in the electrochemical experiments but not in the liver microsomal incubations suggests that the exocyclic iminium intermediate, obligatory in the electrochemically mediated N‐dealkylation, may not be formed in the P450‐catalyzed reaction. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
We report on the development of a new laser-ionization (LI) source operating at atmospheric pressure (AP) for liquid chromatography/mass spectrometry (LC/MS) applications. APLI is introduced as a powerful addition to existing AP ionization techniques, in particular atmospheric-pressure chemical ionization (APCI), electrospray ionization (ESI), and atmospheric pressure photoionization (APPI). Replacing the one-step VUV approach in APPI with step-wise two-photon ionization strongly enhances the selectivity of the ionization process. Furthermore, the photon flux during an ionization event is drastically increased over that of APPI, leading to very low detection limits. In addition, the APLI mechanism generally operates primarily directly on the analyte. This allows for very efficient ionization even of non-polar compounds such as polycyclic aromatic hydrocarbons (PAHs). The APLI source was characterized with a MicroMass Q-Tof Ultima II analyzer. Both the effluent of an HPLC column containing a number of PAHs (benzo[a]pyrene, fluoranthene, anthracene, fluorene) and samples from direct syringe injection were analyzed with respect to selectivity and sensitivity of the overall system. The liquid phase was vaporized by a conventional APCI inlet (AP probe) with the corona needle removed. Ionization was performed through selective resonance-enhanced multi-photon ionization schemes using a high-repetition-rate fixed-frequency excimer laser operating at 248 nm. Detection limits well within the low-fmol regime are readily obtained for various aromatic hydrocarbons that exhibit long-lived electronic states at the energy level of the first photon. Only molecular ions are generated at the low laser fluxes employed ( approximately 1 MW/cm(2)). The design and performance of the laser-ionization source are presented along with results of the analysis of aromatic hydrocarbons.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号